Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Preliminary characterization of a low-powered microwave induced flame plasma for direct organic solvent nebulization

A low powered (<90 W) microwave-induced plasma has been generated at atmospheric pressure by using a Beenakker cavity, a laboratory constructed torch, and a gas mixture of argon (400 ml/min), hydrogen (100 ml/min), and air (130 ml/min). This plasma has an excitation temperature of 3300-3500 K, electron number density of 7 x 10{sup 14} cm{sup -3}, and easily accepts direct methanol and ethanol introduction with a 1 ml/min solution nebulization rate. Detection limits (3{sigma}) obtained from the atomic emission signals of Li, Sr, and Cr in water are 15, 120, and 290 ng/ml, respectively. Similarly, detection limits for the metals in methanol are 15, 120, and 260 ng/ml, respectively, and in ethanol they are 25, 360, and 330 ng/ml, respectively. The linear dynamic range is greater than three orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of nanoscale patterns in lithium fluoride crystal using a 13.5 nm Schwarzschild objective and a laser produced plasma source

Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 {mu}m diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher order parametric excitation modes for spaceborne quadrupole mass spectrometers

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system. When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

An accurate system for onsite calibration of electronic transformers with digital output

Calibration systems with digital output are used to replace conventional calibration systems because of principle diversity and characteristics of digital output of electronic transformers. But precision and unpredictable stability limit their onsite application even development. So fully considering the factors influencing accuracy of calibration system and employing simple but reliable structure, an all-digital calibration system with digital output is proposed in this paper. In complicated calibration environments, precision and dynamic range are guaranteed by A/D converter with 24-bit resolution, synchronization error limit is nanosecond by using the novelty synchronization method. In addition, an error correction algorithm based on the differential method by using two-order Hanning convolution window has good inhibition of frequency fluctuation and inter-harmonics interference. To verify the effectiveness, error calibration was carried out in the State Grid Electric Power Research Institute of China and results show that the proposed system can reach the precision class up to 0.05. Actual onsite calibration shows that the system has high accuracy, and is easy to operate with satisfactory stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPHERES, Juelich's high-flux neutron backscattering spectrometer at FRM II

SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Juelich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 {mu}eV, a dynamic range of {+-} 31 {mu}eV, and a signal-to-noise ratio of up to 1750:1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution and site-specific scanning spreading resistance microscopy and its applications to silicon devices

Due to the continuous reduction of the critical dimensions of semiconductor devices, it becomes very important to know the two dimensional (2D) doping profile for improving device performance. Scanning spreading resistance microscopy (SSRM) performed in high vacuum is a powerful technique for quantitative 2D-doping profiling, with high spatial resolution and wide dynamic range of carrier concentration, as well as capability of site-specific analysis for accurate position. In this paper, we review SSRM applications to source/drain engineering in Si devices and their correlation with device characteristics by demonstrating several case studies. Direct observation of (110)/(100) CMOSFETs clarified significant differences between both pFETs and nFETs on (110) and (100) silicon substrates, revealing 2D channeling effect of boron ion implantation in pFETs; as well as silicidation impact on junction leakage-current characteristics in nFETs. Furthermore, our sample-preparation breakthrough enables site-specific SSRM characterization within 60 nm ultra thin samples and therefore failure analysis of real SRAM devices, demonstrating the high potential of SSRM technology for further device scaling and for failure analysis.

36 MATERIALS SCIENCE↗

K-shell spectroscopy of silicon ions as diagnostic for high electric fields

We developed a detection scheme, capable of measuring X-ray line shape of tracer ions in {mu}m thick layers at the rear side of a target foil irradiated by ultra intense laser pulses. We performed simulations of the effect of strong electric fields on the K-shell emission of silicon and developed a spectrometer dedicated to record this emission. The combination of a cylindrically bent crystal in von Hamos geometry and a CCD camera with its single photon counting capability allows for a high dynamic range of the instrument and background free spectra. This approach will be used in future experiments to study electric fields of the order of TV/m at high density plasmas close to solid density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated evolution of barrier capacitance charging, generation, and drift currents and of carrier lifetime in Si structures during 25 MeV neutrons irradiation

The in situ examination of barrier capacitance charging, of generation and drift currents, and of carrier lifetime in Si structures during 25 MeV neutrons irradiation has been implemented to correlate radiation induced changes in carrier recombination, thermal release, and drift characteristics and to clarify their impact on detector performance. It has been shown that microwave probed photo-conductivity technique implemented in contact-less and distant manner can be a powerful tool for examination in wide dynamic range of carrier lifetime modified by radiation defects and for rather precise prediction of detector performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a DSSSD detector with radioactive sources

The energy calibration of a DSSSD is carried out with the spectra produced by a {sup 207}Bi conversion electron source, a {sup 137}Cs gamma source and a {sup 239}Pu/{sup 241}Am/{sup 244}Cm triple alpha source, as well as employing a precision pulse generator in the whole dynamic range. Multiplicity and coincidence of signals in different strips for the same event are also studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous optical switching and thermal hysteresis during semiconductor-metal phase transition of VO{sub 2} films on Si substrate

We present a detailed infrared study of the semiconductor-to-metal transition (SMT) in a vanadium dioxide (VO{sub 2}) film deposited on silicon wafer. The VO{sub 2} phase transition is studied in the mid-infrared region by analyzing the transmittance and the reflectance measurements, and the calculated emissivity. The reflectance has been measured in two configurations: from the side of the VO{sub 2} film and from that of Si wafer. The results show a strong asymmetry between the emissivity in the two configurations, and the fact that the emissivity dynamic range from the silicon side is twice as large than that from the VO{sub 2} side. The temperature behaviour of the emissivity during the SMT put into evidence the phenomenon of the anomalous absorption in VO{sub 2}, which has been explained by applying the Maxwell Garnett effective medium approximation theory.

36 MATERIALS SCIENCE↗

A novel self-sensing technique for tapping-mode atomic force microscopy

This work proposes a novel self-sensing tapping-mode atomic force microscopy operation utilizing charge measurement. A microcantilever coated with a single piezoelectric layer is simultaneously used for actuation and deflection sensing. The cantilever can be batch fabricated with existing micro electro mechanical system processes. The setup enables the omission of the optical beam deflection technique which is commonly used to measure the cantilever oscillation amplitude. Due to the high amount of capacitive feedthrough in the measured charge signal, a feedforward control technique is employed to increase the dynamic range from less than 1 dB to approximately 35 dB. Experiments show that the conditioned charge signal achieves excellent signal-to-noise ratio and can therefore be used as a feedback signal for atomic force microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bootstrapped, low-noise, and high-gain photodetector for shot noise measurement

We presented a low-noise, high-gain photodetector based on the bootstrap structure and the L-C (inductance and capacitance) combination. Electronic characteristics of the photodetector, including electronic noise, gain and frequency response, and dynamic range, were verified through a single-frequency Nd:YVO{sub 4} laser at 1064 nm with coherent output. The measured shot noise of 50 μW laser was 13 dB above the electronic noise at the analysis frequency of 2 MHz, and 10 dB at 3 MHz. And a maximum clearance of 28 dB at 2 MHz was achieved when 1.52 mW laser was illuminated. In addition, the photodetector showed excellent linearities for both DC and AC amplifications in the laser power range between 12.5 μW and 1.52 mW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Color-based tracking of plasma dust particles

Color-based tracking to observe agglomeration of deposited particles inside a compact planar magnetron during plasma discharge was done by creating high dynamic range (HDR) images of photos captured by a Pentax K10D digital camera. Carbon erosion and redeposition was also monitored using the technique. The HDR images were subjected to a chromaticity-based constraint discoloration inside the plasma chamber indicating film formation or carbon redeposition. Results show that dust deposition occurs first near the evacuation pumps due to the pressure gradient and then accumulates at the positively charged walls of the chamber. This method can be applied to monitor dust formation during dusty plasma experiments without major modification of plasma devices, useful especially for large fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effective terahertz-to-near-infrared photon conversion in slant-stripe-type periodically poled LiNbO{sub 3}

We propose a slant-stripe-type periodically poled LiNbO{sub 3} crystal for the construction of a practical quasi-phase-matched (QPM) device for terahertz (THz) detection. A minimum detectable THz-wave energy of 25 fJ/pulse is demonstrated, and a linear input-output property with a dynamic range of 60 dB is achieved. The working frequency range of 0.15 THz for THz detection is obtained, and the central frequency of the sensitivity can be controlled by the design of the periodically poled structure. THz detection using this QPM device is a promising technique that may allow the detection of a coherent THz photon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A direct measurement of the electronic structure of Si nanocrystals and its effect on optoelectronic properties

Since reports that silicon nanocrystals (Si-NCs) can exhibit direct transition emission, the silicon laser field is at a juncture where the importance of this discovery needs to be evaluated. Most theoretical models predicted a monotonic increase in the bandgap and experimental information currently available on the electronic structure at the Γ valley of these promising materials is circumstantial as it is obtained from emission measurements where competing non-radiative relaxation and recombination processes only provide an incomplete picture of the electronic structure of Si-NCs. Optical absorption, the most immediate probe of the electronic structure beyond the band-edges, showing the evolution of the Γ valley states with nanocrystal size has not been measured. Here, we show such measurements, performed with high dynamic range, allowing us to observe directly the effect of crystal size on the Γ valley splitting far above the band-edges. We show that the splitting is 100 s of meV more pronounced than predicted by pseudo potential calculations and Luttinger-Kohn model. We also show that ultrafast red-shifting emission can be observed in plasma enhanced chemical vapor deposition prepared Si-NCs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗