Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Poly (lactide-co-glycolide) acid nanoencapsulation of a synthetic coumarin: Cytotoxicity and bio-distribution in mice, in cancer cell line and interaction with calf thymus DNA as target

Several naturally occurring coumarin compounds, including scopoletin (7 hydroxy-6 methoxycoumarin), of plant origin have been reported to have anti-cancer potentials. A related but chemically synthesized coumarin, 4-methyl-7-hydroxy coumarin (SC), was also shown to have similar anti-cancer potentials. In the present study, to test if nano-encapsulated SC could be a more potent anti-cancer agent, we encapsulated SC with poly lactide-co-glycolide acid (PLGA) nanoparticles (Nano Coumarin; NC) and tested its potentials with a variety of protocols. NC demonstrated greater efficiency of drug uptake and showed anti-cancer potentials in melanoma cell line A375, as revealed from scanning electronic and atomic force microscopies. To test its possible interaction with target DNA, the combined data of circular dichroism spectra (CD) and melting temperature profile (T{sub m}) of calf thymus DNA treated with NC were analyzed. Results indicated a concentration dependent interaction of NC with calf thymus DNA, bringing in effective change in structure and conformation, and forming a new complex that increased its stability. Particle size and morphology of NC determined through polydispersity index and zeta potential using dynamic light scattering qualified NC to be a more potent anti-cancer agent than SC. Further, SC and NC showed negligible cytotoxic effects on normal skin cells and peripheral blood mononuclear cells of mice. Distribution assay of PLGA nanoparticles in different tissues like brain, heart, kidneys, liver, lungs, and spleen in mice revealed the presence of nanoparticles in different tissues including brain, indicating that the particles could cross the blood brain barrier, significant information for drug design. - Graphical abstract: Nanoencapsulated coumarin (NC) were characterized for their size and morphology by scanning electron (SEM) and atomic force microscopies (AFM).The physical interaction of the NC with calf thymus DNA was studied through circular dichroism (CD) spectroscopies, using UV-visible titration and thermal denaturation studies. NC had a concentration dependent interaction with calf thymus DNA, could form a new complex with double helical DNA, increased the T{sub m} value and altered CD spectra of DNA and showed stronger anti-cancer effect than synthetic coumarin. Display Omitted Research Highlights: > Strategy for PLGA nano-encapsulation of a bioactive synthetic coumarin, 4 methyl 7 hydroxy coumarin (SC) is formulated. > Anti-cancer potentials of nano-encapsulated SC (NC) are evaluated in skin papilloma cells A375 through standard protocols. > Data of CD and Tm indicate concentration dependent interactions of NC bringing conformational changes in target DNA. > Particle size of NC and physico-chemical interactions with target DNA show NC as a more potent anti-cancer drug than SC. > NC has less cytotoxic effects, and can cross the blood brain barrier - important features for strategic drug design.

60 APPLIED LIFE SCIENCES↗

Cell-level reliability testing procedures for CIGS photovoltaics

The reliability of photovoltaics is commonly studied at the module level. Many reliability problems originate from module attributes, such as metal interconnections to cells, junction boxes. However, significant work in reliability can also be done prior to module design. Testing for reliability earlier in the research cycle increases the probability of avoiding common module reliability problems before cell changes are implemented on a large scale. Cell-level reliability studies can thus lower the rates of module failures in the field and provide confidence to investors that new technologies will perform as advertised. This report summarizes how we investigated three reliability concerns in Cu(In,Ga)Se 2 (CIGS) photovoltaics at the cell level: metastability, shading-induced damage, and potential-induced degradation (PID). We find that examining these concerns required developing robust measurement protocols including the fabrication of novel testing structures. This information will allow readers to incorporate sound metrics for investigating reliability phenomena and aid their studies of cell and module reliability improvements.

14 SOLAR ENERGY↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The difference between “equivalent” and “not different”

Often, experimenters wish to establish that populations of units can be considered equivalent to each other, in order to leverage improved knowledge about one population for characterizing the new population, or to establish the comparability of items. Equivalence tests have existed for many years, but their use in industry seems to have been largely restricted to biomedical applications, such as for assessing the equivalence of two drugs or protocols. We present the fundamentals of equivalence tests, compare them to traditional two-sample and ANOVA tests that are better suited to establishing differences in populations, and propose the use of a graphical summary to compare p-values across different thresholds of practically important differences.

97 MATHEMATICS AND COMPUTING↗

Results from an International Interlaboratory Study on Light- and Elevated Temperature-Induced Degradation (LETID) in Solar Modules

This presentation reports recently submitted results from an international interlaboratory comparison study on light- and elevated temperature-induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection, and screen a large and diverse set of prototype modules for LETID. We summarize the range of observed degradation and provide initial conclusions on the reproducibility of results across labs. In LETID-sensitive modules, both open-circuit voltage (VOC) and short-circuit current (ISC) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the direct LETID-related losses. We summarize the conclusions drawn from the study, provide an update on a forthcoming standard technical specification for LETID testing of PV modules (IEC TS 63342 ED1), and discuss unresolved questions and potential future work on LETID in PV modules.

degradation↗

A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth

In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.

Viso, M.↗

A pilot study on the feasibility of European harmonized human biomonitoring: Strategies towards a common approach, challenges and opportunities

In 2004 the European Commission and Member States initiated activities towards a harmonized approach for Human Biomonitoring surveys throughout Europe. The main objective was to sustain environmental health policy by building a coherent and sustainable framework and by increasing the comparability of data across countries. A pilot study to test common guidelines for setting up surveys was considered a key step in this process. Through a bottom-up approach that included all stakeholders, a joint study protocol was elaborated. From September 2011 till February 2012, 17 European countries collected data from 1844 mother–child pairs in the frame of DEMOnstration of a study to COordinate and Perform Human Biomonitoring on a European Scale (DEMOCOPHES). Mercury in hair and urinary cadmium and cotinine were selected as biomarkers of exposure covered by sufficient analytical experience. Phthalate metabolites and Bisphenol A in urine were added to take into account increasing public and political awareness for emerging types of contaminants and to test less advanced markers/markers covered by less analytical experience. Extensive efforts towards chemo-analytical comparability were included. The pilot study showed that common approaches can be found in a context of considerable differences with respect to experience and expertize, socio-cultural background, economic situation and national priorities. It also evidenced that comparable Human Biomonitoring results can be obtained in such context. A European network was built, exchanging information, expertize and experiences, and providing training on all aspects of a survey. A key challenge was finding the right balance between a rigid structure allowing maximal comparability and a flexible approach increasing feasibility and capacity building. Next steps in European harmonization in Human Biomonitoring surveys include the establishment of a joint process for prioritization of substances to cover and biomarkers to develop, linking biomonitoring surveys with health examination surveys and with research, and coping with the diverse implementations of EU regulations and international guidelines with respect to ethics and privacy. - Highlights: • A common European Human Biomonitoring (HBM) survey protocol was developed through a bottom-up approach. • A joint process for prioritization was established to select a limited set of biomarkers, some covered by experience and others for emerging substances. • The protocol was tested in a pilot study, resulting in HBM results comparable on a European scale which sustained environmental health policy. • Ethics and privacy regulations were not an obstacle for transnational harmonization.

54 ENVIRONMENTAL SCIENCES↗

Semi-device-independent random-number expansion without entanglement

By testing the classical correlation violation between two systems, true random numbers can be generated and certified without applying classical statistical method. In this work, we propose a true random-number expansion protocol without entanglement, where the randomness can be guaranteed only by the two-dimensional quantum witness violation. Furthermore, we only assume that the dimensionality of the system used in the protocol has a tight bound, and the whole protocol can be regarded as a semi-device-independent black-box scenario. Compared with the device-independent random-number expansion protocol based on entanglement, our protocol is much easier to implement and test.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mimicking Martian dust: An in-vacuum dust deposition system for testing the ultraviolet sensors on the Curiosity rover

We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severely affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Structure Construction Capability Year One Accomplishments

The Microwave Structure Construction Capability (MSCC) element, part of the Moon to Mars Planetary Autonomous Construction Project (MMPACT) was initiated in 2020. MSCC is responsible for creating horizontal and vertical infrastructure on the moon using microwave energy. Microwave energy was selected since it is the only method to volumetrically heat the regolith. All other sintering/melting methods rely on thermal conduction through the very low conductivity surface, resulting in an inefficient process. Advances were achieved in materials characterization and understanding, microwave sintering in vacuum, and microwave design and analyses. Two dielectric property testing systems have been developed at Radiance Technologies and JPL. These will examine dielectric properties at cryogenic temperatures and over a broad frequency range. Permittivity and permeability testing at -60 ̊C in vacuum from 0.05 to 3 GHz has been generated at JPL. Additional modifications will be made to go to -190 ̊C (LN2). Radiance Technologies created a test system to measure dielectric properties at greater than 10 GHz and initiated work on developing a vacuum capable, portable test system to measure dielectric properties of Apollo regolith and simulants from 100 MHz to 18 GHz. These tests are to identify optimal heating frequencies and protocols. During microwave sintering at about 1100 ̊C, volatiles were creating difficulty in achieving a reasonably dense specimen. Due to processing in vacuum and the nature of the lunar regolith, some volatiles and porosity are expected. However, the Earth produced simulants have non-lunar materials in them that create volatiles that aren’t representative of lunar regolith. Therefore, a five month effort was conducted to establish a heat treat method to remove these non-lunar materials. Tests were conducted using TGA mass spectrometry, heating in vacuum and conducting mass spectrometry, dielectric and DTA, Raman, BET, particle size analysis, morphological analysis, carbon and sulfur chemical content determination and microscopy. The process has been scaled-up to 6 kg batch size and undergoing evaluation. A 36 kg batch size is the target for JSC-1A and other limited availability simulants. These calcining protocols will be standard for NASA and beyond. MSCC has also created scalable processes for fabricating synthetic lunar materials. Processes to fabricate Anorthite (plagioclase CaAl2Si2O8), Diopside (pyroxene CaMgSi₂O₆), and Enstatite (pyroxene Mg2Si2O6) have been generated. These materials will enable generation of microwave sintering models to bound various composition ranges anticipated on the Moon, therefore mitigating the need for a precise simulant with respect to location on the Moon. Successful microwave sintering in air using a horn applicator was demonstrated. All previous microwave vacuum sintering in the literature was at small scale and in a contained enclosure thus taking advantage of reflections. This is the first to use a lunar like microwave applicator to sinter ceramic in a bed as it would be done on the Moon. Small scale and inert sintering were conducted to assist in developing protocols with quicker turnaround times than larger scale testing. Testing has anchored thermal analysis predicting heat flow in vacuum during microwave sintering. Thermal conductivity testing was also initiated. Microwave coupling to the regolith has been modeled by multiple organizations and with different software packages. At least six horn designs and applicator configurations for both magnetron and solid state sources are being examined. Optimal simulant container designs for microwaves have also been generated. The power and electronics design for the solid state microwave system has been initiated. Concept designs for a lander based microwave sintering have been evaluated.

microwave↗

Fractionated External Beam Radiotherapy as a Suitable Preparative Regimen for Hepatocyte Transplantation After Partial Hepatectomy

Purpose: Hepatocyte transplantation is strongly considered to be a promising option to correct chronic liver failure through repopulation of the diseased organ. We already reported on extensive liver repopulation by hepatocytes transplanted into rats preconditioned with 25-Gy single dose selective external beam irradiation (IR). Herein, we tested lower radiation doses and fractionated protocols, which would be applicable in clinical use. Methods and Material: Livers of dipeptidylpeptidase IV (DPPIV)-deficient rats were preconditioned with partial liver external beam single dose IR at 25 Gy, 8 Gy, or 5 Gy, or fractionated IR at 5 x 5 Gy or 5 x 2 Gy. Four days after completion of IR, a partial hepatectomy (PH) was performed to resect the untreated liver section. Subsequently, 12 million wild-type (DPPIV{sup +}) hepatocytes were transplanted via the spleen into the recipient livers. The degree of donor cell integration and liver repopulation was studied 16 weeks after transplantation by means of immunofluorescence and DPPIV-luminescence assay. Results: Donor hepatocyte integration and liver repopulation were more effective in the irradiated livers following pretreatment with the IR doses 1 x 25 Gy and 5 x 5 Gy (formation of large DPPIV-positive cell clusters) than single-dose irradiation at 8 Gy or 5 Gy (DPPIV-positive clusters noticeably smaller and less frequent). Quantitative analysis of extracted DPPIV revealed signals exceeding the control level in all transplanted animals treated with IR and PH. Compared with the standard treatment of 1 x 25 Gy, fractionation with 5 x 5 Gy was equally efficacious, the Mann-Whitney U test disclosing no statistically significant difference (p = 0.146). The lower doses of 1 x 5 Gy, 1 x 8 Gy, and 5 x 2 Gy were significantly less effective with p < 0.05. Conclusion: This study suggests that fractionated radiotherapy in combination with PH is a conceivable pretreatment approach to prime the host liver for hepatocyte transplantation, thus bringing the experimental model a step closer to clinical application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joint Architecture Standard (JAS) Reliable Data Delivery Protocol (RDDP) specification.

The Joint Architecture Standard (JAS) program at Sandia National Laboratories requires the use of a reliable data delivery protocol over SpaceWire. The National Aeronautics and Space Administration at the Goddard Spaceflight Center in Greenbelt, Maryland, developed and specified a reliable protocol for its Geostationary Operational Environment Satellite known as GOES-R Reliable Data Delivery Protocol (GRDDP). The JAS program implemented and tested GRDDP and then suggested a number of modifications to the original specification to meet its program specific requirements. This document details the full RDDP specification as modified for JAS. The JAS Reliable Data Delivery Protocol uses the lower-level SpaceWire data link layer to provide reliable packet delivery services to one or more higher-level host application processes. This document specifies the functional requirements for JRDDP but does not specify the interfaces to the lower- or higher-level processes, which may be implementation-dependent.

99 GENERAL AND MISCELLANEOUS↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Survival analysis of the CEAwatch multicentre clustered randomized trial

Abstract Background The CEAwatch randomized trial showed that follow-up with intensive carcinoembryonic antigen (CEA) monitoring (CEAwatch protocol) was better than care as usual (CAU) for early postoperative detection of colorectal cancer recurrence. The aim of this study was to calculate overall survival (OS) and disease-specific survival (DSS). Methods For all patients with recurrence, OS and DSS were compared between patients detected by the CEAwatch protocol versus CAU, and by the method of detection of recurrence, using Cox regression models. Results Some 238 patients with recurrence were analysed (7·5 per cent); a total of 108 recurrences were detected by CEA blood test, 64 (55·2 per cent) within the CEAwatch protocol and 44 (41·9 per cent) in the CAU group (P = 0·007). Only 16 recurrences (13·8 per cent) were detected by patient self-report in the CEAwatch group, compared with 33 (31·4 per cent) in the CAU group. There was no significant improvement in either OS or DSS with the CEAwatch protocol compared with CAU : hazard ratio 0·73 (95 per cent 0·46 to 1·17) and 0·78 (0·48 to 1·28) respectively. There were no differences in survival when recurrence was detected by CT versus CEA measurement, but both of these methods yielded better survival outcomes than detection by patient self-report. Conclusion There was no direct survival benefit in favour of the intensive programme, but the CEAwatch protocol led to a higher proportion of recurrences being detected by CEA -based blood test and reduced the number detected by patient self-report. This is important because detection of recurrence by blood test was associated with significantly better survival than patient self-report, indirectly supporting use of the CEAwatch protocol.

Verberne, C. J.↗

Validation of Decompression Sickness Risk Mitigation Protocols for Planetary Spaceflight Missions

BACKGROUND: Apollo missions used a 100% O2 cabin atmosphere which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activity (EVA) on the moon. NASA’s future missions to the moon and Mars are expected to use nitrox gas mixtures of up to 34% O2, 66% N2, which will reduce flammability risk compared with Apollo, but will necessitate Oxygen prebreathe prior to EVA to reduce DCS risk to acceptable levels. Prebreathe protocols used on the space shuttle and International Space Station are validated for microgravity EVAs, but the significantly increased risk of DCS during equivalent ambulatory EVAs make these protocols inapplicable to planetary EVA. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA as a compromise that balances prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. However, this atmosphere may not be used for vehicles that do not support frequent EVA, and with commercial providers and international providers expected to provide landers, pressurized rovers, habitats, and spacesuits, different combinations of vehicle and spacesuit atmospheres are possible and will each require validated prebreathe protocols. OVERVIEW: Key components of a multi-year strategic roadmap include: 1) Establish hypobaric chamber facility capable of supporting 8-person EVA prebreathe validation tests at saturation atmospheres up to 36% O2; 2) validate an EVA physical workload simulation for use during prebreathe validation testing; 3) validate the recommended “exploration atmosphere” prebreathe protocol; 4) validate prebreathe protocols for additional atmospheric combinations that bound the most likely potential operating ranges of future vehicles and spacesuits; and 5) update DCS risk estimation models based on results of prebreathe validation studies. DISCUSSION: Details and data from completion of the first two steps of the strategic roadmap will be presented; the third step is currently underway, with pilot results provided in a companion presentation. Steps four and five will require a multi-year series of chamber tests; collaborations are being pursued.

Andrew F. J. Abercromby↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗

Interactions of Mean Climate Change and Climate Variability on Food Security Extremes

Recognizing that climate change will affect agricultural systems both through mean changes and through shifts in climate variability and associated extreme events, we present preliminary analyses of climate impacts from a network of 1137 crop modeling sites contributed to the AgMIP Coordinated Climate-Crop Modeling Project (C3MP). At each site sensitivity tests were run according to a common protocol, which enables the fitting of crop model emulators across a range of carbon dioxide, temperature, and water (CTW) changes. C3MP can elucidate several aspects of these changes and quantify crop responses across a wide diversity of farming systems. Here we test the hypothesis that climate change and variability interact in three main ways. First, mean climate changes can affect yields across an entire time period. Second, extreme events (when they do occur) may be more sensitive to climate changes than a year with normal climate. Third, mean climate changes can alter the likelihood of climate extremes, leading to more frequent seasons with anomalies outside of the expected conditions for which management was designed. In this way, shifts in climate variability can result in an increase or reduction of mean yield, as extreme climate events tend to have lower yield than years with normal climate.C3MP maize simulations across 126 farms reveal a clear indication and quantification (as response functions) of mean climate impacts on mean yield and clearly show that mean climate changes will directly affect the variability of yield. Yield reductions from increased climate variability are not as clear as crop models tend to be less sensitive to dangers on the cool and wet extremes of climate variability, likely underestimating losses from water-logging, floods, and frosts.

Variability↗