Search NASA⌕ Search

SEARCH · Search NASA

Results for “spin diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

TU-EF-BRA-03: Free Induction Decay (without the Decay) and Spin-Echo Imaging

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

TU-EF-BRA-04: Into 2, 3, and 4 Dimensions

NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm. MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other common applications of MRI exploit its capability to detect and image distinct movements of fluids: MR angiography (MRA), which rivals CT angiography but often requires no contrast medium, monitors the bulk flow of blood; functional MRI ( f MRI), distinguishes the perfusion of oxygenated blood from that of de-oxygenated, and lights up parts of the brain that are activated by a stimulus, rather like PET; and diffusion tensor imaging (DTI) indicates the diffusion of free water along tracts of axons, thereby bringing nerve trunks into view. There are variants on all of these themes, and on others as well. Magnetic Resonance Spectroscopy (MRS), for example, can perform non-invasive ‘virtual biopsies’ that allow identification of certain cancers and other lesions. And an MRI-guided needle biopsy can sample brain tissue from a region only millimeters in dimensions. MRI, however, involves deeper and more complex aspects of physics, technology, and biology than do most other imaging modalities, and it is widely considered to be correspondingly more difficult to learn. We could probably cover all of this rather comprehensively if we had 50 hours available rather than 2 ̶ but, to paraphrase a former Secretary of Defense, you tell your story in the time you have allotted. The four presenters and another physicist, Kevin King from GE, have combined their efforts to co-author a single slide show that describes essentials of MRI as simply as possible. It is obviously far from thorough, but hopefully it will succeed in explaining some of the basics in a simplified but still valid fashion; in providing a taste of the numerous capabilities and complexities of the modality; and in whetting your appetite to learn more. Part I. NMR, and Proton Density MRI of the 1D Patient (Wolbarst), begins with an introductory case study that illustrates a half dozen ways in which MRI provides valuable clinical information. It then explores the nuclear magnetic resonance (NMR) phenomenon, which underlies MRI. NMR can be introduced with either of two approaches. In the first, one thinks (loosely) of the nuclei of hydrogen atoms as (rotating and charged and therefore) magnetic objects, whose spin-axes tend to align in a strong external magnetic field, much like a compass needle. As with the Bohr atom, this spin-up/spin-down picture is a highly abridged version of the full quantum mechanical treatment, but still it leads to some useful, legitimate pictures of the NMR process occurring within a voxel: When RF photons of the correct (Larmor) frequency elevate protons in a fixed magnetic field out of their lower-energy spin state into the upper, the NMR phenomenon is indicated by the detectable absorption of RF power. With the addition of a linear gradient field along a multi-voxel, one-dimensional patient/phantom, as well, we can determine the water content of each compartment – an example of a real MRI study, albeit in 1D. Part I concludes with a discussion of the net magnetization at position x, m0(x), under conditions of dynamic thermal equilibrium, which leads into: Part II. Net Voxel Magnetization, m(x,t); T1-MRI; The MRI Device (Lemen), investigates the biophysics of the form of proton spin relaxation process characterized by the time T1. It then moves on to the creation of an MR image that displays the spatial variation in the values of this clinically relevant parameter, again in 1D. Finally, the design and workings of a clinical MRI machine are sketched, in preparation for: Part III. ‘Classical’ NMR; FID Imaging in 1D via k-Space (Yanasak) presents the second standard approach to NMR and MRI, the classical model. It focuses on the time dependence of the net nuclear magnetization, m(x,t), the overall magnetic field generated by the cohort of protons in the voxel at position x. Quite remarkably, this nuclear net magnetization itself acts in a strong magnetic field like a gyroscope in a gravitational field. This tack is better for explaining Free Induction Decay (FID), which involves a brief introduction to the Fourier transform and k-space. This leads to conventional Spin-Echo (S-E) reconstruction techniques for creating clinical images from raw data, and sets the stage for: Part IV. Spin-Echo; S-E / Spin Warp in a 2D Slice (Price) discusses application of the S- E sequence of radiofrequency pulses and gradient magnetic fields to the 1D patient. T2 is introduced but not explained. This Part also considers how to manipulate the image acquisition parameters so as to generate clinical pictures with contrast dominated by spatial variations in PD, T1, or T2. We conclude by demonstrating the spin-warp approach to imaging in 2D with a simple 2×2, 4-voxel example. Much of this material is presented in more detail in the chapter “MRI of the One-dimensional Patient, Part I”, in Advances in Medical Physics, Vol 5 (2014). Copies are on display at the Medical Physics Publishing booth. Learning Objectives: The participant will learn about the processes of NMR and T1 spin relaxation in a tissue voxel in a uniform magnetic field. The participant will learn about combining spin-up/spin-down NMR and T1 processes with a linear gradient to effect frequency-encoding of voxel spatial position. This approach can be used to create proton density and T1 MRI maps, respectively, of the contents of multi-voxel 1D phantoms. The participant will learn about how the ‘classical’ model of NMR it can generate Free Induction Decay (FID) images of 1D phantoms, which involves the use of the Fourier transform in k-space. This can lead simply into standard Spin-Echo images. The participant will learn about extending Spin-Echo imaging into 2 and more dimensions.

60 APPLIED LIFE SCIENCES↗

Millimetre-long transport of photogenerated carriers in topological insulators

Excitons are spin integer particles that are predicted to condense into a coherent quantum state at sufficiently low temperature. Here by using photocurrent imaging we report experimental evidence of formation and efficient transport of non-equilibrium excitons in Bi 2-x Sb x Se 3 nanoribbons. The photocurrent distributions are independent of electric field, indicating that photoexcited electrons and holes form excitons. Remarkably, these excitons can transport over hundreds of micrometers along the topological insulator (TI) nanoribbons before recombination at up to 40 K. The macroscopic transport distance, combined with short carrier lifetime obtained from transient photocurrent measurements, indicates an exciton diffusion coefficient at least 36 m 2 s -1 , which corresponds to a mobility of 6 × 104 m 2 V -1 s -1 at 7 K and is four order of magnitude higher than the value reported for free carriers in TIs. The observation of highly dissipationless exciton transport implies the formation of superfluid-like exciton condensate at the surface of TIs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-plane selective area InSb–Al nanowire quantum networks

Abstract Strong spin–orbit semiconductor nanowires coupled to a superconductor are predicted to host Majorana zero modes. Exchange (braiding) operations of Majorana modes form the logical gates of a topological quantum computer and require a network of nanowires. Here, we utilize an in-plane selective area growth technique for InSb–Al semiconductor–superconductor nanowire networks. Transport channels, free from extended defects, in InSb nanowire networks are realized on insulating, but heavily mismatched InP (111)B substrates by full relaxation of the lattice mismatch at the nanowire/substrate interface and nucleation of a complete network from a single nucleation site by optimizing the surface diffusion length of the adatoms. Essential quantum transport phenomena for topological quantum computing are demonstrated in these structures including phase-coherence lengths exceeding several micrometers with Aharonov–Bohm oscillations up to five harmonics and a hard superconducting gap accompanied by 2 e -periodic Coulomb oscillations with an Al-based Cooper pair island integrated in the nanowire network.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Functional and Electron Correlation on the Structure and Spectroscopy of the Al 2 O 3 (001)–H 2 O Interface

Oxide–water interfaces are ubiquitous, with many applications in industry and the environment, yet there is a great deal of controversy over their properties and microscopic structure. This controversy stems, in part, from the unique H-bond networks formed at different surface terminations and mineral compositions. Density functional theory simulations of these interfaces require an accurate description of both the oxide mineral and water in diverse H-bond environments. Thus, herein we simulate the Al 2 O 3 (001)–H 2 O interface using the PBE, PBE-TS, RPBE, SCAN, and HSE06-TS functionals to determine how calculated interfacial properties depend on the choice of functional. We find that the structure of the first few layers of water at the surface is determined by electron correlation in a way that cannot be approximated using semiemipirical van der Waals corrections. Of the functionals investigated, we find that SCAN yields the most accurate interfacial structure, dynamics, and sum frequency generation spectrum. Furthermore, SCAN leads to a reduction in the order of the 2D H-bond network of water at the alumina surface predicted by GGA functionals, leading to a significant decrease in the anisotropy of the diffusion coefficient at the surface. We emphasize the importance of using a functional which accurately describes electron correlation for more complex oxides, such as transition-metal oxides, where electron correlation may play an even greater role in determining the structure and dynamics of the oxide–water interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic couplings for molecular charge transfer: Benchmarking CDFT, FODFT, and FODFTB against high-level ab initio calculations

We introduce a database (HAB11) of electronic coupling matrix elements (H{sub ab}) for electron transfer in 11 π-conjugated organic homo-dimer cations. High-level ab inito calculations at the multireference configuration interaction MRCI+Q level of theory, n-electron valence state perturbation theory NEVPT2, and (spin-component scaled) approximate coupled cluster model (SCS)-CC2 are reported for this database to assess the performance of three DFT methods of decreasing computational cost, including constrained density functional theory (CDFT), fragment-orbital DFT (FODFT), and self-consistent charge density functional tight-binding (FODFTB). We find that the CDFT approach in combination with a modified PBE functional containing 50% Hartree-Fock exchange gives best results for absolute H{sub ab} values (mean relative unsigned error = 5.3%) and exponential distance decay constants β (4.3%). CDFT in combination with pure PBE overestimates couplings by 38.7% due to a too diffuse excess charge distribution, whereas the economic FODFT and highly cost-effective FODFTB methods underestimate couplings by 37.6% and 42.4%, respectively, due to neglect of interaction between donor and acceptor. The errors are systematic, however, and can be significantly reduced by applying a uniform scaling factor for each method. Applications to dimers outside the database, specifically rotated thiophene dimers and larger acenes up to pentacene, suggests that the same scaling procedure significantly improves the FODFT and FODFTB results for larger π-conjugated systems relevant to organic semiconductors and DNA.

74 ATOMIC AND MOLECULAR PHYSICS↗

Review of mixing length estimates and effects of toroidicity in a fluid model for turbulent transport in tokamaks

Basic aspects of turbulent transport in toroidal magnetized plasmas are discussed. In particular the fluid closure has strong effects on zonal flows which are needed to create an absorbing boundary for long wave lengths and also to obtain the Dimits nonlinear upshift. The fluid resonance in the energy equation is found to be instrumental for generating the L–H transition, the spin-up of poloidal rotation in internal transport barriers, as well as the nonlinear Dimits upshift. The difference between the linearly fastest growing mode number and the corresponding longer nonlinear correlation length is also addressed. It is found that the Kadomtsev mixing length result is consistent with the non-Markovian diagonal limit of the transport at the nonlinearly obtained correlation length.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of an 18R long-period stacking ordered structure in rapidly solidified Mg{sub 88}Y{sub 8}Zn{sub 4} alloy

The formation of the long-period stacking ordered structure (LPSO) in a Mg{sub 88}Y{sub 8}Zn{sub 4}(at%) ribbon produced by melt spinning was studied using high energy X-ray synchrotron radiation diffraction during in-situ isochronal heating and transmission electron microscopy. The microstructure of the rapidly solidified ribbons is characterised by fine magnesium grains with yttrium and zinc in solid solution and primary 18R LPSO-phase segregated at grain boundaries. Using differential scanning calorimetry, a strong exothermal peak was observed around 300 °C which was associated with the development of the 18R-type LPSO-phase in the magnesium grains. The apparent activation energy calculated using the Kissinger model was 125 KJmol{sup −1} and it is related to simultaneous diffusion of Y and Zn through magnesium basal plane. - Highlights: •The formation of the LPSO phase in rapidly solidified ribbons was studied. •The formation of the 18R LPSO starts at around 300 °C. •LPSO formation have to steps: Stacking faults along basal plane and then growth of 18R structure along the c direction.

36 MATERIALS SCIENCE↗

Dynamical Signatures of Thermotoga maritima Maltose-Binding Proteins Affected by Ligand Binding

Functional segregation among protein isoforms depends on the interplay of their overall structures and the molecular dynamics of these structures. Thermotoga maritima maltose-binding protein (tmMBP) isoforms show size-dependent differential binding of maltose and malto-oligomers while maintaining remarkable fold conservation. This differential behavior needs detailed characterization in native-like aqueous conditions to understand the effects of protein dynamics on ligand binding and recognition. Small-angle neutron scattering (SANS), neutron spin echo (NSE) spectroscopy, and dynamic light scattering (DLS) were used in conjunction with previously published computational molecular dynamics (MD) simulations to understand the dynamic behavior of tmMBPs experimentally. SANS provided information on the overall structure of the molecules, while NSE was used to determine the dynamics in the nanosecond time scale. Both tmMBP2 and tmMBP3 have a bidomain architecture linked with a flexible hinge, with the binding pocket sitting in the cleft between the two domains. tmMBP2 and tmMBP3 showed different solution dynamics, with the translational and rotational components dominating the dynamics of both systems, resulting in a clear differentiation of their diffusion pattern. A faster dynamics component was also observed and was attributed to segmental dynamics. Differences observed between the ligand-free (apo) and ligand-bound (holo) states of the two proteins are attributed to conformational entropy. Our results highlight the intricacies of how structure and dynamics can together shape binding to a repertoire of substrates in structurally similar proteins.

Diffusion↗

Toward accurate thermochemical models for transition metals : G3large basis sets for atoms Sc-Zn.

An augmented valence triple-zeta basis set, referred to as G3Large, is reported for the first-row transition metal elements Sc through Zn. The basis set is constructed in a manner similar to the G3Large basis set developed previously for other elements (H-Ar, K, Ca, Ga-Kr) and used as a key component in Gaussian-3 theory. It is based on a contraction of a set of 15s13p5d Gaussian primitives to 8s7p3d, and also includes sets of f and g polarization functions, diffuse spd functions, and core df polarization functions. The basis set is evaluated with triples-augmented coupled cluster [CCSD(T)] and Brueckner orbital [BD(T)] methods for a small test set involving energies of atoms, atomic ions, and diatomic hydrides. It performs well for the low-lying s{yields}d excitation energies of atoms, atomic ionization energies, and the dissociation energies of the diatomic hydrides. The Brueckner orbital-based BD(T) method performs substantially better than Hartree-Fock-based CCSD(T) for molecules such as NiH, where the starting unrestricted Hartree-Fock wavefunction suffers from a high degree of spin contamination. Comparison with available data for geometries of transition metal hydrides also shows good agreement. A smaller basis set without core polarization functions, G3MP2Large, is also defined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metastable phase formation and magnetic properties of the Fe-Nb system studied by atomistic modeling and ion beam mixing

With the aid of ab initio calculations, an n-body Fe-Nb embedded-atom potential is first constructed and then applied to study the crystal-to-amorphous phase transition through molecular dynamic simulations. The simulations determine that the glass-forming range of the Fe-Nb system is 18-83 at. % of Nb. In ion beam mixing experiments, five Fe-Nb multilayered films with overall compositions of Fe{sub 85}Nb{sub 15}, Fe{sub 75}Nb{sub 25}, Fe{sub 55}Nb{sub 45}, Fe{sub 25}Nb{sub 75}, and Fe{sub 15}Nb{sub 85}, respectively, are irradiated by 200 keV xenon ions to doses in the range of (1-7)x10{sup 15}Xe{sup +}/cm{sup 2}. The result shows that the Fe-Nb metallic glasses can be synthesized within a composition range of 25-75 at. % of Nb, matching reasonably well the theoretical prediction. Moreover, in the Fe{sub 55}Nb{sub 45} sample, a fcc-structured alloy phase with a large lattice constant of a{approx_equal}0.408 nm was obtained at a dose of 3x10{sup 15} Xe{sup +}/cm{sup 2} and the associated magnetic moment per Fe atom was measured to be 2.41{mu}{sub B}. The observed magnetic moment is much greater than the initial value of 1.42{mu}{sub B} in the bcc-Fe lattice and can thus serve as evidence confirming the high-spin ferromagnetic state of fcc Fe predicted by ab initio calculations. Interestingly, further irradiation induced phase separation in the Fe{sub 55}Nb{sub 45} sample, i.e., irradiation to a dose of 5x10{sup 15} Xe{sup +}/cm{sup 2} results in the growth of a fractal pattern consisting of Fe{sub 72}Nb{sub 28} nanoclusters embedded in Fe{sub 35}Nb{sub 65} matrix. The formation mechanism of the metastable phases as well as that of the fractal pattern observed in the Fe-Nb system was discussed in terms of the atomic collision theory and the well-known cluster-diffusion-limited-aggregation model.

36 MATERIALS SCIENCE↗

Negative and positive ion trapping by isotopic molecules in cryocrystals in case of solid parahydrogen containing electrons and H{sub 6}{sup +} radical cations

We performed electron spin resonance studies of trapped electrons and H{sub 6}{sup +} radical cations produced by radiolysis of solid parahydrogen (p-H{sub 2}), p-H{sub 2}-ortho-D{sub 2} (o-D{sub 2}), and p-H{sub 2}-HD mixtures. Yields of trapped electrons, H{sub 6}{sup +} radical cations, and its isotopic analogs H{sub 6-n}D{sub n}{sup +} (4{>=}n{>=}1) increased with increasing o-D{sub 2} and HD concentrations in solid p-H{sub 2}. Electrons were found trapped near an o-D{sub 2} or an HD in solid p-H{sub 2} due to the long-range charge-induced dipole and quadrupole interactions between electrons and isotopic hydrogen molecules. H{sub 6}{sup +} radical cations diffuse in solid p-H{sub 2} by repetition of H{sub 6}{sup +}+H{sub 2}{yields}H{sub 2}+H{sub 6}{sup +} and are trapped by ortho-D{sub 2} or HD to form H{sub 6-n}D{sub n}{sup +} (4{>=}n{>=}1) as isotope condensation reactions. Decay behaviors of these cations by the repetition, isotope condensation, and geminate recombination between electrons and H{sub 6-n}D{sub n}{sup +} (4{>=}n{>=}0) were reproduced by determining the corresponding reaction rate constants k{sub 1}, k{sub 2}, and k{sub 3}. Values of 0.045 and 0.0015 L mol{sup -1} min{sup -1} were obtained for k{sub 1} (H{sub 6}{sup +}+D{sub 2}{yields}H{sub 2}+H{sub 4}D{sub 2}{sup +}) and k{sub 2} (H{sub 4}D{sub 2}{sup +}+D{sub 2}{yields}H{sub 2}+H{sub 2}D{sub 4}{sup +}), respectively, and the value was quasinull for k{sub 3} (H{sub 2}D{sub 4}{sup +}+D{sub 2}{yields}H{sub 2}+D{sub 6}{sup +}). These rate constants suggest that hole mobility drastically decreased in the repetition reaction when H{sub 6}{sup +} radical cations acting as hole carriers formed H{sub 4}D{sub 2}{sup +} or H{sub 2}D{sub 4}{sup +}. HD and D{sub 2} molecules, therefore, act as electron and hole acceptors in irradiated solid p-H{sub 2}-o-D{sub 2} and p-H{sub 2}-HD mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Occupation probabilities as variables in electronic structure theory: cooper pairing, OP-NSOFT-Cs,t, and the homogeneous electron liquid

The energy functional of a novel electronic structure theory, OP-NSOFT, has as variables the natural spin orbitals (NSO) of the trial function and their joint occupation probabilities in the search for the ground state energy. When occupancy is restricted to the spin-paired NSOs of DOCI, the resulting theory, OP-NSOFT-0, scales as M 3 , with M the size of the one-electron basis set. Accurate results were obtained for small molecules, particularly near dissociation where single reference theories like DFT are inaccurate. The homogeneous electron liquid (HEL) could serve as a test bed of OP-NSOFT for condensed systems, but OP-NSOFT-0 reduces to the Hartree–Fock approximation for the HEL. Cooper pairing is introduced instead, both singlet pairing, OP-NOFT-Cs, and fully polarized triplet pairing, OP-NSOFT-Ct. The former yields 1/3 of the diffusion-Monte-Carlo correlation energy, the latter 1/2 to 1/3 with decreasing electron density for r s values between 1 and 10. Both yield the discontinuity in the single-particle occupation number required by the Luttinger theorem. Furthermore, two-state joint occupation probabilities illustrate the importance of electron–electron small-angle scattering in establishing electron correlation in the unpolarized HEL.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interface composition between Fe{sub 3}O{sub 4} nanoparticles and GaAs for spintronic applications

Recent interest in spintronic applications has necessitated the study of magnetic materials in contact with semiconductor substrates; importantly, the structure and composition of these interfaces can influence both device functionality and the magnetic properties. Nanoscale ferromagnet/semiconductor structures are of particular interest. In this study, the interface structure between a monolayer of ferromagnetic magnetite (Fe{sub 3}O{sub 4}) nanoparticles and a GaAs substrate was studied using cross-sectional transmission electron microscopy techniques. It was found that a continuous amorphous oxide interface layer separates the nanoparticles from the GaAs substrate, and that iron diffused into the interface layer forming a compositional gradient. Electron energy-loss near-edge fine structures of the O K absorption edge revealed that the amorphous oxide is composed of γ-Fe{sub 2}O{sub 3} directly underneath the Fe{sub 3}O{sub 4} nanoparticles, followed by a solid solution of Ga{sub 2}O{sub 3} and FeO and mostly Ga{sub 2}O{sub 3} when approaching the buckled oxide/substrate interface. Real-space density functional theory calculations of the dynamical form factor confirmed the experimental observations. The implication of the findings on the optimization of these structures for spin injection is discussed.

36 MATERIALS SCIENCE↗

Dynamics of water confined in lyotropic liquid crystals: Molecular dynamics simulations of the dynamic structure factor

The properties of water under confinement are of practical and fundamental interest. Here in this work we study the properties of water in the self-assembled lyotropic phases of gemini surfactants with a focus on testing the standard analysis of quasi-elastic neutron scattering (QENS) experiments. In QENS experiments the dynamic structure factor is measured and fit to models to extract the translational diffusion constant, D T , and rotational relaxation time, τ R . We test this procedure by using simulation results for the dynamic structure factor, extracting the dynamic parameters from the fit as is typically done in experiments, and comparing the values to those directly measured in the simulations. We find that the decoupling approximation, where the intermediate scattering function is assumed to be a product of translational and rotational contributions, is quite accurate. The jump-diffusion and isotropic rotation models, however, are not accurate when the degree of confinement is high. In particular, the exponential approximations for the intermediate scattering function fail for highly confined water and the values of D T and τ R can differ from the measured value by as much as a factor of two. Other models have more fit parameters, however, and with the range of energies and wave-vectors accessible to QENS, the typical analysis appears to be the best choice. In the most confined lamellar phase, the dynamics are sufficiently slow that QENS does not access a large enough time scale and neutron spin echo measurements would be a valuable technique in addition to QENS.

36 MATERIALS SCIENCE↗

Photonic and Opto-Electronic Applications of Polydiacetylene Films Photodeposited from Solution and Polydiacetylene Copolymer Networks

Polydiacetylenes (PDAS) are attractive materials for both electronic and photonic applications because of their highly conjugated electronic structures. They have been investigated for applications as both one-dimensional (linear chain) conductors and nonlinear optical (NLO) materials. One of the chief limitations to the use of PDAs has been the inability to readily process them into useful forms such as films and fibers. In our laboratory we have developed a novel process for obtaining amorphous films of a PDA derived from 2-methyl4-nitroaniline using photodeposition with Ultraviolet (UV) light from monomer solutions onto transparent substrates. Photodeposition from solution provides a simple technique for obtaining PDA films in any desired pattern with good optical quality. This technique has been used to produce PDA films that show potential for optical applications such as holographic memory storage and optical limiting, as well as third-order NLO applications such as all-optical refractive index modulation, phase modulation and switching. Additionally, copolymerization of diacetylenes with other monomers such as methacrylates provides a means to obtain materials with good processibility. Such copolymers can be spin cast to form films, or drawn by either melt or solution extrusion into fibers. These films or fibers can then be irradiated with UV to photopolymerize the diacetylene units to form a highly stable cross-linked PDA-copolymer network. If such films are electrically poled while being irradiated, they can achieve the asymmetry necessary for second-order NLO applications such as electro-optic switching. On Earth, formation of PDAs by the above mentioned techniques suffers from defects and inhomogeneities caused by convective flows that can arise during processing. By studying the formation of these materials in the reduced-convection, diffusion-controlled environment of space we hope to better understand the factors that affect their processing, and thereby, their nature and properties. Ultimately it may even be feasible to conduct space processing of PDAs for technological applications.

Paley, Mark S.↗

Rotating primary flow induction using jet-flapped blades

A new concept in ejector design is examined using primary jets exiting from a free spinning bladed rotor. This concept stems from a continuing effort in the development of Rotary-Jet thrust augmentors at George Washington University (GWU). An analysis of a Rotary-Jet rotor with jet-flapped blades is presented, identifying design trends beneficial to its performance. An experimental investigation was conducted to demonstrate the potential of this new concept. Several combinations of blade and shroud geometries were designed, fabricated and tested. The results are presented and discussed. Despite crudeness of fabrication, the maximum thrust augmentations obtained ranged from 1.55 to 2.14. These results demonstrate that this device is superior to all ejector designs tested with similar conventional passive diffusing shrouds.

Cordier, Stephane J.↗