Search NASA⌕ Search

SEARCH · Search NASA

Results for “procurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Energy Storage Policy Summaries for the Global Energy Storage Database

This report includes energy storage policy analysis from six states: Arizona, California, Massachusetts, Nevada, New Mexico, and New York. These summaries offer prototypes for summaries that will subsequently be prepared for all 50 states (and territories). There is presently a shortage of comprehensive energy storage policy analysis that public utility regulators can call upon to inform policymaking in their own jurisdictions. The state policy summaries that will be offered publicly on the Global Energy Storage Database (GESDB) will include analysis on the executive directives, legislation, regulations pertaining to energy storage that have been adopted by an individual state, along with perspective on the remaining policy issues pertaining to storage that a state will be likely to address in the future. It is anticipated that public utility regulators in particular will find the database to be a useful resource in benchmarking policy approaches critical to the continued development of an energy storage marketplace in the U.S., including policy approaches specific to storage and renewables procurement targets, interconnection standards, valuation of energy storage, rate reform and tariff design specific to energy storage, consideration of multiple uses for storage at the distribution level, and potential revisions to existing state net metering programs to accommodate an expected growth of energy storage technologies.

25 ENERGY STORAGE↗

TRP Cutter Head Improvement

The current Target Rod Preparation (TRP) Cutter Head suffers from overheating problems during TPBAR breaching operations. The overheating leads to work stoppage due to the periodic need to allow the TRP Cutter Head motor to cool. This work stoppage and allowance for cooldown of the motor leads to a very inefficient TPBAR breaching process. Due to the increased need for Tritium gas, the system must be improved to increase the efficiency of the TPBAR breaching process. The project would include the following major steps: Determine likely causes of overheating of the TRP cutter head motor. Identify and research methods for cooling currently installed motor. Identify and research alternate motors for TRP cutter head. Procure a new motor for testing. Perform TPBAR breaching mockup testing with new motor. Write report on results and recommendations on potential path forward.

42 ENGINEERING↗

Magnetic Tuning of a Quasi-Periodic Elliptically Polarized Undulator

A 2.8 m long quasi-periodic APPLE II type (Advanced Planar Polarized Light Emitter II) undulator, is being commissioned at National Synchrotron Light Source II (NSLS-II). It will service the Electron SpectroMicroscopy (ESM) beamline in the framework of the NEXT (NSLS-II Experimental Tools) project [1]. It has been designated to provide high brilliance photon beams with variable polarization from VUV to soft X-Rays. Although this EPU (Elliptically Polarizing Undulator) was procured as a turn-key device from Kyma [2], the vendor was only responsible for the mechanical frame and the control system. Sorting and assembly of the magnet modules and the magnetic field tuning - Shimming and Magic Finger- were performed at the NSLS-II Magnetic Measurement Lab. In this report the field optimization techniques implemented in-house to correct the undesirable phasedependent errors and the final results of the magnetic tuning will be described together with the spectral performance of the device.

36 MATERIALS SCIENCE↗

Testing and evaluation of the Sandia Smart Pre-concentrator using a vapor generation system

Sandia National Laboratories (SNL) was contracted by the Defense Threat Reduction Agency (DTRA), through KBRwyle to perform testing and evaluation of the SNL Smart Pre-concentrator (SPC) system and a COTS FTIR system procured by DTRA through KBRwyle. Two common chemical warfare agent simulants, dimethyl methylphosphonate and triethyl phosphate were selected as the compounds of interest. SNL tested both systems using a COTS vapor generation system, capable of delivering known concentrations of specific chemical compounds to both detection systems, with Sandia responsible for the SPC system. Both systems were measured against COTS sorbent collection tubes analyzed by SNL via a laboratory GCMS system. Concentrations measured from tubes upstream from the FTIR system differed from the expected concentrations, while downstream tubes were mostly within 20% of the target concentration.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Transforming the Uranium Fuel Cycle: Safe & Economical Conversion of DUF 6 to DUF 4 [Slides]

Project Outcomes: Designed and fabricated SS reaction vessels for executing reactions with UF 6 at SIGMA, followed by transport and analysis at TA-48; Established a new capability at SIGMA for performing small mass transfers of UF 6 ; Safety documentation approved for performing new UF 6 chemistry at SIGMA; Staff training and conversion opportunity established for LANL Seaborg post-doc; Neat reaction with HMDS (CH 3 ) 3 Si-Si(CH 3 ) 3 produced fluorosilanes; In reactions with solvents, fluorination observed. No DUF 4 observed yet. Observations: Only 4 reactions were completed – more clearly needed; Due to problems with procurement, we did not get the mass control flow (MFC) unit until late August; Due to staff and time shortages UF 4 was never delivered from SIGMA to TA-48 by SHIP-IT; Established ability for future collaboration between C and Sigma.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RoCE: Promising Technology for Ethernet as a High Performance Networking Fabric

Remote Direct Memory Access (RDMA) over Converged Ethernet (RoCE) has the potential to provide performance that rivals traditional high performance fabrics. If this potential proves out, significant impacts on system procurement decisions could follow. This work provides a series of small scale performance results which are used to compare and contrast the performance of RoCE-enabled Ethernet with TCP-based Ethernet and an HPC network. Additionally, a discussion of the maturity of RoCE firmware/software stacks and documentation is provided along with useful approaches for probing performance. A detailed description of two experimental setups known to have good RoCE performance is given, including step-by-step configuration and the exact hardware and software revisions employed. At small scales, RoCE is found to have significant performance advantages over "out-of-the-box" TCP protocols and is competitive with state-of-the-art high performance networks. Further examination of RoCE using a wider array of benchmarks and at greater scale is warranted.

97 MATHEMATICS AND COMPUTING↗

Energy Storage Technology and Cost Characterization Report

This report defines and evaluates cost and performance parameters of six battery energy storage technologies (BESS) (lithium-ion batteries, lead-acid batteries, redox flow batteries, sodium-sulfur batteries, sodium metal halide batteries, and zinc-hybrid cathode batteries) and four non-BESS storage technologies (pumped storage hydropower, flywheels, compressed air energy storage, and ultracapacitors). Data for combustion turbines are also presented. Cost information was procured for the most recent year for which data were available based on an extensive literature review, conversations with vendors and stakeholders, and summaries of actual costs provided from specific projects at sites across the United States. Detailed cost and performance estimates were presented for 2018 and projected out to 2025.

25 ENERGY STORAGE↗

Time-Sensitive Value of Efficiency: Use Cases in Electricity Sector Planning and Programs

Most energy efficiency measures produce energy savings that vary over the course of a year. The value of the hourly electricity savings also varies over the course of a year because the cost of generating, transmitting and distributing electricity during peak demand periods may be significantly higher than during off-peak, or lower load, hours. But many planning and program activities across the United States are missing this important element. A variety of trends are changing the electricity system, including increased adoption of other distributed energy resources, electrification of buildings and vehicles, and relative costs for natural gas-fired and renewable energy generation. Knowing when energy efficiency occurs and the value of the energy or demand savings to the electricity system—the time-sensitive value of efficiency—provides public utility commissions, utilities and other decision makers with key information needed to procure the optimal amount of energy efficiency for their system. The report begins with a discussion of our approach to determining use cases and examples, and then examines the need for time-sensitive efficiency data. Next, it examines five use cases in which states, independent system operators/regional transmission operators (ISOs/RTOs), utilities, and efficiency program administrators consider the TSV-EE: (1) energy efficiency program planning and evaluation, (2) distribution system planning, (3) electricity resource planning (4) electricity rate design, and (5) state and local government activities. The report concludes with areas for future research on the time-sensitive value of efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost of Saving Electricity Through Efficiency Programs Funded by Customers of Publicly Owned Utilities: 2012–2017

This report finds that energy efficiency programs for customers of publicly owned utilities saved electricity at an average cost of 2.4 cents per kilowatt-hour (kWh) from 2012 to 2017. Utilities use such cost performance metrics to assess effectiveness of efficiency program portfolios, determine what programs to offer customers, and, more broadly, ensure electricity system reliability at the most affordable cost as part of electric utility resource adequacy planning and resource procurement processes. The study analyzed efficiency program data reported by 111 program administrators for 219 publicly owned utilities in 14 states — about 90 percent of the municipal utilities and public utility districts that report the data to the Energy Information Administration (EIA). The data represent 88 percent of all spending and 75 percent of all savings that publicly owned utilities reported to EIA in those years. Berkeley Lab used data from several sources, including data provided directly by American Public Power Association members, publicly available annual reports and regional data collections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Report on Level Sensor Development

This report details the development of sensors capable of measuring the level of liquid sodium at the Mechanisms Engineering Test Loop (METL) of Argonne National Laboratory. A differential pressure level sensor and variations of a mutually inductive level sensor have been designed, built, and tested in sodium at METL. A differential pressure level sensor was successfully calibrated during the initial dump tank sodium fill and continues to operate effectively. A differential pressure level sensor has been procured for use in the expansion tank. Three variations of mutually inductive level sensors have been designed, built, and tested in an out-of-sodium testing station in Building 308. The most advanced variation consists of a coil wound mineral insulated cable capable of continuous level measurement of liquid sodium up to 538°C over a range of 70”. Successful in-sodium testing occurred in late 2018.

47 OTHER INSTRUMENTATION↗

2018 Energy Storage Pricing Survey

Since grid energy storage is still a nascent industry, it is often difficult to obtain capital costs for various energy storage technologies. This type of information is required to perform an initial cost-benefit analysis related to a potential energy storage deployment, as well as to compare different energy storage technology options. The goal of this report is to summarize energy storage capital costs that were obtained from industry pricing surveys. The methodology breaks down the cost of an energy storage system into the following categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. Pricing data is presented for the following technologies: pumped hydro storage; compressed air energy storage; sodium battery storage; zinc battery storage; long duration flywheels; short duration flywheels; vanadium flow batteries; zinc bromide flow batteries; iron flow batteries; nickel batteries; lithium ion energy batteries; lithium ion power batteries; lead acid batteries; and advanced lead carbon batteries.

25 ENERGY STORAGE↗

Characterization of vacuum conductance in commercially available (sintered) and additively manufactured porous structures

This report documents the work performed in characterizing the vacuum conductance of porous structures made by conventional sintering (purchased as commercially available products from Mott Corporation ranging from 20 to 100 media grade) and additive manufacturing (powder bed fusion). The additively manufactured structures described in this report were originally intended to be the first iteration of several in an effort to produce desirable conductance characteristics. While resources were not available to link the experimental results to a modeling effort to better understand why certain characteristics were observed, the author hopes that this report may provide a useful set of data for future use, especially as sintered porous structures are not uncommonly procured from Mott corporation for research and development purposes. For that reason, all of the raw data is tabulated in the Appendix: it is possible to reproduce all of the figures shown in this report independently. For a quick order-of magnitude scan of the conductances, refer to Figures 5, 6, 8 and 9.

36 MATERIALS SCIENCE↗

2019 accomplishments: degradation of mechanical properties in structural metals and welds for FTS reservoirs

This report documents work in 2019 at SRNL in support of the Aging and Lifetimes program. Specimens for fracture toughness testing were prepared in prior years by thermally pre-charging samples, provided by Sandia National Laboratories, of welded types 304L and 21-6-9 stainless steels. These samples were pre-charged in 2017. The fracture toughness of the first aged specimens was measured and compared to historical data. The measurements of the 304L and 21-6-9 weld and particularly HAZ represent some of the first fracture data relevant to modern GTS reservoirs. This work represents an on-going collaboration between SRNL and SNL to understand tritium embrittlement of structural metals in Gas Transfer System reservoirs which informs lifetime assessments. Continued testing was conducted on ongoing historical studies, including the effects of very long-term aging, and the relative performance of differently forged stockpile relevant 304L and 316L samples. New samples were pre-charged with tritium and placed in a freezer for an aging study to allow helium to build into the material. The precharged samples consist of smooth and notched tensile samples of 304L stainless steel, as well as tube tensile samples of different thermal treatments supplied by Sandia National Laboratories. Their charging marks the beginning of a new sequence of studies to explore fundamental deformation mechanisms underpinning tritium embrittlement. At predesignated times, samples will be removed from aging and tested to provide data which will help develop an understanding of material degradation with increasing aging time. Also documented is progress in employing various advanced characterization techniques including high resolution electron microscopy, thermally programed desorption, and small angle x-ray scattering, as well as facilities renovations and equipment procurements in support of sustained tritium impacts on materials program at SRNL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

V28 Test Report

The V28 containment vessel was procured by the US Army Recovered Chemical Material Directorate (RCMD) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the fourth EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT- equivalent for up to 637 detonations. This report documents the results of explosive tests that were done on the vessel at Sandia National Laboratories in Albuquerque New Mexico to qualify the vessel for explosive use. The primary qualification test consisted of six, 1.5 pounds charges of Composition C-4 (equivalent to 11.25 pounds TNT) distributed around the vessel in accordance with the User Design Specification. This test was repeated due to a lack of proper clamp settings. Two additional tests using less explosive were performed, one identical in configuration to a test performed in the V27 qualification series as a baseline for comparison, and one where the separation distance of the charges was increased to extend the V27 analysis of distributed load effects on the P2 vessel. All vessel acceptance criteria were met.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Washington Clean Energy Fund: Energy Storage System Consolidated Performance Test Results

This report provides an overview of test results for four energy storage systems funded under the Washington Clean Energy Fund deployed at three utilities in Washington State. Integration of energy storage into the U.S. grid has been gathering momentum across the industry, especially as penetration of power generated by renewable resources increases. Several states have storage procurement targets to deal with a variety of issues, such as afternoon total system load ramping requirements, frequency regulation/control, and integration power generated from by renewable resources. This report presents the performance test results for battery energy storage systems (BESS) funded by the Washington Clean Energy Fund (CEF) 1 Program ($\$$14.3 million in state funding supporting a total investment of $\$$43 million). For each project, the technical attributes of the BESS were tested, defined, and evaluated in detail. These projects were funded jointly by Avista, the Snohomish Public Utility District (SnoPUD), Puget Sound Energy (PSE), the Washington CEF, and the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Will Solar Panels Help When the Power Goes Out? Planning for PV Resilience

PV systems, like all energy systems, must chart a difficult course in order to improve resilience. They need to simultaneously withstand extreme conditions that cause grid power disruptions, be configured in a way that allows electricity to be delivered to meet the PV user's needs, and overcome disruptions arising from solar resource intermittency. Certain considerations reveal themselves as key to a PV system's resilience benefits. Choice of hardware is critical, as is site selection for the PV array. Voluminous evidence in a hurricane context demonstrates that durable hardware, properly maintained and sited, leads to PV systems surviving extreme weather with their functionality intact. Structurally weak or poorly maintained PV equipment, on the other hand, has demonstrated failures during extreme weather events. PV system stakeholders should ensure that best practices are followed for hardware procurement and siting. It is also important to understand that PV systems are not one-size-fits-all. While incorporating islanding capabilities and energy storage into the system's electrical topology will typically enhance resilience, the user's needs will determine the optimally resilient conformation of any given system. These factors - appropriate hardware, siting, maintenance, and system design - are the primary drivers of PV resilience. PV systems possess high potential for resilient energy generation due to their distributed, abundant, and free fuel supply, but the technology itself does not inherently lead to resilient outcomes. Realizing PV's potential for resilience requires consideration of these determinative factors.

14 SOLAR ENERGY↗