Search NASA⌕ Search

SEARCH · Search NASA

Results for “double layer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Two‐Dimensional (2D) or Quasi‐2D Superstructures from DNA‐Coated Colloidal Particles

Abstract This contribution describes the synthesis of colloidal di‐patch particles functionalized with DNA on the patches and their assembly into colloidal superstructures via cooperative depletion and DNA‐mediated interactions. The assembly into flower‐like Kagome, brick‐wall like monolayer, orthogonal packed single or double layers, wrinkled monolayer, and colloidal honeycomb superstructures can be controlled by tuning the particles’ patch sizes and assembly conditions. Based on these experimental results, we generate an empirical phase diagram. The principles revealed by the phase diagram provide guidance in the design of two‐dimensional (2D) materials with desired superstructures. Our strategy might be translatable to the assembly of three‐dimensional (3D) colloidal structures.

Liu, Mingzhu↗

Probing the Effects of Acid Electrolyte Anions on Electrocatalyst Activity and Selectivity for the Oxygen Reduction Reaction

The local microenvironment at the electrode-electrolyte interface plays an important role in electrocatalytic performance. Herein, we investigate the effect of acid electrolyte anion identity on the oxygen reduction reaction (ORR) activity and selectivity of smooth Ag and Pd catalyst thin films. Cyclic voltammetry in perchloric, nitric, sulfuric, phosphoric, hydrochloric, and hydrobromic acid, at pH1, reveals that Ag ORR activity trends as follows: HClO 4 >HNO 3 >H 2 SO 4 >H 3 PO 4 >HCl>>HBr, while Pd ORR activity trends as: HClO 4 >H 2 SO 4 >HNO 3 >H 3 PO 4 >HCl>>HBr. Moreover, rotating-ring-disk-electrode selectivity measurements demonstrate enhanced 4 e - selectivity on both Ag and Pd, by up to 35% H 2 O 2 and 10% H 2 O 2 respectively, in HNO 3 compared to in HClO 4 . Relating physics-based modeling and experimental results, we postulate that ORR performance depends greatly on anion-related phenomena in the double layer, for instance competitive adsorption and non-covalent interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of Pertechnetate-Related Oxyanions from Solution Using Functionalized Hierarchical Porous Frameworks

Efficient and cost-effective removal of radioactive pertechnetate anions from nuclear waste is a key challenge to mitigate long-term nuclear waste storage issues. Traditional materials such as resins and layered double hydroxides (LDHs) were evaluated for their pertechnetate or perrhenate (the non-radioactive surrogate) removal capacity, but there is room for improvement in terms of capacity, selectivity and kinetics. A series of functionalized hierarchical porous frameworks were evaluated for their perrhenate removal capacity in the presence of other competing anions.

anion removal↗

Quantitative study of non-covalent interactions at the electrode-electrolyte interface using cyanide-modified Pt(111) electrodes.

Cations at the outer Helmholtz plane (OHP) can interact through non-covalent interactions with species at the inner Helmholtz plane (IHP), which are covalently bonded to the electrode surface, thereby affecting the structure and the properties of the electrochemical double layer. These non-covalent interactions can be studied quantitatively using cyanide-modified Pt(111) electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Simulation Results on Charged Carbon Nanotube Forest-Based Supercapacitors

In this paper, electrochemical double-layer capacitances of charged carbon nanotube (CNT) forests with tetraethyl ammonium tetrafluoro borate electrolyte in propylene carbonate are studied on the basis of molecular dynamics simulation. Direct molecular simulation of the filling of pore spaces of the forest is feasible even with realistic, small CNT spacings. The numerical solution of the Poisson equation based on the extracted average charge densities then yields a regular experimental dependence on the width of the pore spaces, in contrast to the anomalous pattern observed in experiments on other carbon materials and also in simulations on planar slot-like pores. The capacitances obtained have realistic magnitudes but are insensitive to electric potential differences between the electrodes in this model. This agrees with previous calculations on CNT forest supercapacitors, but not with experiments which have suggested electrochemical doping for these systems. Finally, those phenomena remain for further theory/modeling work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Operando Calorimetric Measurements for Activated Carbon Electrodes in Ionic Liquid Electrolytes under Large Potential Windows

This study aims to investigate the effect of the potential window on heat generation in carbon-based electrical double layer capacitors (EDLCs) with ionic-liquid (IL)-based electrolytes using in operando calorimetry. The EDLCs consisted of two identical activated-carbon electrodes with either neat 1-butyl-1-methylpyrrolidinium bis(trifluoromethane-sulfonyl)imide ([Pyr 14 ][TFSI]) electrolyte or 1.0 m [Pyr 14 ][TFSI] in propylene carbonate (PC) as electrolyte. The instantaneous heat generation rate at each electrode was measured under galvanostatic cycling for different potential windows ranging from 1 to 4 V. First, the heat generation rates at the positive and negative electrodes differed significantly in neat IL owing to the differences in the ion sizes and diffusion coefficients. However, these differences were minimized when the IL was diluted in PC. Second, for EDLC in neat [Pyr 14 ][TFSI] at high potential window (4 V), a pronounced endothermic peak was observed at the beginning of the charging step at the positive electrode owing to TFSI - intercalation in the activated carbon. On the other hand, for EDLC in 1.0 m [Pyr 14 ][TFSI] in PC at potential window above 3 V, an endothermic peak was observed only at the negative electrode owing to the decomposition of PC. Third, for both neat and diluted [Pyr 14 ][TFSI] electrolytes, the irreversible heat generation rate increased with increasing potential window and exceeded Joule heating. This was attributed to the effect of potential-dependent charge redistribution resistance. Additionally, a further increase in the irreversible heat generation rate was observed for the largest potential windows owing to the degradation of the PC solvent. Finally, for both types of electrolyte, the reversible heat generation rate increased with increasing potential window because of the increase in the amount of ion adsorbed/desorbed at the electrode/electrolyte interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling electrokinetics in ionic liquids: General

Using direct numerical simulations we provide a thorough study on the electrokinetics of ionic liquids. In particular, the modfied Poisson-Nernst-Planck (MPNP) equations are solved to capture the crowding and overscreening effects that are the characteristics of an ionic liquid. For modeling electrokinetic flows in an ionic liquid, the MPNP equations are coupled with the Navier-Stokes equations to study the coupling of ion transport, hydrodynamics, and electrostatic forces. Specifically, we consider the ion transport between two parallel plates, charging dynamics in a 2D straight-walled pore, electro-osmotic ow in a nano-channel, electroconvective instability on a plane ion-selective surface, and electroconvective ow on a curved ion-selective surface. We discuss how the crowding and overscreening effects and their interplay affect the electrokinetic behaviors of ionic liquids in these application problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of aqueous‐based cathode slurry pH and immersion time on corrosion of aluminum current collector in lithium‐ion batteries

Corrosion of aluminum can occur during the manufacturing of lithium‐ion batteries when using aqueous‐based cathode slurries. In exposure tests, the alkaline pH value of aqueous‐based cathode slurries and immersing time were revealed as the principle factors that control the corrosion of aluminum during the cathode manufacturing process. The nickel manganese cobalt oxide active material used in the slurry does not have a direct impact on corrosion of the aluminum current collector. The initiation and evolution of localized corrosion on aluminum are closely related to the formation of galvanic cells between aluminum matrix and intermetallic particles. X‐ray photoelectron spectroscopy results confirmed that the pH of cathode slurry was the only factor that alters aluminum surface composition, during which the oxide passive film was gradually degraded into hydroxide. Electrochemical characterizations showed that aluminum electrodes gave remarkably different response to the different pH of test solutions. The time‐pH‐variant electrochemical response was ascribed to the change of passive film and electric double layer properties.

Li, S. Y.↗

Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

Growth Dynamics and Electron Reflectivity in Ultrathin Films of Chiral Heptahelicene on Metal (100) Surfaces Studied by Spin-Polarized Low Energy Electron Microscopy

Interaction of electrons with chiral matter gives rise to interesting phenomena such as the chirality-induced spin selectivity. The interdependence of reflectivity of spin-polarized low energy electrons and the absolute handedness of chiral molecules is investigated. First, the growth of homochiral films of helical aromatic hydrocarbons, so-called helicenes, on a Cu(100) surface is studied by means of low energy electron microscopy and scanning tunneling microscopy in ultrahigh vacuum. As soon as the coverage exceeds one monolayer, double-layer nucleation and growth is favored such that depletion in the first layer occurs. Spatially resolved work function measurements show that second-layer patches have a lower work function than first-layer areas. Reflectivity spectra of spin-polarized electrons do not show any asymmetry between homochiral films of the enantiomers. Laterally resolved work function measurements do not confirm work function differences such as those reported earlier for photoelectron studies of chiral peptide films on ferromagnetic substrates.

36 MATERIALS SCIENCE↗

Permanently Magnetized Insulating Thin-Film Devices by Reduction

A reduction-based manufacturing process for creating technologically important multilayer structures from lattice-matched ferromagnetic insulators and ferromagnetic conductors is reported. The process is demonstrated by growing a permanently magnetized double-layer structure, consisting of lattice-matched conducting (Ni,Co) and insulating (Ni 0.4 Co 0.6 ) 3 O 3 layers, through a single deposition cycle. The orientation of the metal cation network is preserved after reduction. Close-packing displacements of Ni and Co take place in such a manner that the in-plane hexagonal arrangement is preserved. This is critical for ensuring high-quality interfaces joining the layers. At room temperature the hysteresis loop is centered. At low temperature the oxide layer becomes ferrimagnetically ordered, accompanied by a shift of the hysteresis loop along the magnetic field axis. The shift is assigned to exchange bias phenomenon. Biaxial compressive strain is responsible for the required ferrimagnetic ordering. Finally, spin valves and closely related magnetoresistance random access memory and spin-transfer-torque magnetic random access memory devices are addressed as potential applications.

42 ENGINEERING↗

Interfacial and Kinetic Origins of Voltage Loss in Neutral Zinc‐Air Batteries

Rechargeable zinc-air batteries are promising candidates for grid-scale energy storage; however, their practical deployment is limited by oxygen electrocatalysis inefficiencies and interfacial instabilities, particularly outside conventional alkaline electrolytes. Here, in this work, zinc-air batteries operating under neutral electrolyte conditions using ZnCl 2 soaked KC-PAA-PAM gel polymer electrolytes and electrochemically synthesized Ni/Fe layered double hydroxide electrocatalysts is investigated. Ni/Fe-LDH is intentionally employed as an OER-biased benchmark catalyst to diagnose electrolyte and interface driven limitations rather than as a bifunctional ORR/OER solution. Full cells exhibit highly stable cycling over hundreds of hours, yet operate at substantially suppressed charge and discharge voltages relative to the thermodynamic value. Electrochemical impedance analysis shows that ohmic losses contribute only minimally to this voltage suppression. Post-mortem X-ray photoelectron spectroscopy reveals metallic zinc accumulation on the air cathode and chloride-containing species on the anode, indicating parasitic interfacial processes. Synchrotron-based soft X-ray absorption spectroscopy confirms stable Ni 2+ and Fe 3+ oxidation states during cycling, consistent with OER-biased catalytic behavior, while neutral-electrolyte oxygen evolution measurements demonstrate strong electrolyte-induced suppression of oxygen kinetics. Together, these results show that electrolyte chemistry and cathode-side parasitic processes, rather than catalyst identity alone, dominate voltage losses in neutral zinc-air batteries, providing mechanistic insight into the fundamental challenges associated with neutral electrolyte operation.

Long duration energy storage↗

Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Which G-Tube to Use in Pullers: Assessment of Pull Pressures on Skin Models to Determine Optimal Catheter Choice in Patients with Recurrent Pulled Gastrostomy Tubes

Introduction: Pulled or dislodged gastrostomy catheters represent a common complication associated with percutaneous gastrostomy and are a common cause of recurrent visits in patients with altered mental status. We intended to perform an experiment to compare the pull forces required to dislodge different commonly used gastrostomy catheters. Materials and Methods: We used a digital force gauge device to measure the pull forces required to dislodge three types of 20 French gastrostomy catheters in double-layer skin models. These included the Flow 20 Pull Method (Cook Medical, Bloomington, IN, USA), Entuit Gastrostomy BR Balloon Retention feeding tube (Cook Medical, Bloomington, IN, USA), and Ponsky Non-Balloon Replacement Gastrostomy Tube (CR Bard Inc, Salt Lake City, Utah, USA). The catheters were inserted into the skin model using the same technique as would be utilized in a patient. Results: The mean forces measured to dislodge the per-oral Flow 20 Pull Method, Entuit Thrive Balloon Retention, and button-type retention Ponsky replacement catheters were 35.6, 22.8, and 20.6 Newtons, respectively. The pull method per-oral gastrostomy catheter required significantly more pull force to dislodge than both the Ponsky button-type retention catheter and the Entuit balloon retention catheters. There was no significant difference in the pull force required to dislodge the Ponsky replacement catheter and the Entuit balloon retention catheter. Conclusions: Per-oral image-guided gastrostomy with pull-method button-type retention catheters may be the ideal choice in patients at high risk of tube dislodgment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗