Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

SN 2020bvc: A Broad-line Type Ic Supernova with a Double-peaked Optical Light Curve and a Luminous X-Ray and Radio Counterpart

Here, we present optical, radio, and X-ray observations of SN 2020bvc (=ASASSN20bs; ZTF20aalxlis), a nearby (z = 0.0252; d = 114 Mpc) broad-lined (BL) Type Ic supernova (SN) and the first double-peaked Ic-BL discovered without a gamma-ray burst (GRB) trigger. Our observations show that SN 2020bvc shares several properties in common with the Ic-BL SN 2006aj, which was associated with the low-luminosity gamma-ray burst (LLGRB) 060218. First, the 10 GHz radio luminosity (L radio ≈ 10 37 erg s -1 ) is brighter than ordinary core-collapse SNe but fainter than LLGRB-SNe such as SN 1998bw (associated with LLGRB 980425). We model our VLA observations (spanning 13–43 d) as synchrotron emission from a mildly relativistic (v ≳ 0.3c) forward shock. Second, with Swift and Chandra we detect X-ray emission (L X ≈ 10 41 erg s -1 ) that is not naturally explained as inverse Compton emission or as part of the same synchrotron spectrum as the radio emission. Third, high-cadence (6×/night -1 ) data from the Zwicky Transient Facility (ZTF) shows a double-peaked optical light curve, the first peak from shock-cooling of extended low-mass material (mass M e < 10 -2 M ⊙ at radius R e > 10 12 cm) and the second peak from the radioactive decay of 56 Ni. SN 2020bvc is the first double-peaked Ic-BL SN discovered without a GRB trigger, so it is noteworthy that it shows X-ray and radio emission similar to LLGRB-SNe. For four of the five other nearby (z . 0.05) Ic-BL SNe with ZTF high-cadence data, we rule out a first peak like that seen in SN 2006aj and SN 2020bvc, i.e. that lasts ≈ 1 d and reaches a peak luminosity M ≈ -18. X-ray and radio follow-up observations of Ic-BL SNe with well-sampled early optical light curves will establish whether double-peaked optical light curves are indeed predictive of LLGRB-like X-ray and radio emission.

79 ASTRONOMY AND ASTROPHYSICS↗

PTT System Performance Evaluation in 3-D Imaging of AM Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of nonsintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This study investigates the capability of PTT in imaging several AM structures fabricated from Inconel 718 (IN718) feedstock. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of IN718 nozzle plate and a particle filter plate. The results demonstrate the capability of PTT in 3- D imaging of complex geometry AM structures. Further, increased resolution imaging is achieved compared to prior results using older FLIR SC4000 IR camera. In addition, preliminary studies were conducted on developing image processing algorithms for automated detection of flaws. Initial demonstrations are shown for segmentation of PTT images of flat bottom hole (FBH) specimens. Imaging of FBH specimens was described in a prior report. Intermediate results demonstrated in this report will be developed further in detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electrons and Their Multiple Kinetic Fates in an Ionic Liquid

Ionic liquids (ILs) for electrochemical, nuclear, and solar energy applications operate under harsh conditions, where electrons and transient radical species can form. This communication discusses why anions such as bis(trifluoromethylsulfonyl)imide (Tf 2 N − ) are reduced at the electron-rich electrode whereas in laser photoionization or pulse radiolysis studies, where electrons are ejected from species in the bulk, we often detect long-lived electrons in cavities that interact with IL cations instead. This work argues that bulk excess electrons generated photolytically or radiolytically follow kinetically favored pathways. As such, cavity electrons may not be the most energetically favorable states, but when they form, and they do form, they are kinetically stable. Reduction reactions of anions or electron localization in cavities and subsequent reactions are all expected outcomes. Here we focus on a pyrrolidinium-based IL of the dicyanamide (N(CN) 2 − ) anion because of its large electrochemical window and very low viscosity, which are ideal for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-optical single-shot complete electric field measurement of extreme ultraviolet free electron laser pulses

Recent advances in ultrafast extreme ultraviolet (EUV) and x-ray light sources provide direct access to fundamental time and length scales for biology, chemistry, and materials physics. However, such light pulses are challenging to measure due to the need for femtosecond time resolution at difficult-to-detect wavelengths. Also, single-shot measurements are needed because severe pulse-to-pulse fluctuations are common. Here we demonstrate single-shot, complete field measurements by applying a novel version of frequency resolved optical gating. An EUV free electron laser beam creates a transient grating containing the pulse’s electric field information, which is read out with a 400 nm probe pulse. By varying the time delay between two copies of the EUV pump, rather than between the pump and the probe, we separate the needed coherent wave mixing from the slow incoherent response. Because this approach uses photoionization, it should be applicable from the vacuum ultraviolet to hard x rays.

36 MATERIALS SCIENCE↗

Liquid Core Detection and Strand Condition Monitoring in a Continuous Caster Using Optical Fiber

Real-time monitoring of the liquid core position during the continuous casting of steel has been demonstrated using low-cost distributed optical-fiber-based strain sensors. These sensors were installed on the containment roll support structures in the segments of a production continuous caster to detect the position of the solid–liquid interface and monitor the strand condition during the continuous casting. Distributed Fiber Bragg Grating sensors (FBGs) were used in this work to monitor strain at six roll positions in the caster. The sensor performance was first validated by comparing optical strain measurements with conventional strain gauge measurements in the lab. Next, optical strain measurements were performed on an isolated caster segment in a segment maintenance facility using hydraulic jacks to simulate the presence of a liquid core under the roll. Finally, the sensors were evaluated during caster operation. The sensors successfully detected the load increase associated with the presence of a liquid core under each instrumented roll location. Incidents of bulging and roll eccentricity were also detected using frequency analysis of the optical strain signal. The liquid core position measurements were compared using predictions from computer models (digital twins) in use at the production site. The measurements were in good agreement with the model predictions, with a few exceptions. Under certain transient caster operating conditions, such as spraying practice changes and SEN exchanges, the model predictions deviated slightly from the liquid core position determined from strain measurements.

47 OTHER INSTRUMENTATION↗

Interferometer Detects Acoustic Emissions in Composites

Embedded single-mode optical fibers sample internal-stress fields directly. Statically loaded composite matrix emits pulsed ultrasonic waves which mechanically modulate embedded fiber and phase-modulate transmitted optical field. Modulation detected by optical interferometry and Fourier optical processing converted to electronic signal proportional to acoustic field amplitude integated along length of fiber embedded in specimen. Technique used for measurements of both high- and low-frequency CW acoustic fields as well as high-frequency transients.

Cantrell, J. H.↗

Deformation and damage of composite plates under impact loading

Transient deformation and damage were studied in impacted graphite/epoxy plates. The plates were 8-ply and 16-ply quasi-isotropic laminates clamped around a 12.7 cm diameter circumference. They were instrumented with surface and embedded strain gages and loaded by a 202 gr mass dropped from a height of 1.8 m. The load history and imparted energy were obtained by means of an accelerometer attached to the impactor. Transient strains at various locations through the thickness and at various distances from the loading point were obtained. The characteristic features of the strain records are associated with specific failure modes in the laminate. The deformation history was also correlated with the induced damage as detected by X-radiography and ultrasonics. Impact damage is more extensive in the thicker laminate. Damage takes the form of delaminated strips parallel to the fiber direction in each ply and increasing in length from top to bottom.

Daniel, I. M.↗

Comment on the paper 'On the influx of small comets into the earth's upper atmosphere'

The possibility that comets containing up to 100 tons of ice encounter the earth's atmosphere at a rate of one every 20 min is discussed. Cometary 'hail storms' were proposed to explain observed regular transient decreases in the atmospheric UV dayglow intensity. The decreases take the form of dark 'holes' up to 50 km across. The probability that clouds of objects assumed to be as dark as the nucleus of Comet Halley between the earth and moon would be detectable by ground-based electrooptical deep space telescopes is considered. Conflicting projections of the number of objects which would be detected per hour are examined. High correlations are noted between cometary passages (Comets Encke, Tuttle, Tempel) and intervals of meteor showers (Taurids, Leonids, Geminis, etc.). The holes, however, are not correlated or coincident with the showers. It is suggested that dedicated searches for the unclassified dark objects be carried out in November, when cometary fluxes are high.

Soter, Steven↗

A ROSAT observation of the transient X-ray pulsar GRO J1008-57

We report results of a brief Target of Oppurtunity observation of the newly discovered transient X-ray pulsar Gamma Ray Observatory (GRO) J1008-57 using the ROSAT Position Sensitive Proportional Counter (PSPC). The observation was performed well into the decline of the source outburst as monitored by the BATSE hard X-ray light curve. The PSPC cleanly detected the source, at a 0.1-2.4 keV flux of 2.3 x 10(exp -11) erg/sq cm/s. A position centroid accurate to 10 arc seconds has been determined. The 0.1-2.4 keV spectrum is best characterized by a flat power law with substantial interstellar absorption. The PSPC photon index and column density are consistent with that measured at higher energy by ASCA; there is no evidence for an additional soft component. Light-curve folding reveals a period of 93.4 s, consistent with that measured at higher energies; the 0.1-2.4 keV folded light curve shows a high pulsed fraction and a strongly double-peaked pulse profile. The spectral and temporal properties of GRO J1008-57 as observed using the PSPC are entirely consistent with a pulsar orbiting a massive (OB) companion.

Petre, R.↗

Hard X-Ray Lightcurves of High Mass X-Ray Binaries

Using the 7.2 years of continuous data now available from the Burst And Transient Source Experiment (BATSE) aboard CGRO, we have measured orbital periods and produced folded lightcurves for 8 High Mass X-ray Binaries (HMXB). Given the length of the datasets, our determinations are based on many more binary orbits than previous investigations. Thus our source detections have high statistical significance and we are able to follow long-term trends in X-ray output. In particular we focus on two systems: A0538-668 and EXO2030+375 both HMXBs exhibiting Type I outbursts. Recent work on A0538-668 (Alcock et al 1999) reported a 16.65d optical variability due to the orbital period, but only seen during minima of a longer-term variability at 421d. We searched for this signal in the BATSE dataset using an ephemeris derived from Alcock et al ( 1999) & Skinner ( 1982). We found no evidence for such modulation and place an upper limit of 3.0 x 10(exp -3) photon/sq cm.s in the 20-70 keV BATSE energy band , based upon statistical modelling of the signal. EXO2030+375 has exhibited an X-ray active epoch, followed by a quiescent period lasting 2.5yr and since April 1996 has exhibited renewed activity. Previous observations (Reig et a 1998) using RXTE ASM data indicate secondary outbursts occur at apastron passage during the current epoch, but not in the former. We present a lightcurve for the earlier epoch showing convincing evidence for such apastron outbursts. We find apastron outbursts in 3 sources, all having orbital periods greater than 41d. No such signal is conclusively detected in the more rapidly orbiting systems studied.

Laycock, S.↗

All-Sky Search for Short Gravitational-Wave Bursts in the Third Advanced LIGO and Advanced Virgo Run

This paper presents the results of a search for generic short-duration gravitational-wave transients in datafrom the third observing run of Advanced LIGO and Advanced Virgo. Transients with durations ofmilliseconds to a few seconds in the 24–4096 Hz frequency band are targeted by the search, with noassumptions made regarding the incoming signal direction, polarization, or morphology. Gravitationalwaves from compact binary coalescences that have been identified by other targeted analyses are detected,but no statistically significant evidence for other gravitational wave bursts is found. Sensitivities to a varietyof signals are presented. These include updated upper limits on the source rate density as a function of thecharacteristic frequency of the signal, which are roughly an order of magnitude better than previous upperlimits. This search is sensitive to sources radiating as little as∼10−10M⊙c2in gravitational waves at∼70Hz from a distance of 10 kpc, with 50% detection efficiency at a false alarm rate of one per century.The sensitivity of this search to two plausible astrophysical sources is estimated: neutron starfmodes,which may be excited by pulsar glitches, as well as selected core-collapse supernova models.

R Abbott↗

Proton radiation effects on electronic defect states in MOCVD-grown (010) β -Ga 2 O 3

The impact of 1.8 MeV proton irradiation on metalorganic chemical vapor deposition grown (010) β-Ga 2 O 3 Schottky diodes is presented. It is found that after a 10.8 × 10 13 cm –2 proton fluence the Schottky barrier height of (1.40 ± 0.05 eV) and the ideality factor of (1.05 ± 0.05 ) are unaffected. Capacitance–voltage extracted net ionized doping curves indicate a carrier removal rate of 268 ± 10 cm –1 . The defect states responsible for the observed carrier removal are studied through a combination of deep level transient and optical spectroscopies (DLTS/DLOS) as well as lighted capacitance–voltage (LCV) measurements. The dominating effect on the defect spectrum is due to the E c -2.0 eV defect state observed in DLOS and LCV. This state accounts for ~75 % of the total trap introduction rate and is the primary source of carrier removal from proton irradiation. Of the DLTS detected states, the E c -0.72 eV state dominated but had a comparably smaller contribution to the trap introduction. These two traps have previously been correlated with acceptor-like gallium vacancy-related defects. Several other trap states at E C -0.36, E C -0.63, and E C -1.09 eV were newly detected after proton irradiation, and two pre-existing states at E C -1.2 and E C -4.4 eV showed a slight increase in concentration after irradiation, together accounting for the remainder of trap introduction. However, a pre-existing trap at E c -0.40 eV was found to be insensitive to proton irradiation and, therefore, is likely of extrinsic origin. Furthermore, the comprehensive defect characterization of 1.8 MeV proton irradiation damage can aid the modeling and design for a range of radiation tolerant devices.

42 ENGINEERING↗

A Search for Short-Period Accreting Pulsars with BATSE

Accreting X-ray pulsar systems can be detected and monitored by the BATSE Pulsar Monitor at full sensitivity only above the Nyquist period of 2.048 s, since it uses the DISCLA data type. Systems with shorter periods than 2 s can be observed, but with a reduced sensitivity, since only the aliased power is measured. While persistent sources in the period range below that have been found by earlier spacecraft, transient systems may still be undiscovered, due to limited time coverage of the galactic plane with all-sky instruments. BATSE data with a time resolution of 31 ms (PSR single-sweep mode) has been collected for four energy channels spanning 20-50 keV , at scheduled times for particular detectors and detector combinations which view the galactic plane. The data spans Nov 1993 to present, with a typical exposure of 15000 s per day to approximately 1/8 of the plane. An accelerated FFT-based search is in progress on these data. Data are segmented into approximately 300 second intervals, barycentered for 3 possible source directions spaced by 30 degrees about the detector normal, with the time series accelerated for each of 15 steps, each spaced by 5 x 10(exp -5). To avoid loss of coherence due to system orbital velocities, FFTs are averaged over each 1/4 day interval separately. Results of this search are presented, including examples of detection of Her X-1, Cen X-3, and other pulsars.

Wilson, R. B.↗

Dynamic Model Agnostic Reliability Evaluation of Machine-Learning Models Integrated in Instrumentation & Control Systems

In recent years, the field of data-driven neural network-based machine learning (ML) algorithms has grown significantly and spurred research in its applicability to instrumentation and control systems. While they are promising in operational contexts, the trustworthiness of such algorithms is not adequately assessed. Failures of ML-integrated systems are poorly understood; the lack of comprehensive risk modeling can degrade the trustworthiness of these systems. In recent reports by the National Institute for Standards and Technology, trustworthiness in ML is a critical barrier to adoption and will play a vital role in intelligent systems' safe and accountable operation. Thus, in this work, we demonstrate a real-time model-agnostic method to evaluate the relative reliability of ML predictions by incorporating out-of-distribution detection on the training dataset. It is well documented that ML algorithms excel at interpolation (or near-interpolation) tasks but significantly degrade at extrapolation. This occurs when new samples are "far" from training samples. The method, referred to as the Laplacian distributed decay for reliability (LADDR), determines the difference between the operational and training datasets, which is used to calculate a prediction's relative reliability. LADDR is demonstrated on a feedforward neural network-based model used to predict safety significant factors during different loss-of-flow transients. LADDR is intended as a "data supervisor" and determines the appropriateness of well-trained ML models in the context of operational conditions. Ultimately, LADDR illustrates how training data can be used as evidence to support the trustworthiness of ML predictions when utilized for conventional interpolation tasks.

97 MATHEMATICS AND COMPUTING↗

Sub-Diurnal Methane Variations on Mars Driven by Barometric Pumping and Planetary Boundary Layer Evolution

In recent years, the Tunable Laser Spectrometer within the Sample Analysis at Mars (TLS-SAM) instrument on board the Mars Science Laboratory (MSL) Curiosity rover has detected methane variations in the atmosphere at Gale crater. Methane concentrations appear to fluctuate seasonally as well as sub-diurnally, which is difficult to reconcile with an as-yet-unknown transport mechanism delivering the gas from underground to the atmosphere. To potentially explain the fluctuations, we consider barometrically induced transport of methane from an underground source to the surface, modulated by temperature-dependent adsorption. The subsurface fractured-rock seepage model is coupled to a simplified 1-D atmospheric mixing model to provide insights on the pattern of atmospheric methane concentrations in response to transient surface methane emissions, as well as to predict sub-diurnal variation in methane abundance for the northern summer period, which is a candidate time frame for a MSL Curiosity sampling campaign. Our analysis suggests that there is a lower limit to the subsurface fracture density that can produce the observed methane patterns, below which the atmospheric methane variations would be out of phase with the observations. The best-performing model scenarios indicate a significant, short-lived methane pulse just prior to sunrise, the detection of which by TLS-SAM would be a potential indicator of the contribution of barometric pumping to Mars' atmospheric methane variations.

54 ENVIRONMENTAL SCIENCES↗

Deep level defects in low-pressure chemical vapor deposition grown (010) β-Ga 2 O 3

This study provides the full-bandgap evaluation of defect state distributions in beta phase gallium oxide (β-Ga 2 O 3 ) grown by low-pressure chemical vapor deposition (LPCVD) on (010) β-Ga 2 O 3 substrates at high growth of up to 20 µm/h. Deep-level optical spectroscopy and deep-level transient spectroscopy measurements applied to Ni/β-Ga 2 O 3 Schottky diodes revealed the presence of a previously unreported defect state at E C -3.6 eV, which dominated the overall trap distribution in LPCVD grown material. However, states at E C -0.8 eV, E C -2.0 eV, and E C -4.4. eV were also detected, similar to prior studies on β-Ga 2 O 3 grown by other methods, with similar or lower concentrations for the LPCVD samples. The E C -0.8 eV and E C -2.0 eV states were previously connected to residual Fe impurities and gallium vacancies, respectively. The total concentration of traps in the LPCVD material was on par with or lower than the state-of-the-art metal–organic chemical vapor deposition-grown materials despite the much higher growth rate, and the distribution of states showed negligible dependence on SiCl 4 flow rate and doping concentration. These results demonstrate that the high growth rate of LPCVD-grown β-Ga 2 O 3 is very promising for achieving thick, low defect density, and high-quality layers needed for multi-kV device applications.

36 MATERIALS SCIENCE↗

FORTE Measurements of Global Lightning Altitudes

While multiple lightning detection systems provide geographical locations of lightning events across the globe, robust lightning altitude measurements on a global scale have proven elusive. Space-based platforms have an advantageous viewing geometry for making these measurements, but prior studies with the Fast On-orbit Recording of Transient Events (FORTE) satellite were limited to a few thousand events. In this study, we apply the same technique for calculating source altitude from the previous efforts to a large catalog of hundreds of thousands of global FORTE in-cloud lightning events that were coincident with flashes geolocated by its lightning imager between 1997 and 2003. We use this new data set to document global variations in lightning altitude. As in previous studies, we find that FORTE primarily resolves sources from the upper (positive) charge layer at ~11 km altitude in normal thunderstorms. However, sources are also recorded from other charge layers in the storm and from leaders developing between layers. In particular, we note a pronounced increase in source altitude in the first 20 ms of FORTE flashes from the negative leader developing upward into the upper positive charge layer. Regions known for wintertime and/or stratiform lightning have increased contributions from low-altitude sources, while tropical regions particularly around Panama and the Maritime Continent have the greatest concentrations of high-altitude sources.

54 ENVIRONMENTAL SCIENCES↗

Detection of Thermal Emission at Millimeter Wavelengths from Low-Earth Orbit Satellites

The detection of satellite thermal emission at millimeter wavelengths is presented using data from the 3rd-Generation receiver on the South Pole Telescope (SPT-3G). This represents the first reported detection of thermal emission from artificial satellites at millimeter wavelengths. Satellite thermal emission is shown to be detectable at high signal-to-noise on timescales as short as a few tens of milliseconds. An algorithm for downloading orbital information and tracking known satellites given observer constraints and time-ordered observatory pointing is described. Consequences for cosmological surveys and short-duration transient searches are discussed, revealing that the integrated thermal emission from all large satellites does not contribute significantly to the SPT-3G survey intensity map. Measured satellite positions are found to be discrepant from their two-line element (TLE) derived ephemerides up to several arcminutes which may present a difficulty in cross-checking or masking satellites from short-duration transient searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗