Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Curvature of the spectral energy distributions of blazars

In this paper, spectral energy distributions (SED) of both synchrotron and inverse Compton (IC) components of a sample of Fermi bright blazars are fitted by a log-parabolic law. The second-degree term of the log parabola measures the curvature of an SED. We find a statistically significant correlation between the synchrotron peak frequency and its curvature. This result is in agreement with the theoretical prediction and confirms previous studies that dealt with a single source with observations at various epochs or a small sample. If a broken power law is employed to fit the SED, the difference between the two spectral indices (i.e., |α{sub 2} – α{sub 1}|) can be considered a 'surrogate' of the SED curvature. We collect data from the literature and find a correlation between the synchrotron peak frequency and the spectral difference. We do not find a significant correlation between the IC peak frequency and its curvature, which may be caused by a complicated seed photon field. It is also found that the synchrotron curvatures are on average larger than those of IC curvatures, and there is no correlation between these two parameters. As suggested by previous works, both the log-parabolic law of the SED and the above correlation can be explained by statistical and/or stochastic particle accelerations. Based on a comparison of the slops of the correlation, our result seems to favor stochastic acceleration mechanisms and emission processes. Additional evidence, including SED modeling, particle acceleration simulation, and comparisons between some predictions and empirical relations/correlations, also seems to support the idea that the electron energy distribution (and/or synchrotron SED) may be log-parabolic.

79 ASTRONOMY AND ASTROPHYSICS↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinos from cosmic ray accelerators in the Cygnus region of the galaxy

While supernova remnants have been identified as the most likely sources of the galactic cosmic rays, no conclusive observational evidence for this association exists. We show here that IceCube has the possibility of producing incontrovertible evidence by detecting neutrinos produced by the cosmic ray beam interacting with the hydrogen in the vicinity of the supernova shock expanding into the interstellar medium. We show that the observational information on gamma ray fluxes from the Cygnus region, although limited, is sufficient to pinpoint the expected event rate of the neutrinos associated with a single source of 0.5 Crab at the TeV level to within a factor of 2, between 2 and 3.8 neutrinos per year. Finally, we note that recent gamma-ray observations reveal the presence of at least three and possibly up to eight such sources, raising the possibility of seeing more than 10 neutrinos per year from these sources alone.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THE HIGH ENERGY BUDGET ALLOCATIONS IN SHOCKS AND GAMMA RAY BURSTS

The statistical distribution of energies among particles responsible for long gamma-ray burst (GRB) emission is analyzed in light of recent results of the Fermi Observatory. The all-sky flux, F{sub {gamma}}, recorded by the Gamma-Ray Burst Monitor (GBM) is shown, despite its larger energy range, to be not significantly larger than that reported by the Burst and Transient Explorer, suggesting a relatively small flux in the 3-30 MeV energy range. The present-day energy input rate in {gamma}-rays recorded by the GBM from long GRBs is found, assuming star formation rates in the literature, to be W-dot(0)=0.5 F{sub {gamma}H}/c=5x10{sup 42}erg Mpc{sup -3} yr{sup -1}. The Large Area Telescope fluence, when observed, is about 5%-10% per decade of the total, in good agreement with the predictions of saturated, nonlinear shock acceleration. The high-energy component of long GRBs, as measured by Fermi, is found to contain only {approx}10{sup -2.5} of the energy needed to produce ultrahigh-energy cosmic rays (UHECRs) above 4 EeV, assuming the latter to be extragalactic, when various numerical factors are carefully included, if the cosmic-ray source spectrum has a spectral index of -2. The observed {gamma}-ray fraction of the required UHECR energy is even smaller if the source spectrum is softer than E {sup -2}. The AMANDA II limits rule out such a GRB origin for UHECRs if much more than 10{sup -2} of the cosmic-ray energy goes into neutrinos that are within, and simultaneous with, the {gamma}-ray beam. It is suggested that 'orphan' neutrinos out of the {gamma}-ray beam might be identifiable via orphan afterglow or other wide angle signatures of GRBs in lieu of coincidence with prompt {gamma}-rays, and it is recommended that feasible single neutrino trigger criteria be established to search for such coincidences.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking Study for Top-off Safety Validation at SSRL

A tracking study was performed at SSRL to identify necessary controls and to prove the safety of top-off operation from radiation hazard under such conditions. The safety rationale, tracking setup and the results are presented. Top-off operational mode has become a trend for existing and planned third-generation storage ring light sources for the many benefits such as increased average brightness, improved thermal stability and elimination of the interruption to user experiments due to traditional injection [1, 2]. Unlike the traditional decay mode injection which happens a few times a day and during which the photon beamline shutters are closed, top-off mode injection requires photon beamline shutters to remain open during injection and occurs much more frequently, from once every 5 seconds to once every 30 minutes. Therefore injection may be transparent to user experiments and the stored current variation can be significantly reduced. For a facility equipped with a full-energy injector, the biggest challenge to the implementation of the top-off mode may be the control of radiation hazard. Studies at ALS and SSRL [2, 3] have shown that a single injected electron pulse that enters the photon beamline and exits the radiation shield wall would cause unacceptable radiation doses on the experimental floor. For the protection of users and experimental equipment, it is hence a prerequisite for top-off operation to establish controls that absolutely prevent such occurrences. Similar to other facilities such as ALS and APS [2, 4], tracking simulations were conducted at SSRL to identify the control measures, define the specifications and prove the radiation safety. However, a different approach toward the proof of safety is taken at SSRL. In this paper we first describe the SSRL accelerator complex with emphasis on the aspects related to top-off in section 2. The general considerations and requirements for top-off are presented in section 3. Section 4 and 5 give a detailed description of the tracking setup and results. Concluding remarks are given in section 6.

43 PARTICLE ACCELERATORS↗

Single-Particle Studies Reveal a Nanoscale Mechanism for Elastic, Bright, and Repeatable ZnS:Mn Mechanoluminescence in a Low-Pressure Regime

Mechanoluminescent materials, which emit light in response to elastic deformation, are demanded for use as in situ stress sensors. ZnS doped with Mn is known to exhibit one of the lowest reported thresholds for appearance of mechanoluminescence, with repeatable light emission under contact pressure <10 MPa. Here, the physical basis for such behavior remains as yet unclear. Here, reliable microscopic detection of mechanoluminescence of single ZnS:Mn microparticles, in combination with nanoscale structural characterization, provides evidence that the mechanoluminescent properties of these particles result from interplay between a non-centrosymmetric crystal lattice and its defects, viz., dislocations and stacking faults. Statistical analysis of the distributions of mechanoluminescence energy release trajectories reveals two distinct mechanisms of excitation: one attributable to a piezo-phototronic effect and the other due to dislocation motion. At pressures below 8.1 MPa, both mechanisms contribute to mechanoluminescent output, with a dominant contribution from the piezo-phototronic mechanism. In contrast, above 8.1 MPa, dislocation motion is the primary excitation source. For the piezo-phototronic mechanism, we propose a specific model that accounts for elastic ZnS:Mn mechanoluminescence under very low pressure. The charged interfaces in stacking faults lead to the presence of filled traps, which otherwise would be empty in the absence of the built-in electric field. Upon application of external stress, local enhancement of the piezoelectric field at the stacking faults’ interfaces facilitates release of the trapped carriers and subsequent luminescence. This field enhancement explains how <10 MPa pressure produces thousands of photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Beamlines and Diagnostics at LCLS

The Linac Coherent Light Source (LCLS) is the first hard-x-ray free electron laser in operation. The turn-on of LCLS was rapid and operation has been reliable. Performance has exceeded the design parameters in several areas. The photon energy output covers a range from 480 eV to over 9 keV; the pulse energy is typically 2-3 mJ, with a maximum of 4 mJ at 2 keV. Electron pulse lengths can be varied from 500 fs to shorter than 10 fs. A low-charge option at 20 pC is being explored, which delivers pulses shorter than 10 fs with a reduced pulse energy, typically around 0.2 mJ. On-demand, single-shot and multi-shot modes up to 60 Hz (planned is 120 Hz) can be made available. The photon diagnostics built for LCLS have been commissioned and provide measurements of various properties of the FEL beam, such as pulse energy, beam size and position, wavelength, and allows for intensity attenuation over the entire wavelength range. The two soft x-ray instruments, the Atomic Molecular and Optics (AMO) and Soft X-ray Material Science (SXR) stations, are fully operational and completed their second user run in mid September 2010. The third user run is scheduled from October to December 2010, and will include the first hard x-ray instrument X-ray Pump-and-Probe (XPP). Three additional hard x-ray stations will follow: CXI (Coherent X-ray Imaging) is planned to start commissioning in December 2010, the XCS (X-ray correlation spectroscopy) instrument will start in June 2011, and the station for Matter in Extreme Conditions (MEC) in 2012. A list of past and future milestones for LCLS commission and operations is shown in table 1. The LCLS hard x-ray Free Electron Laser at SLAC reported first lasing in April of 2009. Since then two successful user runs have been completed at the two soft x-ray stations. The first hard x-ray station has started commissioning in July of 2010. Beam diagnostics play an essential role for tuning the machine and delivering the requested beam properties to the users. An overview of the LCLS photon diagnostics will be presented including some selected commissioning results. Plans for future improvements and upgrades will be briefly discussed.

43 PARTICLE ACCELERATORS↗

Final report : CO2 reduction using biomimetic photocatalytic nanodevices.

Nobel Prize winner Richard Smalley was an avid champion for the cause of energy research. Calling it 'the single most important problem facing humanity today,' Smalley promoted the development of nanotechnology as a means to harness solar energy. Using nanotechnology to create solar fuels (i.e., fuels created from sunlight, CO{sub 2}, and water) is an especially intriguing idea, as it impacts not only energy production and storage, but also climate change. Solar irradiation is the only sustainable energy source of a magnitude sufficient to meet projections for global energy demand. Biofuels meet the definition of a solar fuel. Unfortunately, the efficiency of photosynthesis will need to be improved by an estimated factor of ten before biofuels can fully replace fossil fuels. Additionally, biological organisms produce an array of hydrocarbon products requiring further processing before they are usable for most applications. Alternately, 'bio-inspired' nanostructured photocatalytic devices that efficiently harvest sunlight and use that energy to reduce CO{sub 2} into a single useful product or chemical intermediate can be envisioned. Of course, producing such a device is very challenging as it must be robust and multifunctional, i.e. capable of promoting and coupling the multi-electron, multi-photon water oxidation and CO{sub 2} reduction processes. Herein, we summarize some of the recent and most significant work towards creating light harvesting nanodevices that reduce CO{sub 2} to CO (a key chemical intermediate) that are based on key functionalities inspired by nature. We report the growth of Co(III)TPPCl nanofibers (20-100 nm in diameter) on gas diffusion layers via an evaporation induced self-assembly (EISA) method. Remarkably, as-fabricated electrodes demonstrate light-enhanced activity for CO{sub 2} reduction to CO as evidenced by cyclic voltammograms and electrolysis with/without light irradiation. To the best of our knowledge, it is the first time to observe such a light-enhanced CO{sub 2} reduction reaction based on nanostructured cobalt(III) porphyrin catalysts. Additionally, gas chromatography (GC) verifies that light irradiation can improve CO production by up to 31.3% during 2 hours of electrolysis. In addition, a variety of novel porphyrin nano- or micro-structures were also prepared including nanospheres, nanotubes, and micro-crosses.

14 SOLAR ENERGY↗

Postoperative Radiotherapy in the Management of Resected Non-Small-Cell Lung Carcinoma: 10 Years' Experience in a Single Institute

Purpose: This study reports the long term outcomes of postoperative radiotherapy in patients with resection for non-small-cell lung cancer (NSCLC). Methods and Materials: A total of 98 patients with resected NSCLC who received postoperative radiotherapy (PORT) between January 1994 and December 2004 were retrospectively analyzed. The most frequently performed surgical procedure was lobectomy (59 patients), followed by pneumonectomy (25), wedge resection (8), and bilobectomy (6). Postoperative radiotherapy was delivered as an adjuvant treatment in 71 patients, after a wedge resection in 8 patients, and after an R1 resection in 19 patients. The PORT was administered using a Co-60 source in 86 patients and 6-MV photons in 12 patients. A Kaplan-Meier estimate of overall survival, locoregional control, and distant metastasis-free survival were calculated. Results: Stages included I (n =13), II (n = 50), IIIA (n = 29), and IIIB (n = 6). After a median follow-up of 52 months median survival was 61 months. The 5-year overall survival, locoregional control, and distant metastasis-free survival rates for the whole group were 50%, 78%, and 55% respectively. The RT dose, Karnofsky performance status, age, lateralization of the tumor, and pneumonectomy were independent prognostic factors for OAS; anemia and the number of involved lymph nodes were independent prognostic factors for LC. Conclusions: Doses of PORT of greater than 54 Gy were associated with higher death rate in patients with left-sided tumor, which may indicate a risk of radiation-induced cardiac mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Spatial Resolution Achieved by Chromatic Intensity Interferometry

Interferometers are widely used in imaging technologies to achieve enhanced spatial resolution, but require that the incoming photons be indistinguishable. In previous work, we built and analyzed color erasure detectors which expand the scope of intensity interferometry to accommodate sources of different colors. Here we demonstrate experimentally how color erasure detectors can achieve improved spatial resolution in an imaging task, well beyond the diffraction limit. Utilizing two 10.9 mm-aperture telescopes and a 0.8 m baseline, we measure the distance between a 1063.6 nm source and a 1064.4 nm source separated by 4.2 mm at a distance of 1.43 km, which surpasses the diffraction limit of a single telescope by about 40 times. Moreover, chromatic intensity interferometry allows us to recover the phase of the Fourier transform of the imaged objects – a quantity that is, in the presence of modest noise, inaccessible to conventional intensity interferometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surface plasmon amplification by stimulated emission of radiation (SPASER)

A nanostructure is used to generate a highly localized nanoscale optical field. The field is excited using surface plasmon amplification by stimulated emission of radiation (SPASER). The SPASER radiation consists of surface plasmons that undergo stimulated emission, but in contrast to photons can be localized within a nanoscale region. A SPASER can incorporate an active medium formed by two-level emitters, excited by an energy source, such as an optical, electrical, or chemical energy source. The active medium may be quantum dots, which transfer excitation energy by radiationless transitions to a resonant nanosystem that can play the same role as a laser cavity in a conventional laser. The transitions are stimulated by the surface plasmons in the nanostructure, causing the buildup of a macroscopic number of surface plasmons in a single mode.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Method for surface plasmon amplification by stimulated emission of radiation (SPASER)

A nanostructure is used to generate a highly localized nanoscale optical field. The field is excited using surface plasmon amplification by stimulated emission of radiation (SPASER). The SPASER radiation consists of surface plasmons that undergo stimulated emission, but in contrast to photons can be localized within a nanoscale region. A SPASER can incorporate an active medium formed by two-level emitters, excited by an energy source, such as an optical, electrical, or chemical energy source. The active medium may be quantum dots, which transfer excitation energy by radiationless transitions to a resonant nanosystem that can play the same role as a laser cavity in a conventional laser. The transitions are stimulated by the surface plasmons in the nanostructure, causing the buildup of a macroscopic number of surface plasmons in a single mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Excitation of the Isomeric {sup 229m}Th Nuclear State via an Electronic Bridge Process in {sup 229}Th{sup +}

We consider the excitation of the nuclear transition {sup 229g}Th-{sup 229m}Th near 7.6 eV in singly ionized thorium via an electronic bridge process. The process relies on the excitation of the electron shell by two laser photons whose sum frequency is equal to the nuclear transition frequency. This scheme allows us to determine the nuclear transition frequency with high accuracy. Based on calculations of the electronic level structure of Th{sup +} which combine the configuration-interaction method and many-body perturbation theory, we estimate that a nuclear excitation rate in the range of 10 s{sup -1} can be obtained using conventional laser sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improving metastable impact electron spectroscopy and ultraviolet photoelectron spectroscopy signals by means of a modified time-of-flight separation

The separation of ultraviolet photoelectron spectroscopy (UPS) and metastable impact electron spectroscopy (MIES) is usually performed by a time-of-flight (ToF) separation using pre-set ToF for both types of signal. In this work, we present a new, improved ex situ signal separation method for the separation of MIES and UPS for every single measurement. Signal separation issues due to changes of system parameters can be overcome by changing the ToF separation and therefore allowing for the application of a wider range of measuring conditions. The method also enables to identify and achieve separation of the two signals without any time consuming calibration and the use of any special material for the calibration. Furthermore, changes made to the discharge source are described that enable to operate an existing MIES/UPS source over a broader range of conditions. This allows for tuning of the yield of UV photons and metastable rare gas atoms leading to an improved signal to noise ratio. First results of this improved setup are well in agreement with spectra reported in literature and show increased resolution and higher signal intensities for both MIE and UP spectra compared to the previous, non-optimized setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCLS in—photon out: fluorescence measurement of neon using soft x-rays

Here, we measured the fluorescence photon yield of neon upon soft x-ray ionization (~1200 eV) from the x-ray free-electron laser at Linac Coherent Light Source, and demonstrated the usage of a grazing incidence spectrometer with a variable line spacing grating to perform x-ray fluorescence spectroscopy on a gas phase system. Our measurements also allowed us to estimate the focal size of the beam from the theoretical description developed, in terms of the rate equation approximation accounting for photoionization shake off of neutral neon and double auger decay of single core holes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Signal Processing Model for Radiation Transport

This note describes the design of a simplified gamma ray transport model for use in designing a sequential Bayesian signal processor for low-count detection and classification. It uses a simple one-dimensional geometry to describe the emitting source, shield effects, and detector (see Fig. 1). At present, only Compton scattering and photoelectric absorption are implemented for the shield and the detector. Other effects may be incorporated in the future by revising the expressions for the probabilities of escape and absorption. Pair production would require a redesign of the simulator to incorporate photon correlation effects. The initial design incorporates the physical effects that were present in the previous event mode sequence simulator created by Alan Meyer. The main difference is that this simulator transports the rate distributions instead of single photons. Event mode sequences and other time-dependent photon flux sequences are assumed to be marked Poisson processes that are entirely described by their rate distributions. Individual realizations can be constructed from the rate distribution using a random Poisson point sequence generator.

42 ENGINEERING↗