Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Alternatives to Helium-3 for Neutron Multiplicity Counters

Multiplicity counters are an example of a neutron detection system affected by the shortage of 3He. Efforts are underway to identify potential 3He neutron detector replacements for use in multiplicity counters. Boron-10 and 6Li based systems are two of the options being explored as near-term 3He alternatives for neutron multiplicity counters. Simulations of BF3, 10B-lined proportional counters and 6Li/ZnS(Ag) sheets in various configurations have been performed with the Monte Carlo particle transport code MCNPX and compared to simulations of existing 3He counters. The system performances are being compared using figure of merits that are the square or cube of the total system efficiency divided by the die-away time. Design considerations include developing a system with enough neutron detection material to achieve the highest possible efficiency, while simultaneously minimizing system size. Adequate moderation is required to thermalize the incident neutrons for increased counting efficiency but as the system size increases so will the die-away time (average lifetime of neutrons in the counter). The optimal moderator configuration is one for which the increase in neutron detection efficiency is not defeated by an increase in die-away time. Thus, the entire system performance must be evaluated with every configuration change. The simulation results will be validated against a bench-top demonstrator unit design based on the system identified through simulations as having the highest performance potential. Presented here are the simulation results with various configurations of BF3 filled proportional counters, 10B lined proportional counters and 6Li/ZnS(Ag) sheets, and preliminary bench-top measurements.

Alternatives to Helium-3 for Neutron Multiplicity ↗

Assessment of a 1-D, Multi-colour X-ray Imaging System for the MAST ST

A design of the ID soft x-ray imaging system for future experiments at the Mega-Amper Spherical Tokamak (MAST) and results of the numerical simulations based on initial assumptions about the state of the tokamak plasma as well as the parameters and geometry of the detection system are presented. The imaging system consists of a set of arrays of detectors, pinholes and filters attached to each set, together with suitable readout electronics. In simulations, an array of semiconductor detectors is compared with an array of scintillator-photomultiplier combination. The measuring system is assumed to operate in the range 1-10 keV. In addition to the 1-D imaging of x-ray emission, the system gives the possibility to measure the energy slope of x-ray spectrum and thus the electron temperature of plasma.An extended numerical code simulates the imaging system for various parameters of plasma (spatial profiles of the plasma density and temperature) generated at the tokamak and for different configurations of the detection system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time system for imaging and object detection with a multistatic GPR array

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

47 OTHER INSTRUMENTATION↗

Neutrino Hunting: Looking through a UV Lens Scintillation Photon Detection in a Large-Volume Liquid Argon Time Projection Chamber, Exposed to a Multi-GeV Charged Particle Beam

The Deep Underground Neutrino Experiment (DUNE) will be a world-class neutrino observatory and nucleon decay detector designed to answer fundamental questions about elementary particles and their role in the universe. The DUNE experiment will consist of a a Near Detector, located at Fermilab, and a Far Detector, approximately 1.5~km underground at the Sanford Underground Research Facility in South Dakota, located $\sim$1300~km away. The accelerator complex at Fermilab will host an intense beam of neutrinos directed toward the two detectors. My dissertation centers on the implementation of technologies used to detect scintillation photon signals in liquid argon in the context of the DUNE's Far Detector Single-Phase (SP) module design, and features direct contributions to the Photon Detection System (PDS) deployed in the ProtoDUNE-SP Large-Volume Liquid Argon Time Projection Chamber (LArTPC) prototype. The PDS is needed for non-beam event timing, such as atmospheric neutrinos, proton d ecay, and supernova detection. The PDS provides a prompt signal ($t_{0}$ information) for micro-second event time determination, which improves the TPC's spatial localization along drift direction, enables accurate ionization-signal-attenuation determination, and even provides calorimetry. My dissertation will discuss an overview of the DUNE and ProtoDUNE-SP experiment and how we detect neutrinos in LAr, via charge and scintillation light. It will discuss my core experimental and analysis work, in regards to the Photon Detection System; including my contributions in establishing procedures for the commissioning and integration for the Photon Detector System that will be valuable during the construction, installation, commissioning, and operations of the DUNE Far Detector. In addition, it will comprehensively discuss the capability of three different photon detection technologies, and their characteristics and responses to muon and electron beam particles over a range of beam momenta , from 0.3~GeV/$c$ - 7~GeV/$c$. Further, the overall progress detailed in this thesis will help pave the way toward understanding the physical properties of these detectors, which will contribute to the success of the sensitivity measurements required for determining the neutrino mass hierarchy and $\delta_{CP}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of ordinary-mode reflectometry system to detect lower-hybrid waves in Alcator C-Mod

Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closed flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Physics of Compact Binaries with GADGET

The research goal of this project was to experimentally constrain the thermonuclear rate of the 15 O(α, Υ) 19 Ne reaction, whose uncertainty has a strong influence on the modeling of astrophysical Type-I X-ray bursts on accreting neutron stars. To this end, Experiment 21072 was run in November 2022 at the Facility for Rare Isotope Beams using the GADGET II detection system. The limited scope and duration of this award included work in the year following the experiment: drafting a technical paper on the time projection chamber of the GADGET II detection system, and analysis of data from Experiment 21072. The award contributed to the education and development of the scientific and technical workforce by partially supporting one postdoctoral Research Associate who did this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On Anomaly Detection for Transactive Energy Systems with Competitive Market

Two anomaly-detection criteria are proposed for transactive energy systems with competitive markets. Participants of transactive energy systems seek an optimal power allocation through hybrid economic-control methods to facilitate the integration of various types of distributed energy resources to power distribution systems. In transactive energy systems, every participant is assumed to be a rational entity, and consumers have diminishing marginal utility and suppliers have increasing marginal cost. With the first proposed anomaly-detection criterion, the monotonicity of marginal cost and marginal utility are examined. The impact of line flow constraints is also taken into consideration. Then, the second anomaly-detection criterion is proposed for TESs with marginal cost and marginal utility which change faster than a certain rate. The second criterion is more accurate than the first one for TES with marginal cost and marginal utility which change faster than a certain rate, but it requires the knowledge of that rate. Neither criteria requires more data than those necessary to find the optimal power allocation and the market-clear price in a transactive energy system. Therefore, the proposed criteria do not disclose any more data than necessary. As the monotonicity of marginal cost and marginal utility in a TES with competitive markets results in convex objective functions in an optimization problem and strongly convex ones when marginal cost and marginal utility changes faster than a certain rate, the two detection criteria are also applicable to anomaly detection of general convex optimization problems. Simulations are carried out to show the efficacy of the proposed criteria to detect anomalies caused by cyberattacks.

Wang, Peng↗

Deadtime Determination of Helium Detector Using MCNP Code

In detector systems, the minimum time separation between the events is called detector's deadtime. The The intrinsic properties of the detector and the pulse processing circuitry's characteristics are the sources of deadtime. Researchers have been working on improving a detector deadtime model that can implicitly characterize a detection system's behavior while reducing counting errors. There are two commonly known dead-time models: the 'Paralyzing' and the 'Non-paralyzing' models. In reality, detection systems fit neither of these idealized models perfectly, instead falling somewhere between the two models. The paralyzing model is mathematically expressed by eq. 1, where m is the measured count rate, n is the true count rate and t is dead-time. This model assumes that each event during the dead-time will reset it to a fixed duration, thus extending the deadtime. The dead-time extension depends on the count rate. According to the non-paralyzing model, deadtime is fixed after each detected event, and all events occurring during deadtime are lost. The fraction of time during which an apparatus is sensitive is 1-mt. Therefore, the fraction of the true number of events can be recorded. In this study, a Canberra {sup 3}He neutron detector (0.5NH1/1K) deadtime value was estimated using a combination of experimental subcritical assembly measurements and theoretical MCNP simulations. The deadtime of the Canberra 10 mm diameter {sup 3}He tube detector was calculated by comparing measured counts from different locations in the subcritical assembly at Missouri University of Science and Technology Reactor (MSTR) with MCNP (Monte Carlo N-Particle Code) simulations. The deadtime calculations are provided for both the paralyzing and non-paralyzing models for the Canberra 10 mm diameter {sup 3}He tube detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airborne Particulate Threat Assessment

Aerosol threat detection requires the ability to discern between threat agents and ambient background particulate matter (PM) encountered in the environment. To date, Raman imaging technology has been demonstrated as an effective strategy for the assessment of threat agents in the presence of specific, complex backgrounds. Expanding our understanding of the composition of ambient particulate matter background will improve the overall performance of Raman Chemical Imaging (RCI) detection strategies for the autonomous detection of airborne chemical and biological hazards. Improving RCI detection performance is strategic due to its potential to become a widely exploited detection approach by several U.S. government agencies. To improve the understanding of the ambient PM background with subsequent improvement in Raman threat detection capability, ChemImage undertook the Airborne Particulate Threat Assessment (APTA) Project in 2005-2008 through a collaborative effort with the National Energy Technology Laboratory (NETL), under cooperative agreement number DE-FC26-05NT42594. During Phase 1 of the program, a novel PM classification based on molecular composition was developed based on a comprehensive review of the scientific literature. In addition, testing protocols were developed for ambient PM characterization. A signature database was developed based on a variety of microanalytical techniques, including scanning electron microscopy, FT-IR microspectroscopy, optical microscopy, fluorescence and Raman chemical imaging techniques. An automated particle integrated collector and detector (APICD) prototype was developed for automated collection, deposition and detection of biothreat agents in background PM. During Phase 2 of the program, ChemImage continued to refine the understanding of ambient background composition. Additionally, ChemImage enhanced the APICD to provide improved autonomy, sensitivity and specificity. Deliverables included a Final Report detailing our findings and APICD Gen II subsystems for automated collection, deposition and detection of ambient particulate matter. Key findings from the APTA Program include: Ambient biological PM taxonomy; Demonstration of key subsystems needed for autonomous bioaerosol detection; System design; Efficient electrostatic collection; Automated bioagent recognition; Raman analysis performance validating Td<9 sec; Efficient collection surface regeneration; and Development of a quantitative bioaerosol defection model. The objective of the APTA program was to advance the state of our knowledge of ambient background PM composition. Operation of an automated aerosol detection system was enhanced by a more accurate assessment of background variability, especially for sensitive and specific sensing strategies like Raman detection that are background-limited in performance. Based on this improved knowledge of background, the overall threat detection performance of Raman sensors was improved.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Commissioning of the BRIKEN detector for the measurement of very exotic β -delayed neutron emitters

A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and -ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and β-delayed neutron emission probabilities. Here, the methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space Radiation Shielding Studies for Astronaut and Electronic Component Risk Assessment

The dosimetry component of the Center for Radiation Engineering and Science for Space Exploration (CRESSE) will design, develop and characterize the response of a suite of radiation detectors and supporting instrumentation and electronics with three primary goals that will: (1) Use established space radiation detection systems to characterize the primary and secondary radiation fields existing in the experimental test-bed zones during exposures at particle accelerator facilities. (2) Characterize the responses of newly developed space radiation detection systems in the experimental test-bed zones during exposures at particle accelerator facilities, and (3) Provide CRESSE collaborators with detailed dosimetry information in experimental test-bed zones.

Fuchs, Jordan Robert↗

On the pilot's behavior of detecting a system parameter change

The reaction of a human pilot, engaged in compensatory control, to a sudden change in the controlled element's characteristics is described. Taking the case where the change manifests itself as a variance change of the monitored signal, it is shown that the detection time, defined to be the time elapsed until the pilot detects the change, is related to the monitored signal and its derivative. Then, the detection behavior is modeled by an optimal controller, an optimal estimator, and a variance-ratio test mechanism that is performed for the monitored signal and its derivative. Results of a digital simulation show that the pilot's detection behavior can be well represented by the model proposed here.

Morizumi, N.↗

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of velocity/trajectory measurement technologies during a particle capture event

Since the early 1960s, the means to measure the time of flight (TOF) of dust grain within a mechanical detection array has existed, first in the laboratory and then in space experiments. Laboratory hypervelocity dust particle accelerators have used electrostatic detection of charge on accelerated particles for TOF and particle mass detections. These laboratory studies have led to the development of ultra-thin-film sensors that have been used for TOF measurements in dust particle space experiments. The prototypes for such devices were ultra-thin-film capacitors that were used in the OGO series of satellites. The main goal of the experimental work to be described is the development of the capability to determine the velocity vector or trajectory of a dust grain traversing an integrated dust detection array. The results of these studies have shown that the capability of detecting the charge liberated by hypervelocity dust grains with diameters in the micrometer range can be detected. Based on these results, detection systems have been designed to provide a precise analysis of the physical and dynamic properties of micrometer and submicrometer dust grains, namely the design verification unit (DVU). Through unique combinations of in situ detection systems, direct measurements of particle surface charge, velocity, momentum, kinetic energy, and trajectory have been achieved. From these measurements, the remaining physical parameters of mass, size, and density can be determined.

Tanner, William G.↗

A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume

A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.

Ajmani, Kumud↗

Performance of Europium-Doped Strontium Iodide, Transparent Ceramics and Bismuth-loaded Polymer Scintillators

Recently discovered scintillators for gamma ray spectroscopy, single crystal SrI{sub 2}(Eu), GYGAG(Ce) transparent ceramic and Bismuth-loaded plastics, offer resolution and fabrication advantages compared to commercial scintillators, such as NaI(Tl) and standard PVT plastic. Energy resolution at 662 keV of 2.7% is obtained with SrI{sub 2}(Eu), while 4.5% is obtained with GYGAG(Ce). A new transparent ceramic scintillator for radiographic imaging systems, GLO(Eu) offers high light yield of 70,000 Photons/MeV, high stopping, and low radiation damage. Implementation of single crystal SrI{sub 2}(Eu), Gd-based transparent ceramics, and Bi-loaded plastic scintillators can advance the state-of-the art in ionizing radiation detection systems.

36 MATERIALS SCIENCE↗