Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistically designed experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

932 records · Page 52

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Reducing model bias in a deep learning classifier using domain adversarial neural networks in the MINERvA experiment

We present a simulation-based study using deep convolutional neural networks (DCNNs) to identify neutrino interaction vertices in the MINERvA passive targets region, and illustrate the application of domain adversarial neural networks (DANNs) in this context. DANNs are designed to be trained in one domain (simulated data) but tested in a second domain (physics data) and utilize unlabeled data from the second domain so that during training only features which are unable to discriminate between the domains are promoted. MINERvA is a neutrino-nucleus scattering experiment using the NuMI beamline at Fermilab. A-dependent cross sections are an important part of the physics program, and these measurements require vertex finding in complicated events. To illustrate the impact of the DANN we used a modified set of simulation in place of physics data during the training of the DANN and then used the label of the modified simulation during the evaluation of the DANN. In conclusion, we find that deep learning based methods offer significant advantages over our prior track-based reconstruction for the task of vertex finding, and that DANNs are able to improve the performance of deep networks by leveraging available unlabeled data and by mitigating network performance degradation rooted in biases in the physics models used for training.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial Atmospheric Transport of Particles

A new version of the Initial Atmospheric Transport (IAT) model has been developed. This report fully characterizes the new model. IAT is designed to model heat release into the atmosphere that contains contaminated particles. The heat release forms a buoyant puff or plume. Buoyancy is quickly dissipated in 10's to 100's of seconds through drag and entrainment of ambient air. The final location of contaminant particles in the atmosphere after dissipation of abnormal heat is an important input to long term transportation codes such as the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) code. Ultimately the settling of contaminants after long term transport provides a basis for estimating health consequences. In comparison to the old version, the new model includes explicit simulation of particles, newly formulated equations of motion for a rising puff, and a new plume model. The plume model releases many instances of a single puff along a single trajectory in a way that balances energy released over a longer period than would be appropriate for a single puff. The puff model has additions for vorticity, turbulence, virtual mass, drag, and entrainment. The particle model leads to direct interfacing between IAT and the long-term transport code HYSPLIT. Previously, particle locations were given a pattern based on IAT's puff trajectory with no particle simulation. Now, particles are explicitly simulated, and 3-D spatial distributions of particles are output based on final positions. Ballistic particles are thrown outward at high velocity from explosive events and tend to hit the ground before the end of the simulation. Non-ballistic particles tend to get pulled into the rising puff s ring of vorticity with some escaping to ambient conditions as buoyant energy dissipates. A new model verification and validation effort was made for the new plume model. The Wallops Island Solid Rocket Propellant (SRP) fire plume was extracted to a 3-D transient dataset. After calibration, the model performs better than previous single puff attempts. Even so, error levels in the process used to estimate location and ambient weather conditions approach 30%. This leads to the conclusion that unplanned photogrammetry evaluations of the IAT model are useful but not sufficiently accurate to quantify model parameters. Like previous attempts, the vertical motion entrainment parameters come out much too high in comparison to values for other studies in the literature. It is suspected that a new model of shear entrainment would alleviate this problem. Unfortunately, IAT already has more calibration parameters than the data comparisons thus far can resolve with statistical certainty. This underscores the need to verify and validate the IAT model using detailed CFD studies that allow ideal statistical comparison with the IAT model for hundreds of cases. Even so, validation by comparison to carefully planned experiments (i.e. with acceptable error levels) is also necessary because the dynamics of entrainment are at a sub-grid level for CFD. Though better validation and verification are most important, many new enhancements are still envisioned for future IAT development. These include particle rain out due to condensation and agglomeration of water, direct connection to the North American Mesoscale (NAM) weather dataset, dynamic weather conditions, including ambient particle entrainment into the puff, and detrainment at the puff to ambient mixing interface. In general, including detailed aerosol dynamics is the greatest coming challenge which will require an entire new sub-model in IAT. This is very important if contaminant particles change in such a way that they increase or decrease in their potential harm to the environment.

54 ENVIRONMENTAL SCIENCES↗

Space Station Biological Research Project

NASA Ames Research Center is responsible for the development of the Space Station Biological Research Project (SSBRP) which will support non-human life sciences research on the International Space Station Alpha (ISSA). The SSBRP is designed to support both basic research to understand the effect of altered gravity fields on biological systems and applied research to investigate the effects of space flight on biological systems. The SSBRP will provide the necessary habitats to support avian and reptile eggs, cells and tissues, plants and rodents. In addition a habitat to support aquatic specimens will be provided by our international partners. Habitats will be mounted in ISSA compatible racks at u-g and will also be mounted on a 2.5 m diameter centrifuge except for the egg incubator which has an internal centrifuge. The 2.5 m centrifuge will provide artificial gravity levels over the range of 0.01 G to 2 G. The current schedule is to launch the first rack in 1999, the Life Sciences glovebox and a second rack early in 2001, a 4 habitat 2.5 in centrifuge later the same year in its own module, and to upgrade the centrifuge to 8 habitats in 2004. The rodent habitats will be derived from the Advanced Animal Habitat currently under development for the Shuttle program and will be capable of housing either rats or mice individually or in groups (6 rats/group and at least 12 mice/group). The egg incubator will be an upgraded Avian Development Facility also developed for the Shuttle program through a Small Business and Innovative Research grant. The Space Tissue Loss cell culture apparatus, developed by Walter Reed Army Institute of Research, is being considered for the cell and tissue culture habitat. The Life Sciences Glovebox is crucial to all life sciences experiments for specimen manipulation and performance of science procedures. It will provide two levels of containment between the work volume and the crew through the use of seals and negative pressure. The glovebox will accommodate use by two crew persons simultaneously and the capability for real time video down-link and data acquisition. In house testbeds and Phase B studies of the centrifuge validated the concepts of vibration isolation and autobalancing systems to meet the ISSA microgravity requirements. The vibration isolation system is effective above the centrifuge rotation frequency while the autobalancing system on the rotor removes vibration at and below the rotation rate. Torque of the Station, induced by spin-up/spindown of the centrifuge, can be minimized by controlling spin-up/spin-down rates. The SSBRP and ISSA will provide the opportunity to perform long-term, repeatable and high quality science. The long duration increments available on the Station will permit multigeneration studies of both plants and animals which have not previously been possible. The u-g habitat racks and the eight habitat centrifuge will accommodate sufficient number of specimens to permit statistically significant sampling of specimens to investigate the time course of adaptation to altered gravity environments. The centrifuge will, for the first time, permit investigators to use gravity itself as a tool to investigate fundamental processes, to investigate the intensity and duration of gravity to maintain normal structure and function, to separate the effects of u-g from other environmental factors and to examine artificial gravity as a potential countermeasure for the physical deconditioning observed during space flight.

Johnson, Catherine C.↗

Search for 2 ν β β decay of Xe 136 to the 0 1 + excited state of Ba 136 with the EXO-200 liquid xenon detector

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless ββ decay of 136 Xe to the ground state of 136 Ba. We report here on a search for the two-neutrino ββ decay of 136 Xe to the first 0 + excited state, 0 + 1 , of Ba136 based on a 100 kg yr exposure of 136 Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of 1.7×10 24 yr. We find no statistically significant evidence for the 2νββ decay to the excited state resulting in a lower limit of T 2ν 1/2 (0 + → 0 + 1 ) > 6.9 ×10 23 yr at 90% CL. In conclusion, this observed limit is consistent with the estimated half-life of 2.5×10 25 yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of A Real-Time Photon Counting Optical Receiver in the Presence of Emulated Channel Fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Performance of a real-time photon counting optical receiver in the presence of emulated channel fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Improvements to a Response Surface Thermal Model for Orion Mated to the International Space Station

This study is an extension of previous work to evaluate the applicability of Design of Experiments (DOE)/Response Surface Methodology to on-orbit thermal analysis. The goal was to determine if the methodology could produce a Response Surface Equation (RSE) that predicted the thermal model temperature results within +/-10 F. An RSE is a polynomial expression that can then be used to predict temperatures for a defined range of factor combinations. Based on suggestions received from the previous work, this study used a model with simpler geometry, considered polynomials up to fifth order, and evaluated orbital temperature variations to establish a minimum and maximum temperature for each component. A simplified Outer Mold Line (OML) thermal model of the Orion spacecraft was used in this study. The factors chosen were the vehicle's Yaw, Pitch, and Roll (defining the on-orbit attitude), the Beta angle (restricted to positive beta angles from 0 to 75), and the environmental constants (varying from cold to hot). All factors were normalized from their native ranges to a non-dimensional range from -1.0 to 1.0. Twenty-three components from the OML were chosen and the minimum and maximum orbital temperatures were calculated for each to produce forty-six responses for the DOE model. A customized DOE case matrix of 145 analysis cases was developed which used analysis points at the factor corners, mid-points, and center. From this data set, RSE s were developed which consisted of cubic, quartic, and fifth order polynomials. The results presented are for the fifth order RSE. The RSE results were then evaluated for agreement with the analytical model predictions to produce a +/-3(sigma) error band. Forty of the 46 responses had a +/-3(sigma) value of 10 F or less. Encouraged by this initial success, two additional sets of verification cases were selected. One contained 20 cases, the other 50 cases. These cases were evaluated both with the fifth order RSE and with the analytical model. For the maximum temperature predictions, 12 of the 23 components had all predictions within +/-10 F and 17 were within +/-20 F. For the minimum temperature predictions, only 4 of the 23 components (the four radiator temperatures), were within the 10 F goal. The maximum temperature RSEs were then run through 59,049 screening cases. The RSE predictions were then filtered to find 55 cases that produced the hottest temperatures. These 55 cases were then analyzed using the thermal model and the results compared against the RSE predictions. As noted earlier, 12 of the 23 responses were within +/-10 F at 17 within +/-20 F. These results demonstrate that if properly formulated, an RSE can provide a reliable, fast temperature prediction. Despite this progress, additional work is needed to determine why the minimum temperatures responses and 6 of the hot temperature responses did not produce reliable RSEs. Recommend focus areas are the model itself (arithmetic vs. diffusion nodes) and seeking consultations with statistical application experts.

Miller, StephenW.↗

Diversity and Inclusion in Spacecraft Science Teams: What Do We Know and What Can We Do About It?

Introduction: Not only does the planetary science community lack diversity [1-3], the subset of the community that participates on spacecraft science team is even less diverse than the community as a whole [1, 4]. Results of 2020 Workforce Survey: Previous studies of the diversity of members of spacecraft science teams made incorrect assumptions about the nature of the data before collecting the data. Those analyses assumed a binary gender and ignored the existence of planetary scientists who are neither men nor women [4-6]. We present here results where demographic data was collected without assumptions; each individual surveyed supplied their own answers to demographic questions. The April 2020 survey of Planetary Scientists, which was conducted by the Statistical Research Center of the American Institute of Physics (AIP) and funded by the American Astronomical Society (AAS)’s Division of Planetary Science (DPS) asked participants their gender with 4 possible responses: Woman, Man, Another identify (please specify if you wish), and Prefer not to answer. 32% of respondents chose Woman, 67% chose Man and 1% chose Another gender identity [1]. The survey also asked demographic questions on race, ethnicity, LGBTQ+ identity, and disability. For a full list of questions, see https://dps.aas.org/sites/dps.aas.org/files/reports/2020/survey2020_questionnaire.pdf. In addition to demographic questions, the 2020 Workforce survey asked how many times respondents had been involved in Mission proposals as a Principal Investigator (PI) and, separately, as a Co-Investigator (CoI) [1]. Answers to questions about mission involvement were correlated with answers to demographic questions and the results show that members of historically underrepresented groups (non-white scientists, women, members of the LGBTQ+ community, and disabled scientists) were less likely to be involved in spacecraft mission proposals than were members of historically overrepresented groups [1]. The figures below show the correlated responses for four different axes of underrepresentation [1]. Note that while the figure on gender shows only Women and Men (due to the small percentage of folks answering “Another gender”), non-binary respondents are included in the LGBTQ+ community figure. Conclusion: Being part of a spacecraft science team is a goal for many planetary scientists. With it comes brand new data, more stable funding, and a sense of awe and exploration. It can lead to a cascade of opportunities from conference and public presentations, to membership in subsequent mission teams, and prestige in the community [4]. As a result, participation in spacecraft teams can be used a measure of success within the field. From the survey results, we see that members of historically excluded groups, even after they have overcome barriers to participating in the field, are still experiencing barriers to success within the field itself. Why?: The diminishing percentage of members of underrepresented groups as a career progresses has been referred to as a “leaky pipeline”. However, this fails to adequately capture the experiences of the members of these underrepresented groups as it implies a passive process. In order to capture the active processes (bias, discrimination, harassment, and other exclusionary behaviors) that contribute to low retention in the workforce, the term “Hostile Obstacle Course” is more useful [7,8]. It is these processes that need to be addressed in order to retain valued members of our community. Moving Forward: In order to broaden participation in planetary science, particularly mission science teams, we need to address conditions that create hostile workplace climates. What can mission teams and other groups do to address these conditions? First, each group/team needs to evaluate their own members to determine what specific barriers exist in their own interactions. One tool to accomplish this would be an anonymous survey designed to understand how team members feel about working within the group. Working with professionals who know how to create and analyze such surveys (often called “climate surveys” when applied to University students, for example) would ensure that the survey meets its goals and does not make assumptions that counter the meaningfulness of the results. Such professionals in EDIA (Equity, Diversity, Inclusion, and Accessibility) and workplace culture can make suggestions for policy changes that would eliminate hostile workplace conditions. Policy changes that are often suggested include instituting professional EDIA training for the team and/or for team leadership, instituting and following a code of conduct [9], including more interactive group activities in group meetings, etc. Training and information on EDIA is available for all members of the planetary science community. The first place to look would be in your University or Institution’s EDIA or human resources offices. Bystander Intervention is often offered as part of other meetings [10]. A newer offering is a Workshop on EDIA for Leaders in Planetary Science led by Julie Rathbun (first author of this abstract) and JA Grier (https://edialps.psi.edu/). This 3-day workshop gives participants the tools they need to enact positive change in their personal and professional spheres. The first workshop was help in November 2022 and another workshop will take place in the late spring 2023 with exact dates to be announced soon.

J. A. Rathbun↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volume Averaged Height Integrated Radar Reflectivity (VAHIRR) Cost-Benefit Analysis

Lightning Launch Commit Criteria (LLCC) are designed to prevent space launch vehicles from flight through environments conducive to natural or triggered lightning and are used for all U.S. government and commercial launches at government and civilian ranges. They are maintained by a committee known as the NASA/USAF Lightning Advisory Panel (LAP). The previous LLCC for anvil cloud, meant to avoid triggered lightning, have been shown to be overly restrictive. Some of these rules have had such high safety margins that they prohibited flight under conditions that are now thought to be safe 90% of the time, leading to costly launch delays and scrubs. The LLCC for anvil clouds was upgraded in the summer of 2005 to incorporate results from the Airborne Field Mill (ABFM) experiment at the Eastern Range (ER). Numerous combinations of parameters were considered to develop the best correlation of operational weather observations to in-cloud electric fields capable of rocket triggered lightning in anvil clouds. The Volume Averaged Height Integrated Radar Reflectivity (VAHIRR) was the best metric found. Dr. Harry Koons of Aerospace Corporation conducted a risk analysis of the VAHIRR product. The results indicated that the LLCC based on the VAHIRR product would pose a negligible risk of flying through hazardous electric fields. Based on these findings, the Kennedy Space Center Weather Office is considering seeking funding for development of an automated VAHIRR algorithm for the new ER 45th Weather Squadron (45 WS) RadTec 431250 weather radar and Weather Surveillance Radar-1988 Doppler (WSR-88D) radars. Before developing an automated algorithm, the Applied Meteorology Unit (AMU) was tasked to determine the frequency with which VAHIRR would have allowed a launch to safely proceed during weather conditions otherwise deemed "red" by the Launch Weather Officer. To do this, the AMU manually calculated VAHIRR values based on candidate cases from past launches with known anvil cloud LLCC violations. An automated algorithm may be developed if the analyses from past launches show VAHIRR would have provided a significant cost benefit by allowing a launch to proceed. The 45 WS at the ER and 30th Weather Squadron (30 WS) at the Western Range provided the AMU with launch weather summaries from past launches that were impacted by LLCC. The 45 WS provided summaries from 14 launch attempts and the 30 WS fkom 5. The launch attempts occurred between December 2001 and June 2007. These summaries helped the AMU determine when the LLCC were "red" due to anvil cloud. The AMU collected WSR-88D radar reflectivity, cloud-to-ground lightning strikes, soundings and satellite imagery. The AMU used step-by-step instructions for calculating VAHIRR manually as provided by the 45 WS. These instructions were used for all of the candidate cases when anvil cloud caused an LLCC violation identified in the launch weather summaries. The AMU evaluated several software programs capable of visualizing radar data so that VAHIRR could be calculated and chose GR2Analyst from Gibson Ridge Software, LLC. Data availability and lack of detail from some launch weather summaries permitted analysis of six launch attempts from the ER and none from the WR. The AMU did not take into account whether or not other weather LCC violations were occurring at the same time as the anvil cloud LLCC since the goal of this task was to determine how often VAHIRR provided relief to the anvil cloud LLCC at any time during several previous launch attempts. Therefore, in the statistics presented in this report, it is possible that even though VAHIRR provided relief to the anvil cloud LLCC, other weather LCC could have been violated not permitting the launch to proceed. The results of this cost-benefit analysis indicated VAHIRR provided relief from the anvil cloud LLCC between about 15% and 18% of the time for varying 5-minute time periods based on summaries fkom six launch attempts and would have allowed launch to proceed that were otherwise "NO GO" due to the anvil cloud LLCC if the T-0 time occurred during the anvil cloud LLCC violations.

Bauman, William H., III↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring HOD-dependent systematics for the DESI 2024 Full-Shape galaxy clustering analysis

We analyze the robustness of the DESI 2024 cosmological inference from the full shape of the galaxy power spectrum to uncertainties in the Halo Occupation Distribution (HOD) model of the galaxy-halo connection and the choice of priors on nuisance parameters. We assess variations in the recovered cosmological parameters across a range of mocks populated with different HOD models and find that shifts are often greater than 20% of the expected statistical uncertainties from the DESI data. We encapsulate the effect of such shifts in terms of a systematic covariance term, C HOD , and an additional diagonal contribution quantifying the impact of our choice of nuisance parameter priors on the ability of the effective field theory (EFT) model to correctly recover the cosmological parameters of the simulations. These two covariance contributions are designed to be added to the usual covariance term, C stat , describing the statistical uncertainty in the power spectrum measurement, in order to fairly represent these sources of systematic uncertainty. This novel approach should be more general and robust to the choice of model or additional external datasets used in cosmological fits than the alternative approach of adding systematic uncertainties to the recovered marginalised parameter posteriors. We compare the approaches within the context of a fixed ΛCDM model and demonstrate that our method gives conservative estimates of the systematic uncertainty that nevertheless have little impact on the final posteriors obtained from DESI data.

79 ASTRONOMY AND ASTROPHYSICS↗