Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An instrument for rapidly measuring plasma distribution functions with high resolution

An instrument which can rapidly measure plasma particle distribution functions has been developed based upon recent innovations in electrostatic analyzer design and position sensitive particle detection. The new analyzer uses a quadrispherical geometry, but has a completely uniform 360 deg fan-shaped field of view. The polar angular distribution of entering particles is spatially imaged onto a position sensitive detector at the annular exit aperture after a deflection through 90 deg. Several methods of position sensitive detection have been successfully used in conjunction with this analyzer. The simplest is individual channel multipliers spaced around the annular exit. Microchannel plate electron multipliers permit greater position resolution to be obtained, and a detector using microchannel plates followed by a resistive anode image converter obtains angular resolution of about one degree, i.e., 360 individual angle pixels. Instruments of this type were flown on a sounding rocket in early 1982 and will be included on the Giotto comet mission and the AMPTE ion release module (IRM).

Carlson, C. W.↗

First- and Second-Order Sensitivity Analysis of a P-Version Finite Element Equation Via Automatic Differentiation

Sensitivity analysis is a technique for determining derivatives of system responses with respect to design parameters. Among many methods available for sensitivity analysis, automatic differentiation has been proven through many applications in fluid dynamics and structural mechanics to be an accurate and easy method for obtaining derivatives. Nevertheless, the method can be computational expensive and can require a high memory space. This project will apply an automatic differentiation tool, ADIFOR, to a p-version finite element code to obtain first- and second- order then-nal derivatives, respectively. The focus of the study is on the implementation process and the performance of the ADIFOR-enhanced codes for sensitivity analysis in terms of memory requirement, computational efficiency, and accuracy.

Hou, Gene↗

Yet another parameter-free shape optimization method

The use of node coordinates as design variables in shape optimization offers a larger design space than computer-aided design (CAD)-based shape parameterizations. It also allows for the optimization of legacy designs, i.e., a finite element mesh from an existing design can be readily optimized to meet new performance requirements without involving a CAD model. However, it is well known that the node coordinate parameterization method is fraught with numerical difficulties, which makes it impractical to use. This has led to several of “parameter-free” shape optimization methods that seek the advantages and avoid the pitfalls of the naïve node coordinate parameterization method. These methods come in two main varieties: sensitivity filtering (or gradient smoothing) and consistent filtering. The latter is analogous to the density filter method used in topology optimization (TO). In this work, we use the PDE filter from TO and energy-based filters to implement consistent shape optimization filtering schemes easily and efficiently. Numerical experiments demonstrate that consistent methods are more robust than sensitivity filtering methods.

42 ENGINEERING↗

Aerodynamic design optimization using sensitivity analysis and computational fluid dynamics

A new and efficient method is presented for aerodynamic design optimization, which is based on a computational fluid dynamics (CFD)-sensitivity analysis algorithm. The method is applied to design a scramjet-afterbody configuration for an optimized axial thrust. The Euler equations are solved for the inviscid analysis of the flow, which in turn provides the objective function and the constraints. The CFD analysis is then coupled with the optimization procedure that uses a constrained minimization method. The sensitivity coefficients, i.e. gradients of the objective function and the constraints, needed for the optimization are obtained using a quasi-analytical method rather than the traditional brute force method of finite difference approximations. During the one-dimensional search of the optimization procedure, an approximate flow analysis (predicted flow) based on a first-order Taylor series expansion is used to reduce the computational cost. Finally, the sensitivity of the optimum objective function to various design parameters, which are kept constant during the optimization, is computed to predict new optimum solutions. The flow analysis of the demonstrative example are compared with the experimental data. It is shown that the method is more efficient than the traditional methods.

Baysal, Oktay↗

Increasing the Sensitivity of Lidar Systems Based on the LF/LIF Method

The results of studies on the development of laser sources in the UV and IR spectral ranges for the lidar systems operating on the basis of a method of laser fragmentation with subsequent laser-induced fluorescence (LF/LIF) are presented. It is shown that LF/LIF is an effective method for the remote detection of harmful and dangerous substances including nitrogen oxides in the atmosphere. The formation of a high-quality sounding UV radiation in excimer lasers and its transportation along the atmospheric path is studied. The causes are revealed that lead to the formation of noise arising in the atmosphere and limiting the sensitivity of the applied method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An n -material thresholding method for improving integerness of solutions in topology optimization

It is common in solving topology optimization problems to replace an integer-valued characteristic function design field with the material volume fraction field, a real-valued approximation of the design field that permits "fictitious" mixtures of materials during intermediate iterations in the optimization process. This is reasonable so long as one can interpolate properties for such materials and so long as the final design is integer valued. For this purpose, we present a method for smoothly thresholding the volume fractions of an arbitrary number of material phases which specify the design. This method is trivial for two-material design problems, for example, the canonical topology design problem of specifying the presence or absence of a single material within a domain, but it becomes more complex when three or more materials are used, as often occurs in material design problems. We take advantage of the similarity in properties between the volume fractions and the barycentric coordinates on a simplex to derive a thresholding, method which is applicable to an arbitrary number of materials. As we show in a sensitivity analysis, this method has smooth derivatives, allowing it to be used in gradient-based optimization algorithms. Finally, we present results, which show synergistic effects when used with Solid Isotropic Material with Penalty and Rational Approximation of Material Properties material interpolation functions, popular methods of ensuring integerness of solutions.

42 ENGINEERING↗

WE-FG-206-07: Assessing the Lung Function of Patients with Non-Small Cell Lung Cancer Using Hyperpolarized Xenon-129 Dissolved-Phase MRI

Purpose: Hyperpolarized xenon-129 dissolved-phase MRI is the first imaging technique that allows 3-dimensional regional mapping of ventilation and gas uptake by tissue and blood the in human lung. Multiple outcome measures can be produced from this method. Existing studies in subjects with major lung diseases compared to healthy controls demonstrated high sensitivities of this method to pulmonary physiological factors including ventilation, alveolar tissue density, surface-to-volume ratio, pulmonary perfusion and gas-blood barrier thickness. The purpose of this study is to evaluate the utility of this new imaging tool to assess the lung function in patients with non-small cell lung cancer (NSCLC). Methods: Ten healthy controls (age: 63±10) and five patients (age: 62±13) with NSCLC underwent the xenon-129 dissolved-phase MRI, pulmonary function test (PFT) and CT for clinical purpose. Three outcome measures were produced from xenon-129 dissolved-phase MRI, including ventilation defect fraction (Vdef%) reflecting the airflow obstruction, tissue-to-gas ratio reflecting lung tissue density, and RBC-to-tissue ratio reflecting pulmonary perfusion and gas exchange. Results: Compared to healthy controls, patients with NSCLC showed more ventilation defects (NSCLC: 22±6%; control: 40±18%; P=0.01), lower tissue-to-gas (NSCLC: 0.82±0.31%; control: 1.07±0.13%; P=0.05) and RBC-to-tissue ratios (NSCLC: 0.82±0.31%; control: 1.07±0.13%; P=0.01). Maps for ventilation and gas uptake by tissue and blood were highly heterogeneous in the lungs of patients. Vdef% and RBC-to-tissue ratios in all 15 subjects correlated with corresponding global lung functional measures from PFT: FEV1/FVC (R=−0.91, P<0.001) and DLCO % predicted (R=0.54, P=0.03), respectively. The tissue-to-gas ratios correlated with tissue density (HU) measured by CT (R=0.88, P<0.001). Conclusion: With the unique ability to provide detailed information about lung function including ventilation, tissue density, perfusion and gas exchange with 3D resolution, hyperpolarized xenon-129 dissolved-phase MRI has high potential to be used as an important reference for radiotherapy treatment planning and for evaluating the side effects of the treatment. Receive research support and funding from Siemens.

60 APPLIED LIFE SCIENCES↗

A New Equivalence Theory Method for Treating Doubly Heterogeneous Fuel - I. Theory

A new methodology has been developed to treat resonance self-shielding in doubly heterogeneous very high temperature gas-cooled reactor systems in which the fuel compact region of a reactor lattice consists of small fuel grains dispersed in a graphite matrix. This new method first homogenizes the fuel grain and matrix materials using an analytically derived disadvantage factor from a two-region problem with equivalence theory and intermediate resonance method. This disadvantage factor accounts for spatial self-shielding effects inside each grain within the framework of an infinite array of grains. Then the homogenized fuel compact is self-shielded using a Bondarenko method to account for interactions between the fuel compact regions in the fuel lattice. In the final form of the equations for actual implementations, the double-heterogeneity effects are accounted for by simply using a modified definition of a background cross section, which includes geometry parameters and cross sections for both the grain and fuel compact regions. With the new method, the doubly heterogeneous resonance self-shielding effect can be treated easily even with legacy codes programmed only for a singly heterogeneous system by simple modifications in the background cross section for resonance integral interpolations. This paper presents a detailed derivation of the new method and a sensitivity study of double-heterogeneity parameters introduced during the derivation. The implementation of the method and verification results for various test cases are presented in the companion paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prediction of payload vibration environments by mechanical admittance test techniques

A series of experiments was conducted with simple beam and mass launch vehicle and payload models in order to determine the validity of mechanical admittance/impedance techniques applied to development of improved payload vibration tests. Admittances and impedances were measured from tests of the individual components to form matrices which were combined analytically to allow prediction of responses for the complete system. Results were computed for a transmission matrix approach and an admittance matrix approach. Both a rigid body and a flexible payload model were considered. The results clearly demonstrate that the transmission matrix method is too sensitive to measurement error to be practical for this application, while the pure admittance matrix method produces quite satisfactory results. The effects of various errors on the final results are demonstrated.

Kana, D. D.↗

Further comparison of two synoptic surface wind and pressure analysis methods

The geostrophic stream and potential functions of Sangster and the derived flat pressure field of Pielke and Cram are further compared. A simple numerical experiment with an idealized mountain-atmosphere system compares the two methods and their sensitivity to lateral boundary conditions. The flat pressure field of Pielke and Cram is essentially equivalent to the stream-function of Sangster, although the two methods have different boundary condition formulations and resulting different sensitivities to these boundary conditions.

Cram, Jennifer M.↗

Structural and functional impact of troponin C-mediated Ca 2+ sensitization on myofilament lattice spacing and cross-bridge mechanics in mouse cardiac muscle

Acto-myosin cross-bridge kinetics are important for beat-to-beat regulation of cardiac contractility; however, physiological and pathophysiological mechanisms for regulation of contractile kinetics are incompletely understood. Here we explored whether thin filament-mediated Ca 2+ sensitization influences cross-bridge kinetics in permeabilized, osmotically compressed cardiac muscle preparations. We used a murine model of hypertrophic cardiomyopathy (HCM) harboring a cardiac troponin C (cTnC) Ca 2+ -sensitizing mutation, Ala8Val in the regulatory N-domain. We also treated wild-type murine muscle with bepridil, a cTnC-targeting Ca 2+ sensitizer. Our findings suggest that both methods of increasing myofilament Ca 2+ sensitivity increase cross-bridge cycling rate measured by the rate of tension redevelopment (k TR ); force per cross-bridge was also enhanced as measured by sinusoidal stiffness and I 1,1 -1/I 1,0 ratio from X-ray diffraction. Computational modeling suggests that Ca 2+ sensitization through this cTnC mutation or bepridil accelerates k TR primarily by promoting faster cross-bridge detachment. To elucidate if myofilament structural rearrangements are associated with changes in k(TR), we used small angle X-ray diffraction to simultaneously measure myofilament lattice spacing and isometric force during steady-state Ca 2+ activations. Within in vivo lattice dimensions, lattice spacing and steady-state isometric force increased significantly at submaximal activation. We conclude that the cTnC N-domain controls force by modulating both the number and rate of cycling cross-bridges, and that the both methods of Ca 2+ sensitization may act through stabilization of cTnC's D-helix. Furthermore, we propose that the transient expansion of the myofilament lattice during Ca 2+ activation may be an additional factor that could increase the rate of cross-bridge cycling in cardiac muscle. These findings may have implications for the pathophysiology of HCM.

60 APPLIED LIFE SCIENCES↗

SU-E-T-474: IMRT Verification Using the On-Board EPID

Purpose: To verify IMRT and Rapid Arc (RA) plan's agreement with treatment delivery for radiation therapy using an on-board EPID compared to MapCHECK2 and ArcCHECK. Methods: On-board EPID (Exact arm) is commissioned using manufacturer's Preconfigured Data Input Package (PDIP). Portal dose calculation engine for comparison with measurement was commissioned with PDIP. The absolute dosimetric calibration of the EPID is performed using 10×10cm field size at 105cm source to image detector distance with 90.7 CU in the integrated mode. The dark and flood field of EPID were also calibrated in the integrated mode for all energies and dose rates. The output dose-response data from the manufacturer was verified. The improved gamma test method was used for EPID data analysis. Gamma test were used for MapCHECK2 (or ArcCHECK). The sensitivity of the method was tested using collimator rotation at 3 degree and 5 degree. Student T-test was used to distinguish the difference among the groups. Results: IMRT: The average of Gamma passing rate using EPID and MapCHECK2 is 98.9±1.6% and 98.7±2.0% (p = 0.342). There is no statistical difference between two groups.RA: The average of Gamma passing rate using EPID and ArcCHECK is 97.2±2.3% and 93.2±4.1%. (p = 0.002). EPID significantly improved the RapidARC plan passing rate compared to the ArcCHECK. 5% dose change typically causes between 3 – 55% change in Gamma. Conclusion: Using the EPID, we were able to perform QA verification on IMRT plans comparable to MapCHECK2 (p=0.342) and superior to that of ArcCHECK (p=0.002) using Gamma 3%, 3mm criteria. The sensitivity of EPID was found to be comparable to that of the MapCHECK2 and ArcCHECK. EPID dosimetry is faster (4.3 mins vs. 10 mins) due to easier setup and integrated data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integral Activity-Based Protein Profiling Method for Higher Throughput Determination of Protein Target Sensitivity to Small Molecules

Activity-based protein profiling (ABPP) is a chemoproteomic technique that uses small molecule probes to label active enzymes selectively and covalently in complex proteomes. Competitive ABPP, which involves treatment of the active proteome with an analyte of interest, is especially powerful for profiling how small molecules impact specific protein activities. Advances in higher throughput workflows have made it possible to generate extensive competitive ABPP data across diverse biological samples, making this approach highly appealing for characterizing shared and unique proteins affected by perturbations such as drug or chemical exposures. To use the competitive ABPP approach effectively to understand potential adverse effects of chemicals of concern (CoC), a wide range of concentrations may be needed, particularly for chemicals that lack potency or toxicity data. In this work, we present an integral competitive ABPP method that enables target sensitivity determination for different organophosphate (OP) pesticides as model toxicants. Using previously developed OP-ABPs, we optimized conditions for tandem mass tag (TMT) multiplexing of ABPP samples and compared conventional competitive ABPP involving samples at discrete paraoxon concentrations to pooled samples across that same concentration range. We then expanded our approach to compare protein target sensitivities toward two additional OP pesticides, chlorpyrifos oxon and malaoxon. The results showed that differences in integral intensities for the pooled competition sample can be used to evaluate the relative sensitivity of specific proteins without increasing the overall number of samples. For 8 CoC concentrations of interest, this strategy reduced the number of TMT plexes and the corresponding number of LC–MS/MS analyses 3-fold. In conclusion, we envision the integral ABPP (IABPP) method will provide a means to screen diverse chemicals more rapidly to identify both high and low sensitivity protein targets.

activity-based probes↗

ADVANCING REACTIVE TRACER METHODS FOR MONITORING THERMAL DRAWDOWN IN GEOTHERMAL ENHANCED GEOTHERMAL RESERVOIRS

Reactive tracers have long been considered a possible means of measuring thermal drawdown in a geothermal system, before significant cooling occurs at the extraction well. Here, we examine the sensitivity of the proposed method to evaluate reservoir cooling and demonstrate that while the sensitivity of the method as generally proposed is low, it may be practical under certain conditions.

15 GEOTHERMAL ENERGY↗

Minimal spanning tree algorithm for γ-ray source detection in sparse photon images: cluster parameters and selection strategies

We present that the minimal spanning tree (MST) algorithm is a graph-theoretical cluster-finding method. We previously applied it to γ-ray bidimensional images, showing that it is quite sensitive in finding faint sources. Possible sources are associated with the regions where the photon arrival directions clusterize. MST selects clusters starting from a particular “tree” connecting all the point of the image and performing a cut based on the angular distance between photons, with a number of events higher than a given threshold. In this paper, we show how a further filtering, based on some parameters linked to the cluster properties, can be applied to reduce spurious detections. We find that the most efficient parameter for this secondary selection is the magnitudeM of a cluster, defined as the product of its number of events by its clustering degree. We test the sensitivity of the method by means of simulated and real Fermi-Large Area Telescope (LAT) fields. Our results show that √M is strongly correlated with other statistical significance parameters, derived from a wavelet based algorithm and maximum likelihood (ML) analysis, and that it can be used as a good estimator of statistical significance of MST detections. Finally, we apply the method to a 2-year LAT image at energies higher than 3 GeV, and we show the presence of new clusters, likely associated with BL Lac objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time monitoring of graphene patterning with wide-field four-wave mixing microscopy

The single atom thick two-dimensional graphene is a promising material for various applications due to its extraordinary electronic, optical, optoelectronic, and mechanical properties. The demand for developing graphene based applications has entailed a requirement for development of methods for fast imaging techniques for graphene. Here, we demonstrate imaging of graphene with femtosecond wide-field four-wave mixing microscopy. The method provides a sensitive, non-destructive approach for rapid large area characterization of graphene. We show that the method is suitable for online following of a laser patterning process of microscale structures on single-layer graphene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-fidelity parametric sensitivity estimation for large eddy simulation with the Spalart–Allmaras model

A computationally affordable approach to estimate parametric sensitivities of engineering relevant quantities of interest for a large eddy simulation (LES) is explored. The method is based on defining a Reynolds-averaged Navier–Stokes (RANS) problem that is constrained to reproduce the LES mean flow field. Here, the proposed method is described and assessed for a shock/boundary layer interaction problem, where the shock angle and wall temperature are considered variable or uncertain. In the current work, we show that the proposed method offers improved sensitivity predictions for certain flow features as compared to standalone RANS simulations, while using a fraction of the LES cost.

42 ENGINEERING↗