Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography-proof of principle

Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 {micro}m polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3 M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANSCE nuclear science facilities and activities

Nuclear science activities at the Los Alamos Neutron Science Center (LANSCE) encompass measurements spanning the neutron energy range from thermal to 600 MeV. The neutron sources use spallation of the LANSCE 800 MeV pulsed proton beam with the time-of-flight technique to measure properties of neutron-induced reactions as a function of energy over this large energy range. Current experiments are conducted at the Lujan Center moderated neutron source, the unmoderated WNR target, and with a lead-slowing-down spectrometer. Instruments in use include the DANCE array of BaF{sub 2} scintillators for neutron capture studies, the FIGARO array of liquid scintillator neutron detectors, the GEANIE array of high-resolution HPGe x-ray and gamma-ray detectors, and a number of fission chambers, and other detectors. The LANL capabilities for production and handling of radioactive materials coupled with the neutron sources and detectors at LANSCE are enabling new and challenging measurements for a variety of applications including nuclear energy and nuclear astrophysics. An overview of recent research and examples of results is presented.

43 PARTICLE ACCELERATORS↗

Method and apparatus to digitize pulse shapes from radiation detectors

A field programmable gate array based multi-channel flash ADC unit combined with a high speed multi-lane data communications channel/Ethernet-like modular intercommunication providing a complete but easily expandable high-speed data acquisition system. This apparatus and method permits high-speed pulse-shape digitalization allowing position resolution imaging of particles having a range of energies and is scalable to achieve the efficient capture of coincident data from large electromagnetic detector arrays.

Weisenberger, Andrew↗

System, apparatus, and method for determining elemental composition using 4D STEM

The present disclosure relates to transmission electron microscopy for evaluation of biological matter. According to an embodiment, the present disclosure further relates to an apparatus for determining the structure and/or elemental composition of a sample using 4D STEM, comprising a direct bombardment detector operating with global shutter readout, processing circuitry configured to acquire images of bright-field disks using either a contiguous array or non-contiguous array of detector pixel elements, correct distortions in the images, align each image of the images based on a centroid of the bright-field disk, calculate a radial profile of the images, normalize the radial profiles by a scaling factor, calculate the rotationally-averaged edge profile of the bright-field disk, and determine elemental composition within the specimen based on the characteristics of the edge profile of the bright-field disk corresponding to each specimen location.

Bammes, Benjamin↗

Algorithms of pulse shape analysis for Gammasphere under high count rate conditions

The implementation of digital electronics for the multi-detector Gammasphere array has provided an opportunity to perform experiments which exceed the technical capabilities of its analog counterpart. The pulse shape analysis of HPGe detectors is presented for the purpose of determining the γ-ray energy under high-counting rates and short integration times with the aim of improving the data throughput. A revised trapezoidal algorithm is delineated which is able to determine the γ-ray energies during the offline analysis without being constrained by predetermined parameters. The performance of this algorithm is discussed, and compared with that of the analog system. The measured energy resolution meets expectations for operations with high-counting rates and short integration times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoconductive terahertz near-field detector with a hybrid nanoantenna array cavity

Nanoscale structuring of optical materials leads to modification of their properties and can be used for improving efficiencies of photonic devices and for enabling new functionalities. In ultrafast optoelectronic switches for generation and detection of terahertz (THz) radiation, incorporation of nanostructures allows us to overcome inherent limitations of photoconductive materials. We propose and demonstrate a nanostructured photoconductive THz detector for sampling highly localized THz fields, down to the level of λ/150. The nanostructure that consists of an array of optical nanoantennas and a distributed Bragg reflector forms a hybrid cavity, which traps optical gate pulses within the photoconductive layer. The effect of photon trapping is observed as enhanced absorption at a designed wavelength. This optically thin photoconductive THz detector allows us to detect highly confined evanescent THz fields coupled through a deeply subwavelength aperture as small as 2 μm (λ/150 at 1 THz). As a result, by monolithically integrating the THz detector with apertures ranging from 2 to 5 μm we realize higher spatial resolution and higher sensitivity in aperture-type THz near-field microscopy and THz time-domain spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr 3 (Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89 Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89 Zr through an (n, 2n) reaction on 90 Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Time Coincidence Measurements with Assemblies of HEU and DU Castings

Five highly enriched (93.2 wt% 235U) uranium (HEU) and three depleted (0.2 wt% 235U) uranium (DU) castings were available for passive time coincidence measurements with two arrays of eight total liquid scintillation detectors and two arrays of 32 total moderated 3He detectors. In addition to measurements with each type of casting, measurements were also performed with both types of castings intermingled. The spontaneous fission rate for the casting is primarily due to the presence of 238U. Thus, the DU castings have ~15 times more spontaneous fission that the HEU castings with very little addition in multiplication with each addition of a DU casting. The characteristic time behavior of the fission chain multiplication process is determined by the 235U. The presence of the DU castings in these assemblies has three physical effects: provision of an additional source of neutrons to initiate fission chains in the HEU, reflection of neutrons back into the HEU, and shielding of the detectors from fission chain neutrons and gammas. The effects are investigated within the context of the time coincidence distributions using the signal-triggered multiplets and Feynman variances.

36 MATERIALS SCIENCE↗

Direct Deposition of Microcolumnar Scintillator on CMOS SSPM Array: Toward a Photon Counting Detector for X-Ray/Gamma Ray Imaging

We are developing a modular, low-cost, photon-counting detector based on a scintillator coupled to a solid-state photodetector. A working prototype was successfully developed by depositing CsI:Tl directly onto a CMOS SSPM array designed by RMD and custom-fabricated by a commercial foundry. The device comprised a 6x6 array of 1.5x1.5 mm{sup 2} macro-pixels, each containing a 36x36 array of resistively coupled micro-pixels, that was subjected to vapor deposition of columnar CsI:Tl. Direct deposition eliminates the gap between the scintillator and SSPM and creates a better optical bond than does index-matching grease. This paper compares the performance of SSPMs with directly deposited CsI:Tl, in terms of signal-to-noise ratio and light spread, against devices using monolithic single crystals or pixelated single crystals coupled to the SSPM. Due to the reduction in light scattering and optical losses in the interface, the directly deposited CsI:Tl demonstrated significantly better position sensitivity, with at least a factor of 2 increase in SNR compared to a single crystal. These data indicate that a photodetector with substantially smaller macro-pixel dimensions than used here could be used to implement a low-energy X-ray/gamma-ray imaging and spectroscopy detector, particularly for applications where high resolution is of prime importance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors

Purpose: In this paper, a photomultiplier tube (PMT) array dosimetry system has been developed and tested for the real-time readout of multiple scintillation signals from fiber optic dosimeters. It provides array dosimetry with the advantages in sensitivity provided by a PMT, but without the need for a separate PMT for each detector element. Methods: The PMT array system consisted of a multianode PMT, a multichannel data acquisition system, housing and optic fiber connections suitable for clinical use. The reproducibility, channel uniformity, channel crosstalk, acquisition speed, and sensitivity of the PMT array were quantified using a constant light source. Its performance was compared to other readout systems used in scintillation dosimetry. An in vivo HDR brachytherapy treatment was used as an example of a clinical application of the dosimetry system to the measurement of dose at multiple sites in the rectum. The PMT array system was also tested in the pulsed beam of a linear accelerator to test its response speed and its application with two separate methods of Cerenkov background removal. Results: The PMT array dosimetry system was highly reproducible with a measurement uncertainty of 0.13% for a 10 s acquisition period. Optical crosstalk between neighboring channels was accounted for by omitting every second channel. A mathematical procedure was used to account for the crosstalk in next-neighbor channels. The speed and sensitivity of the PMT array system were found be superior to CCD cameras, allowing for measurement of more rapid changes in dose rate. This was further demonstrated by measuring the dose delivered by individual photon pulses of a linear accelerator beam. Conclusions: The PMT array system has advantages over CCD camera-based systems for the readout of scintillation light. It provided a more sensitive, more accurate, and faster response to meet the demands of future developments in treatment delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PIN Diode Detectors

A review of the application of PIN diodes as radiation detectors in particle counting, X- and {gamma}-ray spectroscopy, medical applications and charged particle spectroscopy is presented. As a practical example of its usefulness, a PIN diode and a low noise preamplifier are included in a nuclear spectroscopy chain for X-ray measurements. This is a laboratory session designed to review the main concepts needed to set up the detector-preamplifier array and to make measurements of X-ray energy spectra with a room temperature PIN diode. The results obtained are compared with those obtained with a high resolution cooled Si-Li detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital front-end electronics for a tagged neutron inspection system

In this paper, we shall present a simple VME front-end system that employs the FADC CAEN V1720 8- channel 12-bit 250-MS/s digitizer. This system produces coincidence spectra between the trigger particle and other detectors and it replaces the traditional technique of chaining analog electronics. Tests have been performed using a pulser working at different frequencies as well as employing a {sup 252}Cf source in concert with an array of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Design and Performance of the First BICEP Array Receiver

Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity “B-mode” pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision σ(r) between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. Here in this paper, we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-135: Dosimetric Properties of the OCTAVIUS Detector 1500

Purpose: In this study the dosimetric properties of the Octavius Detector 1500 array (PTW-Freiburg-Germany) are investigated. Methods: The chambers of the array, each with an entrance window of 4.4 × 4.4 cm{sup 2}, are arranged in a checkerboard pattern in a measurement area of 27 × 27 cm{sup 2} with a sampling frequency of 0.1 mm{sup −1} along each row which can be doubled by merging two measurements shifted by 5 mm. Linearity, stability and output factors were measured with either a Semiflex 31013 or 31010 as a reference detector. Output factors were additionally measured with a Diode 60012. The effective point of measurement was determined by comparing TPR curves of the array with Roos chamber 34001 measurements. The lateral dose response function of a single chamber was determined by comparison with a high resolution diode. An IMRT field verification was carried out with a merged OD1500 measurement. Results: The OD1500 was stable within ±0.15 %. Deviations in linearity did not exceed 1% from 5 to 1000 MU. The effective point of measurement was 8.2 mm below the surface. Deviations in output factors were below 0.77 % from 5 × 5 to 27 × 27 cm{sup 2}. As expected for the smallest field of 1 × 1 cm{sup 2}, the deviation from the diode was significant. The widths of the lateral dose response functions were σ{sup 6} = (2.07 ± 0.03) mm and σ{sup 15} = (2.09 ± 0.03) mm. Gamma Index passing rates for typical IMRT and VMAT plans were above 90 % compared to film and TPS calculations for a local 3 mm / 3 % criterion. Conclusion: The first measurements with the OD1500 array show the excellent applicability of the array for clinical dosimetry. The response of the array to the mean photon energy and dose per pulse are under investigation.

60 APPLIED LIFE SCIENCES↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗