Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BM3DORNL

BM3DORNL is a high-performance, open-source library for removing streak and ring artifacts from computed-tomography (CT) data, developed for neutron imaging at Oak Ridge National Laboratory's Spallation Neutron Source (VENUS beamline) and applicable to X-ray CT as well. Ring artifacts — concentric rings in reconstructed slices caused by detector pixel-to-pixel response non-uniformities — appear as vertical streaks in the sinogram and degrade both image quality and quantitative analysis. BM3DORNL operates in the sinogram domain using an adaptation of the BM3D (block-matching and 3D collaborative filtering) algorithm (Dabov et al., 2007). It provides a dedicated streak-removal mode, a true multi-scale BM3D variant (after Mäkinen et al., 2021) that suppresses wide streaks single-scale methods miss, and an alternative Fourier–SVD method (~2.6× faster) combining FFT-based energy detection with rank-1 SVD. The computationally intensive core is implemented in Rust with parallel (Rayon) block matching, integral-image pre-screening, and optimized transforms, and is exposed through a simple Python API (with an optional GUI) so it integrates directly into existing tomography reconstruction pipelines. It processes both 2D sinograms and 3D sinogram stacks, is pip-installable for Linux and macOS, and is documented at https://bm3dornl.readthedocs.io.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Automatic Detection and Evaluation of Solar Cell Micro-Cracks in Electroluminescence Images Using Matched Filters

A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potential for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.

14 SOLAR ENERGY↗

SU-E-J-126: An Online Replanning Method for FFF Beams Without Couch Shift

Purpose: In a situation that couch shift for patient positioning is not preferred or prohibited (e.g., MR-Linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening filter free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here we propose a new 2-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online steps. The offline step is to create a series of pre-shifted plans (PSP) obtained by a so called “warm start” optimization (starting optimization from the original plan, rather from scratch) at a series of isocenter shifts with fixed distance (e.g. 2 cm, at x,y,z = 2,0,0 ; 2,2,0 ; 0,2,0; …;− 2,0,0). The PSPs all have the same number of segments with very similar shapes, since the warm-start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated, and instantaneously fast (no optimization or dose calculation needed). The previously-developed SAM algorithm is then applied for daily deformation. We tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusion: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation requiring no additional time from the SAM process. This research was supported by Elekta inc. (Crawley, UK)

60 APPLIED LIFE SCIENCES↗

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗

Discovery of hybrid chemical synthesis pathways with DORAnet

Developing efficient tools for discovering novel synthesis pathways is essential to advance chemical production methods that maximize the use of resources and energy. We introduce DORAnet (Designing Optimal Reaction Avenues Network Enumeration Tool), an open-source computational framework that addresses key limitations in current computer-aided synthesis planning (CASP) tools. DORAnet integrates both chemical/chemocatalytic (i.e., non-enzymatic) and enzymatic transformations, enabling the discovery of hybrid synthesis pathways. With 390 expert-curated chemical/chemocatalytic reaction rules and 3606 enzymatic rules derived from MetaCyc, it provides extensive flexibility for synthetic chemists and biotechnologists. The framework features customizable network expansion strategies, advanced filtering, and pathway search, ranking, and visualization tools. Validated against known reaction data, DORAnet successfully identified both established and novel synthesis routes for key industrial chemicals. In a case study involving 51 high-volume targets, DORAnet frequently ranked known commercial pathways among the top three results, demonstrating its practical relevance and ranking accuracy, while also uncovering numerous alternative (hybrid) synthesis pathways that were highly ranked.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical performance and image optimization of megavoltage cone-beam CT

Megavoltage cone-beam CT (MVCBCT) is the most recent addition to the in-room CT systems developed for image-guided radiation therapy. The first generation MVCBCT system consists of a 6 MV treatment x-ray beam produced by a conventional linear accelerator equipped with a flat panel amorphous silicon detector. The objective of this study was to evaluate the physical performance of MVCBCT in order to optimize the system acquisition and reconstruction parameters for image quality. MVCBCT acquisitions were performed with the clinical system but images were reconstructed and analyzed with a separate research workstation. The geometrical stability and the positioning accuracy of the system were evaluated by comparing geometrical calibrations routinely performed over a period of 12 months. The beam output and detector intensity stability during MVCBCT acquisition were also evaluated by analyzing in-air acquisitions acquired at different exposure levels. Several system parameters were varied to quantify their impact on image quality including the exposure (2.7, 4.5, 9.0, 18.0, and 54.0 MU), the craniocaudal imaging length (2, 5, 15, and 27.4 cm), the voxel size (0.5, 1, and 2 mm), the slice thickness (1, 3, and 5 mm), and the phantom size. For the reconstruction algorithm, the study investigated the effect of binning, averaging and diffusion filtering of raw projections as well as three different projection filters. A head-sized water cylinder was used to measure and improve the uniformity of MVCBCT images. Inserts of different electron densities were placed in a water cylinder to measure the contrast-to-noise ratio (CNR). The spatial resolution was obtained by measuring the point-spread function of the system using an iterative edge blurring technique. Our results showed that the geometric stability and accuracy of MVCBCT were better than 1 mm over a period of 12 months. Beam intensity variations per projection of up to 35.4% were observed for a 2.7 MU MVCBCT acquisition. These variations did not cause noticeable reduction in the image quality. The results on uniformity suggest that the cupping artifact occurring with MVCBCT is mostly due to off-axis response of the detector and not scattered radiation. Simple uniformity correction methods were developed to nearly eliminate this cupping artifact. The spatial resolution of the baseline MVCBCT reconstruction protocol was approximately 2 mm. An optimized reconstruction protocol was developed and showed an improvement of 75% in CNR with a penalty of only 8% in spatial resolution. Using this new reconstruction protocol, large adipose and muscular structures were differentiated at an exposure of 9 MU. A reduction of 36% in CNR was observed on a larger (pelvic-sized) phantom. This study demonstrates that soft-tissue visualization with MVCBCT can be substantially improved with proper system settings. Further improvement is expected from the next generation MVCBCT system with an optimized megavoltage imaging beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraints on the flux of Ultra-High Energy neutrinos from WSRT observations

Context. Ultra-high energy (UHE) neutrinos and cosmic rays initiate particle cascades underneath the Moon's surface. These cascades have a negative charge excess and radiate Cherenkov radio emission in a process known as the Askaryan effect. The optimal frequency window for observation of these pulses with radio telescopes on the Earth is around 150 MHz. Aims. By observing the Moon with the Westerbork Synthesis Radio Telescope array we are able to set a new limit on the UHEneutrino flux. Methods. The PuMa II backend is used to monitor the Moon in 4 frequency bands between 113 and 175 MHz with a sampling frequency of 40 MHz. The narrow band radio interference is digitally filtered out and the dispersive effect of the Earth?s ionosphere is compensated for. A trigger system is implemented to search for short pulses. By inserting simulated pulses in the raw data, the detection efficiency for pulses of various strength is calculated. Results. With 47.6 hours of observation time, we are able to set a limit on the UHE neutrino flux. This new limit is an order of magnitude lower than existing limits. In the near future, the digital radio array LOFAR will be used to achieve an even lower limit.

79 ASTRONOMY AND ASTROPHYSICS↗

A unified funnel restoration SQP algorithm

We consider nonlinearly constrained optimization problems and discuss a generic double-loop framework consisting of basic algorithmic ingredients that unifies a broad range of nonlinear optimization solvers. This framework has been implemented in the open-source solver Uno, a Swiss Army knife-like C++ optimization framework that unifies many nonlinearly constrained nonconvex optimization solvers. We illustrate the framework with a sequential quadratic programming (SQP) algorithm that maintains an acceptable upper bound on the constraint violation, called a funnel, that is monotonically decreased to control the feasibility of the iterates. Infeasible quadratic subproblems are handled by a feasibility restoration strategy. Globalization is controlled by a line search or a trust-region method. We prove global convergence of the trust-region funnel SQP method, building on known results from filter methods. We implement the algorithm in Uno, and we provide extensive test results for the trust-region line-search funnel SQP on small CUTEst instances.

Kiessling, David [Katholieke Univ. Leuven, Heverle↗

Design of a supervisory control system for autonomous operation of advanced reactors

Advanced reactors to be deployed in the coming decades will face deregulated energy markets, and may adopt flexible operation to boost profitability. To aid in the transition from baseload to flexible operation paradigm, autonomous operation is sought. This work focuses on the control aspect of autonomous operation. Specifically, a hierarchical control system is designed to support constraint enforcement during routine operational transients. Within the system, data-driven modeling, physics-based state observation, and classical control algorithms are integrated to provide an adaptable and robust solution. A 320 MW Fluoride-cooled High-temperature Pebble-bed Reactor is the design basis for demonstrating the proposed control system. The hierarchical control system consists of a supervisory layer and low-level layer. The supervisory layer receives requests to change the system's operating conditions (e.g., the current reactor power to meet a load -follow), and accepts or rejects them based on constraints that have been assigned. Constraints are issued to keep the plant within an optimal operating region. The low-level layer interfaces with the actuators of the system to fulfill requested changes, while maintaining tracking and regulation duties. Further, to accept requests at the supervisory layer, the Reference Governor algorithm was adopted. To model the dynamics of the reactor, a system identification algorithm, Dynamic Mode Decomposition, was utilized. To estimate the evolution of process variables that cannot be directly measured (e.g., the propagation of delayed neutron precursors), the Unscented Kalman Filter, incorporating a nonlinear model of nuclear dynamics, was adopted. The composition of these algorithms led to a numerical demonstration of constraint enforcement during a 40% power drop transient (at a rate of 5 %/min). Uncontrolled secondary-side temperatures were successfully constrained. Adaptability of the proposed system was demonstrated by modifying the constraint values, and enforcing them during the transient. Robustness was also demonstrated by enforcing constraints under noisy environments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of persistent contaminants and personal care products by dispersive liquid-liquid microextraction using hydrophobic magnetic deep eutectic solvents

Here, in this work, hydrophobic magnetic deep eutectic solvents (HMDESs) were used in the development of a simple and rapid dispersive liquid-liquid microextraction (DLLME) approach coupled to high performance liquid chromatography with UV detection (HPLC-UV) for the determination of ten organic contaminants including five polycyclic aromatic hydrocarbons, four UV filters, and a pesticide from water at trace levels. The HMDESs were prepared by mixing a hydrogen bond acceptor, metal halide salt, and hydrogen bond donor in suitable molar ratios. Two HMDESs, 2 tetraoctylammonium bromide ([N 8888 + ][Br - ]): cobalt chloride (CoCl 2 ): 4 octanoic acid (OA) and 3 trioctylphosphine oxide (TOPO): neodymium chloride (NdCl 3 ): 3 OA, offered the highest analyte extraction efficiency overall and were chosen as suitable solvents for validation of the microextraction method. Under optimized extraction conditions, the method required 30 µL of HMDES as extraction solvent, acetone (87.5 µL) as disperser solvent, a NaCl concentration of 30% (w/v), and an extraction time of 120 s at 20°C. Enrichment factors of the analytes ranged from 44.6 for 3-(4-methylbenzylindene) camphor to 66.0 for 2-ethylhexyl-4-(dimethyl)aminobenzoate. The method provided low limits of detection (LODs) ranging from 0.5 to 4.5 µg L -1 , and acceptable precision, with RSD values lower than 9.6%. Furthermore, the validated method was successfully applied for tap and lake water analysis, resulting in relative recoveries of spiked samples ranging between 94.7 and 119.2%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SAR Imagery Segmentation by Statistical Region Growing and Hierarchical Merging

This paper presents an approach to accomplish synthetic aperture radar (SAR) image segmentation, which are corrupted by speckle noise. Some ordinary segmentation techniques may require speckle filtering previously. Our approach performs radar image segmentation using the original noisy pixels as input data, eliminating preprocessing steps, an advantage over most of the current methods. The algorithm comprises a statistical region growing procedure combined with hierarchical region merging to extract regions of interest from SAR images. The region growing step over-segments the input image to enable region aggregation by employing a combination of the Kolmogorov-Smirnov (KS) test with a hierarchical stepwise optimization (HSWO) algorithm for the process coordination. We have tested and assessed the proposed technique on artificially speckled image and real SAR data containing different types of targets.

42 ENGINEERING↗

Dose reconstruction for real-time patient-specific dose estimation in CT

Purpose: Many recent computed tomography (CT) dose reduction approaches belong to one of three categories: statistical reconstruction algorithms, efficient x-ray detectors, and optimized CT acquisition schemes with precise control over the x-ray distribution. The latter category could greatly benefit from fast and accurate methods for dose estimation, which would enable real-time patient-specific protocol optimization. Methods: The authors present a new method for volumetrically reconstructing absorbed dose on a per-voxel basis, directly from the actual CT images. The authors’ specific implementation combines a distance-driven pencil-beam approach to model the first-order x-ray interactions with a set of Gaussian convolution kernels to model the higher-order x-ray interactions. The authors performed a number of 3D simulation experiments comparing the proposed method to a Monte Carlo based ground truth. Results: The authors’ results indicate that the proposed approach offers a good trade-off between accuracy and computational efficiency. The images show a good qualitative correspondence to Monte Carlo estimates. Preliminary quantitative results show errors below 10%, except in bone regions, where the authors see a bigger model mismatch. The computational complexity is similar to that of a low-resolution filtered-backprojection algorithm. Conclusions: The authors present a method for analytic dose reconstruction in CT, similar to the techniques used in radiation therapy planning with megavoltage energies. Future work will include refinements of the proposed method to improve the accuracy as well as a more extensive validation study. The proposed method is not intended to replace methods that track individual x-ray photons, but the authors expect that it may prove useful in applications where real-time patient-specific dose estimation is required.

60 APPLIED LIFE SCIENCES↗

Count Rate Optimizations for TES Detectors at a Femtosecond X-ray Laser

Transition-edge sensor microcalorimeters have found success as X-ray detectors at synchrotron light-sources, due to a unique combination of high collecting area and good energy resolution. However, the upcoming generation of free-electron lasers (FELs), such as the Linac Coherent Light Source II, is designed to deliver more than 10 10 photons in a 100 fs pulse at a 100 kHz rate, potentially leading to severe pulse-pileup issues. Here we will demonstrate that, for most relevant science cases, it is possible to mitigate pulse pile-up using simple X-ray filters in a way that takes advantage of the substantial increase in X-ray flux at modern FELs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis of graphene-like transparent conductive films on dielectric substrates using a modified filtered vacuum arc system

Here, we present a reliable process to deposit transparent conductive films on silicon oxide, quartz, and sapphire using a solid carbon source. This layer consists of partially ordered graphene flakes with a lateral dimension of about 5 nm. The process does not require any catalytic metal and exploits a high current arc evaporation (Φ-HCA) to homogeneously deposit a layer of carbon on heated substrates. A gas atmosphere consisting of Argon or Argon/Hydrogen blend acting as a buffer influences the morphology of the growing film. scanning tunneling microscopy, transmission electron microscopy, and Raman spectra were used for a thorough characterization of the samples in order to optimize the growth parameters. The best carbon layers have a surface resistance of 5.7 × 10{sup 3} Ω{sub ◻} whereas the optical transparency of the coatings is 88% with an excellent homogeneity over areas of several cm{sup 2}. Such results are compatible with most semiconductor fabrication processes and make this method very promising for various industrial applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-sensitivity detection of polycyclic aromatic hydrocarbons adsorbed onto soot particles using laser desorption/laser ionization/time-of-flight mass spectrometry: An approach to studying the soot inception process in low-pressure flames

Species adsorbed at the surfaces of soot particles sampled at different locations in a low-pressure methane flame have been analyzed. The analysis method is laser desorption/laser ionization/time-of-flight mass spectrometry (LD/LI/TOF-MS) applied to soot particles deposited on a filter after probe extraction in the flame. In order to fully characterize the experimental apparatus, a strategy of systematic investigations has been adopted, beginning with the study of less complex systems constituted by model soot (standard polycyclic aromatic hydrocarbons, PAHs, adsorbed on black carbon), and then natural soot sampled from a literature reference ethylene flame. This characterization allowed a good understanding of the analytical response of PAHs to the desorption and ionization processes and the definition of the optimal experimental conditions. The soot PAH content was then investigated on a low-pressure methane/oxygen/nitrogen premixed flat flame ({phi} = 2.32) as a function of the sampling height above the burner (HAB). The obtained mass spectra are reproducible, fragment-free, well resolved in the analyzed m/z range and they are characterized by an excellent signal-to-noise ratio. They all feature regular peak sequences, where each signal peak has been assigned to the most stable high-temperature-formed PAHs. The structure of the mass spectra depends on the sampling HAB into the flame, i.e., on the reaction time. An original contribution to the data interpretation comes from the development of a new sampling method that makes it possible to infer hypotheses about the PAH partition between the gas phase and the soot particles. This method highlights the presence of high-mass PAHs in the soot nucleation zone, and it suggests the importance of heterogeneous reactions occurring between flame PAHs and soot particles. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗