Efficient loading of reduced data ensembles produced at ORNL SNS/HFIR neutron time-of-flight facilities

We present algorithmic improvements to the loading operations of certain reduced data ensembles produced from neutron scattering experiments at Oak Ridge National Laboratory (ORNL) facilities. Ensembles from multiple measurements are required to cover a wide range of the phase space of a sample material of interest. They are stored using the standard NeXus schema on individual HDF5 files. This makes it a scalability challenge, as the number of experiments stored increases in a single ensemble file. The present work follows up on our previous efforts on data management algorithms, to address identified input output (I/O) bottlenecks in Mantid, an open-source data analysis framework used across several neutron science facilities around the world. We reuse an in-memory binary-tree metadata index that resembles data access patterns, to provide a scalable search and extraction mechanism. In addition, several memory operations are refactored and optimized for the current common use cases, ranging most frequently from 10 to 180, and up to 360 separate measurement configurations. Results from this work show consistent speed ups in wall-clock time on the Mantid LoadMD routine, ranging from 19% to 23% on average, on ORNL production computing systems. The latter depends on the complexity of the targeted instrument-specific data and the system I/O and compute variability for the shared computational resources available to users of ORNL’s Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) instruments. Nevertheless, we continue to highlight the need for more research to address reduction challenges as experimental data volumes, user time and processing costs increase.

Godoy, William↗

Detecting Peer-to-Peer Botnets in SCADA Systems

Supervisory Control and Data Acquisition (SCADA) systems monitor and control critical infrastructure such as the smart grid. As SCADA systems become increasingly interconnected and adopt more and more cyber-enabled components, the risks of cyber attacks become a major concern. Due to their decentralized organization, peer-to-peer (P2P) botnets are resilient to many existing takedown measures and can be exploited as an effective way to launch cyber attacks on SCADA systems. However, little work has been done to detect P2P botnets in SCADA systems, which carry traffic flows with characteristics significantly different from the Internet. In this paper, we design a P2P-botnet detection method for SCADA systems, leveraging built-in traffic monitoring capabilities of SCADA networking devices. The proposed method consists of two stages. In the first stage, we design a simple feature test to filter out non-P2P hosts, which significantly reduces the data volume for P2P-botnet identification. In the second stage, we jointly consider flow-based and connectivity-based features that effectively set apart bots from benign hosts. We propose to use unsupervised learning for P2P-botnet identification, which not only identifies known P2P botnets but also captures newly emerged ones. Our simulation results show that the proposed system achieves high detection rates with very few false positives. Furthermore, our evaluation shows that the proposed method can detect hosts running P2P SCADA applications that are infected by P2P bots.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Distributed Neural Representation for Reactive In Situ Visualization

Implicit neural representations (INRs) have emerged as a powerful tool for compressing large-scale volume data. This opens up new possibilities for in situ visualization. However, the efficient application of INRs to distributed data remains an underexplored area. Here, in this work, we develop a distributed volumetric neural representation and optimize it for in situ visualization. Our technique eliminates data exchanges between processes, achieving state-of-the-art compression speed, quality and ratios. Our technique also enables the implementation of an efficient strategy for caching large-scale simulation data in high temporal frequencies, further facilitating the use of reactive in situ visualization in a wider range of scientific problems. We integrate this system with the Ascent infrastructure and evaluate its performance and usability using real-world simulations.

Wu, Qi↗

CONRAD—A software framework for cone-beam imaging in radiology

Purpose: In the community of x-ray imaging, there is a multitude of tools and applications that are used in scientific practice. Many of these tools are proprietary and can only be used within a certain lab. Often the same algorithm is implemented multiple times by different groups in order to enable comparison. In an effort to tackle this problem, the authors created CONRAD, a software framework that provides many of the tools that are required to simulate basic processes in x-ray imaging and perform image reconstruction with consideration of nonlinear physical effects.Methods: CONRAD is a Java-based state-of-the-art software platform with extensive documentation. It is based on platform-independent technologies. Special libraries offer access to hardware acceleration such as OpenCL. There is an easy-to-use interface for parallel processing. The software package includes different simulation tools that are able to generate up to 4D projection and volume data and respective vector motion fields. Well known reconstruction algorithms such as FBP, DBP, and ART are included. All algorithms in the package are referenced to a scientific source.Results: A total of 13 different phantoms and 30 processing steps have already been integrated into the platform at the time of writing. The platform comprises 74.000 nonblank lines of code out of which 19% are used for documentation. The software package is available for download at http://conrad.stanford.edu. To demonstrate the use of the package, the authors reconstructed images from two different scanners, a table top system and a clinical C-arm system. Runtimes were evaluated using the RabbitCT platform and demonstrate state-of-the-art runtimes with 2.5 s for the 256 problem size and 12.4 s for the 512 problem size.Conclusions: As a common software framework, CONRAD enables the medical physics community to share algorithms and develop new ideas. In particular this offers new opportunities for scientific collaboration and quantitative performance comparison between the methods of different groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI

Purpose: To develop and evaluate a computerized semiautomatic segmentation method for accurate extraction of three-dimensional lesions from dynamic contrast-enhanced magnetic resonance images (DCE-MRIs) of the breast. Methods: The authors propose a new background distribution-based active contour model using level set (BDACMLS) to segment lesions in breast DCE-MRIs. The method starts with manual selection of a region of interest (ROI) that contains the entire lesion in a single slice where the lesion is enhanced. Then the lesion volume from the volume data of interest, which is captured automatically, is separated. The core idea of BDACMLS is a new signed pressure function which is based solely on the intensity distribution combined with pathophysiological basis. To compare the algorithm results, two experienced radiologists delineated all lesions jointly to obtain the ground truth. In addition, results generated by other different methods based on level set (LS) are also compared with the authors’ method. Finally, the performance of the proposed method is evaluated by several region-based metrics such as the overlap ratio. Results: Forty-two studies with 46 lesions that contain 29 benign and 17 malignant lesions are evaluated. The dataset includes various typical pathologies of the breast such as invasive ductal carcinoma, ductal carcinomain situ, scar carcinoma, phyllodes tumor, breast cysts, fibroadenoma, etc. The overlap ratio for BDACMLS with respect to manual segmentation is 79.55% ± 12.60% (mean ± s.d.). Conclusions: A new active contour model method has been developed and shown to successfully segment breast DCE-MRI three-dimensional lesions. The results from this model correspond more closely to manual segmentation, solve the weak-edge-passed problem, and improve the robustness in segmenting different lesions.

60 APPLIED LIFE SCIENCES↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗

Gradient maintenance: A new algorithm for fast online replanning

Purpose: Clinical use of online adaptive replanning has been hampered by the unpractically long time required to delineate volumes based on the image of the day. The authors propose a new replanning algorithm, named gradient maintenance (GM), which does not require the delineation of organs at risk (OARs), and can enhance automation, drastically reducing planning time and improving consistency and throughput of online replanning. Methods: The proposed GM algorithm is based on the hypothesis that if the dose gradient toward each OAR in daily anatomy can be maintained the same as that in the original plan, the intended plan quality of the original plan would be preserved in the adaptive plan. The algorithm requires a series of partial concentric rings (PCRs) to be automatically generated around the target toward each OAR on the planning and the daily images. The PCRs are used in the daily optimization objective function. The PCR dose constraints are generated with dose–volume data extracted from the original plan. To demonstrate this idea, GM plans generated using daily images acquired using an in-room CT were compared to regular optimization and image guided radiation therapy repositioning plans for representative prostate and pancreatic cancer cases. Results: The adaptive replanning using the GM algorithm, requiring only the target contour from the CT of the day, can be completed within 5 min without using high-power hardware. The obtained adaptive plans were almost as good as the regular optimization plans and were better than the repositioning plans for the cases studied. Conclusions: The newly proposed GM replanning algorithm, requiring only target delineation, not full delineation of OARs, substantially increased planning speed for online adaptive replanning. The preliminary results indicate that the GM algorithm may be a solution to improve the ability for automation and may be especially suitable for sites with small-to-medium size targets surrounded by several critical structures.

60 APPLIED LIFE SCIENCES↗

SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Machine learning-based analysis of COVID-19 pandemic impact on US research networks

Here in this study we explore how fallout from the changing public health policy around COVID-19 has changed how researchers access and process their science experiments. Using a combination of techniques from statistical analysis and machine learning, we conduct a retrospective analysis of historical network data for a period around the stay-at-home orders that took place in March 2020. Our analysis takes data from the entire ESnet infrastructure to explore DOE high-performance computing (HPC) resources at OLCF, ALCF, and NERSC, as well as User sites such as PNNL and JLAB. We look at detecting and quantifying changes in site activity using a combination of t-Distributed Stochastic Neighbor Embedding (t-SNE) and decision tree analysis. Our findings bring insights into the working patterns and impact on data volume movements, particularly during late-night hours and weekends.

97 MATHEMATICS AND COMPUTING↗

DLIO: A DATA-CENTRIC BENCHMARK FOR DEEP LEARNING APPLICATIONS

SF-22-136 Deep learning has been shown as a successful method for various tasks, and its popularity results in numerous open-source deep learning software tools. Deep learning has been applied to a broad spectrum of scientific domains such as cosmology, particle physics, computer vision, fusion, and astrophysics. Scientists have performed a great deal of work to optimize the computational performance of deep learning frameworks. However, the same cannot be said for I/O performance. As deep learning algorithms rely on big-data volume and variety to effectively train neural networks accurately, I/O is a significant bottleneck on large-scale distributed deep learning training. DLIO, is a novel representative benchmark suite built based on the I/O profiling of the selected workloads. DLIO can be utilized to accurately emulate the I/O behavior of modern deep learning applications. Using DLIO, application developers and system software solution architects can identify potential I/O bottlenecks in their applications and guide optimizations to boost the I/O performance leading to lower training times. The storage vendor can also use DLIO as a guide for designing and optimize the storage and filesystem targeting at deep learning application.

ZHENG, HUIHUO↗

jeanloz_method

A simple Jupyter notebook program for fitting isothermal compression curves to pressure-versus-volume data.

Brennan, Matthew↗

3D Gaussian Splatting for Volume Compression

This codebase uses machine learning to train a collection of 3D Gaussian distributions to approximate scientific volume data. Because this collection uses less memory than the original dataset, it can be used as a compressed model of the original data for applications such as visualization.

Dyken, Landon↗

Aerosol-Cloud-Meteorology Interaction Airborne Field Investigations: Using Lessons Learned from the US West Coast in the Design of ACTIVATE off the US East Coast

We report on a multi-year set of airborne field campaigns (2005 – 2016) off the California coast to examine aerosols, clouds, and meteorology, and how lessons learned tie into the upcoming NASA Earth Venture Suborbital (EVS-3) campaign: Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment (ACTIVATE) (2019–2023). The largest uncertainty in estimating global anthropogenic radiative forcing is associated with the interactions of aerosol particles with clouds, which stems from the variability of cloud systems and the multiple feedbacks that affect and hamper efforts to ascribe changes in cloud properties to aerosol perturbations. While past campaigns have been limited in flight hours and the ability to fly in and around clouds, efforts sponsored by the Office of Naval Research have resulted in 113 single aircraft flights (> 500 flight hours) in a fixed region with warm marine boundary layer clouds. All flights used nearly the same payload of instruments on a Twin Otter to fly below, in, and above clouds, producing an unprecedented dataset. We provide here (i) an overview of statistics of aerosol, cloud, and meteorological conditions encountered in those campaigns and (ii) quantification of model-relevant metrics associated with aerosol-cloud interactions leveraging the high data volume and statistics. Based on lessons learned from those flights, we describe the pragmatic innovation in sampling strategy (dual aircraft approach with combined in situ and remote sensing) that will be used in ACTIVATE to generate a dataset that can advance scientific understanding and improve physical parameterizations for Earth system and weather forecasting models, and for assessing next-generation remote sensing retrieval algorithms.

54 ENVIRONMENTAL SCIENCES↗

Parallel ptychographic reconstruction

Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.

97 MATHEMATICS AND COMPUTING↗

Content-aware foveated camera for multi-target tracking

Modern image sensors deliver substantial space-time bandwidth, yet indiscriminate acquisition often overwhelms memory, computation, and downstream perception. We present a content-aware, multi-foveated camera that dynamically reallocates sensing and magnification to multiple regions of interest (ROIs). A phase-only spatial light modulator (SLM) serves as a solid-state, inertia-free beam-steering and lens element, enabling per-frame field-of-view (FOV) reconfiguration and content-aware target tracking. By interleaving frames across foveae, our system preserves a wide-FOV situational context while refreshing each ROI at high rates, thereby reducing data volume without degrading task performance. We constructed a prototype employing a single-SLM, single-sensor architecture and demonstrated its application in real-time multi-object tracking with dynamic ROI maintenance across multiple viewpoints. The approach offers a general pathway to integrate detection, tracking, and segmentation algorithms in the acquisition loop, shifting workload from post hoc processing to intelligent capture.

Zang, Zihan [Univ. of California, Los Angeles, CA ↗

Single-crystal X-ray diffraction of fluorapatite to 61 GPa

Apatite is a mineral of widespread importance in Earth and planetary science. Here we examine the behavior of a natural fluorapatite (FAp) crystal from Durango (Mexico) under compression to 61 GPa. Single-crystal X-ray diffraction experiments were carried out in a diamond-anvil cell using a synchrotron source. The apatite structure persists up to 32.4 GPa. Birch-Murnaghan equation of state parameters were fit to the pressure-volume data for fluorapatite for two cases: fixing V 0 at its measured ambient value resulted in a bulk modulus, K 0T , of 97.0(8) GPa and a pressure derivative of the bulk modulus, K' 0T , of 3.3(1), while fixing V 0 and K 0T at its ambient value 90.5 GPa (derived from ultrasonically measured elastic constants) resulted in a K' 0T value of 4.1(1). At 35.6 GPa, fluorapatite transforms to a triclinic phase (P$\bar{1}$, Z = 4), designated here as fluorapatite II (FAp-II). This phase persists up to at least 61 GPa. The major structural differences between FAp and FAp-II involve the buckling of the Ca polyhedra along the c-axis and changes in the number and coordination of the Ca sites. Furthermore, our study extends the pressure range over which fluorapatite has been examined by more than a factor of three, providing new insights into its structural response to high-pressure conditions.