Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Observation of Hypervelocity Dust in Dense Supersonic Plasma Flows: Physics and Applications

Synthetic diamond and graphite dust powders with a wide range of sizes, from a few to several tens of microns in diameter were accelerated to velocities up to 4 km/s in vacuum by plasma jet produced in a coaxial gun. Some of the key features of the plasma flow are high density, of the order of 10{sup 22} m{sup -3}, low ion and electron temperatures, of only a few eV, and good collimation over a distance of {approx_equal}2 m due to confinement by the self-generated magnetic field. The main features of this plasma-drag acceleration technique are presented and discussed. From basic science point of view hypervelocity dust is useful for studying the physics of dust interaction with energetic plasma flows at microscopic level. In physical applications, it has been proposed to use hypervelocity dust for diagnostic or control of magnetically confined fusion plasmas. In engineering, hypervelocity dusty plasmas are extensively employed in industrial processes involved in the processing of surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Ionization Profile Monitors in the Recycler Ring

The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their measurements. Accurately measuring beam size through the IPMs was crucial to recognize the loss mechanisms for accelerators and to keep the beam loss to a minimum. Thus, performing measurements with different parameters using the IPMs led to a better analysis on how changes in conditions affect the beam size. The IPM measurements are compared with that of multi-wires in the upstream transfer line after applying corrections. The results were compared with other diagnostics and the change in the beam size for different parameters are presented in this paper.

43 PARTICLE ACCELERATORS↗

LaserNetUS Collaboration Network—University of Rochester (Final Report)

LaserNetUS Collaborative Network established in 2018 is a network of high-power laser facilities supported by the Department of Energy (DOE) Office of Fusion Energy Sciences (FES) and operating effectively as a user facility. Its mission is to advance and promote intense laser science and applications by providing scientists and students with broad access to unique facilities and enabling technologies, advancing the frontiers of laser-science research, and fostering collaboration among researchers and networks from around the world. Users who submit proposals through an annual call are selected by an external and independent proposal review panel (PRP) not involving personnel from any of the facilities. Besides the Omega Laser Facility at the University of Rochester’s Laboratory for Laser Energetics (UR/LLE), the network during this project period includes high-intensity laser facilities from six other universities and three national laboratories, namely, the Colorado State University (CSU), the University of Michigan (UM), the University of Nebraska at Lincoln (UNL), The Ohio State University (OSU), Université du Québec, the University of Texas at Austin (UT Austin), Lawrence Berkeley National Laboratory (LBNL), SLAC National Accelerator Laboratory (SLAC) and Lawrence Livermore National Laboratory (LLNL), respectively. The network facilities span a wide range in laser pulse energy, pulse duration, repetition rate, and experimental diagnostic equipment enabling innovative research in a variety of exciting areas. Details of the LaserNetUS facilities, organization and committees, events, and accomplishments can be found at the network website (https://lasernetus.org/). A very important role that the LaserNetUS fulfills is the training of students and young scientists who will be key for the future development of laser-plasma science and high-power laser technology itself. The network provides these students not only with access to the most advanced instrumentation and laser facilities, but also the opportunities to interact and collaborate with students from other institutions and with a large group of experienced scientists. As the largest university-based laser users’ facility in the world, the Omega Laser Facility at the UR/LLE has served the high-energy-density physics (HEDP) and inertial fusion science community for nearly 40 years. The multi-beam multi-kJ OMEGA EP Laser System brings unique capabilities to the LaserNetUS network. The combination of high intensity and high energy in short- and long-pulse operation together with solid or gas-jet targets and externally applied magnetic fields provides users a wide domain of experimental conditions. This award provides a total of eight shot days on OMEGA EP for LaserNetUS users. During the award period of performance (June 2019–November 2021), seven teams have fully utilized the eight shot days for their unique science experiments on OMEGA EP with a total of 83 target shots. These experiments involve 13 graduate students, two undergraduate students and six postdoctoral researchers. Results have been widely disseminated at international conferences including LaserNetUS annual meeting (~20 presentations including three invited), and in peer-reviewed journal publications (three published with several manuscripts in preparation).

36 MATERIALS SCIENCE↗

Measurements of the highest acceleration gradient for ions produced with a long laser pulse

Ultrafast plasma light ion streams have been produced using the 300 ps, kJ-class iodine laser, operating at PALS Centre in Prague. Ion detection was performed through standard ion collectors (IC) in time-of-flight configuration (TOF), shielded by thin metallic absorbers. This new diagnostics technique has been theoretically studied and experimentally tested in order to cut the long photopeak contribution and to analyze the ultrafast particle signal. Processing the obtained experimental IC-TOF data, including deconvolution processes of the TOF signals, UV/soft-x-ray photopeak absorption, and ion transmission calculations for different metallic filters, is shown. Mainly amorphous carbon (graphite) targets have been irradiated in order to limit the maximum number of ion charge states and to focus our study on demonstrating the validity of the proposed investigation technique. Maximum ion energy and acceleration gradient estimations as a function of the laser energy and focal spot diameter are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory tests of laser control of electron beams for future colliders

Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser–beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.

accelerator physics↗

Detectors and beam monitors based on wide bandgap semiconductors at cryogenic temperatures

Wide-bandgap semiconductors, such as single-crystal diamond and sapphire, can be used to measure the flux of passing particles through a particle-induced conductivity effect. We recently demonstrated a diamond-based, electrodeless electron beam halo monitor. This monitor utilized a thin diamond blade placed within an open, high-quality microwave resonator. The blade partially intercepted the beam and changes in the RF properties of the resonator were used to infer beam parameters. To enhance the sensitivity of our semiconductor sensors, we propose two new techniques: (1) biasing the semiconductor sensor to support avalanche multiplication of free carriers, and (2) operating at cryogenic temperatures to reduce intrinsic semiconductor losses and increase the mobility of induced carriers. These techniques are applicable not only to particle beam diagnostics but also to the detection of various types of ionizing radiation.

Accelerator Physics↗

A modular optics design for the LBNE beamline

Protons extracted from the Main Injector (MI) in the MI-60 straight section are transported 84 m through quadrupole Q106 in the NuMI stub, at which point two 6-3-120 vertical switching magnets, followed by three EPB vertical dipoles, steer the beam into the main body of the LBNE beamline. From Q106 in NuMI the LBNE beamline transports these protons 722.0 m to the LBNE target, located 41.77 m (137.0 ft) below the MI beamline center (BLC) elevation, on a trajectory aimed towards DUSEL. Bending is provided (predominantly) by 34 long (6 m) MI-style IDA/IDB and 8 short (4 m) IDC/IDD dipoles [through 48.36{sup o} horizontally and -5.844{sup o} (net) vertically]. Optical properties are defined by 49 quadrupoles (grouped functionally into 44 focusing centers) of the proven MI beamline-style 3Q60/3Q120 series. All focusing centers are equipped with redesigned MI-style IDS orbit correctors and dual-plane beam position monitors (BPM's). Ample space is available in each arc cell to accommodate ion pumps and diagnostic instrumentation. Parameters of the main magnets are listed in a table.

43 PARTICLE ACCELERATORS↗

Dielectronic recombination studies based on EBIT

Dielectronic recombination (DR) process plays an important role in high temperature plasmas, where DR can affect charge balance and level populations significantly, and can cause radiative energy loss. Resolvable DR sourced satellite lines are often used for plasma temperature diagnostics, while the un-resolvable ones disturb determining spectral line shape, line intensity, and line position. Data of DR resonant strength is vital for accurate modeling of high temperature plasmas. DR studies are also important for testing atomic structure and atomic collision theories, since they carry information on quantum electrodynamics, relativistic effects, electron correlations and so on. Electron beam ion trap (EBIT) is an accelerator type device, which is capable of acting as both ion sources and light sources. EBIT can produce a special sort of plasma, in which electron energy is tunable and has a very narrow distribution. This made it possible for disentanglement studies on electron ion collision processes in plasmas. In this paper, experimental studies of DR processes based on electron beam ion traps (EBIT) will be discussed.

43 PARTICLE ACCELERATORS↗

Understanding the Implications of a LINAC’s Microstructure on Devices and Photocurrent Models

Here, the effect of a linear accelerator’s (LINAC’s) microstructure (i.e., train of narrow pulses) on devices and the associated transient photocurrent models are investigated. The data indicate that the photocurrent response of Si-based RF bipolar junction transistors and RF p-i-n diodes is considerably higher when taking into account the microstructure effects. Similarly, the response of diamond, SiO 2 , and GaAs photoconductive detectors (standard radiation diagnostics) is higher when taking into account the microstructure. This has obvious hardness assurance implications when assessing the transient response of devices because the measured photocurrent and dose rate levels could be underestimated if microstructure effects are not captured. Indeed, the rate the energy is deposited in a material during the microstructure peaks is much higher than the filtered rate which is traditionally measured. In addition, photocurrent models developed with filtered LINAC data may be inherently inaccurate if a device is able to respond to the microstructure.

43 PARTICLE ACCELERATORS↗

An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Industrial Application of Radioactive Ion Beams at the RIKEN RI Beam Factory

The Radioactive Ion Beam Factory (RIBF) at RIKEN is a heavy-ion accelerator facility that can provide intensive beams of radioactive isotopes (RI beam) produced at in-flight RI-beam separators. While the facility is used for experiments of various basic research fields, a new project has been started to open the facility to non-academic proposals from industry. We show an overview of the RIBF and the project of industrial use, and present a utilization of an RI-beam for development of wear diagnostics of industrial materials.

43 PARTICLE ACCELERATORS↗

Coronal Spectral Diagnostics: The Coronal Solar Magnetic Observatory (COSMO)

Understanding and predicting the major phenomena taking place in the solar corona, such as flares and Coronal Mass Ejections (CMEs), the heating and evolution of the solar atmosphere, and the acceleration of the solar wind, are fundamental challenges to predict our own star. These challenges are related to the solar magnetism and to the physical properties of solar plasmas: meeting them requires two types of measurements: A. Spectrally resolved, simultaneous observations of the entire corona in multiple spectral lines emitted by chromospheric to hot coronal plasmas at high spatial resolution and cadence for long periods of time; and B. Coronal magnetic field measurements.

Enrico Landi↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2023

NSLS-II accelerator physicists provided operation support for user operations and machine start-ups, carried out routine lattice characterization, and produced regular reports on beam dynamics. The commissioning of a superconducting wiggler for the HEX beamline is complete, and the wiggler effects on beam dynamics have been studied. A Facility Improvement Project for absolute lattice characterization has been approved and funded. We implemented and tested a new orbit-based technique of lattice characterization and correction. We developed a theory to calculate the beam-induced power in ceramic vacuum chambers and a new convergence map technique for nonlinear lattice characterization. We continued working on the NSLS-II upgrade including lattice development, commissioning a low-energy complex bend prototype, analyzing beam sensitivity to various errors, implementing higher-harmonic RF cavities, studying collective effects, and assessing FEL options. We also supported lattice optimization and beam diagnostics development for the EIC project. Main research accomplishments achieved in 2023, are summarized in this report.

43 PARTICLE ACCELERATORS↗

Real Time Tomography at the Swiss Light Source

The penetrating power of X-rays coupled with the high flux of 3rd generation synchrotron sources makes X-ray tomography to excel among fast imaging methods . To exploit this asset of synchrotron sources is the motivation for setting up an ultra-fast tomography endstation at the TOMCAT beamline. The state of the art instruments at synchrotron sources offer routinely a temporal resolution of tens of seconds in tomography. For a number of applications, for example biomedical studies, the relevant time scales (breathing, heartbeat) are rather in the range of 0.5-2 seconds. To overcome motion artifacts when imaging such systems a new ultra-fast tomographic data acquisition scheme is being developed at the TOMCAT beamline. We can acquire a full set of projections at sub-second timescale in monochromatic or white-beam configuration. We present a feasibility study with the ultimate aim to achieve sub-second temporal resolution in 3D without significant deterioration of the spatial resolution. For the first time, the 3D dynamics of the very early stages of a quickly aging liquid foam can be visualised with high quality and sufficiently large field of view.

43 PARTICLE ACCELERATORS↗

Polycrystalline diamond based detector for Z-pinch plasma diagnosis

A detector setup based on polycrystalline chemical-vapor-deposition diamond film is developed with great characteristics: low dark current (lower than 60 pA within 3 V/{mu}m), fast pulsed response time (rise time: 2-3 ns), flat spectral response (3-5 keV), easy acquisition, low cost, and relative large sensitive area. The characterizing data on Qiangguang-I accelerator show that this detector can satisfy the practical requirements in Z-pinch plasma diagnosis very well, which offers a promising prototype for the x-ray detection in Z-pinch diagnosis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of optical emission from the hydrogen plasma of the Linac4 ion source and the SPL plasma generator

At CERN, a non caesiated H{sup -} ion volume source derived from the DESY ion source is being commissioned. For a proposed High Power Superconducting Proton Linac (HP-SPL), a non caesiated plasma generator was designed to operate at the two orders of magnitude larger duty factor required by the SPL. The commissioning of the plasma generator test stand and the plasma generator prototype are completed and briefly described. The 2 MHz RF generators (100 kW, 50 Hz repetition rate) was successfully commissioned; its frequency and power will be controlled by arbitrary function generators during the 1 ms plasma pulse. In order to characterize the plasma, RF-coupling, optical spectrometer, rest gas analyzer and Langmuir probe measurements will be used. Optical spectrometry allows direct comparison with the currently commissioned Linac4 H{sup -} ion source plasma. The first measurements of the optical emission of the Linac4 ion source and of the SPL plasma generator plasmas are presented.

43 PARTICLE ACCELERATORS↗

A dual-channel, focusing x-ray spectrograph with uniform dispersion for Z pinch plasmas measurement

A dual-channel, focusing x-ray spectrograph with uniform dispersion (i.e., the linear dispersion of this spectrograph is a constant) is described for measuring the x-ray spectra emission from the hot, dense Al Z pinch plasmas. The spectrograph uses double uniform-dispersed crystals (e.g., a Quartz 1010 crystal and a Mica 002 crystal) as dispersion elements and a double-film box as detector to achieve the simultaneous recording of the time integrated spectrum covering a wide spectral range of {approx}5-9 A. Since this spectrograph disperse the x-rays on the detector plane with uniform spacing for every wavelength, it needs not the calibration of the wavelength with spatial coordinate, thereby own the advantages of easiness and veracity for spectra identification. The design of this spectrograph and the example of experiment on the ''Yang'' accelerator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗