Search NASA⌕ Search

SEARCH · Search NASA

Results for “multi frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards AI Based Data Classification for Decision Making During Testing

During the development of high-consequence items, test systems should be capable of differentiating between test failures resulting from narrowly missing requirements versus those indicating potentially catastrophic faults. In many instances, classifying the data corresponds to simply identifying whether measured waveforms have approximately the anticipated shape. Cast in this light, the problem reduces to converting raw data into a form optimal for use with neural network classifiers. This manuscript investigates different means of representing raw data for image classification. Raw data plots and Short Time Fourier Transform (STFT) spectrograms are classified by both custom built, small-scale, Convolution Neural Networks (CNN) and open-source, multi-million parameter, pre-trained deep CNNs. In the case of time varying frequency content, the STFTs provide images with greater detail and can be accurately classified with simpler networks. This requires less memory and runs faster than classifying the raw data using the more sophisticated options—making STFTs optimal for applications with memory constraints. STFTs are not a panacea. In some cases the time-domain signal contains useful information that should not be discarded. Rather than using raw data or STFTs, the images can be constructed from both by using red and green channels of an RGB image to visualize the real and imaginary components of the transform, with the raw data occupying the blue channel.

97 MATHEMATICS AND COMPUTING↗

USB noise reduction by nozzle and flap modifications

The development of concepts for reducing upper surface blown flap noise at the source through flap modifications and special nozzles is reviewed. In particular, recent results obtained on the aerodynamic and acoustic performance of flaps with porous surfaces near the trailing edge and multi-slotted nozzles are reviewed. Considerable reduction (6-10 db) of the characteristic low frequency peak is shown. The aerodynamic performance is compared with conventional systems, and prospects for future improvements are discussed.

Hayden, R. E.↗

Flutter analysis using transversality theory

A new method of calculating flutter boundaries of undamped aeronautical structures is presented. The method is an application of the weak transversality theorem used in catastrophe theory. In the first instance, the flutter problem is cast in matrix form using a frequency domain method, leading to an eigenvalue matrix. The characteristic polynomial resulting from this matrix usually has a smooth dependence on the system's parameters. As these parameters change with operating conditions, certain critical values are reached at which flutter sets in. Our approach is to use the transversality theorem in locating such flutter boundaries using this criterion: at a flutter boundary, the characteristic polynomial does not intersect the axis of the abscissa transversally. Formulas for computing the flutter boundaries and flutter frequencies of structures with two degrees of freedom are presented, and extension to multi-degree of freedom systems is indicated. The formulas have obvious applications in, for instance, problems of panel flutter at supersonic Mach numbers.

Afolabi, D.↗

Detection of High-impedance Arcing Faults in Radial Distribution DC Systems

High voltage, low current arcing faults in DC power systems have been researched at the NASA Glenn Research Center in order to develop a method for detecting these 'hidden faults', in-situ, before damage to cables and components from localized heating can occur. A simple arc generator was built and high-speed and low-speed monitoring of the voltage and current waveforms, respectively, has shown that these high impedance faults produce a significant increase in high frequency content in the DC bus voltage and low frequency content in the DC system current. Based on these observations, an algorithm was developed using a high-speed data acquisition system that was able to accurately detect high impedance arcing events induced in a single-line system based on the frequency content of the DC bus voltage or the system current. Next, a multi-line, radial distribution system was researched to see if the arc location could be determined through the voltage information when multiple 'detectors' are present in the system. It was shown that a small, passive LC filter was sufficient to reliably isolate the fault to a single line in a multi-line distribution system. Of course, no modification is necessary if only the current information is used to locate the arc. However, data shows that it might be necessary to monitor both the system current and bus voltage to improve the chances of detecting and locating high impedance arcing faults

Gonzalez, Marcelo C.↗

Differential Resonant Ring YIG Tuned Oscillator

A differential SiGe oscillator circuit uses a resonant ring-oscillator topology in order to electronically tune the oscillator over multi-octave bandwidths. The oscillator s tuning is extremely linear, because the oscillator s frequency depends on the magnetic tuning of a YIG sphere, whose resonant frequency is equal to a fundamental constant times the DC magnetic field. This extremely simple circuit topology uses two coupling loops connecting a differential pair of SiGe bipolar transistors into a feedback configuration using a YIG tuned filter creating a closed-loop ring oscillator. SiGe device technology is used for this oscillator in order to keep the transistor s 1/f noise to an absolute minimum in order to achieve minimum RF phase noise. The single-end resonant ring oscillator currently has an advantage in fewer parts, but when the oscillation frequency is greater than 16 GHz, the package s parasitic behavior couples energy to the sphere and causes holes and poor phase noise performance. This is because the coupling to the YIG is extremely low, so that the oscillator operates at near the unloaded Q. With the differential resonant ring oscillator, the oscillation currents are just in the YIG coupling mechanisms. The phase noise is even better, and the physical size can be reduced to permit monolithic microwave integrated circuit oscillators. This invention is a YIG tuned oscillator circuit making use of a differential topology to simultaneously achieve an extremely broadband electronic tuning range and ultra-low phase noise. As a natural result of its differential circuit topology, all reactive elements, such as tuning stubs, which limit tuning bandwidth by contributing excessive open loop phase shift, have been eliminated. The differential oscillator s open-loop phase shift is associated with completely non-dispersive circuit elements such as the physical angle of the coupling loops, a differential loop crossover, and the high-frequency phase shift of the n-p-n transistors. At the input of the oscillator s feedback loop is a pair of differentially connected n-p-n SiGe transistors that provides extremely high gain, and because they are bulk-effect devices, extremely low 1/f noise (leading to ultralow RF phase noise). The 1/f corner frequency for n-p-n SiGe transistors is approximately 500 Hz. The RF energy from the transistor s collector output is connected directly to the top-coupling loop (the excitation loop) of a single-sphere YIG tuned filter. A uniform magnetic field to bias the YIG must be at a right angle to any vector associated with an RF current in a coupling loop in order for the precession to interact with the RF currents.

Parrott, Ronald A.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. The differential design and multiple signal modulations spanning 11 orders of magnitude in time combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 uK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r <10(exp -3) at 5 standard deviations. In addition, the rich PIXIE data will constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

Kogut, Alan J.↗

The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations

The Primordial Inflation Explorer (PIXIE) is a concept for an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. Rhe proposed instrument can map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10..3 at 5 standard deviations. The rich PIXIE data set can also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.

Kogut, Alan J.↗

Understanding the I/O Performance Gap Between Cori KNL and Haswell

The Cori system at NERSC has two compute partitions with different CPU architectures: a 2,004 node Haswell partition and a 9,688 node KNL partition, which ranked as the 5th most powerful and fastest supercomputer on the November 2016 Top 500 list. The compute partitions share a common storage configuration, and understanding the IO performance gap between them is important, impacting not only to NERSC/LBNL users and other national labs, but also to the relevant hardware vendors and software developers. In this paper, we have analyzed performance of single core and single node IO comprehensively on the Haswell and KNL partitions, and have discovered the major bottlenecks, which include CPU frequencies and memory copy performance. We have also extended our performance tests to multi-node IO and revealed the IO cost difference caused by network latency, buffer size, and communication cost. Overall, we have developed a strong understanding of the IO gap between Haswell and KNL nodes and the lessons learned from this exploration will guide us in designing optimal IO solutions in many-core era.

97 MATHEMATICS AND COMPUTING↗

RF performance sensitivity to tuning of Nb3Sn coated CEBAF cavities

Nb3Sn has the potential to surpass niobium as the material of choice for SRF applications. The potential of this material stems from a larger superconducting energy gap, which leads to expectations of a higher RF critical field and a lower RF surface resistance. The appeal of better superconducting properties is offset by the relative complexity of producing practical Nb3Sn structures, and Nb3Sn sensitivity to lattice disorder challenges the use of the material for practical applications. Such sensitivity is indirectly probed during SRF cavity development, when the cavity is tuned to match the desired accelerator frequency. In the course of recent experiments we have coated and tuned several multi-cell cavities. Cold RF measurements before and after tuning showed degradation in cavity performance after tuning. The results of RF measurement were compared against strain evolution on Nb3Sn surface during tuning based on CST and ANSYS models.

Eremeev, G. V.↗

Multi-User Capacity for Cyclic Prefix Direct Sequence Spread Spectrum with Linear Detection and Precoding

Cyclic Prefix Direct Sequence Spread Spectrum (CP-DSSS) is a promising solution for futuristic 6G ultra-reliable low latency communications (URLLC) and massive machine type communication (mMTC) applications, where the CP-DSSS waveform would operate as a secondary network at the same frequencies as the primary network but at much lower SNR. In this paper, we show per-user capacity for multi-user scenarios, where simple matched filtering (MF) is performed on the uplink (UL) and time-reversal (TR) precoding is used on the downlink (DL). When operating in the low SNR regime, CP-DSSS achieves per-user capacity near the optimum single-user capacity by using a MF detector at the receiver for the UL. TR precoding converges to the optimal capacity as the number of antennas at the hub/gateway increases. Given the near-optimal performance of MF detection and TR precoding for each of the users, CP-DSSS can be implemented with simple device transceiver structures, reducing per-unit cost for massively deployed 6G networks.

5G and Beyond Communications↗

Persistent Acoustic Sensing for Monitoring A Reactor Facility - Oral Presentation

Measurements over the past few years, taking place within the Multi-Informatics for Nuclear Operations Scenarios (MINOS) project, show that infrasound and low-frequency acoustic monitoring can detect, and often quantify, activities that occur on-site at a large research reactor. Observable activities include: crane translation, lifting, and lowering; differentiation between loaded and unloaded crane operations; access door opening and closing; vehicle operations; and cooling tower fan operation. Advanced data analytic and spectral feature extraction methods can be used to interpret selected signatures to reach a deeper understanding of different reactor activities. These measurements are being conducted using a network of smartphones that continuously operate in conjunction with cloud-based architectures. A recent addition to the system is the development and deployment of a real-time, cloud-based analytic framework that supports near-real-time alarming which can facilitate tip-and-cue protocols. This paper will present recent research advances in this area including studies to explore the transferability of learned parameters from one smartphone to another, the detectability of events from multiple sensors at different locations simultaneously, and the feasibility of porting analytical tools directly to the smartphones to allow edge computing with optimized configurations.

42 ENGINEERING↗

Remote Sensing Improves Multi‐Hazard Flooding and Extreme Heat Detection by Fivefold Over Current Estimates

The co‐occurrence of multiple hazards is of growing concern globally as the frequency and magnitude of extreme climate events increases. Despite studies examining the spatial distribution of such events, there has been little work in examining if all relevant life threatening and damaging hazards are captured in existing hazard databases and by common hazard metrics. For example, local/regional flash flooding events are seldom captured by optical satellite instruments and are subsequently excluded from global hazard databases. Similarly, the heat hazard definitions most frequently used in multi‐hazard studies inherently fail to capture events that are life‐threatening but climatologically within an expected range. Our goal is to determine the potential for increasing multi‐hazard event detection capabilities by inferring additional hazard footprints from widely accessible satellite data. We use daily precipitation and temperature satellite data to develop an open‐source framework that infers additional hazard footprints that are not included in traditional methods. With the state of Texas as our study area, we detected 2.5 times as many flood hazards, equivalent to $320 million in property and crop damages. Furthermore, our expanded heat hazard definition increases the impacted area by 56.6%, equivalent to 91.5 million km 2 over an 18 year period. Increasing hazard detection capabilities and expanding existing definitions of hazards using daily satellite data increases the temporal and spatial resolutions at which multi‐hazard events are detected. Having more complete data sets of all relevant hazard extents improves our ability to track global trends and more accurately determine the magnitude of hazard exposure inequities.

equity↗

A guided wave sensor enabling simultaneous wavenumber-frequency analysis for both lamb and shear-horizontal waves

Guided waves in plate-like structures have been widely investigated for structural health monitoring. Lamb waves and shear horizontal (SH) waves, two commonly used types of waves in plates, provide different benefits for the detection of various types of defects and material degradation. However, there are few sensors that can detect both Lamb and SH waves and also resolve their modal content, namely the wavenumber-frequency spectrum. A sensor that can detect both waves is desirable to take full advantage of both types of waves in order to improve sensitivity to different discontinuity geometries. As a result, we demonstrate that polyvinylidene difluoride (PVDF) film provides the basis for a multi-element array sensor that detects both Lamb and SH waves and also measures their modal content, i.e., the wavenumber-frequency spectrum.

36 MATERIALS SCIENCE↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems: Preprint

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different sets of preprocess data for the prediction of the frequency nadir in the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. The training and testing data sets are collected by extensive generation scheduling simulations on the Multi-timescale Integrated Dynamic and Scheduling (MIDAS) toolbox. Numerical results show that all five machine learning methods can achieve high performance accuracy for power system nadir frequency estimation. Among them, the gradient boosting and the XGBoost are clear winners by providing the best prediction accuracy.

data driven↗

A Qualitative Review of Selected Infrared Flow Visualization Processing Techniques: Contrast Enhancement and Frequency Domain Analysis

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel test environment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is introduced as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity. This method merges frequency domain analysis with contrast enhancement and has the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Infrared Imaging↗

Wireless and chip-less passive radiation sensors for high dose monitoring

The safety of nuclear infrastructures may involve the monitoring of many parameters in harsh environments (high radiation level, high temperature, high pressure,..). If technological solutions exist for transducers part in such environments, the electronic part used in reader is not appropriate and still a challenging task. Well-known solutions to remove the electronic part from the harsh environment consist of connecting the transducer and the reader by long electrical wires or performing ex situ remote sensing. However wires may practically be difficult to implement while ex situ measurements are not compatible with on line monitoring. Wireless and passive sensors working in harsh environments could be an appropriate solution for the remote sensing of critical parameters. Passive sensors without electronics in the sensing unit are available (e.g., SAW sensors) but they suffer from short reading range (typically lower than 10 meters). In order to overcome this range limitation a new class of electromagnetic transducers was developed in the mid-2000's. The operating principle is based on the modification of the properties of high-frequency (>> 1 GHz) passive electromagnetic devices by the quantity to be measured. Based on this principle a wide range of sensing properties can be addressed and a large number of materials can be chosen. Moreover the use of high frequency allows reducing the size of the sensor elements (antenna, transducer) and enhancing the immunity to multi-path. Several principles of RF transducers have been already validated by LAAS-CNRS (e;g; pressure, temperature, stress) as well as radar-based solution for the wireless long-range sensors interrogation. The sensor dosimeter exploit here the known property of Hydrogen-Pressure Dosimeters (HPD) for which the polymer material dehydrogenates under nuclear irradiation. The transducer principle is described. The irradiation will generate the out-gazing (hydrogen) of the polymer inside a micro-chamber. The resulting overpressure leads to the deflection of a silicon membrane which modifies the resonant frequency of the RF resonator. Tests structures have been designed in order to quantify the HDPE out-gazing inside a micro-cavity by measuring the deflection of a boss silicon membrane with a mechanical profiler. A specific set up using interferometry method has been also developed to evaluate the pressure generated inside the micro-cavity. The procedure consists in applying a pressure that pushes the membrane to recover a flat membrane. This condition is monitored thanks to the extinction of the Newton rings. Irradiations have been performed up to 30 kGy using 6 MeV focused e-beam providing by electron accelerator. Membrane deflection and generated pressure around 0.2 μm/mg{sub HDPE}/kGy and 70 mbar/mg{sub HDPE}/kGy has been obtained for a 70 μm thick membrane. In order to characterize the hermetic sealing of the micro-chamber under hydrogen over-pressure, membrane deflection after irradiation has been recorded during 50 days. The variations of membrane deflection are randomly distributed and generally lower than ±5%, showing a good hermeticity during this period. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗