Search NASA⌕ Search

SEARCH · Search NASA

Results for “side load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Design and Analysis of the US ITER Central Solenoid Module Lifting Fixture

The central solenoid (CS) consists of six large high field superconducting magnets (also known as modules) approximately 4 m in diameter and 2 m tall that weigh approximately 120 tonnes each. These large and complex modules create challenges during assembly of the CS that require the development of custom assembly tooling such as the CS lifting fixture. The CS module lifting fixture is designed to lift and stack the six CS modules in the assembly building on the ITER site. Because of its unique design, fabrication, and assembly features, no lifting attachments could be incorporated within or under the CS modules. This limitation motivated the development of a friction-based lift fixture. The design and evaluation of the CS module lifting fixture considered both worker safety and investment protection, and the assessments were performed to international codes and standards. The CS module lifting fixture consists of two principal subassemblies: spider assembly and ring weldment. These subassemblies allow the frictional force to be augmented by the mechanical advantage of shallow-angle wedges. Large radial preloads created by both screw jack assemblies and the weight of a CS module develop frictional forces capable of performing a lift with a safety factor of at least 2. The design effort resulted in the use of low friction linear bearings on angle surfaces to ensure constant pressure, integrated jacks for pretensioning the fixture prior to lifting, and load pin strain gauges for monitoring the normal force. Testing of various materials and surface treatments led to the selection of laminated aluminum and rubber pads as the friction interface on the CS lifting fixture side and a grit-blasted Nitronic 50 stainless steel band on the CS module side. A redundant lifting method using the module slings between the spider and module is also utilized after the initial friction lift. The CS lifting fixture provides a safe and reliable solution for lifting and stacking the CS module during assembly.

Morris, Eric↗

Smart Meters Enabling Voltage Monitoring and Control Functionalities: The Last-Mile Voltage Stability Issue

It is a demanding yet challenging task to design the next generation of smart meters. This work investigates the new voltage monitoring and control function for the next-generation smart meters, and identifies its added values for power system voltage stability issues. In terms of voltage monitoring, the risk benefit analysis for adding voltage magnitudes to smart meter measurements is presented, and the risk mitigation strategies along with the co-simulation validation via GridLAB-D and NS-3 are proposed, all providing insight into the new function evaluation. In terms of voltage control, a new voltage stability control scheme is developed, which uses voltage measurements from smart meters and utilizes the observability and controllability of distributed energy resources and controllable loads. Different from traditional voltage control schemes focusing on voltage regulation and power quality monitoring from the utility perspective, the proposed control scheme can achieve the maximum real power transfer margin at the end user side, enabling the voltage stability issues being solved at the grid edge, i.e. the last-mile segment. It is the first work that considers voltage monitoring and control collectively for smart meter investment. It can help power engineering community supplement smart meter applications and shape the next-generation smart meters.

42 ENGINEERING↗

How to Obtain Reproducible Results for Lithium Sulfur Batteries

The basic requirements for getting reliable Li-S battery data have been discussed in this work. Unlike Li-ion batteries, electrolyte-rich environment significantly affects the cycling stability of Li-S batteries prepared and tested under the same conditions. The reason has been assigned to the different concentrations of polysulfide-containing electrolytes in the cells, which have profound influences on both sulfur cathode and lithium anode. At optimized S/E ratio of 50 g L-1, a good balance among electrolyte viscosity, wetting ability, diffusion rate dissolved polysulfide and nucleation/growth of short-chain Li2S/Li2S2 has been built along with largely reduced contamination on the lithium anode side. Accordingly, good cyclability, high reversible capacity and Coulombic efficiency are achieved in Li-S cell with controlled S/E ratio without any additive. Other factors such as sulfur content in the composite and sulfur loading on the electrode also need careful concern in Li-S system in order to generate reproducible results and gauge the various methods used to improve Li-S battery technology.

Cycling stability↗

The PNNL Lab Homes Experimental Plan, FY12-FY15

Retrofitting and renovating existing homes to save energy has become an increasingly important component of the Nation’s energy strategy. Recognizing the need to aggressively research and develop deep energy retrofit strategies for existing homes, the U.S. Department of Energy (DOE) is pursuing many innovative and impactful projects as part of its Building America (BA) program. One of these projects is providing partial support for two factory-built Lab Homes recently installed on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington, which allow for the validation, demonstration, and characterization of new, energy efficient and peak load shaving technologies. The experimental home is retrofit with an energy- or water-efficient or smart technology to demonstrate the performance of that technology, while the baseline home serves as the control for side-by-side comparison of performance in homes with and without the retrofit measure under identical occupancy rates and weather conditions. Together, they serve as a research platform for testing and comparing new ideas and approaches that are applicable to site-built and manufactured homes. As the Lab Homes steward, PNNL works with multiple clients and stakeholders to use the Lab Homes for experiments focused on reducing energy use, improving grid responsiveness, and shaving peak demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Depletion Simulations for a High Flux Isotope Reactor Cycle with a Representative Experiment Loading

The purpose of this report is to document a high-fidelity VESTA/MCNP High Flux Isotope Reactor (HFIR) core model that features a new, representative experiment loading. This model, which represents the current, high-enriched uranium fuel core, will serve as a reference for low-enriched uranium conversion studies, safety-basis calculations, and other research activities. A new experiment loading model was developed to better represent current, typical experiment loadings, in comparison to the experiment loading included in the model for Cycle 400 (operated in 2004). The new experiment loading model for the flux trap target region includes full length 252 Cf production targets, 75 Se production capsules, 63 Ni production capsules, a 188 W production capsule, and various materials irradiation targets. Fully loaded 238 Pu production targets are modeled in eleven vertical experiment facilities located in the beryllium reflector. Other changes compared to the Cycle 400 model are the high-fidelity modeling of the fuel element side plates and the material composition of the control elements. Results obtained from the depletion simulations with the new model are presented, with a focus on time-dependent isotopic composition of irradiated fuel and single cycle isotope production metrics.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Space-charge-limited solid-state triode

A solid-state triode is provided from a wafer of nearinstrinsic semiconductor material sliced into filaments of rectangular cross section. Before slicing, emitter and collector regions are formed on the narrow sides of the filaments, and after slicing gate regions are formed in arrow strips extending longitudinally along the midsections of the wide sides of the filaments. Contacts are then formed on the emitter, collector and gate regions of each filament individually for a single filament device, or in parallel for an array of filament devices to increase load current.

Shumka, A.↗

The erosion/corrosion of small superalloy turbine rotors operating in the effluent of a PFB coal combustor

The operation of a turbine in the effluent of a pressurized fluidized bed (PFB) coal combustor presents serious materials problems. Synergistic erosion/corrosion and deposition/corrosion interactions may favor the growth of erosion-resistant oxides on blade surfaces, but brittle cracking of these oxides may be an important source of damage along heavy particle paths. Integrally cast alloy 713LC and IN792 + Hf superalloy turbine rotors in a single-stage turbine with 6% partial admittance have been operated in the effluent of a PFB coal combustor for up to 164 hr. The rotor erosion pattern exhibits heavy particle separation with severe erosion at the leading edge, pressure side center, and suction side trailing edge at the tip. The erosion distribution pattern gives a spectrum of erosion/oxidation/deposition as a function of blade position. The data suggest that preferential degradation paths may exist even under the targeted lower loadings (less than 20 ppm).

Zellars, G. R.↗

Mixed-mode fracture in unidirectional graphite epoxy composite laminates with central notch

Mixed-mode matrix fracture in central notched off-axis unidirectional composite laminates was investigated. A limited number of unidirectional tensile type specimens with a central, horizontal, notch were tested. Crack initiation and propagation were examined under various local stress fields that were controlled by fiber orientations. The tested specimens were simulated using a two dimensional finite element method with constant strain loading. The strain energy release rates along the crack were evaluated via crack closure technique. The variation of critical strain energy rates with off-axis angle was studied. The results from single (one-sided) and double (two-sided) crack simulations were presented and compared.

Binienda, Wieslaw K.↗

Heat transfer and core neutronics considerations of the heat pipe cooled thermionic reactor

The authors summarize the results of detailed neutronic and thermal-hydraulic evaluations of the heat pipe cooled thermionic (HPTI) reactor design, identify its key design attributes, and quantify its performance characteristics. The HPTI core uses modular, liquid-metal core heat transfer assemblies to replace the liquid-metal heat transport loop employed by in-core thermionic reactor designs of the past. The nuclear fuel, power conversion, heat transport, and heat rejection functions are all combined into a single modular unit. The reactor/converter assembly uses UN fuel pins to obtain a critical core configuration with in-core safety rods and reflector controls added to complete the subassembly. By thermally bonding the core heat transfer assemblies during the reactor core is coupled neutronically, thermally, and electrically into a modular assembly of individual power sources with cross-tied architecture. A forward-facing heat pipe radiator assembly extends from the reactor head in the shape of a frustum of a cone on the opposite side of the power system from the payload. Important virtues of the concept are the absence of any single-point failures and the ability of the core to effectively transfer the TFE waste heat load laterally to other in-core heat transfer assemblies in the event of multiple failures in either in-core and radiator heat pipes.

Determan, W. R.↗

Crush Test Abuse Stand

The purpose of this system is to simulate an internal short on battery cells by causing deformation (a crushing force) in a cell without penetration. This is performed by activating a hydraulic cylinder on one side of a blast wall with a hydraulic pump located on the other. The operator can control the rate of the crush by monitoring a local pressure gauge connected to the hydraulic cylinder or a load cell digital display located at the hydraulic pump control area. The internal short simulated would be considered a worst-case scenario of a manufacturer fs defect. This is a catastrophic failure of a cell and could be a very destructive event. Fully charged cells are to have an internal short simulated at the center of the length of the cell (away from terminals). The crush can be performed with a .- to 1-in. (.0.6- to 2.5-cm) rod placed crossways to the cell axis, causing deformation of the cell without penetration. The OCV (open-circuit voltage) and temperature of the cells, as well as the pressure and crushing force, are recorded during the operation. Occurrence of an internal short accompanied by any visible physical changes such as venting, fires, or explosions is reported. Typical analytical data examined after the test would be plots of voltage, temperature, and pressure or force versus time. The rate of crushing force can be increased or decreased based on how fast the operator pumps the hydraulic pump. The size of cylinder used to compress the battery cell can be easily changed by adding larger or smaller fittings onto the end of the hydraulic cylinder based on the battery/cell size being tested. The cell is crushed remotely and videotaped, allowing the operator to closely monitor the situation from a safe distance.

Collins, Jacob↗

Hybrid probabilistic-possibilistic approach for capacity credit evaluation of demand response considering both exogenous and endogenous uncertainties

As a featured smart-grid technology, demand response (DR) provides utility companies with unprecedented flexibility to improve the reliability of electricity service in future power systems. However, due to the uncertainties arising from the demand side, the extent to which DR can be utilized for capacity support poses a major question to the utilities. To address this issue, this paper proposes a new methodological framework to assess the potential reliability value of DR in smart grids. The framework is established on the concept of capacity credit (CC), and it accommodates different types of uncertainties (i.e., probabilistic and possibilistic) accrued from physical and anthropogenic factors in DR programs. The capability of DR during operation is considered as a synthesized result of multiple facets, i.e., users' load characteristics, participation levels, and load recoveries, and different models are developed to represent each component. To characterize the stochastic nature of demand responsiveness, the fuzzy theory is introduced, and possibilistic models are proposed to describe the human-related uncertainties under incomplete information. In addition, considering that in reality, DR operation could affect the comfort of customers, the dynamics of demand-side participation have also been incorporated in our study, in which two utility-based indices are defined to quantify the effect of such interdependency. Using a probabilistic propagation technique, the different types of uncertainties involved can be normalized and systematically addressed under the same framework. Then, the relevant models can be applied to the CC evaluation procedures, wherein two dispatching schemes (i.e., reliability-driven and coordinated management) are considered to study the effect of DR operation on its CC. The proposed methodology is tested on a modified RTS system, and the obtained results confirm its effectiveness.

capacity credit↗

Automated Transmission Loss Measurement in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center

A technique to measure the radiated acoustic intensity and transmission loss of panels is documented in this paper. This facility has been upgraded to include a test fixture that scans the acoustic intensity radiated from a panel on the anechoic receiving room side of the transmission loss window. The acoustic intensity incident on the panel from the reverberant side of the transmission loss window is estimated from measurements made using six stationary microphones in the reverberant source room. From the measured incident and radiated intensity, the sound power transmission loss is calculated. The setup of the facility and data acquisition system are documented. A transmission loss estimate of a typical panel is shown. The measurement-to-measurement and setup-to-setup repeatability of the transmission loss estimate are assessed. Conclusions are drawn about the ability to measure changes in transmission loss due to changes in panel construction.

Klos, J.↗

Elimination of metabolic pathways to all traditional fermentation products increases ethanol yields in Clostridium thermocellum

Clostridium thermocellum has the natural ability to convert cellulose to ethanol, making it a promising candidate for consolidated bioprocessing (CBP) of cellulosic biomass to biofuels. To further improve its CBP capabilities, we study a mutant strain of C. thermocellum that was constructed (strain AG553; C. thermocellum Δhpt ΔhydG Δldh Δpfl Δpta-ack ) to increase flux to ethanol by removing side product formation. Strain AG553 showed a two- to threefold increase in ethanol yield relative to the wild type on all substrates tested. On defined medium, strain AG553 exceeded 70% of theoretical ethanol yield on lower loadings of the model crystalline cellulose Avicel, effectively eliminating formate, acetate, and lactate production and reducing H 2 production by fivefold. On 5 g/L Avicel, strain AG553 reached an ethanol yield of 63.5% of the theoretical maximum compared with 19.9% by the wild type, and it showed similar yields on pretreated switchgrass and poplar. The elimination of organic acid production suggested that the strain might be capable of growth under higher substrate loadings in the absence of pH control. Final ethanol titer peaked at 73.4 mM in mutant AG553 on 20 g/L Avicel, at which point the pH decreased to a level that does not allow growth of C. thermocellum , likely due to CO 2 accumulation. In comparison, the maximum titer of wild type C. thermocellum was 14.1 mM ethanol on 10 g/L Avicel. In conclusion, with the elimination of the metabolic pathways to all traditional fermentation products other than ethanol, AG553 is the best ethanol-yielding CBP strain to date and will serve as a platform strain for further metabolic engineering for the bioconversion of lignocellulosic biomass.

09 BIOMASS FUELS↗

Wide angle pinhole camera

Hemispherical refracting element gives pinhole camera 180 degree field-of-view without compromising its simplicity and depth-of-field. Refracting element, located just behind pinhole, bends light coming in from sides so that it falls within image area of film. In contrast to earlier pinhole cameras that used water or other transparent fluids to widen field, this model is not subject to leakage and is easily loaded and unloaded with film. Moreover, by selecting glass with different indices of refraction, field at film plane can be widened or reduced.

Franke, J. M.↗

Performance analysis for collector-side reflector systems

The F-Chart method of solar collector performance evaluation is extended to a flat-plate collector system augmented with planar side reflectors. The modified F-Chart evaluations show that the augmentation of the collector has approximately the effect of increasing the collector area by 60%, and the energy supplied by the collector better matches the load. The installed reflector cost of about 10% of the collector cost is shown to be well justified.

Espy, P. N.↗

High temperature, short term tensile strength of C6000/PMR-15 composites

Tensile tests were conducted on 0 unidirectionally reinforced Celion 6000 graphite fibers in PMR-15 polyimide matrix. Tensile strengths for coupons subjected to short and long term uniform temperatures were obtained. Thick coupons, heated on one side to produce significant transient through thickness temperature gradients, were tested and compared to the strength of specimens with uniform temperature distributions. All coupons were radiantly heated and reached maximum test temperatures within 15 sec. Tensile loads were applied to the coupons after 15 sec of elevated temperature exposure. Loading rates were selected so that specimen failures occurred within a maximum of 45 sec after reaching the test temperature. Results indicate that significant tensile strength remains beyond the material post cure temperature.

Digiovanni, P. R.↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗