Search NASA⌕ Search

SEARCH · Search NASA

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Building America Energy Renovations: A Business Case for Home Performance Contracting

This research report gives an overview of the needs and opportunities that exist in the U.S. home performance contracting industry. The report discusses industry trends, market drivers, different business models, and points of entry for existing and new businesses hoping to enter the home performance contracting industry. Case studies of eight companies who successfully entered the industry are provided, including business metrics, start-up costs, and marketing approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technology Solutions Case Study: Monitoring of Double Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts

Double stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. In this project, Building Science Corporation monitored moisture conditions in double-stud walls from 2011 through 2014 at a new production house located in Devens, Massachusetts. The builder, Transformations, Inc., has been using double-stud walls insulated with 12 in. of open cell polyurethane spray foam (ocSPF); however, the company has been considering a change to netted and blown cellulose insulation for cost reasons. Cellulose is a common choice for double-stud walls because of its lower cost (in most markets). However, cellulose is an air-permeable insulation, unlike spray foams, which increases interior moisture risks. The team compared three double-stud assemblies: 12 in. of ocSPF, 12 in. of cellulose, and 5-½ in. of ocSPF at the exterior of a double-stud wall (to approximate conventional 2 × 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies.

BSC↗

Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.

Airborne particles↗

DOE Zero Energy Ready Home Case Study: Mandalay Homes, Phoenix, Arizona

This builder built fourteen homes in the Gordon Estates subdivision that achieved Challenge Home certification with HERS 38–58 on an affordable budget for homeowners. Every Mandalay home in the development also met the National Green Building Standard gold level. The Gordon Estates subdivision is also serving as a showcase of energy efficiency, and Mandalay is hosting education workshops for realtors, state and local officials, other builders, students, potential homeowners, and the public. The builder won a 2013 Housing Innovation Award in the affordable builder category.

Building America↗

The Role of Sensitivity Analysis in the Building Performance Analysis: A Critical Review

A building system is highly nonlinear and commonly includes a variety of parameters ranging from the architectural design to the building mechanical and energy system. Serving as a powerful tool to understand the complicated building system, sensitivity analysis (SA) has been receiving increasing attention in the recent decade. This review paper focused on the application of SA in the building performance analysis (BPA). First, the existing review papers on the application of SA for BPA were briefly reviewed and summarized. Then, a large amount of recent SA case studies in BPA were reviewed. The critical information regarding the implementation of a SA, such as the sampling method, the SA method, etc., were extracted and summarized. Next, an extensive analysis was performed to evaluate the role of the SA in the BPA. This includes: 1) The typical selection of the input and output parameters for the SA were visualized; 2) The uncertainty level and sampling strategies for the input parameters were investigated; 3) The principles, benefits, and drawbacks of the SA methods were analyzed and summarized; and 4) The various tools used in the SA, including the simulation software, sampling tools, and SA tools were introduced to facilitate the practitioners. Lastly, several conclusions were summarized on the role of the SA in the BPA. Suggestions were also provided to offer practical solutions to the current challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rethinking HVAC temperature setpoints in commercial buildings: The potential for zero-cost energy savings and comfort improvement in different climates, Building and Environment

Heating, Ventilation, and Air Conditioning (HVAC) systems are responsible for a significant share of the energy consumed in commercial buildings. While energy system retrofits have been found to reduce buildings' carbon footprint substantially, these measures are often hindered by financial, regulatory or design constraints. Recent research sheds light on energy management approaches to energy conservation such as energy-efficient settings of HVAC temperature setpoints. While existing case studies confirm the significant energy saving potential of efficient HVAC operation, there is scarcity of studies quantifying energy savings from optimal HVAC temperature setpoints comprehensively, while controlling for important factors, such as guaranteeing tenant thermal comfort levels and the impact of different climate conditions on the results. In this work, we apply simulation-based multi-objective optimization to fine-tune heating and cooling setpoints of large “typical” office buildings with respect to energy consumption and occupant thermal comfort. We apply the framework in seven climate zones across the US in an effort to examine spatial variations in the energy savings potential due to different climate conditions and propose targeted energy-saving strategies and policies. We show that locations with mild climates, such as San Francisco, CA, can realize up to 60% of annual HVAC-related energy savings without compromising the occupants' thermal comfort. This untapped potential to simultaneously improve building performance and occupants’ comfort drives the discussion on revisiting HVAC setpoint configuration standards in commercial buildings, either as part of individual building retrofit planning or as part of energy policy regulations.

Papadopoulos, Sokratis↗

A Case Study of Tunable White LED Lighting with Networked Lighting Controls (Emory University Cognitive Empowerment Program)

Emory University and Georgia Institute of Technology (Georgia Tech) partnered to create the Charlie and Harriet Schaffer Cognitive Empowerment Program (CEP) facility in northeast Atlanta. Together with the funders they are building a program to help individuals experiencing mild cognitive impairment (MCI) to maintain their physical and cognitive health, and independence as long as possible. In addition to applying effective strategies and therapies, the two research groups are investigating the responses of the MCI members to treatments that involve acoustical conditions, exercise and movement, and lighting changes that may support retention or relearning of skills. Care partners and family members receive support and instruction to improve home and work life, promoting joy, purpose, and wellness in the family groups. The lighting system uses tunable-white LEDs, employing luminaires with both warm and cool-color emitters that can be dimmed separately to produce any white correlated color temperature (CCT) between 2700 K and 6500 K. All luminaires were dimmable to achieve subdued or lively surroundings for different treatments, time-of-day, and mood. A central networked digital control system was employed to allow tuning of multiple spaces together (for example, bright, cool morning light could be programmed for extra stimulation, or lighting in all spaces at the end of the day could be reduced in both light output and CCT to promote relaxation and not interfere with the melatonin cycle of occupants). Almost all spaces were equipped with individual room control of dimming and color temperature with touch screens to allow users to tune the lighting as desired, but each room’s controls could also be specially programmed through the server in case the research staff were investigating lighting settings on learning, for example. The server incorporates a timeclock, and it is able to send signals to switch off all lighting after occupancy hours, or enable occupancy sensors to control the lighting. The bulk of the construction work was completed in January 2020. It was clear from an initial walk-through that although the lighting system produced the expected high light level with low-glare qualities of light, that there were issues and inconsistencies to be resolved. These were noted in an initial punchlist visit and expected to be resolved when the tech representatives from the agency visited with the electrical contractor in the following few weeks. What followed was 2.5 years of identifying unexpected lighting performance in terms of light output, color, scheduling, and occupancy. This report documents the issues encountered in the effort to get the lighting and controls systems to operate as intended. It concludes with guidance for design professionals and manufacturers to help avoid problematic complexity in future projects.

42 ENGINEERING↗

2018 NISAR Applications Workshop: Forest and Disturbance; Workshop Report

Forest lands cover the globe and are important sources for providing ecosystem services including: carbon sequestration, biodiversity, timber, air and water quality. As such, counties around the world have dedicated programs for managing them. Accurate and timely information concerning the status of these forests (moisture, biomass, disturbance type, etc.) is essential to those Nations’ human and ecological health as well as economy. The joint NASA/US Forest Service workshop focused on arming forest land managers with observations and remote sensing information from the upcoming NASA-ISRO (Indian Space Research Organization) SAR (Synthetic Aperture Radar) (NISAR) satellite mission (expected to launch early 2022). Participants included representatives from different US Federal Agencies, private sector, and non-governmental organizations (NGO) that are key players in facilitating integration of Earth Observations (EO) into forest management and decision support workflows. They included scientists, technicians, and program managers with a responsibility for data acquisition and exploitation such as product development, delivery, and use, and capacity building. Discussions were held over two days to convey the broader forest and disturbance community information needs for various representative participants and programs and to facilitate the delivery of NISAR mission geospatial products and observational capabilities. Case studies were presented to demonstrate the current state of practice in the use of SAR remote sensing for applications of direct importance to forest and disturbance land management community. Eleven organizations presented their information requirements in response to a set of questions provided by the NASA team, then the NASA team responded by describing the degree to which NISAR could meet these requirements. Discussion ensued about needed data product specifications to increase utility (e.g., projection, latency, etc.), tools and capacity building. The general findings of this workshop were that (a) NISAR observations will be particularly useful to the global forest carbon and disturbance monitoring applications, but that certain data product design decisions (projections and radiometric and terrain corrections) need to be considered to increase utility; b) the biomass and disturbance detection algorithms meet many of the community needs, however there are other information products of value (e.g., soil moisture or disturbance classification, not just detection) and all products should be compliant with existing community standards for reporting uncertainty; c) providing SAR education to the community will be key specifically thinking about putting the information first and the SAR theory second, providing a simple guide of standard data processing steps (e.g., dB (decibel) to power conversion and speckle filtering); d) the community needs a user-friendly interface for finding free, archived data over their geographic regions of interest; e) user-friendly tools that connect to open-sources GIS (Global Information System) software (e.g., QGIS (Quantum GIS)) that include a graphical user interface (GUI) for SAR processing that enables both download and cloud processing. To integrate these findings and prepare the community before NISAR launches, it was suggested that there be a dedicated NISAR Forest and Disturbance Applications Working Group (as per the specifications in the NISAR Utilization Plan). After launch, it was decided that the community continue capacity building activities.

Stavros, Natasha↗

Coupling Power System Dynamics and Building Dynamics to Enable Building-to-Grid Integration

The interactions between power system dynamics and building dynamics are usually ignored or over-simplified in existing power systems and building modeling and simulation tools, which limits how system modeling can sup-port Building-to-Grid integration. This paper discusses a new approach to consider those interactions by model-ing motor-driven building devices or systems. The motor-driven model is based on simplified mechanical rotation equations and allows us to study the coupling relationship between frequency/voltage in the power system and motor-driven device operation. This model is validated by performing one proof-of-concept case study with Modelica. The simulation results suggest that the proposed model can yield better representations of these interactions than the existing simplified models, especially the ones with the fast transient dynamics.

Buildings-to-grid integration, motor, coupling sim↗

Activity coefficient acquisition with thermodynamics–informed active learning for phase diagram construction

This work explores the use of thermodynamics-informed Gaussian processes (GPs) and active learning (AL) to model activity coefficients and construct phase diagrams. Relying on synthetic data generated from an excess Gibbs energy model, GPs were found to accurately describe the activity coefficients of several binary mixtures across large composition and temperature ranges. Moreover, GPs could estimate their own uncertainty and identify composition/temperature regions where activity coefficient data provide the most information to the models. This was leveraged to build AL algorithms targeted at modeling phase equilibria. In many cases, a single active-learning-acquired data point was sufficient to describe the phase diagrams studied. Lastly, the ability of AL to greatly reduce the amount of data needed to obtain accurate models was further verified on experimental case studies, namely individual ion activity coefficients, the solid–liquid and vapor–liquid equilibrium of deep eutectic solvents, and phase equilibria in ternary mixtures.

25 ENERGY STORAGE↗

Solar cities: A case study analysis of city-level enablers of expanded solar energy access

Rooftop solar photovoltaic (PV) adoption can benefit households by reducing electricity bills and enhancing energy resiliency. Low and moderate-income (LMI) households have been less likely to adopt PV and experience these benefits in the United States than higher-income households. Adopter income trends are often explored through quantitative analysis with limited explanatory power. Our quantitative analysis only explains around one-third of city-level variation in LMI adoption trends through socioeconomic factors such as median home values and income inequality and PV market factors such as cumulative adoption and incentives. We implement semi-structured interviews in three case studies of cities with relatively high rates of LMI PV adoption to better understand the factors that explain PV adopter income trends. The case studies partly reiterate findings from quantitative analysis, such as the role of PV incentives. The case studies reveal a broader set of LMI adoption drivers that are missed in quantitative analyses. The case studies show how city contexts can affect LMI adoption, such as the role of supportive city governments. The case studies also reveal the importance of partnerships, such as partnerships between city governments and state LMI PV program implementers. Finally, interviewees emphasized the importance of building trust among prospective LMI PV adopters. Interviewees suggested that partnerships, outreach, and consumer protection measures were crucial to building trust in PV installers among LMI households.

Adoption↗

A crotonyl-CoA reductase-carboxylase independent pathway for assembly of unusual alkylmalonyl-CoA polyketide synthase extender units

Type I modular polyketide synthases assemble diverse bioactive natural products. Such multienzymes typically use malonyl and methylmalonyl-CoA building blocks for polyketide chain assembly. However, in several cases more exotic alkylmalonyl-CoA extender units are also known to be incorporated. In all examples studied to date, such unusual extender units are biosynthesized via reductive carboxylation of α, β-unsaturated thioesters catalysed by crotonyl-CoA reductase/carboxylase (CCRC) homologues. Here we show using a chemically-synthesized deuterium-labelled mechanistic probe, and heterologous gene expression experiments that the unusual alkylmalonyl-CoA extender units incorporated into the stambomycin family of polyketide antibiotics are assembled by direct carboxylation of medium chain acyl-CoA thioesters. X-ray crystal structures of the unusual β-subunit of the acyl-CoA carboxylase (YCC) responsible for this reaction, alone and in complex with hexanoyl-CoA, reveal the molecular basis for substrate recognition, inspiring the development of methodology for polyketide bio-orthogonal tagging via incorporation of 6-azidohexanoic acid and 8-nonynoic acid into novel stambomycin analogues.

Science & Technology - Other Topics↗

PARETO 0.3.0 Release

PARETO 0.3.0 Release. Highlights: - Fixing Warning in get_data - Clean up of old main function which has been replaced by the run files - Adding plot_scatter() function - Support node capacity - Add Gurobi troubleshooting files to gitignore by @melody-shellman - Set slacks to zero - Water treatment case study - Fix defaultvalue treatement - Fix bug for incorrect number of input arguments in water quality - Pipeline configs documentation - Enable rendering Unicode characters in ReadTheDocs PDF builds - Adding support for units - Add discrete water quality to the model - Updating documentation for strategic model, and corresponding fixes to strategic model - Rework getting started docs build section and more - Enable Codecov reports in CI builds - Correct error in CompletionsPadSupplyBalanceRule

PARETO,PSE,Process Systems Engineering,Produced wa↗

Multilingual Connotation Frames: A Case Study on Social Media for Targeted Sentiment Analysis and Forecast

People around the globe respond to major real world events through social media. To study targeted public sentiments across many languages and geographic locations, we introduce multilingual connotation frames: an extension from English connotation frames of Rashkin et al. (2016) with 10 additional European languages, focusing on the implied sentiments among event participants engaged in a frame. As a case study, we present large scale analysis on targeted public sentiments using 1.2 million multilingual connotation frames extracted from Twitter. We rely on connotation frames to build models to forecast country-specific connotation dynamics – perspective change over time towards salient entities and events. Our results demonstrate that connotation dynamics can be accurately predicted up to half a week in advance.

connotation frames↗

Contributions to the acoustic protection of civil buildings taking into account the use of light prefabs

Usually it is expensive to obtain suitable damping coefficients for exterior and interior walls made up of light materials. Hence, acoustic protection problems must be tackled in parallel with the design and introduction of new types of elements. A comparison of classical solutions shows that interior separating walls raise the most difficult problems. In order to reduce building costs it is necessary to make a careful study of architectural solutions and to provide for wall structures with characteristics that vary with the particular case.

Smigelschi, M.↗

Advanced Symbolic Analysis Tools for Fault-Tolerant Integrated Distributed Systems

The project aims to develop advanced model-checking algorithms and tools to automate the verification of fault-tolerant distributed systems for avionics. We present a new method called Property-Directed K-Induction (PD-KIND) for synthesizing K-inductive invariants of state-transition systems. PD-KIND builds upon Satifiability Modulo Theories (SMT) to generalize Bradley's IC3 method and its variants. This method is implemented in a new tool called SALLY. Case studies show that PD-KIND can automatically verify fault-tolerant algorithms under a variety of fault models and that SALLY is competitive with other SMT-based model checkers.

Dutertre, Bruno↗

Technology Solutions Case Study: Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

air conditioning↗

Additive Manufacturing Case Study

Geothermal technologies include an extremely wide range of products required for well construction, completion, production, intervention and surface energy conversion activities. Many of these products are geometrically complex, require multi-step and highly specialized fabrication processes, and are expensive due to the low production numbers typically associated with the geothermal market. These challenges along with the high temperature demands of the geothermal environment have also hindered the adoption of many tools routinely used in the oil & gas industry.Recent advancements in Additive Manufacturing (AM) materials of construction, build volumes and part quality have transitioned the technology from primarily cosmetic prototyping applications to the point where AM can be used to make production parts, even for the most demanding applications. These improved AM capabilities along with the inherent ability of AM to produce complex parts and, in some cases, geometries that cannot be manufactured using conventional casting, machining and joining fabrication approaches motivate an exploration of its potential to positively impact geothermal well construction and operations technologies.Sandia National Labs collaborated with Oak Ridge National Laboratory on a case study examining additive manufacturing opportunities for Geothermal applications. The study focused on designing components with improved performance characteristics that cannot be fabricated conventionally. A rotor for a downhole motor was chosen based on the potential for improving its rotational dynamics. Topology optimization was used as a design method to reduce the rotational inertia of the part while preserving sufficient rotational stiffness to transmit the torque required for the drilling application. The optimization resulted in a nearly 50% reduction in polar moment of inertia while maintaining other desired performance characteristics. The design developed using the topology optimization approach was fabricated using additive manufacturing and cannot be fabricated conventionally. This paper will discuss the design approach, performance improvements and manufacturing methods used to produce the part.

Polsky, Yarom↗