Search NASA⌕ Search

SEARCH · Search NASA

Results for “multimode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were used in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.

60 APPLIED LIFE SCIENCES↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

A Comparison of Closures for Stochastic Advection-Dispersion

Perturbation-based moment equations for advection-dispersion equations with random advection have been shown to produce physically unrealistic multimodality. Despite similarities, macrodispersion theory applied to advection-dispersion equations produces moments that do not exhibit such multimodal behavior. This is because macrodispersion approximations, whether explicitly or implicitly, involve renormalized perturbations that remove secularity by including select higher-order terms. We consider basic differences between the two approaches using a low-order macrodispersion approximation to clarify why one produces physically meaningful behavior while the other does not. We demonstrate that using a conventional asymptotic expansion (in the order of velocity fluctuations) leads to equations that cannot produce physically meaningful (macro)dispersion, whether applied to moment equations or macrodispersion theory, proving that the resulting moment equations are in fact hyperbolic in one spatial dimension. We identify higher-order terms that must be added to the conventional expansion to recover second- and fourth-order macrodispersivity approximations. Finally, we propose a closed-form approximation to two-point covariance as a measure of uncertainty, in a manner consistent with the derivation of macrodispersivity. We demonstrate that this and all the macrodispersion-based approximations to moments are more accurate than the alternatives for an example of transport in stratified random media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Xi-CAM v1.2.3

Xi-CAM aims to provide a community driven platform for multimodal analysis in synchrotron science. The platform core provides a robust plugin infrastructure for extensibility, allowing continuing development to simply add further functionality. Current modules include tools for characterization with (GI)SAXS, Tomography, and XAS. This will continue to serve as a development base as algorithms for multimodal analysis develop. Seamless remote data access, visualization and analysis are key elements of Xi-CAM, and will become critical to synchrotron data infrastructure as expectations for future data volume and acquisition rates rise with continuously increasing throughputs. The highly interactive design elements of Xi-cam will similarly support a generation of users which depend on immediate data quality feedback during high-throughput or burst acquisition modes.

Pandolfi, Ronald↗

Solving multiphysics-based inverse problems with learned surrogates and constraints

Abstract Solving multiphysics-based inverse problems for geological carbon storage monitoring can be challenging when multimodal time-lapse data are expensive to collect and costly to simulate numerically. We overcome these challenges by combining computationally cheap learned surrogates with learned constraints. Not only does this combination lead to vastly improved inversions for the important fluid-flow property, permeability, it also provides a natural platform for inverting multimodal data including well measurements and active-source time-lapse seismic data. By adding a learned constraint, we arrive at a computationally feasible inversion approach that remains accurate. This is accomplished by including a trained deep neural network, known as a normalizing flow, which forces the model iterates to remain in-distribution, thereby safeguarding the accuracy of trained Fourier neural operators that act as surrogates for the computationally expensive multiphase flow simulations involving partial differential equation solves. By means of carefully selected experiments, centered around the problem of geological carbon storage, we demonstrate the efficacy of the proposed constrained optimization method on two different data modalities, namely time-lapse well and time-lapse seismic data. While permeability inversions from both these two modalities have their pluses and minuses, their joint inversion benefits from either, yielding valuable superior permeability inversions and CO 2 plume predictions near, and far away, from the monitoring wells.

Yin, Ziyi (ORCID:0000000250248771)↗

High power chip-scale laser

The lack of high-power integrated lasers has been limiting silicon photonics. Despite much progress in chip-scale laser integration, power output remains below levels required for key applications due to low energy efficiency at high pumping currents. Here we break this power limitation by coupling a broad-area multimode gain chip to a silicon-nitride ring resonator and single-mode filter. The resulting optical feedback causes the multimode-gain chip to concentrate its power into a single highly coherent mode. Our device produces more than 150 mW of power and 400 kHz linewidth. We achieve these metrics while maintaining a small footprint of 3 mm 2 .

Antman, Yair↗

Highly cascaded first-order sapphire optical fiber Bragg gratings fabricated by a femtosecond laser

This Letter reports an innovative technique for fabricating large-scale, highly cascaded first-order sapphire optical fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method. For the first time, to the best of our knowledge, this study successfully demonstrates a distributed array of 10 FBGs within highly multimode sapphire crystal fiber, made possible by employing a high-power laser technique to generate larger reflectors with a Gaussian intensity profile. These first-order FBGs offer advantages such as enhanced reflectivity, shorter fabrication time, and simplified spectral characteristics, making them easier to interpret compared with high-order FBGs. The FBGs’ resilience and effectiveness are analyzed by subjecting them to temperature tests, proving their capacity for accurate temperature monitoring up to 1500°C—a testament to their suitability for harsh environments. This novel approach broadens the scope for sensing and communication applications in sapphire fibers, particularly under challenging conditions. The novelty of our work lies in successfully overcoming the limitations of previous designs by integrating a cascade of 10 FBGs in sapphire fibers, thereby enhancing multiplexing capabilities, minimizing overlapping of FBG peaks, and ensuring reliable temperature monitoring in industries and applications with thermal gradients.

47 OTHER INSTRUMENTATION↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study

# 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction Study The 2023 University of Puerto Rico at Mayagüez National Institute for Congestion Reduction (NCIR) Study provided insight into the travel patterns and associated energy consumption of participants. Study results helped researchers identify opportunities for the development of policies that could incentivize the use of alternative modes of travel such as transit and micromobility. Such travel modes reduce congestion by reducing the miles traveled by privately owned vehicles in urban and rural areas. The [National Institute for Congestion Reduction](https://nicr.usf.edu/) provides multimodal congestion reduction strategies through real-world deployments that leverage advances in technology, big data science, and innovative transportation options to optimize the efficiency and reliability of the transportation system for all users. ## Data Collection Agency The University of Puerto Rico at Mayagüez conducted the study. ## Survey Methodology The study was conducted in Spanish. Data collection was enabled via the open-source [NREL OpenPATH platform](https://www.nrel.gov/transportation/openpath). The resulting dataset consists of partially automated travel diaries—combining sensed and surveyed data reflecting patterns of multimodal, end-to-end, individual human mobility—as well as demographic and socioeconomic information from the 17 participants. ## Survey Records, Data, and Documentation Study records include 17 participants. The total number of trips was 458 and total non-air-miles traveled was approximately 1,469.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗