Modeling Control Strategies and Range Impacts for Electric Vehicle Integrated Thermal Management Systems with MATLAB/Simulink

The National Renewable Energy Laboratory's (NREL's) CoolSim MATLAB/Simulink modeling framework was used to explore control strategies for an electric vehicle combined loop system. Three system variants of increased complexity and efficiency were explored: a glycol-based positive temperature coefficient heater (PTC), PTC with power electronics and electric motor (PEEM) waste heat recovery, and PTC with PEEM waste heat recovery plus heat pump versions. Additionally, the benefit of electric motor preheating was considered. A two-level control strategy was developed where the mode selection and component control were treated separately. Only the parameters typically available by vehicle sensors were used to control the system. The control approach included a mode selection algorithm and controllers for the compressor speed, cabin blower flow rate, coolant flow rate, and the front-end heat exchanger coolant bypass rate. The electric motor was bypassed by the cooling circuit until its temperature exceeded the coolant inlet temperature. The impact of these thermal systems on electric vehicle range during warmup was simulated for the Urban Dynamometer Driving Schedule (UDDS) and Highway Fuel Economy Test (HWFET2X) drive cycles weighted 45%/55% respectively. A range of ambient temperatures from -20 degrees C to +20 degrees C was considered. NREL's Future Automotive Systems Technology Simulator (FASTSim) vehicle modeling tool showed up to a 10.9% improvement in range for the full system over the baseline during warmup from cold soak. The full system with preheat showed up to 17% improvement in range.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a liquid heat exchange circuit. The system includes at least one battery in thermal communication with the liquid heat exchange circuit. The system includes a controller operatively connected to the liquid heat exchange circuit. The controller is configured and adapted to variably select whether heat will be rejected to the liquid heat exchange circuit. The system includes at least one heat exchanger positioned on the liquid heat exchange circuit. The at least one heat exchanger is a liquid-air heat exchanger or a liquid-liquid heat exchanger. A method for controlling a thermal management system for an air vehicle includes determining an expected temperature of at least one battery, and cooling the at least one battery with a cooling device if the expected temperature exceeds a pre-determined expected temperature threshold.

Rheaume, Jonathan↗

Summary of Oxy Boiler Design Guidelines and Design Considerations (Topical Report- Recovery Act: Oxy-Combustion Technology Development for Industrial-Scale Boiler Applications)

This Topical Report outlines guidelines and key considerations for design and operation of pulverized coal-fired boilers for oxy-combustion. The scope addressed includes only the boiler island, not the entire oxy-fired CO 2 capture plant. These guidelines are primarily developed for tangential-fired boilers and focus on designs capable of dual air and oxy-fired operation. The guidelines and considerations discussed are applicable to both new units and existing boiler retrofits. These guidelines are largely based on the findings from the extensive 15 MW th pilot testing and design efforts conducted under this project. A summary level description is provided for each major aspect of boiler design impacted by oxy-combustion, and key considerations are discussed for broader application to different utility and industrial designs. Guidelines address the boiler system arrangement, firing system, boiler thermal design, ducting, materials, control system, and other key systems.

42 ENGINEERING↗

Energy Efficient Engine Preliminary Design and Integration Studies

The technology and configurational requirements of an all new 1990's energy efficient turbofan engine having a twin spool arrangement with a directly coupled fan and low-pressure turbine, a mixed exhaust nacelle, and a high 38.6:1 overall pressure ratio were studied. Major advanced technology design features required to provide the overall benefits were a high pressure ratio compression system, a thermally actuated advanced clearance control system, lightweight shroudless fan blades, a low maintenance cost one-stage high pressure turbine, a short efficient mixer and structurally integrated engine and nacelle. A conceptual design analysis was followed by integration and performance analyses of geared and direct-drive fan engines with separate or mixed exhaust nacelles to refine previously designed engine cycles. Preliminary design and more detailed engine-aircraft integration analysis were then conducted on the more promising configurations. Engine and aircraft sizing, fuel burned, and airframe noise studies on projected 1990's domestic and international aircraft produced sufficient definition of configurational and advanced technology requirements to allow immediate initiation of component technology development.

Gray, D. E.↗

Thermal Actuator Identification and Control for Thermomechanical Real-Time Cyber–Physical Testing

Thermomechanical cyber–physical testing enables two-way thermal coupling between a numerical and an experimental subsystem. The interactions between the numerical model and the physical specimen occur through transfer systems, which enforce interface conditions. Thus, efficient control methodologies are necessary to achieve the desired interface interaction through thermal actuators with minimal error. This study introduces a novel thermal transfer system that imposes distributed cooling (or heating) thermal loads on a physical subsystem. First, the thermal actuator is identified considering switching-mode continuous dynamics for heating and cooling conditions. A switching-mode estimation algorithm is adopted to estimate the operating thermal cycle of the actuator in real-time. A control system is developed to experimentally impose the desired temperature and reduce tracking error (i.e., the error between the desired and actual temperature) under different thermal cycles. The identification and control of the thermal transfer system are then validated through a set of experiments considering different temperature rates of change. The developed control system is found to effectively minimize tracking errors in real-time cyber–physical experiments.

Herta Montoya↗

Numerical Implementation of Source Terms to Evaluate Active Porosity Control using a Transpiration Cooled Thermal Protection System

Transpiration cooling has renewed interest of study as a renewable system of thermal protection for atmospheric entry systems. The presence of coolant within the void space of a porous material changes its effective porosity and theorized to lend the external heatshield as a potential means of porous surface control. Effective porosity is explored in two forms: saturation of void space where exiting coolant creates ‘blowing’ over the surface, and partial evacuation of the void space where withdrawal of the coolant creates ‘suction’ on the surface. Thus this study evaluates using transpiration cooling as a as means of active aerodynamic control. The feasibility of the system is evaluated numerically using Reynolds-averaged Navier Stokes based computational fluid dynamics for the aerodynamic assessments by coding source terms of transpiration cooling products at a heat shield surface boundary at the wind side shoulder, creating an asymmetric scheme. Study results show induced moments about the pitch axis incurred following the source terms of a cooling fluid at a near-shoulder location on the heat shield. Lift and drag saw increasing modulation with increase in mass flux rate. Pitch moment was altered a total of 388 N-m between lowest and highest ‘suction’ rates and changed 194 N-m maximum between ‘blowing’ rates.

transpiration cooling↗

The Submillimeter Wave Astronomy Satellite (SWAS) solar array system

The SWAS (Submillimeter Wave Astronomy Satellite) solar array system is described. It is an innovative approach to meet the missions requirements. The SWAS satellite provides a three axis stabilized platform to survey a variety of galactic cloud structures. This system includes highly reliable, lightweight launch latch, deployment, and lock mechanisms, and solar array panels that provide the maximum solar cell area. The design of the solar arrays are the result of system trades that included instrument and spacecraft thermal constraints, attitude control system maneuvering rates and pointing accuracies, the power system, and the spacecraft structure.

Sneiderman, Gary↗

Post Irradiation Evaluation of Thermal Control Coatings and Solid Lubricants to Support Fission Surface Power Systems

The development of a nuclear power system for space missions, such as the Jupiter Icy Moons Orbiter or a lunar outpost, requires substantially more compact reactor design than conventional terrestrial systems. In order to minimize shielding requirements and hence system weight, the radiation tolerance of component materials within the power conversion and heat rejection systems must be defined. Two classes of coatings, thermal control paints and solid lubricants, were identified as material systems for which limited radiation hardness information was available. Screening studies were designed to explore candidate coatings under a predominately fast neutron spectrum. The Ohio State Research Reactor Facility staff performed irradiation in a well characterized, mixed energy spectrum and performed post irradiation analysis of representative coatings for thermal control and solid lubricant applications. Thermal control paints were evaluated for 1 MeV equivalent fluences from 10(exp 13) to 10(exp 15) n per square centimeters. No optical degradation was noted although some adhesive degradation was found at higher fluence levels. Solid lubricant coatings were evaluated for 1 MeV equivalent fluences from 10(exp 15) to 10(exp 16) n per square centimeters with coating adhesion and flexibility used for post irradiation evaluation screening. The exposures studied did not lead to obvious property degradation indicating the coatings would have survived the radiation environment for the previously proposed Jupiter mission. The results are also applicable to space power development programs such as fission surface power for future lunar and Mars missions.

Bowman, Cheryl L.↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗

Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

Izenson, Michael↗

SPC-2734 Chromalox Oil Heater System Procurement Specification

This specification will supply the necessary technical information to the vendor to allow them to provide the system we need for the Thermal Energy Delivery System (TEDS) construction. TEDS is being constructed within the dynamic energy transport and integration laboratory (DETAIL) facility to test heat transfer components, distribution systems, instruments, and controls that can be monitored and controlled for hybrid generation of electrical power and/or non-electrical products. TEDS is designed to operate as a part of an integrated system or independently to demonstrate component operations, to develop and validate thermal energy transport models and control systems, and to study thermal energy inertia and storage. Within the integrated system, TEDS will be connected to the INL Real Time Digital Simulator (RTDS) test platform to develop and demonstrate monitoring and control systems and to investigate real-time, hardware-in-the-loop response characteristics relative to grid operations. As the basis of the TEDS, Chromalox (the vendor) has been chosen to design and supply a heater, pump, storage tanks, and pressure vessel due to their experience with industrial-scale heat transfer oil systems.

25 ENERGY STORAGE↗

Topology, Design, Analysis, and Thermal Management of Power Electronics for Hybrid Electric Vehicle Applications

Power electronics circuits play an important role in the success of electric, hybrid and fuel cell vehicles. Typical power electronics circuits in hybrid vehicles include electric motor drive circuits and DC/DC converter circuits. Conventional circuit topologies, such as buck converters, voltage source inverters and bidirectional boost converters are challenged by system cost, efficiency, controllability, thermal management, voltage and current capability, and packaging issues. Novel topologies, such as isolated bidirectional DC/DC converters, multilevel converters, and Z-source inverters, offer potential improvement to hybrid vehicle system performance, extended controllability and power capabilities. This paper gives an overview of the topologies, design, and thermal management, and control of power electronics circuits in hybrid vehicle applications.

08 HYDROGEN↗

Control mechanism for attenuation of thermal energy pulses using cold circulators in the cryogenic distribution system of fusion devices in tokamak configuration

Operation and control of superconducting (SC) magnets in the fusion devices having tokamak configuration opens up the domain of varying peak thermal energy environment as a function of time, commensurate with the plasma pulses. The varied thermal energy environment, thus propagated to upstream of the cooling system, is responsible for the system level instability of the overall cryogenic system. The cryogenic distribution system, the regime of first impact point, therefore, has to be tuned so as to stay at the nearly stable zone of operation. The configuration of the cryogenic distribution system, considered in the present study, involves a liquid helium (LHe) bath as a thermal buffer, LHe submerged heat exchangers and cold circulator apart from the valves for implementations of the precise controls. The cold circulator supplies the forced flow supercritical helium, used for the cooling of SC magnets. The transients of the thermal energy pulses can be attenuated in the cryogenic distribution system by various methodologies. One of the adopted methodologies in the present study is with the precise speed control of the cold circulators. The adopted methodology is applied to various configurations of arrangements of internal components in the distribution system for obtaining system responses with superior attenuation of energy pulses. The process simulation approach, assumptions, considered inputs and constraints, process modeling with different configuration as well as results to accomplish the control scheme for the attenuation of the thermal energy pulses are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Effect of Vehicle Platooning on the Optimal Control of a Heavy Duty Engine Thermal System

One promising method for reducing fuel consumption and emissions, particularly in heavy duty trucks, is platooning. As the distance between vehicles decreases, the following vehicles will experience less aerodynamic drag on the front of the vehicle. However, reducing the velocity of the air contacting the front of the vehicle could have adverse effects on the temperature of the engine. To compensate for this effect, the energy consumption of the engine cooling system might increase, ultimately limiting the overall improvements obtained with platooning. Understanding the coupling between drag reduction and engine cooling load requirement is key for successfully implementing platooning strategies. Additionally, in a Connected and Automated Vehicle (CAV) environment, where information of the future engine load becomes available, the operation of the cooling system can be optimized in order to achieve the maximum fuel consumption reduction. In this paper, a control-oriented physics-based model for the engine cooling loop of a Volvo engine is developed and validated against road data. Starting from the validated model, an optimal control problem for the coolant system is formulated considering the tradeoff between the tracking of the engine temperature setpoint and the corresponding fuel consumption under different trailing distances. To compare the coolant system performance, Dynamic Programming (DP) is used to determine the global optimal solution for the coolant system actuator. The coupling between optimal cooling system operation and reduction in ram air are evaluated by comparing the results obtained from the DP under different platooning conditions against the unrestricted scenario. In addition, the paper analyzes the changes in the tradeoff between fuel consumption and setpoint tracking for different vehicle distances. This analysis will provide useful insight on the sensitivity of the coolant system controller calibration to the platoon distance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytical Review of Exploration Extravehicular Mobility Unit Heat Rejection Performance

The Primary Thermal Control Loop (PTCL) in the Exploration Extravehicular Mobility Unit (xEMU) uses a Spacesuit Water Membrane Evaporator (SWME) to provide cooling for the crew member and spacesuit avionics. A secondary emergency cooling system, the Auxiliary Thermal Control Loop (ATCL), also uses a smaller version of the SWME, called the Mini-ME, in the event of a failure in the primary system. These are integral to the comfort of the crew member (through heat rejection) during an Extravehicular Activity (EVA). This paper examines the effectiveness of the heat rejection of the PTCL and the ATCL during thermal vacuum testing and the absolute limit of heat rejection to maintain an approximately 10C outlet temperature. During this thermal vacuum test, the PTCL was taken from a heat input of 0W up to 900W, far past the design point, and the ATCL was tested from 0W to 300W. Testing showed that the PTCL and the ATCL can maintain crew member outlet temperature throughout an entire 8-hour thermally controlled EVA environment (hot and cold). The results and effectiveness of the test will be detailed throughout this paper for all EVAs (whether a full mapping profile or a standard continuous heat load).

PLSS↗

Spacecraft Design Thermal Control Subsystem

This slide presentation reviews the functions of the thermal control subsystem engineers in the design of spacecraft. The goal of the thermal control subsystem that will be used in a spacecraft is to maintain the temperature of all spacecraft components, subsystems, and all the flight systems within specified limits for all flight modes from launch to the end of the mission. For most thermal control subsystems the mass, power and control and sensing systems must be kept below 10% of the total flight system resources. This means that the thermal control engineer is involved in all other flight systems designs. The two concepts of thermal control, passive and active are reviewed and the use of thermal modeling tools are explained. The testing of the thermal control is also reviewed.

thermal control↗

Renovation of Thermal Vacuum Chambers at Idaho National Laboratory (INL) for Testing of Radioisotope Power Systems (RPS)

The Radioisotope Power Systems (RPS) program at Idaho National Laboratory (INL) fuels and performs environmental testing of RPS in support of National Aeronautics and Space Administration (NASA) missions. Recently the programs’ thermal vacuum chambers, housed within INL’s Space and Security Power Systems Facility (SSPSF), underwent successful renovations to improve functional capabilities and system control in support of customer missions. Thermal vacuum system renovations focused primarily on three core functions. The first focus area was integration of semi-automated Programmable Logic Controllers (PLC) to enhance operational feedback and process control. This included the use of numerically controlled vacuum valves and integration of real time feedback from process pressure transducers. Improvements to the system high vacuum pumping technology was the second priority focus. Legacy diffusion pumps were replaced with turbo-molecular and cryogenic pumps to help mitigate the possibility of back streaming diffusion pump oil onto the surface of the test article or radiative cooling surfaces located within the chambers. The third and final core function involved meeting emergent customer thermal requirements. This led to retro-fitting one of the vacuum chambers with a cryogenically cooled Thermal Conditioning Unit (TCU) and thermal shrouds. The TCU utilizes gaseous nitrogen to heat or cool a cylindrical shroud to maintain a set temperature with a programmable range of -I85 °C to I00 °C. With the successful completion of RPS acceptance testing, the newly renovated thermal vacuum chamber systems are operational and better equipped to support testing of Radioisotope Power Systems for space exploration missions.