Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

A Comparative Study of Simulated and Measured Main Landing Gear Noise for Large Civil Transports

Computational results for the NASA 26%-scale model of a six-wheel main landing gear with and without a toboggan-shaped noise reduction fairing are presented. The model is a high-fidelity representation of a Boeing 777-200 aircraft main landing gear. A lattice Boltzmann method was used to simulate the unsteady flow around the model in isolation. The computations were conducted in free-air at a Mach number of 0.17, matching a recent acoustic test of the same gear model in the Virginia Tech Stability Wind Tunnel in its anechoic configuration. Results obtained on a set of grids with successively finer spatial resolution demonstrate the challenge in resolving/capturing the flow field for the smaller components of the gear and their associated interactions, and the resulting effects on the high-frequency segment of the farfield noise spectrum. Farfield noise spectra were computed based on an FWH integral approach, with simulated pressures on the model solid surfaces or flow-field data extracted on a set of permeable surfaces enclosing the model as input. Comparison of these spectra with microphone array measurements obtained in the tunnel indicated that, for the present complex gear model, the permeable surfaces provide a more accurate representation of farfield noise, suggesting that volumetric effects are not negligible. The present study also demonstrates that good agreement between simulated and measured farfield noise can be achieved if consistent post-processing is applied to both physical and synthetic pressure records at array microphone locations.

Konig, Benedikt↗

Unstructured CFD Aerodynamic Analysis of a Generic UCAV Configuration

Three independent studies from the United States (NASA), Sweden (FOI), and Australia (DSTO) are analyzed to assess the state of current unstructured-grid computational fluid dynamic tools and practices for predicting the complex static and dynamic aerodynamic and stability characteristics of a generic 53-degree swept, round-leading-edge uninhabited combat air vehicle configuration, called SACCON. NASA exercised the USM3D tetrahedral cell-centered flow solver, while FOI and DSTO applied the FOI/EDGE general-cell vertex-based solver. The authors primarily employ the Reynolds Averaged Navier-Stokes (RANS) assumption, with a limited assessment of the EDGE Detached Eddy Simulation (DES) extension, to explore sensitivities to grids and turbulence models. Correlations with experimental data are provided for force and moments, surface pressure, and off-body flow measurements. The vortical flow field over SACCON proved extremely difficult to model adequately. As a general rule, the prospect of obtaining reasonable correlations of SACCON pitching moment characteristics with the RANS formulation is not promising, even for static cases. Yet, dynamic pitch oscillation results seem to produce a promising characterization of shapes for the lift and pitching moment hysteresis curves. Future studies of this configuration should include more investigation with higher-fidelity turbulence models, such as DES.

Frink, Neal T.↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

Fiber Optic Sensing Technologies for Battery Management Systems and Energy Storage Applications

Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.

25 ENERGY STORAGE↗

State-of-the-art of data collection, analytics, and future needs of transmission utilities worldwide to account for the continuous growth of sensing data

Nowadays, transmission system operators require higher degree of observability in real-time to gain situational awareness and improve the decision-making process to guarantee a safe and reliable operation. Digitalization of energy systems allows utilities to monitor the system dynamic performance in real-time at fast time scales. The use of such technologies has unlocked new opportunities to introduce new data driven algorithms for improving the stability assessment and control of the system. Motivated by these challenges, a group of experts have worked together to highlight and establish a baseline set of these common concerns, which can be used as motivation to propose innovative analytics and data-driven solutions. In this document, the results of a survey on 10 transmission system operators around the world are presented and it aims to understand the current practices of the participating companies, in terms of data acquisition, handling, storage, modelling and analytics. The overall objective of this document is to capture the actual needs from the interviewed utilities, thereby laying the groundwork for setting valid assumptions for the development of advanced algorithms in this field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Dispatchable Virtual Oscillator Control for Decentralized Inverter-Dominated Power Systems: Analysis and Experiments: Preprint

This paper presents an analysis and experimental validation of dispatchable virtual oscillator control (dVOC) for inverter-dominated power systems. dVOC is a promising decentralized control strategy that requires only local measurements to induce grid-forming behavior with programmable droop characteristics. It is dispatchable -- i.e., the inverters can vary their power generation via user-defined power set-points and guarantees strong stability. To verify its feasibility, a testbed comprising multiple dVOC-programmed inverters with transmission line impedances is designed. With an embedded synchronization strategy, the dVOC inverters are capable of dynamic synchronization, black start operation, and transient grid voltage regulation with dynamic load sharing, and real-time-programmable droop characteristics for backward compatibility. All these features are experimentally verified.

14 SOLAR ENERGY↗

Toward Improved Catholyte Materials for Redox Flow Batteries: What Controls Chemical Stability of Persistent Radical Cations?

We report catholyte materials are used to store positive charge in energized fluids circulating through redox flow batteries (RFBs) for electric grid and vehicle applications. Energy-rich radical cations (RCs) are being considered for use as catholyte materials, but to be practically relevant, these RCs (that are typically unstable, reactive species) need to have long lifetimes in liquid electrolytes under the ambient conditions. Only few families of such energetic RCs possess stabilities that are suitable for their use in RFBs; currently, the derivatives of 1,4- dialkoxybenzene look the most promising. In this study, we examine factors that define the chemical and electrochemical stabilities for RCs in this family. To this end, we engineered rigid bis-annulated molecules that by design avoid the two main degradation pathways for such RCs, viz. their deprotonation and radical addition. The decay of the resulting RCs are due to the single remaining reaction: O-dealkylation. We establish the mechanism for this reaction and examine factors controlling its rate. In particular, we demonstrate that this reaction is initiated by the nucleophile attack of the counter anion on the RC partner. The reaction proceeds through the formation of the aroxyl radicals whose secondary reactions yield the corresponding quinones. The O-dealkylation accelerates considerably when the corresponding quinone has poor solubility in the electrolyte, and the rate depends strongly on the solvent polarity. Finally, our mechanistic insights suggest new ways of improving the RC catholytes through molecular engineering and electrolyte optimization.

25 ENERGY STORAGE↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Frequency Response and Congestion Management using Multi-Terminal HVDC Overlay

Continental level power system interconnections using a High Voltage direct current (HVDC) transmission lines have been considered to bring economic benefits such as interregional power exchange. This paper describes the modeling process and studies the technical benefits of having multiple HVDC lines, including a grid of HVDC lines (macrogrid) configuration, connecting the North American Eastern and Western electric power interconnections. The models developed provide steady state and stability analysis for multiple HVDC overlay topologies and provide technical benefit analysis in terms of frequency response and congestions management. The paper also provides a comparison of different HVDC topologies performance and their grid support in case of major disturbances

Tbaileh, Ahmad↗

Voltage stability smart meter for analyzing voltage data and controlling an electrical power source and/or an electric appliance

Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.

Min, Liang↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗

Thin-Film Reliability Trends Toward Improved Stability: Preprint

Long-term, stable performance of photovoltaic (PV) modules will be increasingly important to their successful penetration of the power grid. This paper summarizes more than 150 thin-film and more than 1700 silicon PV degradation rates (Rd) quoted in publications for locations worldwide. Partitioning the literature results by technology and date of installation statistical analysis shows animprovement in degradation rate especially for thin-film technologies in the last decade. A CIGS array deployed at NREL for more than 5 years that appears to be stable supports the literature trends. Indoor and outdoor data indicate undetectable change in performance (0.2+/-0.2 %/yr). One module shows signs of slight degradation from what appears to be an initial manufacturing defect, however ithas not affected the overall system performance.

14 SOLAR ENERGY↗

Enabling Seamless Integration of EV Charging Infrastructure with Weak Electric Grids

Widespread adoption of Electric Vehicles (EVs) for light, medium, and heavy duty (LD, MD, and HD) applications has gained significant interest. Based on ownership and user preferences, LD and local delivery MD EVs are typically connected to grid distribution networks whereas larger MD and HD EVs will be connected to distribution or even sub-transmission networks. Challenges with at-scale EVs and charging infrastructure supporting it include interoperability, distribution network upgrades, demand charges, power quality, voltage stability, etc. Based on real-world data, steady-state and dynamic assessments of LD EV adoption for weak distribution grids is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of the Parareal Algorithm for Acoustic Wave Propagation

We present an application of the parareal algorithm to solve wave propagation problems in the time domain. The parareal algorithm is based on a decomposition of the integration time interval in time slices. It involves a serial prediction step based on a coarse approximation, and a correction step (computed in parallel) based on a fine approximation within each time slice. In our case, the spatial discretization is based on a spectral element approximation which allows flexible and accurate wave simulations in complex geological media. Fully explicit time advancing schemes are classically used for both coarse and fine solvers.In a first stage, we solve the 1D acoustic wave equation in an homogeneous medium in order to test stability and convergence properties of the parareal algorithm. We confirmed the stability problems outlined by Bal and Farhat et al. for hyperbolic problems. These stability issues are mitigated by a time-discontinuous Galerkin discretization of the coarse solver. It may also involve a coarser spatial discretization (hp-refinement) which helps to preserve stability and allows more significant computer savings. Besides, we explore the contribution of elastodynamic homogenization to build consistent coarse grid solvers. Extension to 2D/3D realistic geological media is an ongoing work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Treatment of the polar coordinate singularity in axisymmetric wave propagation using high-order summation-by-parts operators on a staggered grid

In this paper, we develop a high-order finite difference scheme for axisymmetric wave propagation in a cylindrical conduit filled with a viscous fluid. The scheme is provably stable, and overcomes the difficulty of the polar coordinate singularity in the radial component of the diffusion operator. The finite difference approximation satisfies the principle of summation-by-parts (SBP), which is used to establish stability using the energy method. To treat the coordinate singularity without losing the SBP property of the scheme, a staggered grid is introduced and quadrature rules with weights set to zero at the endpoints are considered. Finally, the accuracy of the scheme is studied both for a model problem with periodic boundary conditions at the ends of the conduit and its practical utility is demonstrated by modeling acoustic-gravity waves in a magmatic conduit.

42 ENGINEERING↗