Search NASA⌕ Search

SEARCH · Search NASA

Results for “test well”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deconvolution by finite-size-source effects of x-ray phase-contrast images

Purpose: In the hard x-ray region, the cross sections for the phase shift of low-Z elements are about 1000 times larger than the absorption ones. As a consequence, phase contrast is detectable even when absorption contrast is minimal or absent. Therefore, phase-contrast imaging could become a valid alternative to absorption contrast without delivering high dose to tissue/human body parts. Methods: To enhance the quality of phase-contrast images without increasing the dose, a possible approach could be the partial deconvolution of the finite source size effects by experimental phase-contrast images. The deconvolution procedure, the authors propose, employs the acquisition of two images on a suitable well-known test sample, one in contact and the other in phase-contrast conditions. Both acquired images are used along with a simulated phase-contrast image (obtained from the test sample in ideal conditions of pointlike source illumination) to correctly retrieve the experimental source distribution function. This information allows a generic experimental phase-contrast image, acquired in the same conditions, to be partially deconvolved by finite source size effects. Results: The performed experimental tests indicate that deconvolved images are equivalent to those which would be obtained with a source 40% smaller than the actual size. In turn, this finding is equivalent to an increase of the ''effective'' lateral spatial coherence length. The corresponding quality improvement of the phase-contrast imaging is directly deducible by the presence of many Fresnel fringes, much better visible with respect to the original experimental phase-contrast images. Conclusions: The use of a test standard sample, always possible in every experimental setup, to partially deconvolve the finite-size-source blurring effects shows that higher quality phase-contrast images could be readily available, making easier diagnoses and tissue/sample analyses. The method could give, in the future, the possibility to further lower the delivered dose to patients, organs, and tissues when compact room-sized and brilliant microfocus x-ray sources will be available for clinical applications in hospitals.

60 APPLIED LIFE SCIENCES↗

Experimental validation of the van Herk margin formula for lung radiation therapy

Purpose: To validate the van Herk margin formula for lung radiation therapy using realistic dose calculation algorithms and respiratory motion modeling. The robustness of the margin formula against variations in lesion size, peak-to-peak motion amplitude, tissue density, treatment technique, and plan conformity was assessed, along with the margin formula assumption of a homogeneous dose distribution with perfect plan conformity.Methods: 3DCRT and IMRT lung treatment plans were generated within the ORBIT treatment planning platform (RaySearch Laboratories, Sweden) on 4DCT datasets of virtual phantoms. Random and systematic respiratory motion induced errors were simulated using deformable registration and dose accumulation tools available within ORBIT for simulated cases of varying lesion sizes, peak-to-peak motion amplitudes, tissue densities, and plan conformities. A detailed comparison between the margin formula dose profile model, the planned dose profiles, and penumbra widths was also conducted to test the assumptions of the margin formula. Finally, a correction to account for imperfect plan conformity was tested as well as a novel application of the margin formula that accounts for the patient-specific motion trajectory.Results: The van Herk margin formula ensured full clinical target volume coverage for all 3DCRT and IMRT plans of all conformities with the exception of small lesions in soft tissue. No dosimetric trends with respect to plan technique or lesion size were observed for the systematic and random error simulations. However, accumulated plans showed that plan conformity decreased with increasing tumor motion amplitude. When comparing dose profiles assumed in the margin formula model to the treatment plans, discrepancies in the low dose regions were observed for the random and systematic error simulations. However, the margin formula respected, in all experiments, the 95% dose coverage required for planning target volume (PTV) margin derivation, as defined by the ICRU; thus, suitable PTV margins were estimated. The penumbra widths calculated in lung tissue for each plan were found to be very similar to the 6.4 mm value assumed by the margin formula model. The plan conformity correction yielded inconsistent results which were largely affected by image and dose grid resolution while the trajectory modified PTV plans yielded a dosimetric benefit over the standard internal target volumes approach with up to a 5% decrease in the V20 value.Conclusions: The margin formula showed to be robust against variations in tumor size and motion, treatment technique, plan conformity, as well as low tissue density. This was validated by maintaining coverage of all of the derived PTVs by 95% dose level, as required by the formal definition of the PTV. However, the assumption of perfect plan conformity in the margin formula derivation yields conservative margin estimation. Future modifications to the margin formula will require a correction for plan conformity. Plan conformity can also be improved by using the proposed trajectory modified PTV planning approach. This proves especially beneficial for tumors with a large anterior–posterior component of respiratory motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-36: Comparison of CBCT Image Quality for Manufacturer Default Imaging Modes

Purpose CBCT is being increasingly used in patient setup for radiotherapy. Often the manufacturer default scan modes are used for performing these CBCT scans with the assumption that they are the best options. To quantitatively assess the image quality of these scan modes, all of the scan modes were tested as well as options with the reconstruction algorithm. Methods A CatPhan 504 phantom was scanned on a TrueBeam Linear Accelerator using the manufacturer scan modes (FSRT Head, Head, Image Gently, Pelvis, Pelvis Obese, Spotlight, & Thorax). The Head mode scan was then reconstructed multiple times with all filter options (Smooth, Standard, Sharp, & Ultra Sharp) and all Ring Suppression options (Disabled, Weak, Medium, & Strong). An open source ImageJ tool was created for analyzing the CatPhan 504 images. Results The MTF curve was primarily dictated by the voxel size and the filter used in the reconstruction algorithm. The filters also impact the image noise. The CNR was worst for the Image Gently mode, followed by FSRT Head and Head. The sharper the filter, the worse the CNR. HU varied significantly between scan modes. Pelvis Obese had lower than expected HU values than most while the Image Gently mode had higher than expected HU values. If a therapist tried to use preset window and level settings, they would not show the desired tissue for some scan modes. Conclusion Knowing the image quality of the set scan modes, will enable users to better optimize their setup CBCT. Evaluation of the scan mode image quality could improve setup efficiency and lead to better treatment outcomes.

60 APPLIED LIFE SCIENCES↗

Universal interferometric signatures of a black hole’s photon ring

The Event Horizon Telescope image of the supermassive black hole in the galaxy M87 is dominated by a bright, unresolved ring. General relativity predicts that embedded within this image lies a thin “photon ring,” which is composed of an infinite sequence of self-similar subrings that are indexed by the number of photon orbits around the black hole. The subrings approach the edge of the black hole “shadow,” becoming exponentially narrower but weaker with increasing orbit number, with seemingly negligible contributions from high-order subrings. Here, we show that these subrings produce strong and universal signatures on long interferometric baselines. These signatures offer the possibility of precise measurements of black hole mass and spin, as well as tests of general relativity, using only a sparse interferometric array.

79 ASTRONOMY AND ASTROPHYSICS↗

Marker ReDistancing/Level Set Method for High-Fidelity Implicit Interface Tracking

A hybrid of the Front-Tracking (FT) and the Level-Set (LS) methods is introduced, combining advantages and removing drawbacks of both methods. The kinematics of the interface is treated in a Lagrangian (FT) manner, by tracking markers placed at the interface. The markers are not connected – instead, the interface topology is resolved in an Eulerian (LS) framework, by wrapping a signed distance function around Lagrangian markers each time the markers move. For accuracy and efficiency, we have developed a high-order “anchoring” algorithm and an implicit PDE-based re-distancing. We have demonstrated that the method is 3rd-order accurate in space, near the markers, and therefore 1st-order convergent in curvature; in contrast to traditional PDE-based re-initialization algorithms, which tend to slightly relocate the zero Level Set and can be shown to be non-convergent in curvature. The implicit pseudo-time discretization of the re-distancing equation is implemented within the Jacobian-Free Newton Krylov (JFNK) framework combined with ILU(k) preconditioning. We have demonstrated that the steady-state solutions in pseudo-time can be achieved very efficiently, with iterations (CFL ), in contrast to the explicit re-distancing which requires 100s of iterations with CFL . The most cost-effective algorithm is found to be a hybrid of explicit and implicit discretizations, in which we apply first 10-15 iterations with explicit discretization (to bring the initial guess to the ball of convergence for the Newton’s method) and then finishing with 2-3 implicit steps, bringing the re-distancing equation to a complete steady-state. The eigenscopy of the JFNK-ILU(k) demonstrates the efficiency of the ILU(k) preconditioner, which effectively cluster eigenvalues of the otherwise extremely ill-conditioned Jacobian matrices, thereby enabling the Krylov (GMRES) method to converge with iterations, with only a few levels of ILU fill-ins. Importantly, due to the Level Set localization, the bandwidth of the Jacobian matrix is nearly constant, and the ILU preconditioning scales as , which implies efficiency and good scalability of the overall algorithm. The numerical examples include the well-established tests for interface kinematics under translational, rotational and tearing/stretching motion. We have shown that the mass conservation is not an issue anymore, as demonstrated using the Rider&Kothe’s time-reversed tests with extreme deformation. We are able to stretch interface structures to the under-resolved/subgrid (on the chosen Eulerian mesh) scales, and recover them back without any change in shape/loss of mass.

99 GENERAL AND MISCELLANEOUS↗

Bringing Trimmed Serendipity Methods to Computational Practice in Firedrake

We present an implementation of the trimmed serendipity finite element family, using the open-source finite element package Firedrake. The new elements can be used seamlessly within the software suite for problems requiring H 1 , H (curl), or H (div)-conforming elements on meshes of squares or cubes. To test how well trimmed serendipity elements perform in comparison to traditional tensor product elements, we perform a sequence of numerical experiments including the primal Poisson, mixed Poisson, and Maxwell cavity eigenvalue problems. Overall, we find that the trimmed serendipity elements converge, as expected, at the same rate as the respective tensor product elements, while being able to offer significant savings in the time or memory required to solve certain problems.

97 MATHEMATICS AND COMPUTING↗

Reactive Flows in Porous Media: Challenges in Theoretical and Numerical Methods

We review theoretical and computational research, primarily from the past 10 years, addressing the flow of reactive fluids in porous media. The focus is on systems where chemical reactions at the solid–fluid interface cause dissolution of the surrounding porous matrix, creating nonlinear feedback mechanisms that can often lead to greatly enhanced permeability. Here, we discuss insights into the evolution of geological forms that can be inferred from these feedback mechanisms, as well as some geotechnical applications such as enhanced oil recovery, hydraulic fracturing, and carbon sequestration. Until recently, most practical applications of reactive transport have been based on Darcy-scale modeling, where averaged equations for the flow and reactant transport are solved. We summarize the successes and limitations of volume averaging, which leads to Darcy-scale equations, as an introduction to pore-scale modeling. Pore-scale modeling is computationally intensive but offers new insights as well as tests of averaging theories and pore-network models. We include recent research devoted to validation of pore-scale simulations, particularly the use of visual observations from microfluidic experiments.

wormhole formation↗

Use of W, Mo, and V Substituted Heteropolyacids for CO Mitigation in PEMFCs

A selection of eighteen different heteropolyacids (HPAs) were adsorbed onto Pt-on-carbon catalysts and investigated for enhanced proton exchange membrane fuel cell (PEMFC) anode CO tolerance. Structures tested were Keggin, Wells–Dawson, and a “Wells–Dawson sandwich.” Compositions were varied by replacing W or Mo addenda atoms with V atoms in the Keggin structures and W addenda atoms with Fe, Mn, Ni, Co, and Cu in the Wells–Dawson or Wells–Dawson sandwich structures. Of those tested, it was found that only Keggin-structured HPAs of composition H3+xPMo12-xVxO40H3+xPMo12-xVxO40 where V=0V=0 , 2, and 3 had significant activity toward CO oxidation. This performance increased with VV content. Using fuel poisoned with 100ppm100ppm CO the addition of H6PMo9V3O40H6PMo9V3O40 improved the current obtained at 0.5V0.5V to 525 from 229mA/cm2229mA/cm2 in fuel cell polarization experiments. Anode polarization experiments showed a performance improvement of about 0.360V0.360V with the addition of this same HPA. These HPAs were behaving as catalysts and were not simply improving the resistance of mass transport of the electrodes. Cyclic voltammetry demonstrated that HPAs exhibit reversible reductions and oxidations in the fuel cell electrode under PEMFC operating conditions. CO tolerance increases were only noticed for HPAs which were reduced and oxidized at low overpotentials.

08 HYDROGEN↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

DCYTB is a predictor of outcome in breast cancer that functions via iron-independent mechanisms

Background: Duodenal cytochrome b (DCYTB) is a ferrireductase that functions together with divalent metal transporter 1 (DMT1) to mediate dietary iron reduction and uptake in the duodenum. DCYTB is also a member of a 16-gene iron regulatory gene signature (IRGS) that predicts metastasis-free survival in breast cancer patients. To better understand the relationship between DCYTB and breast cancer, we explored in detail the prognostic significance and molecular function of DCYTB in breast cancer. Methods: The prognostic significance of DCYTB expression was evaluated using publicly available microarray data. Signaling Pathway Impact Analysis (SPIA) of microarray data was used to identify potential novel functions of DCYTB. The role of DCYTB was assessed using immunohistochemistry and measurements of iron uptake, iron metabolism, and FAK signaling. Results: High DCYTB expression was associated with prolonged survival in two large independent cohorts, together totaling 1610 patients (cohort #1, p = 1.6e-11, n = 741; cohort #2, p = 1.2e-05, n = 869; log-rank test) as well as in the Gene expression-based Outcome for Breast cancer Online (GOBO) cohort (p < 1.0e-05, n = 1379). High DCYTB expression was also associated with increased survival in homogeneously treated groups of patients who received either tamoxifen or chemotherapy. Immunohistochemistry revealed that DCYTB is localized on the plasma membrane of breast epithelial cells, and that expression is dramatically reduced in high-grade tumors. Surprisingly, neither overexpression nor knockdown of DCYTB affected levels of ferritin H, transferrin receptor, labile iron or total cellular iron in breast cancer cells. Because SPIA pathway analysis of patient microarray data revealed an association between DCYTB and the focal adhesion pathway, we examined the influence of DCYTB on FAK activation in breast cancer cells. These experiments reveal that DCYTB reduces adhesion and activation of focal adhesion kinase (FAK) and its adapter protein paxillin. Conclusions: DCYTB is an important predictor of outcome and is associated with response to therapy in breast cancer patients. DCYTB does not affect intracellular iron in breast cancer cells. Instead, DCYTB may retard cancer progression by reducing activation of FAK, a kinase that plays a central role in tumor cell adhesion and metastasis.

60 APPLIED LIFE SCIENCES↗

Application of maximum likelihood reconstruction of subaperture data for measurement of large flat mirrors

Interferometers accurately measure the difference between two wavefronts, one from a reference surface and the other from an unknown surface. If the reference surface is near perfect or is accurately known from some other test, then the shape of the unknown surface can be determined. We investigate the case where neither the reference surface nor the surface under test is well known. By making multiple shear measurements where both surfaces are translated and/or rotated, we obtain sufficient information to reconstruct the figure of both surfaces with a maximum likelihood reconstruction method. The method is demonstrated for the measurement of a 1.6 m flat mirror to 2 nm rms, using a smaller reference mirror that had significant figure error.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Six Tissue Transcriptomics Reveals Specific Immune Suppression in Spleen by Dietary Polyunsaturated Fatty Acids

Dietary polyunsaturated fatty acids (PUFA) are suggested to modulate immune function, but the effects of dietary fatty acids composition on gene expression patterns in immune organs have not been fully characterized. In the current study we investigated how dietary fatty acids composition affects the total transcriptome profile, and especially, immune related genes in two immune organs, spleen (SPL) and bone marrow cells (BMC). Four tissues with metabolic function, skeletal muscle (SKM), white adipose tissue (WAT), brown adipose tissue (BAT), and liver (LIV), were investigated as a comparison. Following 8 weeks on low fat diet (LFD), high fat diet (HFD) rich in saturated fatty acids (HFD-S), or HFD rich in PUFA (HFD-P), tissue transcriptomics were analyzed by microarray and metabolic health assessed by fasting blood glucose level, HOMA-IR index, oral glucose tolerance test as well as quantification of crown-like structures in WAT. HFD-P corrected the metabolic phenotype induced by HFD-S. Interestingly, SKM and BMC were relatively inert to the diets, whereas the two adipose tissues (WAT and BAT) were mainly affected by HFD per se (both HFD-S and HFD-P). In particular, WAT gene expression was driven closer to that of the immune organs SPL and BMC by HFDs. The LIV exhibited different responses to both of the HFDs. Surprisingly, the spleen showed a major response to HFD-P (82 genes differed from LFD, mostly immune genes), while it was not affected at all by HFD-S (0 genes differed from LFD). In conclusion, the quantity and composition of dietary fatty acids affected the transcriptome in distinct manners in different organs. Remarkably, dietary PUFA, but not saturated fat, prompted a specific regulation of immune related genes in the spleen, opening the possibility that PUFA can regulate immune function by influencing gene expression in this organ.

59 BASIC BIOLOGICAL SCIENCES↗

Matlab Scripts and Sample Data Associated with Water Resources Research Article

Scripts and data acquired at the Mirror Lake Research Site, cited by the article submitted to Water Resources Research: Distributed Acoustic Sensing (DAS) as a Distributed Hydraulic Sensor in Fractured Bedrock M. W. Becker(1), T. I. Coleman(2), and C. C. Ciervo(1) 1 California State University, Long Beach, Geology Department, 1250 Bellflower Boulevard, Long Beach, California, 90840, USA. 2 Silixa LLC, 3102 W Broadway St, Suite A, Missoula MT 59808, USA. Corresponding author: Matthew W. Becker (matt.becker@csulb.edu).

15 GEOTHERMAL ENERGY↗

Utah FORGE 3-2514: A Strain Sensing Array to Characterize Deformation at the FORGE Site - Workshop Presentation

This is a presentation on the Strain Sensing Array to Characterize Deformation at the FORGE Site project by Clemson University, presented by Lawrence Murdoch. The project's objective was to evaluate the feasibility of measuring and interpreting tensor strain data to improve the performance of EGS. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 8, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Injection and Production Test results and Reports from August 2024

This dataset includes results and reports from the injection/production test for wells 16A(78)-32 and 16B(78)-32 in August, 2024 at Utah FORGE. Materials include injection, post stimulation production, flow rate, gamma, temperature and pressure survey results. For the respective wells, injection and production profile results and interpretations are provided in .xlsx and .las file formats. Additionally, for both wells, preliminary and final reports are included and provide logging procedures and visualizations of the results.

15 GEOTHERMAL ENERGY↗

Emergent symmetries in atomic nuclei: Probing nuclear dynamics and physics beyond the standard model

Dominant shapes naturally emerge in atomic nuclei from first principles, thereby establishing the shape-preserving symplectic Sp(3, \mathbb{R} ℝ ) symmetry as remarkably ubiquitous and almost perfect symmetry in nuclei. We discuss the critical role of this emergent symmetry in enabling machine-learning descriptions of heavy nuclei, ab initio modeling of \alpha α clustering and collectivity, as well as tests of beyond-the-standard-model physics. In addition, the Sp(3, \mathbb{R} ℝ ) and SU(3) symmetries provide relevant degrees of freedom that underpin the ab initio symmetry-adapted no-core shell model with the remarkable capability of reaching nuclei and reaction fragments beyond the lightest and close-to-spherical species.

Launey, Kristina D.↗

Evaluation of an Electrostatic Dust Removal System with Potential Application in Next-Step Fusion Devices

The ability to manage inventories of carbon, tritium, and high-Z elements in fusion plasmas depends on means for effective dust removal. A dust conveyor, based on a moving electrostatic potential well, was tested with particles of tungsten, carbon, glass and sand. A digital microscope imaged a representative portion of the conveyor, and dust particle size and volume distributions were derived before and after operation. About 10 mm3 volume of carbon and tungsten particles were moved in under 5 seconds. The highest driving amplitude tested of 3 kV was the most effective. The optimal driving frequency was 210 Hz (maximum tested) for tungsten particles, decreasing to below 60 Hz for the larger sand particles. Measurements of particle size and volume distributions after 10 and 100 cycles show the breaking apart of agglomerated carbon, and the change in particle distribution over short timescales (<1 s).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗