Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end, tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.

60 APPLIED LIFE SCIENCES↗

Structure Discovery in Large Semantic Graphs Using Extant Ontological Scaling and Descriptive Statistics

As semantic datasets grow to be very large and divergent, there is a need to identify and exploit their inherent semantic structure for discovery and optimization. Towards that end, we present here a novel methodology to identify the semantic structures inherent in an arbitrary semantic graph dataset. We first present the concept of an extant ontology as a statistical description of the semantic relations present amongst the typed entities modeled in the graph. This serves as a model of the underlying semantic structure to aid in discovery and visualization. We then describe a method of ontological scaling in which the ontology is employed as a hierarchical scaling filter to infer different resolution levels at which the graph structures are to be viewed or analyzed. We illustrate these methods on three large and publicly available semantic datasets containing more than one billion edges each. Keywords-Semantic Web; Visualization; Ontology; Multi-resolution Data Mining;

Multiresolution Data Mining↗

Simultaneous imaging of two-phase velocities in particle-laden flows by two-color optical phase discrimination

In this Letter, we present a particle image/tracking velocimetry (PIV/PTV) technique for simultaneous velocity measurement of both fluid and particle phases, adopting newly developed optical phase discrimination methods and novel optical particles. Spherical acrylic (PMMA) particles of diameter ∼ <#comment/> O ( 100 µ <#comment/> m ) were used as the particle phase, while fine B A M : E u 2 + phosphors of diameter ∼ <#comment/> O ( 1 µ <#comment/> m ) were used as the fluid tracer. Under Nd:YAG 355 nm laser excitation, both the laser-induced fluorescence (LIF) from PMMA and laser-induced phosphorescence (LIP) from B A M : E u 2 + provided sufficiently strong signals for PIV imaging with two non-intensified cameras and were clearly separable for phase discrimination using spectral filters and temporal profiles. The advantages of the PIV/PTV method include the relatively low cost of B A M : E u 2 + phosphors, high sphericity and narrow size distribution of PMMA particles with LIF emission, and direct optical discrimination eliminating artifacts, while requiring much less computational capacity for PIV/PTV processing of complex particle-laden flows.

Bi, Xiaopeng (ORCID:0000000190847325)↗

Uncertainty analysis technique for OMEGA Dante measurements

The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Component separation of a isotropic Gravitational Wave Background

A Gravitational Wave Background (GWB) is expected in the universe from the superposition of a large number of unresolved astrophysical sources and phenomena in the early universe. Each component of the background (e.g., from primordial metric perturbations, binary neutron stars, milli-second pulsars etc.) has its own spectral shape. Many ongoing experiments aim to probe GWB at a variety of frequency bands. In the last two decades, using data from ground-based laser interferometric gravitational wave (GW) observatories, upper limits on GWB were placed in the frequency range of 0∼ 50−100 Hz, considering one spectral shape at a time. However, one strong component can significantly enhance the estimated strength of another component. Hence, estimation of the amplitudes of the components with different spectral shapes should be done jointly. Here we propose a method for 'component separation' of a statistically isotropic background, that can, for the first time, jointly estimate the amplitudes of many components and place upper limits. The method is rather straightforward and needs negligible amount of computation. It utilises the linear relationship between the measurements and the amplitudes of the actual components, alleviating the need for a sampling based method, e.g., Markov Chain Monte Carlo (MCMC) or matched filtering, which are computationally intensive and cumbersome in a multi-dimensional parameter space. Using this formalism we could also study how many independent components can be separated using a given dataset from a network of current and upcoming ground based interferometric detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning study

Purpose: To demonstrate the feasibility of photon energy-modulated radiotherapy during beam-on time. Methods: A cylindrical device made of aluminum was conceptually proposed as an energy modulator. The frame of the device was connected with 20 tubes through which mercury could be injected or drained to adjust the thickness of mercury along the beam axis. In Monte Carlo (MC) simulations, a flattening filter of 6 or 10 MV linac was replaced with the device. The thickness of mercury inside the device varied from 0 to 40 mm at the field sizes of 5 x 5 cm{sup 2} (FS5), 10 x 10 cm{sup 2} (FS10), and 20 x 20 cm{sup 2} (FS20). At least 5 billion histories were followed for each simulation to create phase space files at 100 cm source to surface distance (SSD). In-water beam data were acquired by additional MC simulations using the above phase space files. A treatment planning system (TPS) was commissioned to generate a virtual machine using the MC-generated beam data. Intensity modulated radiation therapy (IMRT) plans for six clinical cases were generated using conventional 6 MV, 6 MV flattening filter free, and energy-modulated photon beams of the virtual machine. Results: As increasing the thickness of mercury, Percentage depth doses (PDD) of modulated 6 and 10 MV after the depth of dose maximum were continuously increased. The amount of PDD increase at the depth of 10 and 20 cm for modulated 6 MV was 4.8% and 5.2% at FS5, 3.9% and 5.0% at FS10 and 3.2%-4.9% at FS20 as increasing the thickness of mercury from 0 to 20 mm. The same for modulated 10 MV was 4.5% and 5.0% at FS5, 3.8% and 4.7% at FS10 and 4.1% and 4.8% at FS20 as increasing the thickness of mercury from 0 to 25 mm. The outputs of modulated 6 MV with 20 mm mercury and of modulated 10 MV with 25 mm mercury were reduced into 30%, and 56% of conventional linac, respectively. The energy-modulated IMRT plans had less integral doses than 6 MV IMRT or 6 MV flattening filter free plans for tumors located in the periphery while maintaining the similar quality of target coverage, homogeneity, and conformity. Conclusions: The MC study for the designed energy modulator demonstrated the feasibility of energy-modulated photon beams available during beam-on time. The planning study showed an advantage of energy-and intensity modulated radiotherapy in terms of integral dose without sacrificing any quality of IMRT plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A filtered tabulated chemistry model for LES of premixed combustion

A new modeling strategy called F-TACLES (Filtered Tabulated Chemistry for Large Eddy Simulation) is developed to introduce tabulated chemistry methods in Large Eddy Simulation (LES) of turbulent premixed combustion. The objective is to recover the correct laminar flame propagation speed of the filtered flame front when subgrid scale turbulence vanishes as LES should tend toward Direct Numerical Simulation (DNS). The filtered flame structure is mapped using 1-D filtered laminar premixed flames. Closure of the filtered progress variable and the energy balance equations are carefully addressed in a fully compressible formulation. The methodology is first applied to 1-D filtered laminar flames, showing the ability of the model to recover the laminar flame speed and the correct chemical structure when the flame wrinkling is completely resolved. The model is then extended to turbulent combustion regimes by including subgrid scale wrinkling effects in the flame front propagation. Finally, preliminary tests of LES in a 3-D turbulent premixed flame are performed. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer

Purpose: To evaluate the potential usage of flattening filter-free (FFF) photon beams in the treatment of prostate cancer. Methods and Materials: Volumetric-modulated arc therapy (VMAT) treatment planning was performed for 7 patients using TrueBeam{sup Registered-Sign} linear accelerator and photon beams with (X6, X10) and without (X6FFF, X10FFF) flattening filter. Prescribed dose was 19 Multiplication-Sign 3 Gy = 57 Gy. One or two 360 Degree-Sign arcs with dose rate of 600 MU/min for flattened beams, and 1,200 MU/min for FFF beams were used. Results: No difference was detected between the four beams in PTV coverage, conformity, and homogeneity. Mean body dose and body volume receiving 50% of the prescribed dose decreased with increasing mean energy (r{sup 2} = 0.8275, p < 0.01). X6FFF delivered 3.6% more dose compared with the X6 (p < 0.01). X10FFF delivered 3.0% (p < 0.01), and the X10 5.8% (p < 0.01) less mean body dose compared with X6. There was a significant increase in the mean dose to the rectum for the X10 compared with X6 (2.6%, p < 0.01). Mean dose to the bladder increased by 1.3% for X6FFF and decreased by 2.3% for X10FFF. Using a single arc and FFF, treatment time was reduced by 35% (2 SD = 10%). Conclusion: FFF beams resulted in dose distributions similar to flattened beams. X10FFF beam provided the best solution, sparing rectum and bladder and minimizing whole-body dose. FFF beams lead to a time efficient treatment delivery, particularly when combined with hypofractionated VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Titanium dioxide, single-walled carbon nanotube composites

The present invention provides titanium dioxide/single-walled carbon nanotube composites (TiO.sub.2/SWCNTs), articles of manufacture, and methods of making and using such composites. In certain embodiments, the present invention provides membrane filters and ceramic articles that are coated with TiO.sub.2/SWCNT composite material. In other embodiments, the present invention provides methods of using TiO.sub.2/SWCNT composite material to purify a sample, such as a water or air sample.

36 MATERIALS SCIENCE↗

Filters for blocking macroparticles in plasma deposition apparatus

This disclosure provides systems, methods, and apparatus related to blocking macroparticles in deposition processes utilizing plasmas. In one aspect, an apparatus includes a cathode, a substrate holder, a first magnet, a second magnet, and a structure. The cathode is configured to generate a plasma. The substrate holder is configured to hold a substrate. The first magnet is disposed proximate a first side of the cathode. The second magnet is disposed proximate a second side of the substrate holder. A magnetic field exists between the first magnet and the second magnet and a flow of the plasma substantially follows the magnetic field. The structure is disposed between the second side of the cathode and the first side of the substrate holder and is positioned proximate a region where the magnetic field between the first magnet and the second magnet is weak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A DEEP, WIDE-FIELD, AND PANCHROMATIC VIEW OF 47 Tuc AND THE SMC WITH HST: OBSERVATIONS AND DATA ANALYSIS METHODS

In Hubble Space Telescope (HST) Cycle 17, we imaged the well-known globular star cluster 47 Tucanae for 121 orbits using the Wide Field Channel of the Advanced Camera for Surveys (ACS) and both the UV/visible (UVIS) and IR channels of the newly installed Wide Field Camera 3 (WFC3) instrument (GO-11677, PI: H. Richer). This unique data set was obtained to address many scientific questions that demand a very deep, panchromatic, and panoramic view of the cluster's stellar populations. In total, the program obtained over 0.75 Ms of imaging exposure time with the three HST cameras, over a time span of 9 months in 2010. The primary ACS field was imaged in the two broadband filters F606W and F814W, at 13 orientations, for all 121 orbits. The parallel WFC3 imaging provides a panchromatic (0.4-1.7 {mu}m) and contiguous imaging swath over a 250 Degree-Sign azimuthal range at impact radii of 6.5-17.9 pc in 47 Tuc. This imaging totals over 60 arcmin{sup 2} in area and utilizes the F390W and F606W broadband filters on WFC3/UVIS and the F110W and F160W broadband filters on WFC3/IR. In this paper, we describe the observational design of the new survey and one of the methods used to analyze all of the imaging data. This analysis combines over 700 full-frame images taken with the three HST cameras into a handful of ultra-deep, well-sampled combined images in each of the six filters. We discuss in detail the methods used to calculate accurate transformations that provide optimal alignment of the input images, the methods used to perform sky background offsets in the input stack and the flagging of deviant pixels, and the balance reached between the input-pixel drop size onto an output supersampled pixel grid. Careful photometric, morphological, and astrometric measurements are performed on the stacks using iterative PSF-fitting techniques, and reveal unprecedented color-magnitude diagrams of the cluster extending to >30th magnitude in the optical, 29th magnitude in the UV, and 27th magnitude in the IR. The data set provides a characterization of the complete stellar populations of 47 Tuc, extending from the faintest hydrogen-burning dwarfs through the main-sequence and giant branches down to very cool white dwarf remnants in the cluster. The imaging also provides the deepest probe of the stellar populations of the background Small Magellanic Cloud galaxy, resolving low-mass main-sequence dwarfs with M {approx}< 0.2 M{sub Sun }.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time event reconstruction for Nuclear Physics Experiments using Artificial Intelligence

Charged track reconstruction is a critical task in nuclear physics experiments, enabling the identification and analysis of particles produced in high-energy collisions. Machine learning (ML) has emerged as a powerful tool for this purpose, addressing the challenges posed by complex detector geometries, high event multiplicities, and noisy data. Traditional methods rely on pattern recognition algorithms like the Kalman filter, but ML techniques, such as neural networks, graph neural networks (GNNs), and recurrent neural networks (RNNs), offer improved accuracy and scalability. By learning from simulated and real detector data, ML models can identify and classify tracks, predict trajectories, and handle ambiguities caused by overlapping or missing hits. Moreover, ML-based approaches can process data in near-real-time, enhancing the efficiency of experiments at large-scale facilities like the Large Hadron Collider (LHC) and Jefferson Lab (JLAB). As detector technologies and computational resources evolve, ML-driven charged track reconstruction continues to push the boundaries of precision and discovery in nuclear physics. In these proceedings, we highlight advancements in charged track identification leveraging Artificial Intelligence within the CLAS12 detector, achieving a notable enhancement in experimental statistics compared to traditional methods. Additionally, we showcase real-time event reconstruction capabilities, including the inference of charged particle properties, such as momentum, direction, and species identification, at speeds matching data acquisition rates. These innovations enable the extraction of physics observables directly from the experiment in real-time.

Gavalian, Gagik (ORCID:0000000267385457)↗

U.S. residential consumer product information: Validation of methods for post-stratification weighting of Amazon Mechanical Turk surveys

We present two post-stratification weighting methods to validate survey data collected using Amazon Mechanical Turk (AMT). Two surveys focused on appliance and consumer electronics devices were administered in the spring and summer of 2012 to each of approximately 3,000 U.S. households. Specifically, the surveys asked questions about residential refrigeration products, televisions (TVs) and set-top boxes (STBs). Filtered data were assigned weights using each of two weighting methods, termed “sequential” and “simultaneous,” by examining up to eight demographic variables (income, education, gender, race, Hispanic origin, number of occupants, ages of occupants, and geographic region) in comparison to reference U.S. demographic data from the 2009 Residential Energy Consumption Survey (RECS). Five key questions from the surveys (number of refrigerators, number of freezers, number of TVs, number of STBs and primary service provider) were evaluated with a set of statistical tests to determine whether either method improved the agreement of AMT with reference data, and if so, which method was better. The statistical tests used were: differences in proportions, distributions of proportions (using Pearson’s chi-squared test), and differences in average numbers of devices as functions of all demographic variables. The results indicated that both methods generally improved the agreement between AMT and reference data, sometimes greatly, but that the simultaneous method was usually superior to the sequential method. Some differences in sample populations were found between the AMT and reference data. Differences in the proportion of STBs reflected large changes in the STB market since the time our reference data was acquired in 2009. Differences in the proportions of some primary service providers suggested real sample bias, with the possible explanation that AMT user are more likely to subscribe to providers who also provide home internet service. Differences in other variables, while statistically significant in some cases, were nonetheless considered to be minor. Depending on the intended purpose of the data collected using AMT, these biases may or may not be important; to correct them, additional questions and/or further post-survey adjustments could be employed. In general, based on the analysis methods and the sample datasets used in this study, AMT surveys appeared to provide useful data on appliance and consumer electronics devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crowded Field Galaxy Photometry: Precision Colors in the CLASH Clusters

We present a new method for photometering objects in galaxy clusters. We introduce a mode-filtering technique for removing spatially variable backgrounds, improving both detection and photometric accuracy (roughly halving the scatter in the red sequence compared to previous catalogs of the same clusters). This method is based on robustly determining the distribution of background pixel values and should provide comparable improvement in photometric analysis of any crowded fields. We produce new multiwavelength catalogs for the 25 CLASH cluster fields in all 16 bandpasses from the UV through the near-IR, as well as rest-frame magnitudes. A comparison with spectroscopic values from the literature finds a ∼30% decrease in the redshift deviation from previously released CLASH photometry. This improvement in redshift precision, in combination with a detection scheme designed to maximize purity, yields a substantial upgrade in cluster member identification over the previous CLASH galaxy catalog. We construct luminosity functions for each cluster, reliably reaching depths of at least 4.5 mag below M* in every case, and deeper still in several clusters. We measure M* , α, and their redshift evolution, assuming the cluster populations are coeval, and find little to no evolution of α,−0.9≲〈α〉≲−0.8, and M* values consistent with passive evolution. We present a catalog of galaxy photometry, photometric and spectroscopic redshifts, and rest-frame photometry for the full fields of view of all 25 CLASH clusters. Not only will our new photometric catalogs enable new studies of the properties of CLASH clusters, but mode-filtering techniques, such as those presented here, should greatly enhance the data quality of future photometric surveys of crowded fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust and accurate filtered spherical harmonics expansions for radiative transfer

We present a novel application of filters to the spherical harmonics (P{sub N}) expansion for radiative transfer problems in the high-energy-density regime. The filter we use is based on non-oscillatory spherical splines and a filter strength chosen to (i) preserve the equilibrium diffusion limit and (ii) vanish as the expansion order tends to infinity. Our implementation is based on modified equations that are derived by applying the filter after every time step in a simple first-order time integration scheme. The method is readily applied to existing codes that solve the P{sub N} equations. Numerical results demonstrate that the solution to the filtered P{sub N} equations are (i) more robust and less oscillatory than standard P{sub N} solutions and (ii) more accurate than discrete ordinates solutions of comparable order. In particular, the filtered P{sub 7} solution demonstrates comparable accuracy to an implicit Monte Carlo solution for a benchmark hohlraum problem in 2D Cartesian geometry.

97 MATHEMATICS AND COMPUTING↗

Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canister integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dual curved photonic crystal ring resonator based channel drop filter using two-dimensional photonic crystal structure

In this paper channel drop filter (CDF) is designed using dual curved photonic crystal ring resonator (PCRR). The photonic band gap (PBG) is calculated by plane wave expansion (PWE) method and the photonic crystal (PhC) based on two dimensional (2D) square lattice periodic arrays of silicon (Si) rods in air structure have been investigated using finite difference time domain (FDTD) method. The number of rods in Z and X directions is 21 and 20 respectively with lattice constant 0.540 nm and rod radius r = 0.1 µm. The channel drop filter has been optimized for telecommunication wavelengths λ = 1.591 µm with refractive indices 3.533. In the designed structure further analysis is also done by changing whole rods refractive index and it has been observed that this filter may be used for filtering several other channels also. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗