Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Simulated Data for High Temperature Composite Design

The paper describes an effective formal method that can be used to simulate design properties for composites that is inclusive of all the effects that influence those properties. This effective simulation method is integrated computer codes that include composite micromechanics, composite macromechanics, laminate theory, structural analysis, and multi-factor interaction model. Demonstration of the method includes sample examples for static, thermal, and fracture reliability for a unidirectional metal matrix composite as well as rupture strength and fatigue strength for a high temperature super alloy. Typical results obtained for a unidirectional composite show that the thermal properties are more sensitive to internal local damage, the longitudinal properties degrade slowly with temperature, the transverse and shear properties degrade rapidly with temperature as do rupture strength and fatigue strength for super alloys.

Chamis, Christos C.↗

Space-Dynamically Responding Ultrasonic Matrix System

Space-Dynamically Responding Ultrasonic Matrix System (SpaceDRUMS) comprises a suite of hardware that enables containerless processing (samples of experimental materials can be processed without ever touching a container wall). Using a collection of 20 acoustic beam emitters, SpaceDRUMS can completely suspend a baseball-sized solid or liquid sample during combustion or heat-based synthesis. Because the samples never contact the container walls, materials can be produced in microgravity with an unparalleled quality of shape and composition. The ultimate goal of the SpaceDRUMS hardware is to assist with the development of advanced materials of a commercial quantity and quality, using the space-based experiments to guide development of manufacturing processes on Earth. T

Guigne, Jacques↗

Multi-Scale Computational Modeling of Two-Phased Metal Using GMC Method

A multi-scale computational model for determining plastic behavior in two-phased CMSX-4 Ni-based superalloys is developed on a finite element analysis (FEA) framework employing crystal plasticity constitutive model that can capture the microstructural scale stress field. The generalized method of cells (GMC) micromechanics model is used for homogenizing the local field quantities. At first, GMC as stand-alone is validated by analyzing a repeating unit cell (RUC) as a two-phased sample with 72.9% volume fraction of gamma'-precipitate in the gamma-matrix phase and comparing the results with those predicted by finite element analysis (FEA) models incorporating the same crystal plasticity constitutive model. The global stress-strain behavior and the local field quantity distributions predicted by GMC demonstrated good agreement with FEA. High computational saving, at the expense of some accuracy in the components of local tensor field quantities, was obtained with GMC. Finally, the capability of the developed multi-scale model linking FEA and GMC to solve real life sized structures is demonstrated by analyzing an engine disc component and determining the microstructural scale details of the field quantities.

nickel alloys↗

Phosphonium-based ionic liquids and uses

Phosphonium-based room temperature ionic liquids ("RTILs") were prepared. They were used as matrices for Matrix-Assisted Laser Desorption Ionization (MALDI) mass spectrometry and also for preparing samples of dyes for analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Salt-stone Oxidation Study: Leaching Method - 13092

Cementitious waste forms can be designed to chemically stabilize selected contaminants, such as Tc{sup +7} and Cr{sup +6}, by chemically reduction to lower valance states, Tc{sup +4} and Cr{sup +3}, respectively, and precipitation of these species in alkaline media as low solubility solid phases. Data for oxidation of this type of cementitious waste form cured under field conditions as a function of time is required for predicting the performance of the waste form and disposal facility. The rate of oxidation (oxidation front advancement) is an important parameter for predicting performance because the solubilities of some radionuclide contaminants, e.g., technetium, are a function of the oxidation state. A non-radioactive experiment was designed for quantifying the oxidation front advancement using chromium, as an approximate redox-sensitive surrogate (Cr{sup +6} / Cr{sup +3}) for technetium (Tc{sup +7} / Tc{sup +4}). Nonradioactive cementitious waste forms were prepared in the laboratory and cured under both laboratory and 'field conditions'. Laboratory conditions were ambient temperature and sealed sample containers. Field conditions were approximated by curing samples in open containers which were placed inside a plastic container stored outdoors at SRS. The container had a lid and was instrumented with temperature and humidity probes. Sub-samples as thin as 0.2 mm were taken as a function of distance from the exposed surface of the as-cast sample. The sub-samples were leached and the leachates were analyzed for chromium, nitrate, nitrite and sodium. Nitrate, nitrite, and sodium concentrations were used to provide baseline data because these species are not chemically retained in the waste form matrix to any significant extent and are not redox sensitive. 'Effective' oxidation fronts for Cr were measured for samples containing 1000, 500 and 20 mg/kg Cr added as soluble sodium chromate, Na{sub 2}CrO{sub 4}. For a sample cured for 129 days under field conditions, leachable Cr (assumed to be the oxidized form, i.e., Cr{sup +6} was detected in the top 15 to 20 mm of the sample spiked with 1000 mg/kg Cr. Below about 20 mm, the Cr concentrations in leachates were below the detection limit (< 0.010 mg/L) which indicates that the oxidation as the result of exposure to air was limited to the top 20 mm of the sample after exposure for 129 days and that the bulk of the waste form was not affected, i.e., the Cr was stabilized and insoluble. For samples cured in the laboratory, leachable Cr was detected in the top 8 mm of the Cr 1000 sample cured in the laboratory for 37 days. Between 8 and 14 mm, the concentration Cr in the leachate dropped by a factor of about 20 to just above the detection limit. These depth of penetration results indicate that the rate of advancement of the oxidation front for samples spiked with 1000 mg/kg Cr cured under 'field conditions' for 129 days is less than that for the sample cured in the laboratory for 37 days, i.e., 0.156 and 0.216 mm/day, respectively. Additional data are presented for samples spiked with 500 and 20 mg/kg Cr. In summary, cementitious waste forms are porous solids with a network of interconnected pores ranging in diameter from 10 E-10 m to greater than a few mm. The oxidation process is assumed to occur as the result of oxygen transport through the interconnected porosity which may be filled with air, aqueous salt solution, or both. Upon oxidation, the Cr becomes soluble and can be transported in solution through aqueous pore fluid or leachate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610

Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

Oxygen-isotopic Compositions of Low-FeO relicts in High-FeO Host Chondrules in Acfer 094, a Type 3.0 Carbonaceous Chondrite Closely Related to CM

With one exception, the low-FeO relict olivine grains within high-FeO porphyritic chondrules in the type 3.0 Acfer 094 carbonaceous chondrite have DELTA O-17 ( = delta O-17 - 0.52 X delta O-18) values that are substantially more negative than those of the high-FeO olivine host materials. These results are similar to observations made earlier on chondrules in C03.0 chondrites and are consistent with two independent models: (1) Nebular solids evolved from low-FeO, low-DELTA O-17 compositions towards high-FeO, more positive DELTA O-17 compositions; and (2) the range of compositions resulted from the mixing of two independently formed components. The two models predict different trajectories on a DELTA O-17 vs. log Fe/Mg (olivine) diagram, but our sample set has too few values at intermediate Fe/Mg ratios to yield a definitive answer. Published data showing that Acfer 094 has higher volatile contents than CO chondrites suggest a closer link to CM chondrites. This is consistent with the high modal matrix abundance in Acfer 094 (49 vol.%). Acfer 094 may be an unaltered CM chondrite or an exceptionally matrix-rich CO chondrite. Chondrules in Acfer 094 and in CO and CM carbonaceous chondrites appear to sample the same population. Textural differences between Acfer 094 and CM chondrites are largely attributable to the high degree of hydrothermal alteration that the CM chondrites experienced in an asteroidal setting.

Rubin, Alan E.↗

Incorporation of trace metals in Hanford waste boehmite mineral phases and dissolution rate impacts

Abstract Data from radioactive Hanford tank waste samples was analyzed to assess whether trace metals present were incorporated into the bulk boehmite matrix or were simply intermingled with the bulk material and subsequent impacts to the boehmite dissolution rate. Results suggest that chromium is primarily blended into the bulk boehmite, with a small fraction present on the surface of the solids. However, increasing the level of chromium incorporation 30‐fold decreased the dissolution rate of boehmite by only 8%, suggesting incorporation of chromium into these samples had a minimal impact on the dissolution rate. Iron was also found to be incorporated in the boehmite solids. Silicon appears to be simply intermingled and not blended into the boehmite crystals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Micro-Mechanical Constitutive Model to Predict Hygrothermal Aging of Cross-Linked Polymers

Abstract A multi-physics material model is presented to describe the effects of temperature, oxygen, and humidity on the constitutive response of cross-linked polymers. The effect of hygrothermal damage on the mechanical integrity of the polymer matrix can be considered as the result of damage accumulation of two independent aging mechanism namely, i) thermo-oxidative, and ii) hydrolytic aging. In order to capture the mutual effects of thermo-oxidative and hydrolytic aging, an assumption has been made that each of the aging phenomenon can be superposed to each other. In fact, each of them works independently and as a result, they can compete with each other. Utilizing the theory of network decomposition, all phenomena and their correlation were modeled and thus, the strain energy function of the polymer matrix is written with respect to four independent mechanisms, i) the shrinking original matrix that has neither been attacked by water nor oxygen, ii) conversion of the first network to two new network due to the reduction and formation of cross-links, and iii) energy loss from network degradation due to attack of the water molecules to polymer active agents. Moreover, the proposed model is micro-mechanically based and is mainly relevant on thin samples due to our underlying assumption of homogeneous diffusion of oxygen and water throughout the matrix. The model has been validated against extensive data-sets obtained from experiments we specifically designed for concept validation.

Bahrololoumi, Amir↗

DOE/DOT Crude Oil Characterization Research Study, Task 2 Test Report on Evaluating Crude Oil Sampling and Analysis Methods, Revision 1 - Winter Sampling

The Crude Oil Characterization Research Study is designed to evaluate whether crude oils currently transported in North America, including those produced from “tight” formations, exhibit physical or chemical properties that are distinct from conventional crudes, and how these properties associate with combustion hazards that may be realized during transportation and handling. The current report presents results from Task 2, investigating which commercially available methods can accurately and reproducibly collect and analyze crude oils for vapor pressure and composition, including dissolved gases. This issue, Revision 1 – Winter Sampling, incorporates additional seasonal data and compositional analysis results that have become available since publication of a prior report, SAND2017-12482, released in December 2017. Both reports compare performance of commercially available methods to that of a well-established mobile laboratory system that currently serves as the baseline instrument system for the U.S. Strategic Petroleum Reserve Crude Oil Vapor Pressure Program. The experimental matrix evaluates the performance of selected methods for (i) capturing, transporting, and delivering hydrocarbon fluid samples from the field to the analysis laboratory, coupled with (ii) analyzing for properties related to composition and volatility of the oil, including vapor pressure, gas-oil ratio, and dissolved gases and light hydrocarbons. Several combinations of sample capture and analysis were observed to perform well in both summer and winter sampling environments, though conditions apply that need to be considered carefully for given applications. Methods that perform well from Task 2 will then be utilized in subsequent Task 3 (combustion studies) and Task 4 (compositional analyses of multiple crude types), to be addressed in subsequent reports.

02 PETROLEUM↗

Effect of Heat Treatment on Microstructure and Mechanical Properties of Laser Additively Manufactured AISI H13 Tool Steel

The effect of heat treatment on microstructure and mechanical properties (microhardness, wear resistance and impact toughness) of laser additively manufactured AISI H13 tool steel was systemically investigated. To understand the variation of microstructure and mechanical properties under different heat treatments, the as-deposited samples were treated at 350, 450, 550, 600 and 650 °C/2 h, respectively. Microstructure and phase transformation were investigated through optical microscopy, scanning electron microscope and transmission electron microscope. The mechanical properties were characterized by nanoindentation tests, Charpy tests and high-temperature wear tests. The microstructure of as-deposited samples consisted of martensite, ultrafine carbides and retained austenite. After the tempering treatment, the martensite was converted into tempered martensite and some fine alloy carbides which precipitated in the matrix. When treated at 550 °C, the greatest hardness and nanohardness were 600 HV{sub 0.3} and 6119.4 MPa due to many needle-like carbides precipitation. The value of hardness increased firstly and then decreased when increasing the temperature. When tempered temperatures exceeded 550 °C, the carbides became coarse, and martensitic matrix recrystallized at the temperature of 650 °C. The least impact energy was 6.0 J at a temperature of 550 °C. Samples tempered at 550 °C had larger wear volume loss than that of others. Wear resistances of all samples under atmospheric condition at 400 °C showed an oxidation mechanism.

36 MATERIALS SCIENCE↗

Digital approximation of continuous-data control systems by point-by-point state comparison

This paper presents a point-by-point state comparison method of approximating a continuous-data system by a sampled-data system. The problem is to attempt the matching of the states of the two systems at the sampling instants. A partial matching has to be conducted if the systems have more states than controls. A weighting matrix is used to regulate the partial matching and weights placed on each state. The digital approximation is affected by use of forward gain E(T) and feedback gain G(T) in the sampled-data system. It is shown that, in general, these gains can be approximated by truncated Taylor series expansions. An illustrative example is given using the one-axis dynamics of the Skylab satellite.

Kuo, B. C.↗

X-ray tomography investigation of intensive sheared Al–SiC metal matrix composites

X-ray computed tomography (XCT) was used to characterise three dimensional internal structure of Al–SiC metal matrix composites. The alloy composite was prepared by casting method with the application of intensive shearing to uniformly disperse SiC particles in the matrix. Visualisation of SiC clusters as well as porosity distribution were evaluated and compared with non-shearing samples. Results showed that the average particle size as well as agglomerate size is smaller in sheared sample compared to conventional cast samples. Further, it was observed that the volume fraction of porosity was reduced by 50% compared to conventional casting, confirming that the intensive shearing helps in deagglomeration of particle clusters and decrease in porosity of Al–SiC metal matrix composites. - Highlights: • XCT was used to visualise 3D internal structure of Al-SiC MMC. • Al-SiC MMC was prepared by casting with the application of intensive shearing. • SiC particles and porosity distribution were evaluated. • Results show shearing deagglomerates particle clusters and reduces porosity in MMC.

36 MATERIALS SCIENCE↗

Saltstone Oxidation Study: Leaching Method

Cementitious waste forms can be designed to chemically stabilize selected contaminants, such as Tc{sup +7} and Cr{sup +6}, by chemically reduction to lower valance states, Tc{sup +4} and Cr{sup +3}, respectively, and precipitation of these species in alkaline media as low solubility solid phases. Data for oxidation of this type of cementitious waste form cured under field conditions as a function of time is required for predicting the performance of the waste form and disposal facility. The rate of oxidation (oxidation front advancement) is an important parameter for predicting performance because the solubilities of some radionuclide contaminants, e.g., technetium, are a function of the oxidation state. A non-radioactive experiment was designed for quantifying the oxidation front advancement using chromium, as an approximate redox-sensitive surrogate (Cr{sup +6} / Cr{sup +3}) for technetium (Tc{sup +7} / Tc{sup +4}). Nonradioactive cementitious waste forms were prepared in the laboratory and cured under both laboratory and ?field conditions.? Laboratory conditions were ambient temperature and sealed sample containers. Field conditions were approximated by curing samples in open containers which were placed inside a plastic container stored outdoors at SRS. The container had a lid and was instrumented with temperature and humidity probes. Subsamples as thin as 0.2 mm were taken as a function of distance from the exposed surface of the as-cast sample. The subsamples were leached and the leachates were analyzed for chromium, nitrate, nitrite and sodium. Nitrate, nitrite, and sodium concentrations were used to provide baseline data because these species are not chemically retained in the waste form matrix to any significant extent and are not redox sensitive. ?Effective? oxidation fronts for Cr were measured for samples containing 1000, 500 and 20 mg/kg Cr added as soluble sodium chromate, Na{sub 2}CrO{sub 4}. For a sample cured for 129 days under field conditions, leachable Cr (assumed to be the oxidized form, i.e., Cr{sup +6} was detected in the top 15 to 20 mm of the sample spiked with 1000 mg/kg Cr. Below about 20 mm, the Cr concentrations in leachates were below the detection limit (< 0.010 mg/L) which indicates that the oxidation as the result of exposure to air was limited to the top 20 mm of the sample after exposure for 129 days and that the bulk of the waste form was not affected, i.e., the Cr was stabilized and insoluble. For samples cured in the laboratory, leachable Cr was detected in the top 8 mm of the Cr 1000 sample cured in the laboratory for 37 days. Between 8 and 14 mm, the concentration Cr in the leachate dropped by a factor of about 20 to just above the detection limit. These depth of penetration results indicate that the rate of advancement of the oxidation front for samples spiked with 1000 mg/kg Cr cured under ?field conditions? for 129 days is less than that for the sample cured in the laboratory for 37 days, i.e., 0.156 and 0.216 mm/day, respectively. Additional data are presented for samples spiked with 500 and 20 mg/kg Cr. In summary, cementitious waste forms are porous solids with a network of interconnected pores ranging in diameter from 10E-10 m to greater than a few mm. The oxidation process is assumed to occur as the result of oxygen transport through the interconnected porosity which may be filled with air, aqueous salt solution, or both. Upon oxidation, the Cr becomes soluble and can be transported in solution through aqueous pore fluid or leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward Revealing Microcystin Distribution in Mouse Liver Tissue Using MALDI-MS Imaging

Cyanotoxins can be found in water and air during cyanobacterial harmful algal blooms (cHABs) in lakes and rivers. Therefore, it is very important to monitor their potential uptake by animals and humans as well as their health effects and distribution in affected organs. Herein, the distribution of hepatotoxic peptide microcystin-LR (MC-LR) is investigated in liver tissues of mice gavaged with this most common MC congener. Preliminary matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging experiments performed using a non-automated MALDI matrix deposition device and a MALDI-time-of-flight (TOF) mass spectrometer yielded ambiguous results in terms of MC-LR distribution in liver samples obtained from MC-LR-gavaged mice. The tissue preparation for MALDI-MS imaging was improved by using an automated sprayer for matrix deposition, and liver sections were imaged using an Nd:YAG MALDI laser coupled to a 15 Tesla Fourier-transform ion cyclotron resonance (FT-ICR)-mass spectrometer. MALDI-FT-ICR-MS imaging provided unambiguous detection of protonated MC-LR (calculated m/z 995.5560, z = +1) and the sodium adduct of MC-LR (m/z 1017.5380, z = +1) in liver sections from gavaged mice with great mass accuracy and ultra-high mass resolution. Since both covalently bound and free MC-LR can be found in liver of mice exposed to this toxin, the present results indicate that the distribution of free microcystins in tissue sections from affected organs, such as liver, can be monitored with high-resolution MALDI-MS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Expanded Analysis of Hot Isostatic Pressed Iodine-Loaded Silver-Exchanged Mordenite

Reduced silver-exchanged mordenite (Ag0Z) is being evaluated as a potential material to control the release of radioactive iodine that is released during the reprocessing of used nuclear fuel into the plant off-gas streams. The purpose of this study was to determine if hot pressing could directly convert this iodine loaded sorbent into a waste form suitable for long-term disposition. The minimal pretreatment required for production of pressed pellets makes hot pressing a technically and economically desirable process. Initial scoping studies utilized hot uniaxial pressing (HUPing) to prepare samples of non-iodine-loaded reduced silver exchanged mordenite (Ag0Z). The resulting samples were very fragile due to the low pressure (~ 28 MPa) used. It was recommended that hot isostatic pressing (HIPing), performed at higher temperatures and pressures, be investigated. HIPing was carried out in two phases, with a third and final phase currently underway. Phase I evaluated the effects of pressure and temperature conditions on the manufacture of a pressed sample. The base material was an engineered form of silver zeolite. Six samples of Ag0Z and two samples of I-Ag0Z were pressed. It was found that HIPing produced a pressed pellet of high density. Analysis of each pressed pellet by scanning electron microscopy-energy dispersive spectrophotometry (SEM-EDS) and X-ray diffraction (XRD) demonstrated that under the conditions used for pressing, the majority of the material transforms into an amorphous structure. The only crystalline phase observed in the pressed Ag0Z material was SiO2. For the samples loaded with iodine (I-Ag0Z) iodine was present as AgI clusters at low temperatures, and transformed into AgIO4 at high temperatures. Surface mapping and EDS demonstrate segregation between silver iodide phases and silicon dioxide phases. Based on the results of the Phase I study, an expanded test matrix was developed to examine the effects of multiple source materials, compositional variations, and an expanded temperature range. Each sample was analyzed with the approach used in Phase I. In all cases, there is nothing in the SEM or XRD analyses that indicates creation of any AgI-containing silicon phase, with the samples being found to be largely amorphous. Phase III of this study has been initiated and is the final phase of scoping tests. It will expand upon the test matrix completed in Phase II and will examine the durability of the pressed pellets through product consistency testing (PCT) studies. Transformation of the component material into a well-characterized iodine-containing mineral phase would be desirable. This would limit the additional experimental testing and modeling required to determine the long-term stability of the pressed pellet, as much of that information has already been learned for several common iodine-containing minerals. However, this is not an absolute requirement, especially if pellets produced by hot isostatic pressing can be demonstrated through initial PCT studies to retain iodine well despite their amorphous composition.

hot isostatic pressing↗