Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Investigation of Relevant Distribution System Representation With DG for Voltage Stability Margin Assessment

This paper emphasizes the importance of including unbalanced distribution systems for voltage stability studies in power systems. The paper aims to: discuss the various simulation methods for power system analysis; highlight the need for modeling unbalanced distribution system for accurate load margin assessment; demonstrate the influence of net-load unbalance (NLU) on voltage stability margin (VSM). We also share a T&D co-simulation interface with commercial power system solvers. The distribution system is evolving rapidly with high proliferation of distributed energy resources (DERs); these are not guaranteed to proliferate in a balanced manner and uncertainty resulting due to these DERs is well acknowledged. These uncertainties cannot be captured or visualized without representing the distribution system in detail along with the transmission system. We show the impact of proliferation of DERs in various 3-phase proportions on voltage stability margin through T&D co-simulation. We also study the impact of volt/VAR control on voltage stability margin. This analysis is only possible by representing the distribution system in detail through T&D co-simulation. In conclusion, higher percentage of net-load unbalance (NLU) in distribution system aggravates the voltage stability margin of the distribution system, which can further negatively influence the overall voltage stability margin of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Hierarchical, Grid-Aware, and Economically Optimal Coordination of Distributed Energy Resources in Realistic Distribution Systems

Renewable portfolio standards are targeting high levels of variable solar photovoltaics (PV) in electric distribution systems, which makes reliability more challenging to maintain for distribution system operators (DSOs). Distributed energy resources (DERs), including smart, connected appliances and PV inverters, represent responsive grid resources that can provide flexibility to support the DSO in actively managing their networks to facilitate reliability under extreme levels of solar PV. This flexibility can also be used to optimize system operations with respect to economic signals from wholesale energy and ancillary service markets. Here, we present a novel hierarchical scheme that actively controls behind-the-meter DERs to reliably manage each unbalanced distribution feeder and exploits the available flexibility to ensure reliable operation and economically optimizes the entire distribution network. Each layer of the scheme employs advanced optimization methods at different timescales to ensure that the system operates within both grid and device limits. The hierarchy is validated in a large-scale realistic simulation based on data from the industry. Simulation results show that coordination of flexibility improves both system reliability and economics, and enables greater penetration of solar PV. Discussion is also provided on the practical viability of the required communications and controls to implement the presented scheme within a large DSO.

distribution network↗

Distributed Detection of Malicious Attacks on Consensus Algorithms with Applications in Power Networks

Consensus-based distributed algorithms are well suited for coordination among agents in a cyber-physical system. These distributed schemes, however, suffer from their vulnerability to cyber attacks that are aimed at manipulating data and control ow. In this article, we present a novel distributed method for detecting the presence of such intrusions for a distributed multi-agent system following ratio consensus. We employ a Max-Min protocol to develop low cost, easy to implement detection strategies where each participating node detects the intrusion independently, eliminating the need for a trusted certifying agent in the network. The effectiveness of the detection method is demonstrated by numerical simulations on a 1000 node network to demonstrate the efficacy and simplicity of implementation.

27 ARPA - Advanced Research Projects Agency-Energy↗

Low-cost wireless voltage & current grid monitoring

This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

14 SOLAR ENERGY↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗

Power System Protection and Resilient Metrics

During a real-time power system event, a system operator need to conservatively reduce the operating limits while changing system conditions are analyzed. The time it takes to develop new operating limits could affect millions of transmission system users especially if this event is classified by NERC as a Category D type event (extreme events resulting in the loss of two or more bulk electric system elements) . Controls for the future grid must be able to perform real-time analysis, identify new reliability risks, and set new SOLs (System Operating Limit) for real-time operations. In this paper we are inducing “Resilience Metrics” requirements that describe how systems operate at an acceptable level of normalcy despite disturbances or threats. We consider the interdependencies inherent in critical infrastructure systems and discuss some resilience metrics that can be distributed in current supervisory control and data acquisition (SCADA) to provide a level of state awareness. This level of awareness provides knowledge that can be used to characterize and reduce the risk of cascading events. A “resilience power system agent” is proposed that provides attributes to measure and perform this metrics.

42 ENGINEERING↗

Mars, the Moon, and the Ends of the Earth: Autonomy for Small Reactor Power Systems

In recent years, the National Aeronautics and Space Administration (NASA) has been considering deep space missions that utilize a small-reactor power system (SRPS) to provide energy for propulsion and spacecraft power. Additionally, application of SRPS modules as a planetary power source is being investigated to enable a continuous human presence for nonpolar lunar sites and on Mars. A SRPS can supply high-sustained power for space and surface applications that is both reliable and mass efficient. The use of small nuclear reactors for deep space or planetary missions presents some unique challenges regarding the operations and control of the power system. Current-generation terrestrial nuclear reactors employ varying degrees of human control and decision-making for operations and benefit from periodic human interaction for maintenance. In contrast, the control system of a SRPS employed for deep space missions must be able to accommodate unattended operations due to communications delays and periods of planetary occlusion while adapting to evolving or degraded conditions with no opportunity for repair or refurbishment. While surface power systems for planetary outposts face less extreme delays and periods of isolation and may benefit from limited maintenance capabilities, considerations such as human safety, resource limitations and usage priorities, and economics favor minimizing direct, continuous human interaction with the SRPS for online, dedicated power system management. Thus, a SRPS control system for space or planetary missions must provide capabilities for operational autonomy. For terrestrial reactors, large-scale power plants remain the preferred near-term option for nuclear power generation. However, the desire to reduce reliance on carbon-emitting power sources in developing countries may lead to increased consideration of SRPS modules for local power generation in remote regions that are characterized by emerging, less established infrastructures. Additionally, many Generation IV (Gen IV) reactor concepts have goals for optimizing investment recovery and economic efficiency that promote significant reductions in plant operations and maintenance staff over current-generation nuclear power plants. To accomplish these Gen IV goals and also address the SRPS remote-siting challenges, higher levels of automation, fault tolerance, and advanced diagnostic capabilities are needed to provide nearly autonomous operations with anticipatory maintenance. Essentially, the SRPS control system for several anticipated terrestrial applications can benefit from the kind of operational autonomy that is necessary for deep space and planetary SRPS-enabled missions. Investigation of the state of the technology for autonomous control confirmed that control systems with varying levels of autonomy have been employed in robotic, transportation, spacecraft, and manufacturing applications. As an example, NASA has pursued autonomy for spacecraft and surface exploration vehicles (e.g., rovers) to reduce mission costs, increase efficiency for communications between ground control and the vehicle, and enable independent operation of the vehicle during times of communications blackout. However, autonomous control has not been implemented for an operating terrestrial nuclear power plant nor has there been any experience beyond automating simple control loops for space reactors. Current automated control technologies for nuclear power plants are reasonably mature, and fully automated control of normal SRPS operations is clearly feasible. However, the space-based and remote terrestrial applications of SRPS modules require autonomous capabilities that can accommodate nonoptimum operations when degradation, failure, and other off-normal events challenge the performance of the reactor while immediate human intervention is not possible. The independent action provided by autonomous control, which is distinct from the more limited self action of automated control, can satisfy these conditions. Key characteristics that distinguish autonomous control include: (1) intelligence to confirm system performance and detect degraded or failed conditions, (2) optimization to minimize stress on SRPS components and efficiently react to operational events without compromising system integrity, (3) robustness to accommodate uncertainties and changing conditions, and (4) flexibility and adaptability to accommodate failures through reconfiguration among available control system elements or adjustment of control system strategies, algorithms, or parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Continuous flow photochemical synthesis of metal–ceramic composite microparticles

We developed a UV-assisted microfluidic system to synthesize FeCrAl–Al 2 O 3 composite microparticles for additive manufacturing. Here, the system ensures precise particle size, morphology, and elemental distribution control. Increasing the dispensing pressure while keeping the oil flow rate constant resulted in larger microparticles. Laser fusing revealed FeCrAl and Al 2 O 3 phases, showing their potential as feedstocks for 3D printed heterogeneous materials such as FeCrAl/Al 2 O 3 bi-phase materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale deformation mechanism of TiC/a-C nanocomposite thin films

This paper concentrates on the deformation behavior of amorphous diamondlike carbon composite materials. Combined nanoindentation and ex situ cross-sectional transmission electron microscopy investigations are carried out on TiC/a-C nanocomposite films, with and without multilayered structures deposited by pulse dc magnetron sputtering. It is shown that by controlling the distribution of nanocrystallites forming nanoscale multilayers, the system can be used as a 'microstructural ruler' that is able to distinguish various deformation patterns, which can be hardly detected otherwise in a homogeneous structure. It is shown that rearrangement of nanocrystallites and displacement of a-C matrix occur at length scales from tens of nanometer down to 1 nm. At submicrometer scale homogeneous nucleation of multiple shear bands has been observed within the nanocomposites. The multilayered structure in the TiC/a-C nanocomposite film contributes to an enhanced toughness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic ADMM for Real-Time Optimal Power Flow

This paper considers distribution networks featuring distributed energy resources (DERs), and develops a dynamic optimization method to maximize given operational objectives in real time while adhering to relevant network constraints. The design of the dynamic algorithm is based on suitable linearization of the AC power flow equations, and it leverages the so-called alternating direction method of multipliers (ADMM). The steps of the ADMM, however, are suitably modified to accommodate appropriate measurements from the distribution network and the DERs. With the aid of these measurements, the resultant algorithm can enforce given operational constraints in spite of inaccuracies in the representation of the AC power flows, and it avoids ubiquitous metering to gather the state of noncontrollable resources. Optimality and convergence of the proposed algorithm are established in terms of tracking of the solution of a convex surrogate of the AC optimal power flow problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Infrared vibrational nano-crystallography and nano-imaging

Molecular solids and polymers can form low-symmetry crystal structures that exhibit anisotropic electron and ion mobility in engineered devices or biological systems. The distribution of molecular orientation and disorder then controls the macroscopic material response, yet it is difficult to image with conventional techniques on the nanoscale. We demonstrated a new form of optical nanocrystallography that combines scattering-type scanning near-field optical microscopy with both optical antenna and tip-selective infrared vibrational spectroscopy. From the symmetry-selective probing of molecular bond orientation with nanometer spatial resolution, we determined crystalline phases and orientation in aggregates and films of the organic electronic material perylenetetracarboxylic dianhydride. Mapping disorder within and between individual nanoscale domains, the correlative hybrid imaging of nanoscale heterogeneity provides insight into defect formation and propagation during growth in functional molecular solids.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State Estimation-Based Distributed Energy Resource Optimization for Distribution Voltage Regulation in Telemetry-Sparse Environments Using a Real-Time Digital Twin

Real-time state estimation using a digital twin can overcome the lack of in-field measurements inside an electric feeder to optimize grid services provided by distributed energy resources (DERs). Optimal reactive power control of DERs can be used to mitigate distribution system voltage violations caused by increased penetrations of photovoltaic (PV) systems. In this work, a new technology called the Programmable Distribution Resource Open Management Optimization System (ProDROMOS) issued optimized DER reactive power setpoints based-on results from a particle swarm optimization (PSO) algorithm wrapped around OpenDSS time-series feeder simulations. This paper demonstrates the use of the ProDROMOS in a RT simulated environment using a power hardware-in-the-loop PV inverter and in a field demonstration, using a 678 kW PV system in Grafton (MA, USA). The primary contribution of the work is demonstrating a RT digital twin effectively provides state estimation pseudo-measurements that can be used to optimize DER operations for distribution voltage regulation.

Darbali-Zamora, Rachid↗

The Formation of Pb(IV) Oxides in Chlorinated Water

Recent research has shown that Pb(IV) oxides play a significant geochemical role in drinking water distribution systems. However, most of the guidance for lead control in drinking water is based on the presumption that Pb(II) solids control lead solubility. Therefore, a better understanding of the chemistry of Pb(IV) in water is needed. Long-term lead precipitation experiments were conducted in chlorinated water (1-3 mg/L Cl{sub 2}) at pH 6.5,8, and 10, with and without sulfate. Results showed that two Pb(IV) dioxide polymorphs-plattnerite ({beta}-PbO{sub 2}) and scrutinyite ({alpha}-PbO{sub 2})-formed over time, as long as a high suspension redox potential was maintained with free chlorine. Neither mineral formed spontaneously, and the rate of formation increased with increasing pH. Hydrocerrusite and/or cerrusite initially precipitated out and overtime either disappeared or coexisted with PbO{sub 2}. Water pH dictated mineralogical presence. High pH favored hydrocerrusite and scrutinyite; low pH favored cerrusite and plattnerite. Along with a transformation of Pb(II) to Pb(IV) came a change in particle color from white to a dark shade of red to dark grey (differing with pH) and a decrease in lead solubility. If free chlorine was permitted to dissipate, the aging processes (i.e., mineralogy, color, and solubility) were reversible.

54 ENVIRONMENTAL SCIENCES↗

A Line Weighted Frequency Droop Controller for Decentralized Enforcement of Transmission Line Power Flow Constraints in Inverter-Based Networks

Recent works have shown that networks of voltagesource inverters implementing frequency droop control may be analyzed as consensus-like networks. Based on this understanding, we show that enforcement of network line power flows can be viewed as an edge-preservation problem in a -disk dynamic interaction graph. Inspired by other works solving similar problems in other domains, we propose a line weighted frequency droop controller such that a network of all active buses implementing this controller enforces the specified line power flow constraints without need for communication. We provide simulation results verifying that our proposed controller limits line power to enforce constraints, and otherwise acts as a traditional droop controller.

Distributed control↗