Search NASA⌕ Search

SEARCH · Search NASA

Results for “software: data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Using Whisper-1.1 to guide improvements to nuclear data evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k{sub eff} of the application. Due to the fact that Whisper contains the simulated and measured k{sub eff} values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for {sup 233}U such that the agreement between the calculated and experimental k{sub eff} measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the Lawrence Livermore Microbal Detection Array at the Statens Serum Institut CRADA No. TC02189

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Statens Serum Institut to evaluate and transition the Lawrence Livermore Microarray Detection Array (LLMDA) analysis software package, the Composite Likelihood Maximization method (CLiMax) to the SSI. The SSI is a public enterprise under the Danish Ministry of Health that operates a microbiology reference laboratory for the Danish population and analyzes tens to thousands of human clinical samples annually. SSI has been collaborating with the LLNL team for several years to use the LLMDA to analyze viral and bacterial infections from human clinical samples. The collaboration has resulted in two joint publications thus far, describing improvements to LLMDA sample preparation, and the utility of the LLMDA for detecting emerging viruses in clinical samples. Under our previous collaboration, SSI has performed LLMDA experiments at their facility and then transferred the raw LLMDA data to LLNL for analysis. SSI had purchased LLMDA microarrays directly from the manufacturer, Roche NimbleGen. The main purpose of the current collaboration was to adapt the CLiMax analysis software so that it could run on a computer located at SSI. Additional effort was budgeted for LLNL staff to assist SSI with the transition and the operation of the software. The primary deliverable is the CLiMax software, installed on a computer at SSI.

59 BASIC BIOLOGICAL SCIENCES↗

Light Water Reactor Sustainability Program: Use of Time Distributions to Predict Operator Procedure Performance in Dynamic Human Reliability Analysis

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) framework affords software capable of conducting human reliability analysis (HRA) using a dynamic approach built around operating procedures (OPs) from nuclear power plants (NPPs). Previous HUNTER reports document the development of this software tool, the coupling of HUNTER to the simulator code, the collection of operator performance data by using simulators to calibrate HUNTER models, and linking HUNTER to probabilistic risk assessment (PRA) software. The present report largely addresses two topics. The first is a new function in HUNTER called the HUNTER Procedure Performance Predictor (P3). HUNTER P3 uses HUNTER’s built in Monte Carlo tools featuring human performance variability to identify potential error traps in procedures. The second topic is time distribution analysis to generate time inputs for dynamic HRA. The current analysis was performed to investigate time distributions for task primitives, which are the minimum task unit of analysis used in dynamic HRA modeling. Using the time distribution data, the elapsed time for human actions in an extended loss of AC power (ELAP) scenario is then investigated. Time data and prediction are essential for modeling procedure performance.

99 GENERAL AND MISCELLANEOUS↗

HiSpatialCluster: A novel high‐performance software tool for clustering massive spatial points

Abstract In the era of big data, spatial clustering is a very important means for geo‐data analysis. When clustering big geo‐data such as social media check‐in data, geotagged photos, and taxi trajectory points, traditional spatial clustering algorithms are facing more challenges. On the one hand, existing spatial clustering tools cannot support the clustering of massive point sets; on the other hand, there is no perfect solution for self‐adaptive spatial clustering. In order to achieve clustering of millions or even billions of points adaptively, a new spatial clustering tool—HiSpatialCluster—was proposed, in which the CFSFDP (clustering by fast search and finding density peaks) idea to find cluster centers and the DBSCAN (density‐based spatial clustering of applications with noise) idea of density‐connect filtering for classification are introduced. The tool’s source codes and other resources have been released on Github, and experimental evaluation was performed through clustering massive taxi trajectory points and Flickr geotagged photos in Beijing, China. The spatial clustering results were compared with those through K‐means and DBSCAN as well. As a spatial clustering tool, HiSpatialCluster is expected to play a fundamental role in big geo‐data research. First, this tool enables clustering adaptively on massive point datasets with uneven spatial density distribution. Second, the density‐connect filter method is applied to generate homogeneous analysis units from geotagged data. Third, the tool is accelerated by both parallel CPU and GPU computing so that millions or even billions of points can be clustered efficiently.

Chen, Yiran↗

COMBIgor: Data-Analysis Package for Combinatorial Materials Science

Combinatorial experiments involve synthesis of sample libraries with lateral composition gradients requiring spatially-resolved characterization of structure and properties. Here, due to maturation of combinatorial methods and their successful application in many fields, the modern combinatorial laboratory produces diverse and complex data sets requiring advanced analysis and visualization techniques. In order to utilize these large data sets to uncover new knowledge, the combinatorial scientist must engage in data science. For data science tasks, most laboratories adopt common-purpose data management and visualization software. However, processing and cross-correlating data from various measurement tools is no small task for such generic programs. Here we describe COMBIgor, a purpose-built open-source software package written in the commercial Igor Pro environment, designed to offer a systematic approach to loading, storing, processing, and visualizing combinatorial data sets. It includes (1) methods for loading and storing data sets from combinatorial libraries, (2) routines for streamlined data processing, and (3) data analysis and visualization features to construct figures. Most importantly, COMBIgor is designed to be easily customized by a laboratory, group, or individual in order to integrate additional instruments and data-processing algorithms. Utilizing the capabilities of COMBIgor can significantly reduce the burden of data management on the combinatorial scientist.

97 MATHEMATICS AND COMPUTING↗

MicroBooNE Public Data Sets: a Collaborative Tool for LArTPC Software Development

Among liquid argon time projection chamber (LArTPC) experiments MicroBooNE is the one that continually took physics data for the longest time (2015-2021), and represents the state of the art for reconstruction and analysis with this detector. Recently published analyses include oscillation physics results, searches for anomalies and other BSM signatures, and cross section measurements. LArTPC detectors are being used in current experiments such as ICARUS and SBND, and being planned for future experiments such as DUNE. MicroBooNE has recently released to the public two of its data sets, with the goal of enabling collaborative software developments with other LArTPC experiments and with AI or computing experts. These data sets simulate neutrino interactions on top of off-beam data, which include cosmic ray background and noise. The data sets are released in two formats: the native art/ROOT format used internally by the collaboration and familiar to other LArTPC experts, and the HDF5 format which contains reduced and simplified content and is suitable for usage by the broader community. This contribution presents the open data sets, discusses their motivation, the technical implementation, and the extensive documentation -- all inspired by FAIR principles. Finally, opportunities for collaborations are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

File format for normalizing radiological concentration exposure rate and dose rate data for the effects of radioactive decay and weathering processes

This report specifies the electronic file format that was agreed upon to be used as the file format for normalized radiological data produced by the software tool developed under this TI project. The NA-84 Technology Integration (TI) Program project (SNL17-CM-635, Normalizing Radiological Data for Analysis and Integration into Models) investigators held a teleconference on December 7, 2017 to discuss the tasks to be completed under the TI program project. During this teleconference, the TI project investigators determined that the comma-separated values (CSV) file format is the most suitable file format for the normalized radiological data that will be outputted from the normalizing tool developed under this TI project. The CSV file format was selected because it provides the requisite flexibility to manage different types of radiological data (i.e., activity concentration, exposure rate, dose rate) from other sources [e.g., Radiological Assessment and Monitoring System (RAMS), Aerial Measuring System (AMS), Monitoring and Sampling). The CSV file format also is suitable for the file format of the normalized radiological data because this normalized data can then be ingested by other software [e.g., RAMS, Visual Sampling Plan (VSP)] used by the NA-84’s Consequence Management Program.

97 MATHEMATICS AND COMPUTING↗

SU-E-QI-06: Design and Initial Validation of a Precise Capillary Phantom to Test Perfusion Systems

Purpose: To design a precise perfusion phantom mimicking capillaries of the brain vasculature which could be used to test various perfusion protocols and algorithms which generate perfusion maps. Methods: A perfusion phantom was designed in Solidworks and built using additive manufacturing. The phantom was an overall cylindrical shape of diameter and height 20mm and containing capillaries of 200μm or 300μm which were parallel and in contact making up the inside volume where flow was allowed. We created a flow loop using a peristaltic pump and contrast agent was injected manually. Digital Subtraction Angiographic images and low contrast images with cone beam CT were acquired after the contrast was injected. These images were analyzed by our own code in LabVIEW software and Time-Density Curve, MTT and TTP was calculated. Results: Perfused area was visible in the cone beam CT images; however, individual capillaries were not distinguishable. The Time-Density Curve acquired was accurate, sensitive and repeatable. The parameters MTT, and TTP offered by the phantom were very sensitive to slight changes in the TDC shape. Conclusion: We have created a robust calibrating model for evaluation of existing perfusion data analysis systems. This approach is extremely sensitive to changes in the flow due to the high temporal resolution and could be used as a golden standard to assist developers in calibrating and testing of imaging perfusion systems and software algorithms. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

10 CFR 830 Major Modification Determination for Advanced Test Reactor RDAS and LPCIS Replacement

The replacement of the ATR Control Complex's obsolete computer based Reactor Data Acquisition System (RDAS) and its safety-related Lobe Power Calculation and Indication System (LPCIS) software application is vitally important to ensure the ATR remains available to support this national mission. The RDAS supports safe operation of the reactor by providing 'real-time' plant status information (indications and alarms) for use by the reactor operators via the Console Display System (CDS). The RDAS is a computer support system that acquires analog and digital information from various reactor and reactor support systems. The RDAS information is used to display quadrant and lobe powers via a display interface more user friendly than that provided by the recorders and the Control Room upright panels. RDAS provides input to the Nuclear Engineering ATR Surveillance Data System (ASUDAS) for fuel burn-up analysis and the production of cycle data for experiment sponsors and the generation of the Core Safety Assurance Package (CSAP). RDAS also archives and provides for retrieval of historical plant data which may be used for event reconstruction, data analysis, training and safety analysis. The RDAS, LPCIS and ASUDAS need to be replaced with state-of-the-art technology in order to eliminate problems of aged computer systems, and difficulty in obtaining software upgrades, spare parts, and technical support. The major modification criteria evaluation of the project design did not lead to the conclusion that the project is a major modification. The negative major modification determination is driven by the fact that the project requires a one-for-one equivalent replacement of existing systems that protects and maintains functional and operational requirements as credited in the safety basis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Overview of New Tools to Perform Safety Analysis: BWR Station Black Out Test Case

Dynamic Probabilistic Risk Assessment (DPRA) methodologies couple system simulator codes (e.g., RELAP, MELCOR) with simulation controller codes (e.g., RAVEN, ADAPT). While system simulator codes accurately model system dynamics deterministically, simulation controller codes introduce both deterministic (e.g., system control logic, operating procedures) and stochastic (e.g., component failures, parameter uncertainties) elements into the simulation. Typically, a DPRA is performed by: 1) sampling values of a set of parameters from the uncertainty space of interest (using the simulation controller codes), and 2) simulating the system behavior for that specific set of parameter values (using the system simulator codes). For complex systems, one of the major challenges in using DPRA methodologies is to analyze the large amount of information (i.e., large number of scenarios ) generated, where clustering techniques are typically employed to allow users to better organize and interpret the data. In this paper, we focus on the analysis of a nuclear simulation dataset that is part of the Risk Informed Safety Margin Characterization (RISMC) Boiling Water Reactor (BWR) station blackout (SBO) case study. We apply a software tool that provides the domain experts with an interactive analysis and visualization environment for understanding the structures of such high-dimensional nuclear simulation datasets. Our tool encodes traditional and topology-based clustering techniques, where the latter partitions the data points into clusters based on their uniform gradient flow behavior. We demonstrate through our case study that both types of clustering techniques complement each other in bringing enhanced structural understanding of the data.

97 MATHEMATICS AND COMPUTING↗

Combustion machine learning: Principles, progress and prospects

Progress in combustion science and engineering has led to the generation of large amounts of data from large-scale simulations, high-resolution experiments, and sensors. This corpus of data offers enormous opportunities for extracting new knowledge and insights—if harnessed effectively. Machine learning (ML) techniques have demonstrated remarkable success in data analytics, thus offering a new paradigm for data-intense analyses and scientific investigations through combustion machine learning (CombML). While data-driven methods are utilized in various combustion areas, recent advances in algorithmic developments, the accessibility of open-source software libraries, the availability of computational resources, and the abundance of data have together rendered ML techniques ubiquitous in scientific analysis and engineering. This article examines ML techniques for applications in combustion science and engineering. Starting with a review of sources of data, data-driven techniques, and concepts, we examine supervised, unsupervised, and semi-supervised ML methods. Various combustion examples are considered to illustrate and to evaluate these methods. Next, we review past and recent applications of ML approaches to problems in combustion, spanning fundamental combustion investigations, propulsion and energy-conversion systems, and fire and explosion hazards. Challenges unique to CombML are discussed and further opportunities are identified, focusing on interpretability, uncertainty quantification, robustness, consistency, creation and curation of benchmark data, and the augmentation of ML methods with prior combustion-domain knowledge.

33 ADVANCED PROPULSION SYSTEMS↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

SU-C-BRD-04: Comparison of Shallow Fluence to Deep Point Dose Measurements for Spine VMAT SBRT Patient-Specific QA

Purpose: To investigate the sensitivity of traditional gamma-index-based fluence measurements for patient-specific measurements in VMAT delivered spine SBRT. Methods: The ten most recent cases for spine SBRT were selected. All cases were planned with Eclipse RapidArc for a TrueBeam STx. The delivery was verified using a point dose measurement with a Pinpoint 3D micro-ion chamber in a Standard Imaging Stereotactic Dose Verification Phantom. Two points were selected for each case, one within the target in a low dose-gradient region and one in the spinal cord. Measurements were localized using on-board CBCT. Cumulative and separate arc measurements were acquired with the ArcCheck and assessed using the SNC patient software with a 3%/3mm and 2%/2mm gamma analysis with global normalization and a 10% dose threshold. Correlations between data were determined using the Pearson Product-Moment Correlation. Results: For our cohort of patients, the measured doses were higher than calculated ranging from 2.2%–9.7% for the target and 1.0%–8.2% for the spinal cord. There was strong correlation between 3%/3mm and 2%/2mm passing rates (r=0.91). Moderate correlation was found between target and cord dose with a weak fit (r=0.67, R-Square=0.45). The cumulative ArcCheck measurements showed poor correlation with the measured point doses for both the target and cord (r=0.20, r=0.35). If the arcs are assessed separately with an acceptance criteria applied to the minimum passing rate between all arcs, a moderate negative correlation was found for the target and cord (r=−0.48, r= −0.71). The case with the highest dose difference (9.7%) received a passing rate of 97.2% for the cumulative arcs and 87.8% for the minimum with separate arcs. Conclusion: Our data suggest that traditional passing criteria using ArcCheck with cumulative measurements do not correlate well with dose errors. Separate arc analysis shows better correlation but may still miss large dose errors. Point dose verifications are recommended.

60 APPLIED LIFE SCIENCES↗

Collaboration 51 Correlation Function Analysis Suite (c51_corr_analysis) v0.1.0

This is a data analysis package designed for analyzing correlation functions generated with lattice QCD calculations. The purpose is to make a centralized software suite for use by all members of my collaboration, so that various members can spend less time developing their own analysis codes, and more time extracting the interesting physics from our calculations. There are also 3 independent collaborations that have expressed interest in using this code, so there is some expectation it will be used in the broader international lattice QCD community.

Walker-Loud, Andre↗

Ascribe XR v0.1.0

Ascribe XR is an immersive visualization software designed for scientists and engineers working with 3D data sets. Its key features include interactive exploration, multi-user collaboration, and flexible data import capabilities, supporting various formats such as meshes, volumes, and terrain maps. The software utilizes Godot, OpenXR and PC-VR technology to provide an immersive experience. Ascribe XR is used for data analysis, visualization, and collaboration in various fields, enabling users to gain deeper insights into complex data sets. Its advantages over similar technologies include its flexibility, customizability, and ease of use. Ascribe XR's interactive and immersive environment facilitates collaboration and accelerates the discovery process. Compared to traditional 2D visualization tools, Ascribe XR offers a more engaging and intuitive experience, allowing users to explore complex data sets in a more natural and interactive way. Its ability to support multi-user collaboration and flexible data import capabilities make it a versatile tool for various applications. Overall, Ascribe XR provides a unique combination of features, usability, and performance, making it an attractive solution for scientists and engineers working with 3D data sets.

Pandolfi, Ronald [Lawrence Berkeley National Labor↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

User Guide for the Plotting Software for the Los Alamos National Laboratory Nuclear Weapons Analysis Tools Version 2.0

The Los Alamos National Laboratory Plotting Software for the Nuclear Weapons Analysis Tools is a Java™ application based upon the open source library JFreeChart. The software provides a capability for plotting data on graphs with a rich variety of display options while allowing the viewer interaction via graph manipulation and scaling to best view the data. The graph types include XY plots, Date XY plots, Bar plots and Histogram plots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗