Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software dependability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Isotopically nonstationary metabolic flux analysis (INST-MFA): putting theory into practice

Typically, 13 C flux analysis relies on assumptions of both metabolic and isotopic steady state. If metabolism is steady but isotope labeling is not allowed to fully equilibrate, isotopically nonstationary metabolic flux analysis (INST-MFA) can be used to estimate fluxes. This requires solution of differential equations that describe the time-dependent labeling of network metabolites, while iteratively adjusting the flux and pool size parameters to match the transient labeling measurements. INST-MFA holds a number of unique advantages over approaches that rely solely upon steady-state isotope enrichments. First, INST-MFA can be applied to estimate fluxes in autotrophic systems, which consume only single-carbon substrates. Second, INST-MFA is ideally suited to systems that label slowly due to the presence of large intermediate pools or pathway bottlenecks. Finally, INST-MFA provides increased measurement sensitivity to estimate reversible exchange fluxes and metabolite pool sizes, which represents a potential framework for integrating metabolomic analysis with 13 C flux analysis. This review highlights the unique capabilities of INST-MFA, describes newly available software tools that automate INST-MFA calculations, presents several practical examples of recent INST-MFA applications, and discusses the technical challenges that lie ahead.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of Ultrawide Bandgap Photoconducting Semiconductor Switches into High-Voltage, High-Current Pulser Systems

In this feasibility study we will evaluate the viability of integrating ultrawide bandgap (UWBG) photoconducting semiconductor switches (PCSS) in high-voltage pulser systems capable of driving low-impedance dynamic loads critical for next-generation accelerator and RF-source applications. The project consisted of developing modelling tools that would inform design of UWBG PCSS packages that could be mounted onto conventional circuit boards. Specifically, we are interested in evaluating the following through simulation software: (1) resistance to electrical breakdown (2) proximity effects due to high-frequency skin effect (3) transient behavior from switching (4) effective transmission of RF signals (5) thermal dynamics of the switch under operation (6) sensitivity to inhomogeneities in optical excitation of the material (7) cross-talk effects from parallel switching structures, and (8) susceptibility of system to damaged components. The project resulted in the development of a special-purpose circuit code that implements photoconductivity physics. This code was used to evaluate objectives 1-6 above, identifying a critical requirement associated with the need for fine control of dopant concentrations in the UWBG material to reach an optimal solution for voltage standoff and laser light responsivity requirements. In addition, we identified that the temperature dependence of the electrical conductivity of this material was typically not well-measured and developed a platform for measuring both the “dark” and “illuminated” conductivity on real physical switches in the lab to better inform our models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-329: Dosimetric Impact of Implementing Metal Artifact Reduction Methods and Metal Energy Deposition Kernels for Photon Dose Calculations

Purpose: To investigate two strategies for reducing dose calculation errors near metal implants: use of CT metal artifact reduction methods and implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) method. Methods: Radiochromic film was used to measure the dose upstream and downstream of titanium and Cerrobend implants. To assess the dosimetric impact of metal artifact reduction methods, dose calculations were performed using baseline, uncorrected images and metal artifact reduction Methods: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI imaging with metal artifact reduction software applied (MARs).To assess the impact of metal kernels, titanium and silver kernels were implemented into a commercial collapsed cone C/S algorithm. Results: The CT artifact reduction methods were more successful for titanium than Cerrobend. Interestingly, for beams traversing the metal implant, we found that errors in the dimensions of the metal in the CT images were more important for dose calculation accuracy than reduction of imaging artifacts. The MARs algorithm caused a distortion in the shape of the titanium implant that substantially worsened the calculation accuracy. In comparison to water kernel dose calculations, metal kernels resulted in better modeling of the increased backscatter dose at the upstream interface but decreased accuracy directly downstream of the metal. We also found that the success of metal kernels was dependent on dose grid size, with smaller calculation voxels giving better accuracy. Conclusion: Our study yielded mixed results, with neither the metal artifact reduction methods nor the metal kernels being globally effective at improving dose calculation accuracy. However, some successes were observed. The MARs algorithm decreased errors downstream of Cerrobend by a factor of two, and metal kernels resulted in more accurate backscatter dose upstream of metals. Thus, these two strategies do have the potential to improve accuracy for patients with metal implants in certain scenarios. This work was supported by Public Health Service grants CA 180803 and CA 10953 awarded by the National Cancer Institute, United States of Health and Human Services, and in part by Mobius Medical Systems.

60 APPLIED LIFE SCIENCES↗

EV-ELM (Electric Vehicle Policies with the Energy Language Model) [SWR-25-156]

Electric Vehicle Policies with the Energy Language Model (EV-ELM) leverages previous work using Large Language Models (LLMs) to find, download, and parse policy information related to energy infrastructure. In this application, we use LLMs to find policy documents related to the permitting and installation of electric vehicle charging infrastructure. This software contains the code to find, download, and parse these documents, while a related data record in the Open Energy Data Initiative (OEDI) will include the resulting output dataset that can be used for downstream analysis. The EV-ELM repository contains code for the EV-ELM project, which focuses on retrieving and processing EV permitting processes using large language models. The project is composed of two pipelines: (1) a web scraping pipeline for discovering and downloading EV permitting documents, and (2) a document parsing and extraction pipeline that processes the downloaded files to produce structured data. The web scraping pipeline is designed to extract relevant information from various websites, while the document parsing pipeline processes and analyzes the extracted documents to derive meaningful insights. Both pipelines depend on the NLR elm repository, which provides essential tools and functionalities for handling and processing the data. The web scraping pipeline is a modified version of the ordinance_gpt example within the elm repository. It has been adapted to fit the specific requirements of the EV-ELM project, ensuring that it effectively captures and processes the necessary information related to EV permitting.

Olson, Reid [National Laboratory of the Rockies (N↗

OPERA models for predicting physicochemical properties and environmental fate endpoints

The collection of chemical structure information and associated experimental data for quantitative structure–activity/ property relationship (QSAR/QSPR) modeling is facilitated by an increasing number of public databases containing large amounts of useful data. However, the performance of QSAR models highly depends on the quality of the data and modeling methodology used. This study aims to develop robust QSAR/QSPR models for chemical properties of environmental interest that can be used for regulatory purposes. This study primarily uses data from the publicly available PHYSPROP database consisting of a set of 13 common physicochemical and environmental fate properties. These datasets have undergone extensive curation using an automated workflow to select only high-quality data, and the chemical structures were standardized prior to calculation of the molecular descriptors. The modeling procedure was developed based on the five Organization for Economic Cooperation and Development (OECD) principles for QSAR models. A weighted k-nearest neighbor approach was adopted using a minimum number of required descriptors calculated using PaDEL, an open-source software. The genetic algorithms selected only the most pertinent and mechanistically interpretable descriptors (2–15, with an average of 11 descriptors). The sizes of the modeled datasets varied from 150 chemicals for biodegradability half-life to 14,050 chemicals for logP, with an average of 3222 chemicals across all endpoints. The optimal models were built on randomly selected training sets (75%) and validated using fivefold cross-validation (CV) and test sets (25%). The CV Q2 of the models varied from 0.72 to 0.95, with an average of 0.86 and an R2 test value from 0.71 to 0.96, with an average of 0.82. Modeling and performance details are described in QSAR model reporting format and were validated by the European Commission’s Joint Research Center to be OECD compliant. All models are freely available as an open-source, command-line application called OPEn structure–activity/property Relationship App (OPERA). OPERA models were applied to more than 750,000 chemicals to produce freely available predicted data on the U.S. Environmental Protection Agency’s CompTox Chemistry Dashboard.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DEEP WIDEBAND SINGLE POINTINGS AND MOSAICS IN RADIO INTERFEROMETRY: HOW ACCURATELY DO WE RECONSTRUCT INTENSITIES AND SPECTRAL INDICES OF FAINT SOURCES?

Many deep wideband wide-field radio interferometric surveys are being designed to accurately measure intensities, spectral indices, and polarization properties of faint source populations. In this paper, we compare various wideband imaging methods to evaluate the accuracy to which intensities and spectral indices of sources close to the confusion limit can be reconstructed. We simulated a wideband single-pointing (C-array, L-Band (1–2 GHz)) and 46-pointing mosaic (D-array, C-Band (4–8 GHz)) JVLA observation using a realistic brightness distribution ranging from 1 μ Jy to 100 mJy and time-, frequency-, polarization-, and direction-dependent instrumental effects. The main results from these comparisons are (a) errors in the reconstructed intensities and spectral indices are larger for weaker sources even in the absence of simulated noise, (b) errors are systematically lower for joint reconstruction methods (such as Multi-Term Multi-Frequency-Synthesis (MT-MFS)) along with A-Projection for accurate primary beam correction, and (c) use of MT-MFS for image reconstruction eliminates Clean-bias (which is present otherwise). Auxiliary tests include solutions for deficiencies of data partitioning methods (e.g., the use of masks to remove clean bias and hybrid methods to remove sidelobes from sources left un-deconvolved), the effect of sources not at pixel centers, and the consequences of various other numerical approximations within software implementations. This paper also demonstrates the level of detail at which such simulations must be done in order to reflect reality, enable one to systematically identify specific reasons for every trend that is observed, and to estimate scientifically defensible imaging performance metrics and the associated computational complexity of the algorithms/analysis procedures.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on the phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.

60 APPLIED LIFE SCIENCES↗

Comparison of 3D dose distributions for HDR {sup 192}Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system

Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high–dose rate (HDR) iridium-192 ({sup 192}Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of {sup 192}Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with {sup 192}Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3 mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3 mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR {sup 192}Ir brachytherapy sources and 3D dose verification of TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutrinos from type Ia supernovae: The deflagration-to-detonation transition scenario

It has long been recognized that the neutrinos detected from the next core-collapse supernova in the Galaxy have the potential to reveal important information about the dynamics of the explosion and the nucleosynthesis conditions as well as allowing us to probe the properties of the neutrino itself. The neutrinos emitted from thermonuclear—type Ia—supernovae also possess the same potential, although these supernovae are dimmer neutrino sources. For the first time, we calculate the time, energy, line of sight, and neutrino-flavor-dependent features of the neutrino signal expected from a three-dimensional delayed-detonation explosion simulation, where a deflagration-to-detonation transition triggers the complete disruption of a near-Chandrasekhar mass carbon-oxygen white dwarf. We also calculate the neutrino flavor evolution along eight lines of sight through the simulation as a function of time and energy using an exact three-flavor transformation code. We identify a characteristic spectral peak at ˜10 MeV as a signature of electron captures on copper. This peak is a potentially distinguishing feature of explosion models since it reflects the nucleosynthesis conditions early in the explosion. We simulate the event rates in the Super-K, Hyper-K, JUNO, and DUNE neutrino detectors with the SNOwGLoBES event rate calculation software and also compute the IceCube signal. Hyper-K will be able to detect neutrinos from our model out to a distance of ˜10 kpc. Here, at 1 kpc, JUNO, Super-K, and DUNE would register a few events while IceCube and Hyper-K would register several tens of events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chapter 8: A 'Global' View on Bifacial Gain: Dependence on Geographic Location and Environmental Conditions

The simulation results presented in this chapter demonstrate how bifacial PV systems can bring a performance gain all around the globe, resolving a certain misbelief that they may only form a niche market restricted to specific locations or installations. Global predictions, based on irradiance, indicate bifacial gains in the order of 50% of the natural albedo for equator-facing systems with optimized tilt angle. In locations with low clearness index, the bifacial gain can even be higher. At system level the bifacial gain will be reduced by 20% to 50% relative to a free-standing panel, due to increased self-shading and to limitation of the diffuse irradiance on the rear by adjacent sheds. Even though the rear side irradiance of a bifacial module is inherently inhomogeneous, due to self-shading and external mounting structures, our simulations have shown that the RSD of the total irradiance does not exceed 5%, even at very high albedo, and will usually be much smaller. The simulation methods applied in this chapter and their ongoing integration into commercially available software tools, like PVsyst, will give system designers and installers more visibility on the configuration layout of a bifacial PV plant at their specific location, the associated bifacial gain and the effect on their return on investment.

14 SOLAR ENERGY↗

Integrated Resource and System Plannning Based on Energy Costs and Emission Analysis for a Sustainable Future

Efficient integration of renewable energy sources (RES) - such as wind, solar, geothermal, tidal, and wave - into the electric power grids can help improve energy security and contribute toward a sustainable energy future. To date, however, electric power grids are critically dependent on conventional sources, such as fossil fuels. Given the increasing penetration of RES and dynamic loads, there is a need to thoroughly reanalyze the performance of power grids in terms of cost, efficiency, and energy security. This paper presents a comprehensive analysis in terms of energy costs and emissions estimates of dynamic power grids incorporating various power-generating sources.

distributed energy resources↗

SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

How open data and interdisciplinary collaboration improve our understanding of space weather: A risk and resiliency perspective

Space weather refers to conditions around a star, like our Sun, and its interplanetary space that may affect space- and ground-based assets as well as human life. Space weather can manifest as many different phenomena, often simultaneously, and can create complex and sometimes dangerous conditions. The study of space weather is inherently trans-disciplinary, including subfields of solar, magnetospheric, ionospheric, and atmospheric research communities, but benefiting from collaborations with policymakers, industry, astrophysics, software engineering, and many more. Effective communication is required between scientists, the end-user community, and government organizations to ensure that we are prepared for any adverse space weather effects. With the rapid growth of the field in recent years, the upcoming Solar Cycle 25 maximum, and the evolution of research-ready technologies, we believe that space weather deserves a reexamination in terms of a “risk and resiliency” framework. By utilizing open data science, cross-disciplinary collaborations, information systems, and citizen science, we can forge stronger partnerships between science and industry and improve our readiness as a society to mitigate space weather impacts. The objective of this manuscript is to raise awareness of these concepts as we approach a solar maximum that coincides with an increasingly technology-dependent society, and introduce a unique way of approaching space weather through the lens of a risk and resiliency framework that can be used to further assess areas of improvement in the field.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling fission product diffusion in TRISO fuel particles with BISON

Diffusion of fission products in intact TRISO particles depends on particle geometry, fission product source rates, time, temperature, and temperature-dependent diffusion coefficients. Simulating this diffusion process requires models for source rates and diffusion coefficients, plus computation of the temperature field if not prescribed. In addition, simulation quality depends on discretization of the geometry, appropriate time stepping, and the accuracy of the solution method. In this paper, we explore the simulation of fission product diffusion in TRISO fuel particles using the finite element method via the fuel performance code Bison. Recent material model development has occurred in Bison for each material present in tri-structural isotropic (TRISO) fuel particles: the buffer, inner pyrolytic carbon, silicon carbide, and outer pyrolytic carbon layers, as well as the fuel kernel. Also, new mesh generation and fission product release fraction capabilities have been added. Diffusion capabilities are shown to converge to the correct solution via formal verification tests. A large number of code benchmarking problems are also given, with good results, showing that Bison’s computed release fractions closely match those of other software tools. Finally, a significant validation effort is detailed in which fission product release, measured as part of the AGR-1 capsule experiments, is compared to Bison outputs. Bison outputs compare very well to the experimental data and to PARFUME results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precipitation of aluminum nitride in a high strength maraging steel with low nitrogen content

In the present work, aluminum nitride (AlN) precipitation was investigated in a X23NiCoCrMoAl13-6-3 maraging steel with low nitrogen content (wt.% N = 5.5 ppm). A reliable and robust automatic method by scanning electron microscopy observations coupled with energy dispersive X-ray spectroscopy was developed for the quantification of AlN precipitates. The first stage was to identify the solvus temperature and to develop a heat treatment able to dissolve the AlN precipitates. The experimental determination of equilibrium conditions and solvus temperature show good agreement with ThermoCalc® simulation. Then, from this AlN-free state, the cooling rate, isothermal holding time and temperature were the subject of an intensive investigation in the austenite region of this maraging steel. In spite of the high temperatures used during heat treatments, the growth kinetic of the largest AlN precipitates (> 1 μm) is slow. The cooling rate has a major effect on the size and the number density of AlN due to a higher driving force for nucleation at low temperatures. At last, quenching prior to isothermal annealing at high temperatures leads to fine and dense AlN precipitation, resulting from the martensite to austenite transformation. Experimental results will be discussed and compared with kinetic data obtained with the mobility database MobFe2 implemented in Dictra® software. - Highlights: • Slow dissolution kinetic of AlN precipitates due to both their large size and small chemical driving force • Significant effects of cooling rate prior isothermal heat treatment, holding time and temperature on AlN precipitation • Size of AlN precipitates can be reduced by quenching prior isothermal holding. • Fine precipitation of AlN related to the α → γ transformation.

36 MATERIALS SCIENCE↗

Dynamic tumor tracking using the Elekta Agility MLC

Purpose: To evaluate the performance of the Elekta Agility multileaf collimator (MLC) for dynamic real-time tumor tracking. Methods: The authors have developed a new control software which interfaces to the Agility MLC to dynamically program the movement of individual leaves, the dynamic leaf guides (DLGs), and the Y collimators (“jaws”) based on the actual target trajectory. A motion platform was used to perform dynamic tracking experiments with sinusoidal trajectories. The actual target positions reported by the motion platform at 20, 30, or 40 Hz were used as shift vectors for the MLC in beams-eye-view. The system latency of the MLC (i.e., the average latency comprising target device reporting latencies and MLC adjustment latency) and the geometric tracking accuracy were extracted from a sequence of MV portal images acquired during irradiation for the following treatment scenarios: leaf-only motion, jaw + leaf motion, and DLG + leaf motion. Results: The portal imager measurements indicated a clear dependence of the system latency on the target position reporting frequency. Deducting the effect of the target frequency, the leaf adjustment latency was measured to be 38 ± 3 ms for a maximum target speed v of 13 mm/s. The jaw + leaf adjustment latency was 53 ± 3 at a similar speed. The system latency at a target position frequency of 30 Hz was in the range of 56–61 ms for the leaves (v ≤ 31 mm/s), 71–78 ms for the jaw + leaf motion (v ≤ 25 mm/s), and 58–72 ms for the DLG + leaf motion (v ≤ 59 mm/s). The tracking accuracy showed a similar dependency on the target position frequency and the maximum target speed. For the leaves, the root-mean-squared error (RMSE) was between 0.6–1.5 mm depending on the maximum target speed. For the jaw + leaf (DLG + leaf) motion, the RMSE was between 0.7–1.5 mm (1.9–3.4 mm). Conclusions: The authors have measured the latency and geometric accuracy of the Agility MLC, facilitating its future use for clinical tracking applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-604: Penumbra Characteristics of a New InCiseâ„¢ Multileaf Collimator of CyberKnife M6â„¢ System

Purpose: The InCise™ Multileaf Collimator (MLC) of CyberKnife M6™ System has been released recently. The purpose of this study was to explore the dosimetric characteristics of the new MLC. In particular, the penumbra characteristics of MLC fields at varying locations are evaluated. Methods: EBT3-based film measurements were performed with varying MLC fields ranging from 7.5 mm to 27.5 mm. Seventeen regions of interests (ROIs) were identified for irradiation. These are regions located at the central area (denoted as reference field), at the left/right edge areas of reference open field, at an intermediate location between central and edge area. Single beam treatment plans were designed by using the MultiPlan and was delivered using the Blue Phantom. Gafchromic films were irradiated at 1.5 cm depth in the Blue Phantom and analyzed using the Film Pro software. Variation of maximum dose, penumbra of MLC-defined fields, and symmetry/flatness were calculated as a function of locations of MLC fields. Results: The InCise™ MLC System showed relatively consistent dose distribution and penumbra size with varying locations of MLC fields. The measured maximum dose varied within 5 % at different locations compared to that at the central location and agreed with the calculated data well within 2%. The measured penumbrae were in the range of 2.9 mm and 3.7 mm and were relatively consistent regardless of locations. However, dose profiles in the out-of-field and in-field regions varied with locations and field sizes. Strong variation was seen for all fields located at 55 mm away from the central field. The MLC leakage map showed that the leakage is dependent on position. Conclusion: The size of penumbra and normalized maximum dose for MLC-defined fields were consistent in different regions of MLC. However, dose profiles in the out-field region varied with locations and field sizes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decaf: Decoupled Dataflows for In Situ High-Performance Workflows

Decaf is a dataflow system for the parallel communication of coupled tasks in an HPC workflow. The dataflow can perform arbitrary data transformations ranging from simply forwarding data to complex data redistribution. Decaf does this by allowing the user to allocate resources and execute custom code in the dataflow. All communication through the dataflow is efficient parallel message passing over MPI. The runtime for calling tasks is entirely message-driven; Decaf executes a task when all messages for the task have been received. Such a messagedriven runtime allows cyclic task dependencies in the workflow graph, for example, to enact computational steering based on the result of downstream tasks. Decaf includes a simple Python API for describing the workflow graph. This allows Decaf to stand alone as a complete workflow system, but Decaf can also be used as the dataflow layer by one or more other workflow systems to form a heterogeneous task-based computing environment. In one experiment, we couple a molecular dynamics code with a visualization tool using the FlowVR and Damaris workflow systems and Decaf for the dataflow. In another experiment, we test the coupling of a cosmology code with Voronoi tessellation and density estimation codes using MPI for the simulation, the DIY programming model for the two analysis codes, and Decaf for the dataflow. Such workflows consisting of heterogeneous software infrastructures exist because components are developed separately with different programming models and runtimes, and this is the first time that such heterogeneous coupling of diverse components was demonstrated in situ on HPC systems.

97 MATHEMATICS AND COMPUTING↗