Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

Partial defect verification of spent fuel assemblies by PDET: Principle and field testing in Interim Spent fuel Storage Facility (CLAB) in Sweden

Here, the need for the development of a credible method and instrument for partial defect verification of spent fuel has been emphasized over a few decades in the safeguards communities as the diverted spent fuel pins can be the source of nuclear terrorism or devices. The need is increasingly more important and even urgent as many countries have started to transfer spent fuel to so called "difficult-to-access" areas such as dry storage casks, reprocessing or geological repositories. Partial defect verification is required by IAEA before spent fuel is placed into "difficult-to-access" areas. Earlier, Lawrence Livermore National Laboratory (LLNL) has reported the successful development of a new, credible partial defect verification method for pressurized water reactor (PWR) spent fuel assemblies without use of operator data, and further reported the validation experiments using commercial spent fuel assemblies with some missing fuel pins. The method was found to be robust as the method is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up. Since then, the PDET system has been designed and prototyped for 17×17 PWR spent fuel assemblies, complete with data acquisition software and acquisition electronics. In this paper, a summary description of the PDET development followed by results of the first successful field testing using the integrated PDET system and actual spent fuel assemblies performed in a commercial spent fuel storage site, known as Central Interim Spent fuel Storage Facility (CLAB) in Sweden will be presented. In addition to partial defect detection initial studies have determined that the tool can be used to verify the operator declared average burnup of the assembly as well as intra-assembly bunrup levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SPEL: Software tool for Porting E3SM Land Model with OpenACC in a Function Unit Test Framework

Most high-end computers adopt hybrid architecture, porting a large-scale scientific code onto accelerators is necessary. The paper presents a generic method for porting large-scale scientific code onto accelerators using compiler directives within a modularized function unit test platform. We have implemented the method and designed a software tool (SPEL) to port the E3SM Land Model (ELM) onto the GPUs in the Summit computer. SPEL automatically generates GPU-ready test modules for all ELM functions, such as CanopyFlux, SoilTemperature, and EcosystemDynamics. SPEL breaks the ELM into a collection of standalone unit test programs for easy code verification and further performance improvement. We further optimize several ELM test modules with advanced techniques, including memory reduction, reconstructed parallel loops, and asynchronous GPU kernel launch. We hope our study will inspire new toolkit developments that expedite large-scale scientific code porting with compiler directives.

Schwartz, Peter↗

Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plans

Purpose: Cone beam CT is increasingly being used for daily patient positioning verification during radiation therapy treatments. The daily use of CBCT could lead to accumulated patient doses higher than the older technique of weekly portal imaging. There have been several studies focusing on measurement or calculation of the patient dose from CBCT recently. Methods: This study investigates the feasibility of configuring a kV x-ray source in a commercial treatment planning system to calculate the dose to patient resulting from an IGRT procedure. The method proposed in this article can be used to calculate dose from CBCT imaging procedure and include that in the patient treatment plans. Results: The kilovoltage beam generated by the CBCT imager has been modeled using the planning system. The modeled profiles agree with the measured ones to within 5%. The modeled beam was used to calculate dose to phantom in the pelvic region and the calculations were compared to TLD measurements. The agreement between calculated and measured doses ranges from 0% to 19% in soft tissue with larger variations observed near and within the bone. Conclusions: The modeling of the beam produces reasonable results and the dose calculation comparisons indicate the potential for computing kilovoltage CBCT doses using a treatment planning system. Further improvements in the dose calculation algorithm are necessary, especially for dose calculations in and near the bone.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Mississippi CCS Project

The Mississippi CCS Project is a proposed large-scale industrial carbon capture and sequestration (CCS) project which would have demonstrated advanced technologies to capture and sequester carbon dioxide (CO 2 ) emissions from industrial sources into underground formations. Specifically, the Mississippi CCS Project was to accelerate commercialization of large-scale CO 2 storage from industrial sources by leveraging synergy between a proposed petcoke to Substitute Natural Gas (SNG) plant that is selected for a Federal Loan Guarantee and would be the largest integrated anthropogenic CO 2 capture, transport, and monitored sequestration program in the U.S. Gulf Coast Region. The Mississippi CCS Project was to promote the expansion of enhanced oil recovery (EOR) in the Mississippi, Alabama and Louisiana region which would supply greater energy security through increased domestic energy production. The capture, compression, pipeline, injection, and monitoring infrastructure would have continued to sequester CO 2 for many years after the completion of the term of the DOE agreement. The objectives of this project were expected to be fulfilled through two distinct phases. The overall objective of Phase 1 was to develop a fully definitive project basis for a competitive Renewal Application process to proceed into Phase 2 - Design, Construction and Operations. Phase 1 included the studies that establish the engineering design basis for the capture, compression and transportation of CO 2 from the MG SNG Project, and the criteria and specifications for a monitoring, verification and accounting (MVA) plan at the Soso oil field in Mississippi. The overall objective of Phase 2, was to execute design, construction and operations of three capital projects: the CO 2 capture and compression equipment, the Mississippi CO 2 Pipeline to Denbury's Free State Pipeline, and an MVA system at the Soso oil field.

02 PETROLEUM↗

Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Impact of Increased Requirements for Verification Measurements of Category III and IV Receipts

As part of the regular nuclear material accounting and control process, sites that have accountable nuclear material regularly perform measurements of the material in their possession. The expectation for the type of measurements and their frequency is set out in Department of Energy (DOE) Order 474.2, and further detailed in each site’s respective material control and accountability (MC&A) plan and associated controlling documents. The measurements of interest in this report are those performed on external (between DOE sites) transfer receipts of Category III or IV accountable materials. In 2020, a revision of DOE Order 474.2 was proposed that would significantly increase the requirement that measurements be performed upon receipt of material, and further, that those measurements be quantitative verification (rather than qualitative confirmatory) measurements. A survey was performed of DOE sites to discuss the impact on their MC&A measurements program if more rigorous verification measurements requirements for Category III and IV receipts were implemented. An assessment of nondestructive assay (NDA) measurement instruments to meet those needs was also performed. Across the board, sites indicated that personnel and budget would cause the largest impact. Sites which are qualified as Category I/II indicated a reduced impact as these sites already have the measurement capabilities and some personnel but would require the acquisition of additional measurement systems. Category III/IV sites indicated a much larger impact as these sites generally have smaller MC&A programs. A few smaller sites stated a measurement program would need to be created to handle the demand. Calorimetry, quantitative gamma spectroscopy and neutron coincidence counting systems were identified as common systems that could meet the verification measurement requirements. The other, and perhaps larger issue is the need for calibration standards for the calorimetry and neutron coincidence counting systems. It is proposed that a comparative study be performed for ISOCS and ISOTOPICS, qualification of a COTS calorimetry system be performed, and development of an AWCC system that uses a neutron generator.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

TH-C-17A-01: Imaging Sensor Comparison for Real-Time Cherenkov Signal Detection From Tissue for Treatment Verification

Purpose: To identify the optimum imaging sensor for a clinical system that would provide real-time imaging of the surface beam profile on patients as novel visual information to radiation therapy technologists, and more rapidly collect clinical data for large-scale studies of Cherenkov applications in radiotherapy. Methods: Four camera types, CMOS, CCD, ICCD and EMICCD, were tested to determine proficiency in the detection of Cherenkov signal in the clinical radiotherapy setting, and subsequent maximum supportable frame rate. Where possible, time-gating between the trigger signal from the LINAC and the intensifiers was implemented to detect signal with room lighting conditions comparable to patient treatment scenarios. A solid water phantom was imaged by the EM-ICCD and ICCD to evaluate the minimum number of accumulations-on-chip required for adequate Cherenkov detection, defined as >200% electron counts per pixel over background signal. Additionally, an ICCD and EM-ICCD were used clinically to image patients undergoing whole-breast radiation therapy, to understand the impact of the resolution limitation of the EM-ICCD. Results: The intensifier-coupled cameras performed best at imaging Cherenkov signal, even with room lights on, which is essential for patient comfort. The tested EM-ICCD was able to support single-shot imaging and frame rates of 30 fps, however, the current maximum resolution of 512 × 512 pixels was restricting. The ICCD used in current clinical trials was limited to 4.7 fps at a 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths (30% QE vs current 7%) promises 16 fps at the same resolution at lower cost than the EM-ICCD. Conclusion: The ICCD with the better red wavelength QE intensifier was determined to be the best suited commercial-off-the-shelf camera to detect real-time Cherenkov signal and provide the best potential for real-time display of radiation dose on the skin during treatment. Funding is from grants from the NIH numbers R01CA109558 and R21EB017559.

60 APPLIED LIFE SCIENCES↗

REPORT OF THE ISS OSI INVITED MEETING, VIENNA, 24-27 MARCH, 2009

The International Scientific Studies project (ISS) was initiated in early 2008 with the objective of creating a series of activities aimed at application of modern scientific methods to improve the efficiency of analysis and the quality of verification of the Comprehensive Nuclear Test-Ban Treaty Organization (CTBTO). The ISS On-Site Inspection (OSI) Invited Meeting convened on March 24, 2009 with the objectives of gaining a better understanding of the phenomenology of underground nuclear explosions (UNE) for OSI purposes and to identify areas of interest to OSI that could benefit significantly from contributions by the general scientific community. Fifteen invited experts from four countries, along with fifteen members of the OSI Division of the Provisional Technical Secretariat (PTS) met for four days at the Vienna International Center in an informal setting to discuss the application of observational methods, geophysical techniques, radionuclide measurement methods, environmental sampling methods, drilling techniques, and information management in the context UNE phenomena and OSI implementation. The meeting began with the identification and description of two general OSI scenarios, a vertical borehole emplacement and a horizontal tunnel emplacement, that serve as general examples of past UNE testing activities that can be used as a reference to identify UNE phenomena relevant for OSI observations. A significant portion of the first day of the meeting was spent in the description of the details of these scenarios and their implications for OSI observables. This discussion then served as a foundation for the discussions of the following three days in which OSI methods and technologies were evaluated in the context of UNE phenomenology and signatures. The methods and technologies discussed included visual observation from air and ground, radiation detection from the air, ground, and subsurface, ground-based and airborne geophysical observations and analysis, collection strategies for air, water, and solid samples, drilling concepts, and aspects of data fusion, information management, and modeling and simulation. The informal setting of the meeting provided a 'brainstorming' atmosphere and participation was excellent. One important aspect of this particular group was the very wide breadth of experience and expertise represented, ranging from those sharing their knowledge of UNE testing practice, radiological measurements and sampling, and knowledge of the underground effects of UNEs, to those with extensive experience in scientific and commercial geophysical measurements and surveys, to others with rich experience gained from several OSI field exercises, including the recent OSI Integrated Field Exercise in held in Kazakhstan in September 2008. During the workshop a number of topic areas relevant to OSI, explained in the list below, were identified that will benefit from collaboration with the international scientific community. Most of the topics represent the potential for studies of long-term interest, but some topics were identified that could be addressed, either by workshop participants or others known to the participants, that could be included as abstracts for submission to the ISS meeting taking place in June 2009. Items with topics that could be covered in the June meeting are annotated in the list. The meeting ended with the general understanding that ISS will not be completed with the June 2009 Conference. Rather, the ISS is considered as a long term project sponsoring relevant ongoing international scientific initiatives to expand and improve the verification capabilities of the Comprehensive Nuclear Test-Ban Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Thermal properties of simulated Hanford waste glasses

Abstract The Hanford Tank Waste Treatment and Immobilization Plant will vitrify the mixed hazardous wastes generated from 45 years of plutonium production at the Hanford Site in Washington State. The molten glasses will be poured into stainless steel containers or canisters and subsequently cooled for storage and disposal. For appropriate facility design and operations to handle such highly energy‐consuming processes, knowledge of the material properties is required. The thermal properties (heat capacity, thermal diffusivity, and thermal conductivity) of representative high‐level and low‐activity waste glasses were studied as functions of temperature in the range of 200°C‐800°C (relevant to the cooling process). Simultaneous differential scanning calorimetry‐thermal gravimetry (DSC‐TGA), Xe‐flash diffusivity, pycnometry, and dilatometry were implemented. The study showed that simultaneous DSC‐TGA would be a reliable method for obtaining the heat capacity of various glasses in the temperature range of interest. Accurate thermal properties from this study were shown to provide a more realistic guideline for capacity and time constraints of the heat removal process when compared to the original conservative design‐basis engineering estimates. The estimates, though useful for design in the absence of measured physical properties, can now be supplanted and the measured thermal properties can be used in design verification activities.

Rodriguez, Carmen P.↗

IEEE STD. 1012 and NEI 96-07, Appendix D - Strange bedfellows? - 149

The final draft of a revision to IEEE Std. 1012-2012, 'IEEE Standard for System, Software and Hardware Verification and Validation', is expected to be approved for publication in June 2017. A draft of NEI 96-07, Appendix D, 'Supplemental Guidance for Application of 10 CFR 50.59 to Digital Modifications', has been submitted to the NRC staff for review and endorsement. What, if any, relationship exists between these two documents? How can the nuclear industry utilize the first one to help ensure success when applying the second one? NRC Regulatory Guides only endorse digital system and software related industry standards for application to safety-related systems and components, but the vast majority of digital modifications are made to non-safety related systems and components, so are these industry standards of little or no use when performing digital upgrades to non-safety related equipment? This paper answers these and other related questions and shows how application of a graded approach to verification and validation, utilizing the IEEE Std. 1012 concept of 'integrity level', can increase the likelihood of a 10 CFR 50.59 evaluation outcome that does not require prior NRC review and approval for non-safety related digital modifications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Next Step in Deployment of Computer Based Procedures For Field Workers: Insights And Results From Field Evaluations at Nuclear Power Plants

The paper-based procedures currently used for nearly all activities in the commercial nuclear power industry have a long history of ensuring safe operation of the plants. However, there is potential to greatly increase efficiency and safety by improving how the human operator interacts with the procedures. One way to achieve these improvements is through the use of computer-based procedures (CBPs). A CBP system offers a vast variety of improvements, such as context driven job aids, integrated human performance tools (e.g., placekeeping, correct component verification, etc.), and dynamic step presentation. The latter means that the CBP system could only display relevant steps based on operating mode, plant status, and the task at hand. A dynamic presentation of the procedure (also known as context-sensitive procedures) will guide the operator down the path of relevant steps based on the current conditions. This feature will reduce the operator’s workload and inherently reduce the risk of incorrectly marking a step as not applicable and the risk of incorrectly performing a step that should be marked as not applicable. The research team at the Idaho National Laboratory has developed a prototype CBP system for field workers, which has been evaluated from a human factors and usability perspective in four laboratory studies. Based on the results from each study revisions were made to the CBP system. However, a crucial step to get the end users' (e.g., auxiliary operators, maintenance technicians, etc.) acceptance is to put the system in their hands and let them use it as a part of their everyday work activities. In the spring 2014 the first field evaluation of the INL CBP system was conducted at a nuclear power plant. Auxiliary operators conduct a functional test of one out of three backup air compressors each week. During the field evaluation activity, one auxiliary operator conducted the test with the paper-based procedure while a second auxiliary operator followed along with the computer-based procedure. After each conducted functional test the operators were asked a series of questions designed to provide feedback on the feasibility to use a CBP system in the plant and the general user experience of the CBP system. This paper will describe the field evaluation and its results in detail. For example, the result shows that the context driven job aids and the incorporated human performance tools are much liked by the auxiliary operators. The paper will describe and present initial findings from a second field evaluation conducted at second nuclear utility. For this field evaluation a preventive maintenance work order for the HVAC system was used. In addition, there will be a description of the method and objective of two field evaluations planned to be conducted late 2014 or early 2015.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

60 APPLIED LIFE SCIENCES↗

Independent Verification Survey of the High Flux Beam Reactor, Building 802 Fan House Brookhaven National Laboratory Upton, New York (Final Report)

The Separations Process Research Unit (SPRU) complex located on the Knolls Atomic Power Laboratory (KAPL) site in Niskayuna, New York, was constructed in the late 1940s to research the chemical separation of plutonium and uranium (Figure A-1). SPRU operated as a laboratory scale research facility between February 1950 and October 1953. The research activities ceased following the successful development of the reduction oxidation and plutonium/uranium extraction processes. The oxidation and extraction processes were subsequently developed for large scale use by the Hanford and Savannah River sites (aRc 2008a). Decommissioning of the SPRU facilities began in October 1953 and continued through the 1990s.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ZND Verification Tests for Reactive Burn Models in FLAG

The ZND theory, named after Zeldovich, von Neumann, and Doering, provides a simple model for one-dimensional ideal steady-state detonation. It assumes that the detonation wave front starts with a shock that is a discontinuous jump and is followed by a finite-length reaction zone. Reactive burn (also called reactive flow) models are based on ZND theory, as they model the shock initiation and detonation process with a finite reaction rate. The ZND wave propagation test is essentially the only available test case where an analytic solution exists for verification of reactive burn models in numerical codes. However, there are extensions and variants of the ZND test that have been devised for verification of multidimensional flows. The objective of this work is to provide verification of the reactive burn models currently implemented in the Lagrangian hydrocode FLAG and investigate the influence of mesh resolution, artificial viscosity models, and the Arbitrary Lagrangian-Eulerian (ALE) Euler relaxer on the simulation results. The burn models of interest are the Wescott-Stewart-Davis (WSD) model, the Scaled Uniform Reactive Flow (SURF) model (specifically with the SURFplus model extension), and the Arrhenius shock temperature state dependent WSD (AWSD) model. Previously, Ralph Menikoff has used ZND tests for verification of the SURF and SURFplus models in the Eulerian hydrocode xRAGE. The ZND tests here are somewhat different than the approach by Menikoff. In particular, we use a piston-driven ZND detonation wave (via a prescribed constant velocity boundary condition) in a Lagrangian framework whereas Menikoff had a ZND wave followed by a invariant rarefaction wave. The xRAGE simulations were carried out on uniform grids and adaptive mesh refinement (AMR) grids. Although AMR was recently implemented in FLAG and now fully functional for 2D simulations, it will not be evaluated with ZND tests at this time. Some work has been done previously for validating the reactive burn models in FLAG. For example, the validation studies of SURF with shock-to-detonation (SDT) tests, cylinder tests, and gap-stick tests. Further validation of the AWSD, WSD, and SURF models is described in for SDT, multi-shock, cylinder, and corner-turning tests. Recently, a large parameter study with approximately twenty SDT tests was performed to validate the AWSD, WSD, SURF, and SURFplus models while also investigating mesh resolution and artificial viscosity settings. To the best of our knowledge, the current work represents the first documented verification of these burn models in FLAG. The reader should note that many of the tables and figures in this report use units of cm/g/µs, which are the default units for FLAG. However, some lengths and velocities are expressed in µm and mm/µs, respectively, which are typical units for detonation analyses.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗