Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

Capture and X-ray diffraction studies of protein microcrystals in a microfluidic trap array

A microfluidic platform has been developed for the capture and X-ray analysis of protein microcrystals, affording a means to improve the efficiency of XFEL and synchrotron experiments. X-ray free-electron lasers (XFELs) promise to enable the collection of interpretable diffraction data from samples that are refractory to data collection at synchrotron sources. At present, however, more efficient sample-delivery methods that minimize the consumption of microcrystalline material are needed to allow the application of XFEL sources to a wide range of challenging structural targets of biological importance. Here, a microfluidic chip is presented in which microcrystals can be captured at fixed, addressable points in a trap array from a small volume (<10 µl) of a pre-existing slurry grown off-chip. The device can be mounted on a standard goniostat for conducting diffraction experiments at room temperature without the need for flash-cooling. Proof-of-principle tests with a model system (hen egg-white lysozyme) demonstrated the high efficiency of the microfluidic approach for crystal harvesting, permitting the collection of sufficient data from only 265 single-crystal still images to permit determination and refinement of the structure of the protein. This work shows that microfluidic capture devices can be readily used to facilitate data collection from protein microcrystals grown in traditional laboratory formats, enabling analysis when cryopreservation is problematic or when only small numbers of crystals are available. Such microfluidic capture devices may also be useful for data collection at synchrotron sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples

We investigated a high-precision optical method for measuring the thickness of biological samples regardless of their transparency. The method is based on the precise measurement of optical path length difference of the end surfaces of objects, using a dual-arm axial-scanning low-coherence interferometer. This removes any consideration of the shape, thickness, or transparency of testing objects when performing the measurement. Scanning the reference simplifies the measurement setup, resulting in unambiguous measurement. Using a 1310 nm wavelength superluminescent diode, with a 65 nm bandwidth, the measurement accuracy was as high as 11.6 {mu}m. We tested the method by measuring the thickness of both transparent samples and nontransparent soft biological tissues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Method of Adrenal Venous Sampling via an Antecubital Approach

PurposeCurrently, almost all adrenal venous sampling (AVS) procedures are performed by femoral vein access. The purpose of this study was to establish the technique of AVS via an antecubital approach and evaluate its safety and feasibility.Materials and MethodsFrom January 2012 to June 2015, 194 consecutive patients diagnosed as primary aldosteronism underwent AVS via an antecubital approach without ACTH simulation. Catheters used for bilateral adrenal cannulations were recorded. The success rate of bilateral adrenal sampling, operation time, fluoroscopy time, dosage of contrast, and incidence of complications were calculated.ResultsA 5F MPA1 catheter was first used to attempt right adrenal cannulation in all patients. Cannulation of the right adrenal vein was successfully performed in 164 (84.5%) patients. The 5F JR5, Cobra2, and TIG catheters were the ultimate catheters for right adrenal cannulation in 16 (8.2%), 5 (2.6%), and 9 (4.6%) patients, respectively. For left adrenal cannulation, JR5 and Cobra2 catheters were used in 19 (9.8%) and 10 (5.2%) patients, respectively, while only TIG catheters were used in the remaining 165 (85.1%) patients. The rate of successful adrenal sampling on the right, left, and bilateral sides was 91.8%, 93.3%, and 87.6%, respectively. The mean time of operation was (16.3 ± 4.3) minutes, mean fluoroscopy time was (4.7 ± 1.3) minutes, and the mean use of contrast was (14.3 ± 4.7) ml. The incidence of adrenal hematoma was 1.0%.ConclusionsThis study showed that AVS via an antecubital approach was safe and feasible, with a high rate of successful sampling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature dependent Raman scattering in YCrO{sub 3}

High quality polycrystalline YCrO{sub 3} samples were synthesized using solid-state-reaction method. The samples were subsequently characterized using X-ray diffraction and magnetometry. Further, temperature dependent Raman spectroscopy over a spectral range from 100 to 800 cm{sup −1} was used to examine the variation of phonons as a function of temperature from 90 to 300 K. In the low temperature ferroelectric phase of YCrO{sub 3}, the observed phonon spectra showed softening of some Raman modes below the magnetic ordering temperature (T{sub N} ∼ 142K), suggesting a coupling between the spin and phonon degrees of freedom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear optical characterization of ZnS thin film synthesized by chemical spray pyrolysis method

ZnS thin film was prepared by Chemical Spray Pyrolysis (CSP) method. The sample was characterized by X-ray diffraction method and Z scan technique. XRD pattern showed that ZnS thin film has hexagonal structure with an average size of about 5.6nm. The nonlinear optical properties of ZnS thin film was studied by open aperture Z-Scan technique using Q-switched Nd-Yag Laser at 532nm. The Z-scan plot showed that the investigated ZnS thin film has saturable absorption behavior. The nonlinear absorption coefficient and saturation intensity were also estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Allocation and Operation of A Hydropneumatic Energy Storage with Building Microgrid

Behind-meter application for a recently invented hydropneumatic Ground-Level Integrated Diverse Energy Storage (GLIDES) is focused in this research. Considering possible uncertainties from solar radiation and electricity load in a building microgrid, two-stage stochastic programming is adopted for 15-min operation and a mixed-integer nonlinear stochastic model is built with integrated energy systems of GLIDES, solar panel and power generating unit. In order to make the model computationally tractable, we use sample average approximate method to decrease associated complexity with sample size and improve solving efficiency. The experimental results in deterministic and stochastic operation indicate that best candidate solution from SAA are superior to the solution from expected value problem in terms of optimality gap and variance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Apollo 16 special samples, part B

Information is presented concerning special samples which were collected for specific investigations. The methods of sample collection are described along with fillet and core samples.

Hoerz, F.↗

Numerical Methods for Classical Sampled-System Analysis

SAMSAN provides control-system analyst with self-consistent computer algorithms that support large-order control-system design and evaluation studies. Emphasizes sampled-system analysis. SAMSAN reduces burden on analyst by providing set of algorithms well tested and documented and readily integrated for solving control-system problems.

Frisch, H. P.↗

Q-Spectroscopy

A new tool for rapid single-particle analysis in safeguards is described. This quantitative analysis tool has advantages over conventional methods for isotopic analysis of actinide-bearing samples. The method can be used to determine chemical age via 241 Am/ 241 Pu ''atomic clock''.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for high-throughput micro-sampling analysis of electrochemical process salts

A method and apparatus for analyzing molten salt electrolyte. The method includes extracting a sample of a molten salt electrolyte from an electrorefiner or other process vessel or conduit; generating droplets from the sample, where the droplets are at a first temperature; transporting the droplets to detectors, where during transport, the droplets attain a second temperature that is lower than the first temperature; analyzing the droplets at or below the second temperature; and returning the droplets to the process. The apparatus includes a droplet generator; a sample transport mechanism; and at least one detector positioned above the sample transport mechanism.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optical method for the characterization of laterally patterned samples in integrated circuits

Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

47 OTHER INSTRUMENTATION↗

Surge Block Method for Controlling Well Clogging and Sampling Sediment during Bioremediation

A surge block treatment method (i.e. inserting a solid rod plunger with a flat seal that closely fits the casing interior into a well and stocking it up and down) was performed for the rehabilitation of wells clogged with biomass and for the collection of time series sediment samples during in situ bioremediation tests for U(VI) immobilization at a the U.S. Department of Energy site in Oak Ridge, TN. The clogging caused by biomass growth had been controlled by using routine surge block treatment for18 times over a nearly four year test period. The treatment frequency was dependent of the dosage of electron donor injection and microbial community developed in the subsurface. Hydraulic tests showed that the apparent aquifer transmissivity at a clogged well with an inner diameter (ID) of 10.16 cm was increased by 8 13 times after the rehabilitation, indicating the effectiveness of the rehabilitation. Simultaneously with the rehabilitation, the surge block method was successfully used for collecting time series sediment samples composed of fine particles (clay and silt) from wells with ID 1.9 10.16 cm for the analysis of mineralogical and geochemical composition and microbial community during the same period. Our results demonstrated that the surge block method provided a cost-effective approach for both well rehabilitation and frequent solid sampling at the same location.

Wu, Wei-min↗