Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Preparing for the Next Generation of EUV Lithography at the Center for X-ray Optics

The introduction of EUV lithography into high-volume semiconductor manufacturing this year represents a monumental milestone for EUV technology. After nearly 30 years of development, the EUV research community has overcome many of the key obstacles required to enable the long-awaited integration of EUV lithography into the lab. These obstacles have included: the development of a stable, high-powered EUV source to ensure adequate exposure tool reliability; controlling EUV mask defects and mask contamination; and the development of EUV resists with adequate sensitivity, resolution, and line width roughness to meet the tolerances required for high-volume manufacturing. As EUV moves into its second generation, there will be new challenges facing the community as it works to push EUV technology into the future. Smaller feature sizes will be achieved using higher numerical aperture optics, which are planned to have an anamorphic geometry (asymmetric magnification and numerical aperture between horizontal and vertical axes) to overcome 3D effects at the mask. This new geometry and its larger angle ranges make understanding mask absorber and multilayer effects all the more important. New methods for high-NA wavefront metrology need to be tested to ensure that these optical systems can be aligned to operate with minimal aberrations. Mask defects need to continue to be studied, and the inclusion of EUV pellicles in the roadmap requires that mask inspection and review systems adapt accordingly. Finally, new resists must be developed to support the increased resolution of feature sizes below 8 nm half pitch. The Center for X-ray Optics (CXRO) at Berkeley Lab has been a leader in EUV research for the past 25 years. Leveraging 13.5 nm EUV light from the Advanced Light Source synchrotron facility, CXRO is home to several EUV and soft X-ray (SXR) research tools that have provided important insights into EUV resists, masks, and coatings. The 0.3 NA Microfield exposure tool (MET) and Dose Calibration Tool (DCT) have played an instrumental role in the development of the current generation of high-resolution EUV resists. The Actinic Inspection Tool (AIT) and its successor, SHARP, have enabled aerial image analysis, providing key insights into mask defects, 3D mask effects, illumination, and aberrations. And the CXRO Reflectometer continues to be the industry standard in multilayer coating and EUV mask scattering metrology. To address the new challenges facing the next generation of EUV lithography, CXRO has upgraded its suite of EUV research tools. The 0.5 NA MET5 is a newly commissioned projection lithography tool that is capable of printing feature sizes down to 8 nm half pitch. A new radiation chemistry program is deploying several techniques aimed at dissecting the role of primary photoelectrons and secondary electrons in EUV resists. The SHARP microscope has been outfitted with anamorphic zone plate lenses that can emulate the geometry of next-generation EUV scanners, and the reflectometer has been applied to new scattering experiments for the purpose of understanding the 3D effects of EUV mask multilayers, as well as determining mask properties using scattering profiles. In parallel with these tools, the CXRO High-NA Wavefront Sensing Program is developing high-resolution wavefront sensors suitable for measuring aberrations at high NA. This article presents an overview of these programs and describes how they will address the primary challenges that face the EUV community as it moves to the next generation of EUV lithography.

47 OTHER INSTRUMENTATION↗

Degenerate Ising model for atomistic simulation of crystal-melt interfaces

One of the simplest microscopic models for a thermally driven first-order phase transition is an Ising-type lattice system with nearest-neighbour interactions, an external field, and a degeneracy parameter. The underlying lattice and the interaction coupling constant control the anisotropic energy of the phase boundary, the field strength represents the bulk latent heat, and the degeneracy quantifies the difference in communal entropy between the two phases. We simulate the (stochastic) evolution of this minimal model by applying rejection-free canonical and microcanonical Monte Carlo algorithms, and we obtain caloric curves and heat capacity plots for square (2D) and face-centred cubic (3D) lattices with periodic boundary conditions. Since the model admits precise adjustment of bulk latent heat and communal entropy, neither of which affect the interface properties, we are able to tune the crystal nucleation barriers at a fixed degree of undercooling and verify a dimension-dependent scaling expected from classical nucleation theory. We also analyse the equilibrium crystal-melt coexistence in the microcanonical ensemble, where we detect negative heat capacities and find that this phenomenon is more pronounced when the interface is the dominant contributor to the total entropy. The negative branch of the heat capacity appears smooth only when the equilibrium interface-area-to-volume ratio is not constant but varies smoothly with the excitation energy. Finally, we simulate microcanonical crystal nucleation and subsequent relaxation to an equilibrium Wulff shape, demonstrating the model's utility in tracking crystal-melt interfaces at the atomistic level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

Purpose: Feasibility of targeted and volumetric hyperthermia (40–45 °C) delivery to the prostate with a commercial MR-guided endorectal ultrasound phased array system, designed specifically for thermal ablation and approved for ablation trials (ExAblate 2100, Insightec Ltd.), was assessed through computer simulations and tissue-equivalent phantom experiments with the intention of fast clinical translation for targeted hyperthermia in conjunction with radiotherapy and chemotherapy. Methods: The simulations included a 3D finite element method based biothermal model, and acoustic field calculations for the ExAblate ERUS phased array (2.3 MHz, 2.3 × 4.0 cm{sup 2}, ∼1000 channels) using the rectangular radiator method. Array beamforming strategies were investigated to deliver protracted, continuous-wave hyperthermia to focal prostate cancer targets identified from representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Preliminary experiments included beamformed sonications in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Results: Acoustic intensities considered during simulation were limited to ensure mild hyperthermia (T{sub max} < 45 °C) and fail-safe operation of the ExAblate array (spatial and time averaged acoustic intensity I{sub SATA} < 3.4 W/cm{sup 2}). Tissue volumes with therapeutic temperature levels (T > 41 °C) were estimated. Numerical simulations indicated that T > 41 °C was calculated in 13–23 cm{sup 3} volumes for sonications with planar or diverging beam patterns at 0.9–1.2 W/cm{sup 2}, in 4.5–5.8 cm{sup 3} volumes for simultaneous multipoint focus beam patterns at ∼0.7 W/cm{sup 2}, and in ∼6.0 cm{sup 3} for curvilinear (cylindrical) beam patterns at 0.75 W/cm{sup 2}. Focused heating patterns may be practical for treating focal disease in a single posterior quadrant of the prostate and diffused heating patterns may be useful for heating quadrants, hemigland volumes or even bilateral targets. Treatable volumes may be limited by pubic bone heating. Therapeutic temperatures were estimated for a range of physiological parameters, sonication duty cycles and rectal cooling. Hyperthermia specific phasing patterns were implemented on the ExAblate prostate array and continuous-wave sonications (∼0.88 W/cm{sup 2}, 15 min) were performed in tissue-mimicking material with real-time MR-based temperature imaging (PRFS imaging at 3.0 T). Shapes of heating patterns observed during experiments were consistent with simulations. Conclusions: The ExAblate 2100, designed specifically for thermal ablation, can be controlled for delivering continuous hyperthermia in prostate while working within operational constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose Hypofractionated Proton Beam Radiation Therapy Is Safe and Effective for Central and Peripheral Early-Stage Non-Small Cell Lung Cancer: Results of a 12-Year Experience at Loma Linda University Medical Center

Purpose: We update our previous reports on the use of hypofractionated proton beam radiation therapy for early-stage lung cancer patients. Methods and Materials: Eligible subjects had biopsy-proven non-small cell carcinoma of the lung and were medically inoperable or refused surgery. Clinical workup required staging of T1 or T2, N0, M0. Subjects received hypofractionated proton beam therapy to the primary tumor only. The dose delivered was sequentially escalated from 51 to 60 Gy, then to 70 Gy in 10 fractions over 2 weeks. Endpoints included toxicity, pulmonary function, overall survival (OS), disease-specific survival (DSS), and local control (LC). Results: One hundred eleven subjects were analyzed for treatment outcomes. The patient population had the following average characteristics; age 73.2 years, tumor size 3.6 cm, and 1.33 L forced expiratory volume in 1 second. The entire group showed improved OS with increasing dose level (51, 60, and 70 Gy) with a 4-year OS of 18%, 32%, and 51%, respectively (P=.006). Peripheral T1 tumors exhibited LC of 96%, DSS of 88%, and OS of 60% at 4 years. Patients with T2 tumors showed a trend toward improved LC and survival with the 70-Gy dose level. On multivariate analysis, larger tumor size was strongly associated with increased local recurrence and decreased survival. Central versus peripheral location did not correlate with any outcome measures. Clinical radiation pneumonitis was not found to be a significant complication, and no patient required steroid therapy after treatment for radiation pneumonitis. Pulmonary function was well maintained 1 year after treatment. Conclusions: High-dose hypofractionated proton therapy achieves excellent outcomes for lung carcinomas that are peripherally or centrally located. The 70-Gy regimen has been adopted as standard therapy for T1 tumors at our institution. Larger T2 tumors show a trend toward improved outcomes with higher doses, suggesting that better results could be seen with intensified treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon Ion Radiation Therapy for Unresectable Sacral Chordoma: An Analysis of 188 Cases

Purpose: To evaluate the results of carbon ion radiation therapy administered to 188 patients with unresectable primary sacral chordomas. Patients and Methods: One hundred eighty-eight patients were treated with carbon ion radiation therapy at a single institute between 1996 and 2013 and retrospectively analyzed. The median age was 66 years. The highest proximal invasion reached past S2 level in 137 patients. The median clinical target volume was 345 cm{sup 3}. One hundred six patients received 67.2 gray equivalents (GyE)/16 fractions (fr), 74 patients received 70.4 GyE/16 fr, 7 patients received 73.6 GyE/16 fr, and 1 patient received 64.0 GyE/16 fr. Results: The median follow-up period was 62 months (range, 6.8-147.5 months). Seventy percent of patients were followed for 5 years or until death. The 5-year local control, overall survival, and disease-free survival rates were 77.2%, 81.1%, and 50.3%, respectively. Forty-one patients had a local recurrence. Sex, tumor volume, level of proximal invasion, and irradiated dose were unrelated to local control. There was grade 3 toxicity of the peripheral nerves in 6 patients and grade 4 toxicity of the skin in 2 patients. Ambulation remained in 97% of patients. Conclusions: Carbon ion radiation therapy was safe and effective for unresectable chordoma and provided good local control and survival while preserving ambulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Movement-Based Traffic Volume Prediction at Signalized Intersections

The traffic volume of each movement at signalized intersections can provide valuable information on real-time traffic conditions that enable traffic control systems to dynamically respond to the fluctuated traffic demands. Real-time movement-based traffic volume prediction is challenging due to various nonlinear spatial relationships at different locations/approaches and the complicated underlying temporal dependencies. In this study, a novel deep intersection spatial-temporal network (DISTN) is developed for real-time movement-based traffic volume prediction at signalized intersections, which considers both spatial and temporal features by the convolutional neural network (CNN) and long short-term memory (LSTM), respectively. In addition, the within-day, daily, and weekly periodic trends of traffic volume are also considered in the proposed model. This is the first time that a deep-learning method has been applied for movement-based traffic volume prediction at signalized intersections. In the numerical experiment, the proposed model is evaluated using real-world data and simulation data to demonstrate its effectiveness. The impacts of various structures of traffic networks on the proposed model are also discussed. Results show that the proposed model outperforms some of the state-of-the-art volume prediction methods currently in the literature.

99 GENERAL AND MISCELLANEOUS↗

Synergies between radio, optical and microwave observations at high redshift

In this work, we study synergies between three promising methods to measure 2 2 and suffer from interloper problems even for spectroscopic surveys. Intensity mapping of the 21-cm signal can cover large volumes with exquisite fidelity, but is limited both by loss of information to foreground cleaning and by lack of knowledge of the mean signal. Cosmic microwave background (CMB) lensing is theoretically very clean, but ultimately measures just the projected variations in density. We find that cross-correlation between optical and radio can significantly improve the measurement of growth rate. Combining these with the CMB provides a promising avenue to detecting modified gravity at high redshifts, in particular by independently probing the Weyl and Newtonian potentials and by strengthening control of systematics. We find that cross-correlating a Stage {\sc ii} 21-cm survey with DESI quasars with a reasonable brightness temperature prior could enable measurements of the growth rate fσ 8 at sub 3% and sub 8% levels at z = 3, 4, representing a factor of 4 and 8 improvement over constraints obtainable from DESI quasars alone. Similarly, cross-correlating 21-cm data with a futuristic LBG survey to m UV <24.5 over 1000 square degrees will make possible fσ 8 measurements at close to 1% at z = 3 and 3% at z = 4, and improve similar constraints at z = 5 by close to a factor of 3 to sub-10% precision. Finally, combining the above with CMB lensing from a Stage 4 CMB survey and LSST data can additionally constrain the gravitational slip γ parameter to similar precision at these redshifts, enabling us to test the predictions of general relativity at large scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method for solid state crystal growth

A novel method for high quality crystal growth of intermetallic clathrates is presented. The synthesis of high quality pure phase crystals has been complicated by the simultaneous formation of both clathrate type-I and clathrate type-II structures. It was found that selective, phase pure, single-crystal growth of type-I and type-II clathrates can be achieved by maintaining sufficient partial pressure of a chemical constituent during slow, controlled deprivation of the chemical constituent from the primary reactant. The chemical constituent is slowly removed from the primary reactant by the reaction of the chemical constituent vapor with a secondary reactant, spatially separated from the primary reactant, in a closed volume under uniaxial pressure and heat to form the single phase pure crystals.

36 MATERIALS SCIENCE↗

Radiation Therapy for Treatment of Pigmented Villonodular Synovitis: Results of a National Patterns of Care Study

Purpose: The German Cooperative Group on Radiotherapy in Benign Diseases (GCG-BD) conducted a pattern-of-care study (PCS) to analyze the radiation therapy (RT) practice for pigmented villonodular synovitis (PVNS). Methods and Materials: In 2007, a structured questionnaire to assess the number of patients, the pretreatments, the RT indication, technique, target volume concepts, outcome data, and possible early or late toxicity was circulated to 227 institutions. Results: Until August 2008, a response was available from 189 institutions (83.2 %), of whom 19 (10.0 %) experienced RT for PVNS. Complete clinical information was available for 41 patients from 14 RT departments. Thirty patients (73.2 %) received postsurgical RT because of primary incomplete resection, 11 patients (26.8 %) as an adjunct after complete resections of recurrences or unclear resection status. The total doses ranged from 30 to 50 Gy (median, 36 Gy), the median single dose was 2.0 Gy. Local control was achieved 95.1%, and 82.9% had no or only slight functional impairment. The early and late toxicity was mild ({<=}RTOG Grade II). Conclusions: Radiation therapy is a safe and effective treatment for PVNS in the postoperative setting after incomplete resection, and also as a salvage option for treatment of recurrences it provides a high rate of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of High-Dose-Rate Interstitial Brachytherapy in the Treatment of Locally Advanced Cervical Cancer: Long-term Results

Purpose: The purpose of this study was to determine locoregional control (LRC), disease-free survival (DFS), and toxicity of high-dose-rate interstitial brachytherapy (HDR-ISBT) in the treatment of locally advanced cervical cancer. Methods and Materials: Between March 1996 and May 2009, 116 patients with cervical cancer were treated. Of these, 106 (91%) patients had advanced disease (International Federation of Gynecology and Obstetrics stage IIB-IVA). Ten patients had stage IB, 48 had stage II, 51 had stage III, and 7 had stage IVA disease. All patients were treated with a combination of external beam radiation therapy (EBRT) to the pelvis (5040 cGy) and 2 applications of HDR-ISBT to a dose of 3600 cGy to the implanted volume. Sixty-one percent of patients also received interstitial hyperthermia, and 94 (81%) patients received chemotherapy. Results: Clinical LRC was achieved in 99 (85.3%) patients. Three-year DFS rates were 59%, 67%, 71%, and 57% for patients with stage IB, II, III, and IVA disease, respectively. The 5-year DFS and overall survival rates for the entire group were 60% and 44%, respectively. Acute and late toxicities were within acceptable limits. Conclusions: Locally advanced cervical cancer patients for whom intracavitary BT is unsuitable can achieve excellent LRC and OS with a combination of EBRT and HDR-ISBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Controlled differential pressure system for an enhanced fluid blending apparatus

A system and method for producing a controlled blend of two or more fluids. Thermally-induced permeation through a permeable tube is used to mix a first fluid from outside the tube with a second fluid flowing through the tube. Mixture ratios may be controlled by adjusting the temperature of the first fluid or by adjusting the pressure drop through the permeable tube. The combination of a back pressure control valve and a differential regulator is used to control the output pressure of the blended fluid. The combination of the back pressure control valve and differential regulator provides superior flow control of the second dry gas. A valve manifold system may be used to mix multiple fluids, and to adjust the volume of blended fluid produced, and to further modify the mixture ratio.

47 OTHER INSTRUMENTATION↗

Predictors of Local Control After Single-Dose Stereotactic Image-Guided Intensity-Modulated Radiotherapy for Extracranial Metastases

Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy), intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergence of the temperature–density relation in the low-density intergalactic medium

We examine the evolution of the phase diagram of the low-density intergalactic medium during the Epoch of Reionization in simulation boxes with varying reionization histories from the Cosmic Reionization on Computers project. The probability density function (PDF) of gas temperature at fixed density exhibits two clear modes: a warm and a cold temperature mode, corresponding to the gas inside and outside of ionized bubbles. We find that the transition between the two modes is ‘universal’ in the sense that its timing is accurately parametrized by the value of the volume-weighted neutral fraction for any reionization history. This ‘universality’ is more complex than just a reflection of the fact that ionized gas is warm and neutral gas is cold: it holds for the transition at a fixed value of gas density, and gas at different densities transitions from the cold to the warm mode at different values of the neutral fraction, reflecting a non-trivial relationship between the ionization history and the evolving gas density PDF. Furthermore, the ‘emergence’ of the tight temperature–density relation in the warm mode is also approximately ‘universally’ controlled by the volume-weighted neutral fraction for any reionization history. In particular, the ‘emergence’ of the temperature–density relation (as quantified by the rapid decrease in its width) occurs when the neutral fraction is 10 –4 ≲ X HI ≲ 10 –3 for any reionization history. Our results indicate that the neutral fraction is a primary quantity controlling the various properties of the temperature–density relation, regardless of reionization history.

79 ASTRONOMY AND ASTROPHYSICS↗

Reproducibility of Intratumor Distribution of {sup 18}F-Fluoromisonidazole in Head and Neck Cancer

Purpose: Hypoxia is one of the main causes of the failure to achieve local control using radiotherapy. This is due to the increased radioresistance of hypoxic cells. {sup 18}F-fluoromisonidazole ({sup 18}F-FMISO) positron emission tomography (PET) is a noninvasive imaging technique that can assist in the identification of intratumor regions of hypoxia. The aim of this study was to evaluate the reproducibility of {sup 18}F-FMISO intratumor distribution using two pretreatment PET scans. Methods and Materials: We enrolled 20 head and neck cancer patients in this study. Of these, 6 were excluded from the analysis for technical reasons. All patients underwent an {sup 18}F-fluorodeoxyglucose study, followed by two {sup 18}F-FMISO studies 3 days apart. The hypoxic volumes were delineated according to a tumor/blood ratio {>=}1.2. The {sup 18}F-FMISO tracer distributions from the two {sup 18}F-FMISO studies were co-registered on a voxel-by-voxel basis using the computed tomography images from the PET/computed tomography examinations. A correlation between the {sup 18}F-FMISO intensities of the corresponding spatial voxels was derived. Results: A voxel-by-voxel analysis of the {sup 18}F-FMISO distributions in the entire tumor volume showed a strong correlation in 71% of the patients. Restraining the correlation to putatively hypoxic zones reduced the number of patients exhibiting a strong correlation to 46%. Conclusion: Variability in spatial uptake can occur between repeat {sup 18}F-FMISO PET scans in patients with head and neck cancer. Blood data for one patient was not available. Of 13 patients, 6 had well-correlated intratumor distributions of {sup 18}F-FMISO-suggestive of chronic hypoxia. More work is required to identify the underlying causes of changes in intratumor distribution before single-time-point {sup 18}F-FMISO PET images can be used as the basis of hypoxia-targeting intensity-modulated radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizations of silver alloys used in modern Mexican coins

This paper presents a complete methodology for the characterization of silver alloys used in modern coin production. Mexican coins with a nominal silver concentration from 10% to 99.99% were used in this study. Calibrated Glow Discharge Optical Emission Spectrometers were used to determine the chemical composition of the alloys as a function of the depth, while inductively coupled plasma was used to determine the total element composition in bulk. Scanning Electron Microscope was used to study the phase distributions in the different silver coins. According to Glow Discharge Optical Emission Spectrometers and inductively coupled plasma, the silver content found in the studied samples was consistently greater than that of the nominal silver content reported by the Mexican mint. This may lead to a review of the new methods of analysis used nowadays in contemporary coin minting. This result is very important because silver is increasing in value as metal and, considering the volume of production of silver coins, this may increase further as a consequence of a growing popular confidence in silver currency. In the case of silver studies, an advantage of the absence of silver detector in the Glow Discharge Optical Emission Spectrometers system is that it allows for the recalibration to have a better range of detection of other metals present in the alloys. A calibration curve using the copper content obtained by inductively coupled plasma (bulk) and Glow Discharge Optical Emission Spectrometers (depth profile) was performed. The relevance of control in modern silver coin minting was clarified, especially in minimizing the discrepancy between the nominal and the core fineness. The physical and chemical properties of the alloys studied are defined, revealing important variations in silver and copper contents. A new methodology and metrology for the control of coinage are suggested.

36 MATERIALS SCIENCE↗

Radiation Therapy for Cutaneous Squamous Cell Carcinoma Involving the Parotid Area Lymph Nodes: Dose and Volume Considerations

Purpose: The intraparotid and periparotid lymph nodes are the most commonly involved when skin cancer of the head and neck metastasizes beyond the primary site. We sought to report the clinical outcome of patients treated with radiation therapy for parotid-area metastases from cutaneous squamous cell carcinoma of the head and neck. Methods and Materials: The records of 36 patients treated with radiation therapy for cutaneous squamous cell carcinoma involving the parotid-area lymph nodes were reviewed. All patients had clinically N0 necks and were without evidence of distant disease. Thirty patients (83%) were treated postoperatively after gross total tumor resection. Median dose to the parotid area was 60 Gy (range, 50-72 Gy). Treatment of clinically N0 necks consisted of surgical dissection (7 patients), irradiation (15 patients), and observation (14 patients). Results: The 5-year estimate of local (parotid) control was 86% in patients treated using surgery with postoperative therapy and 47% in patients treated using radiation therapy alone. Three of 4 patients with tumors that relapsed locally after surgery and postoperative radiation received a dose of less than 60 Gy. Elective neck irradiation decreased the incidence of subsequent nodal failures from 50% to 0% and significantly improved neck control (p < 0.001). The 5-year overall survival rate was 63%. Conclusions: Surgery followed by radiation therapy to doses of at least 60 Gy results in effective local control for patients with parotid area metastasis from cutaneous squamous cell carcinoma. Routine irradiation of the clinically N0 neck is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CAM-SE–CSLAM: Consistent Coupling of a Conservative Semi-Lagrangian Finite-Volume Method with Spectral Element Dynamics

An algorithm to consistently couple a conservative semi-Lagrangian finite-volume transport scheme with a spectral element (SE) dynamical core is presented. The semi-Lagrangian finite-volume scheme is the Conservative Semi-Lagrangian Multitracer (CSLAM), and the SE dynamical core is the National Center for Atmospheric Research (NCAR)’s Community Atmosphere Model–Spectral Elements (CAM-SE). The primary motivation for coupling CSLAM with CAM-SE is to accelerate tracer transport for multitracer applications. The coupling algorithm result is an inherently mass-conservative, shape-preserving, and consistent (for a constant mixing ratio, the CSLAM solution reduces to the SE solution for air mass) transport that is efficient and accurate. This is achieved by first deriving formulas for diagnosing SE airmass flux through the CSLAM control volume faces. Thereafter, the upstream Lagrangian CSLAM areas are iteratively perturbed to match the diagnosed SE airmass flux, resulting in an equivalent upstream Lagrangian grid that spans the sphere without gaps or overlaps (without using an expensive search algorithm). This new CSLAM algorithm is not specific to airmass fluxes provided by CAM-SE but applies to any airmass fluxes that satisfy the Lipshitz criterion and for which the Courant number is less than one.

Lauritzen, Peter Hjort↗