Search NASA⌕ Search

SEARCH · Search NASA

Results for “value analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

aafnavcmig (a1)

This umbrella contains data from all instrumentation associated with the aircraft’s navigational location, motion, and attitude data. Navigational instrumentation on the Gulfstream-159 includes navigational data recorded from the AIMMS-20 (for other AIMMS produced data see the instrument category MET-AIR), CMigits global positioning system (GPS) & Inertial Navigational System (INS) Tactical System, Differential Survey Module (DSM), and VectorNav VN-200 INS. For a higher-order product that contains navigational data integrated with meteorological data and sampling masks/flags to aid analysis please see the categorical value added product NAVMET-AIR.

54 ENVIRONMENTAL SCIENCES↗

aafnavdsm1hz (a1)

This umbrella contains data from all instrumentation associated with the aircraft’s navigational location, motion, and attitude data. Navigational instrumentation on the Gulfstream-159 includes navigational data recorded from the AIMMS-20 (for other AIMMS produced data see the instrument category MET-AIR), CMigits global positioning system (GPS) & Inertial Navigational System (INS) Tactical System, Differential Survey Module (DSM), and VectorNav VN-200 INS. For a higher-order product that contains navigational data integrated with meteorological data and sampling masks/flags to aid analysis please see the categorical value added product NAVMET-AIR.

54 ENVIRONMENTAL SCIENCES↗

Summary

An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's material protection, control, and accountability (MPC&A) system. The MSET process is divided into four distinct and separate parts: (1) Completion of the questionnaire that assembles information about the operations of every aspect of the MPC&A system; (2) Conversion of questionnaire data into numeric values associated with risk; (3) Analysis of the numeric data utilizing the MPC&A fault tree and the SAPHIRE computer software; and (4) Self-assessment using the MSET reports to perform the effectiveness evaluation of the facility's MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. If the need for system improvements or upgrades is indicated when the system is analyzed, MSET provides the capability to evaluate potential or actual system improvements or upgrades. A facility's MC&A system can be evaluated at a point in time. The system can be reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential system improvement can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance and reveals where performance degradation has the greatest impact on total system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk. The functional model, the system risk assessment tool, and the facility evaluation questionnaire are valuable educational tools for MPC&A personnel. These educational tools provide a framework for ongoing dialogue between organizations regarding the design, development, implementation, operation, assessment, and sustainability of MPC&A systems. An organization considering the use of MSET as an analytical tool for evaluating the effectiveness of its MPC&A system will benefit from conducting a complete MSET exercise at an existing nuclear facility.

99 GENERAL AND MISCELLANEOUS↗

Investigation of Heterogeneity Effects on Calculated Sensitivities of the ZPPR-15B Assemblies

In past years, sensitivity studies of ZPR and ZPPR assemblies were carried out with deterministic codes for several purposes, such as uncertainty estimation of calculated parameter values, cross section adjustment, representativity analysis. etc. However, these sensitivity studies used simplified R-Z models of ZPR/ZPPR assemblies where the multi-group cross section data was obtained from the homogenized material compositions of each reactor zone. The main reason for this simplification was the lack of a deterministic path able to compute sensitivity coefficients for complicated 3D geometries in transport theory. Also, each ZPR and ZPPR assembly consists of several different drawers each containing different plate types and plate arrangements and it was felt that performing sensitivity calculations with an equivalent R-Z reactor model would capture most of the feedback while the heterogeneity effects were believed to be of second order. Recently a new code, BuildZPRModel, was developed at ANL that automatically generates the inputs for cross section processing and core calculation of heterogeneous ZPR and ZPPR assemblies for 3D transport calculations. Additionally, the PERSENT code (recently developed at ANL as well) is able to carry out sensitivity calculations in transport theory on 3D geometries. With the benefit of the newly developed codes, a sensitivity study was performed for the heterogeneous model of ZPPR-15B assemblies 96 and 102 generated by BuildZPRModel. The results were compared with the sensitivities computed with the use of fully homogenized R-Z reactor models, in order to quantify the impact of heterogeneity effects neglected in the analysis performed in past years.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Typical aqueous rare earth element behavior in co-produced Brines, Wyoming

Normalization of Rare Earth Elements (REEs) is important to remove the distracting effects of the Oddo–Harkins rule and provide a meaningful baseline. Normalizations for rocks are well developed and include chondritic meteorites, UCC, PM, PAAS, and NASC. However normalizations for aqueous REEs are limited to oceanic regions such as the North Pacific Deep Water or North Atlantic Surface Water. This leaves water in contact with continental lithologies without a suitable normalization. We present a preliminary continental aqueous REE normalization derived from 38 deep basin hydrocarbon brines in Wyoming. The REEs in these waters are seven orders of magnitude more dilute than NASC but with significant europium enrichment. Gromet 1984 reports NASC Eu/Eu* is 0.2179, whereas in the normalization offered here, Eu/Eu* is 3.868. These waters also are free from the distracting reduction-oxidation cerium behavior found in ocean normalizations. Because these samples exhibit both the uniform behavior of NASC and the absolute concentration of seawater, a normalization based upon them offers a unique combination of the advantages of both. We used single-peak gaussian analysis to quantify the mean values for each REE and estimate the distribution variability. Additional sample collection during the last year revealed that the Powder River Basin (PRB) is atypical relative to the other sampled basins of Wyoming. Those other basins are the Wind River Basin (WRB) Green River Basin (GRB) and Wamsutter Area (WA). A pre-normalization gadolinium anomaly (Gd/Gd*) of between 4 and 23 with a mean of 11.5, defines the PRB samples. Other basins in this study range from 1 to 7 with a mean of 2.8. Finally, we present a preliminary model for ligand-based behavior of REEs in these samples. This model identifies bicarbonate, bromide, and chloride as forming significant complexes with REEs contributing to REE solubility. The ligand model explains observed REEs in the sampled Cretaceous and Paleocene clastic reservoirs. However, the presence of more REEs than predicted in six samples suggests that there is an additional, unconsidered ligand contributing to REE dissolution. Further work will identify this ligand, which appears to be confined to calcium-cemented and dolostone systems.

02 PETROLEUM↗

Measurement of Electron Neutrino and Antineutrino Appearance with the NO{$\nu$}A Experiment

As a long-baseline neutrino oscillation experiment, the NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment aims at studying neutrino physics by measuring neutrino oscillation parameters using the neutrino flux from the Main Injector (NuMI) beam. It has two functionally identical detectors. The near detector is onsite at Fermi National Accelerator Laboratory. The far detector is 810 km away from the source of neutrinos and antineutrinos, at Ash River, Minnesota. At the near detector, muon neutrinos or antineutrinos, before significant oscillations take place, are used to correct the Monte Carlo simulation. At the far detector, the neutrino and antineutrino fluxes after significant oscillations have happened are measured and analyzed to study neutrino oscillation. The NOvA experiment is sensitive to the values of $\sin^2{\theta_{23}}$, $\Delta m^2_{32}$, and $\delta_{CP}$. The latest values from the NOvA 2020 analysis are as follows: $\sin^2{\theta_{23}}= 0.57^{+0.03}_{-0.04}$, $\Delta m^2_{32} = (2.41 \pm 0.07)\times 10^{-3}$\,eV$^2/c^4$, and $\delta_{CP}=0.82\pi$ with a wide 1$\sigma$ interval of uncertainty. My study is focused on the neutrino oscillation analysis with NOvA, including detector light model tuning, particle classification with convolutional neural network, electron neutrino and antineutrino energy reconstruction, and oscillation background estimation. Most of my studies have been used in the latest NOvA publication and the NOvA 2020 analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Heterogeneity Effects on Calculated Sensitivities of the ZPPR-15B Assemblies

In past years, sensitivity studies of ZPR and ZPPR assemblies were carried out with deterministic codes for several purposes, such as uncertainty estimation of calculated parameter values, cross section adjustment, representativity analysis. etc.. However, these sensitivity studies used simplified R-Z models of ZPR/ZPPR assemblies where the multi-group cross section data was obtained from the homogenized material compositions of each reactor zone. The main reason for this simplification was the lack of a deterministic path able to compute sensitivity coefficients for complicated 3D geometries in transport theory. Also, each ZPR and ZPPR assembly consists of several different drawers each containing different plate types and plate arrangements and it was felt that performing sensitivity calculations with an equivalent R-Z reactor model would capture most of the feedback while the heterogeneity effects were believed to be of second order. Recently a new code, BuildZPRModel, was developed at ANL that automatically generates the inputs for cross section processing and core calculation of heterogeneous ZPR and ZPPR assemblies for 3D transport calculations. Additionally, the PERSENT code (recently developed at ANL as well) is able to carry out sensitivity calculations in transport theory on 3D geometries. With the benefit of the newly developed codes, a sensitivity study was performed for the heterogeneous model of ZPPR-15B assemblies 96 and 102 generated by BuildZPRModel. The results were compared with the sensitivities computed with the use of fully homogenized R-Z reactor models, in order to quantify the impact of heterogeneity effects neglected in the analysis performed in past years. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DARWIN2 Low burnup validation for burnup credit using SFCOMPO PIE database - Verification of ICF values - 14433

The DARWIN package, developed by the CEA and its French partners (AREVA and EDF), provides the parameters required for fuel cycle applications, especially fuel inventory. It is widely used in the French Burnup Credit (BUC) calculation route, based on the connection of the depletion code DARWIN and the Criticality-Safety Package CRISTAL. The experimental validation process of BUC nuclides provided by DARWIN2.3 package consists in the comparison between JEFF-3.1.1-based calculated values of isotopic concentrations and experimental values obtained from the chemical analysis of PWR fuel rod cuts. As a complement to the extensive validation using the French PIE database, specific PIE data chosen for their quality were selected and analyzed in the SFCOMPO database of NEA. A set of 56 samples chosen in PWR-UO{sub 2} experiments was selected, with initial {sup 235}U enrichment between 2.7% and 4.1% and local burnup estimated from {sup 148}Nd measurement varying between 7 and 35 GWd/tHM. This paper provides an overview of calculation - experiment comparison obtained in Takahama-3 17x17, Trino-Vercellese 15x15 and Obrigheim 14x1 for uranium, plutonium isotopes, as well as available fission products contributing to the assembly reactivity. Consistent biases compared to SCALE5 results were obtained. From these results, an analysis is driven using 15 selected samples with low burnup, selected among asymptotic rods of irradiated fuels at 1 or 2 cycles. This paper shows the consistency of the calculation - experiment biases obtained with DARWIN2.3 towards previously defined penalized biases used for the Isotopic Correction Factors (ICF) in BUC applications. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autogenous acid production using a regulated bio-oxidation method for economical recovery of REEs and critical metals from coal-based resources

Acid is a necessary component for the successful leaching of minerals containing REEs (rare earth elements) and other sources. Pyrite (FeS2), which is present in REE containing minerals, can be used to produce acid. Pyrite is utilized as a source to create ferric sulfate and sulfuric acid in the presence of A. Ferroxidans. Such microorganism-based bio-oxidation necessitates the establishment of optimal conditions for continual acid production. For efficient acid generation, additional optimization was done by varying residence time, solid percentage, and airflow rate. A step-by-step analysis and associated details are offered in this work, which used pyrite to create acid for leaching. For the bio-oxidation of pyrite with varying purity, an automated bioreactor was used. Scanning electron microscopy with energy-dispersive X-ray spectroscopy was used to examine the morphology and elemental content of bioleaching sediments. Eh and pH measurements were continuously done to ensure healthy operation of the bioreactors. The analysis suggested that, the Eh value in the range of ∼ 640–680 mV, pH range of ∼ 1.3–1.5 and residence time of 4–6 days with 6% solid feed are favorable conditions of operation.

99 GENERAL AND MISCELLANEOUS↗

The powers of deconfinement

The trace anomaly of gluodynamics encodes the breakdown of classical scale invariance due to interactions around the deconfinement phase transition. While it is expected that at high temperatures perturbation theory becomes applicable we show that current lattice calculations are far from the perturbative regime and are dominated instead by inverse even power corrections in the temperature, while the total perturbative contribution is estimated to be extremely small and compatible with zero within error bars. We provide an interpretation in terms of dimension-two gluon condensate of the dimensionally reduced theory which value agrees with a similar analysis of power corrections from available lattice data for the renormalized Polyakov loop and the heavy quark-antiquark free energy in the deconfined phase of QCD [1,2].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PDGF family function and prognostic value in tumor biology

Highlights: • Large scale transcriptomic data analysis reveals tumor-specific roles of PDGF signaling. • Functional gene sets associated with PDGF expression are conserved between PDGF family members. • PDGF related gene signatures have increased prognostic value over each single gene. The development and progression of a tumor depends on the close interaction of malignant cells and the supportive and suppressive tumor microenvironment. Paracrine signaling enables tumor cells to shape the surrounding tissue in order to decrease recognition by the immune system, attract blood vessels to fuel growth, change metabolic programs, and induce wound healing programs. In this study, we investigate the role of the platelet-derived growth factor (PDGF) family members PDGFA, PDGFB, PDGFC and PDGFD and their cognate tyrosine kinase receptors PDGFRA and PDGFRB, using publicly available data from The Cancer Genome Atlas and the Human Protein Atlas. Large scale analysis of expression correlation in RNA sequencing data from 7616 samples derived from 16 tumor types, revealed conserved functional programs in PDGF signaling in the majority of solid tumor types. Besides the well-known effects of PDGF signaling in mesenchymal cells, our analyses revealed a potential role of PDGF signaling in the composition of the immune microenvironment. We furthermore derived gene signatures with increased prognostic value for each PDGF family member. This study emphasizes the potential to impinge on specific paracrine signaling events to interfere with the crosstalk between malignant cells and their microenvironment.

60 APPLIED LIFE SCIENCES↗

Evolution of Precipitation Particle Size Distributions within MC3E Systems and its Impact on Aerosol-Cloud-Precipitation Interactions: Final Report

This is a multi-institutional, collaborative project using observations and modeling to study the evolution (e.g. formation and growth) of hydrometeors in continental convective clouds. Our contribution was in data analysis for the generation of high-value cloud and precipitation products and derive cloud statistics for model validation. There are two areas in data analysis that we contributed: i) the development of novel, state-of-the-art dual-wavelength radar algorithms for the retrieval of cloud microphysical properties and ii) the evaluation of large domain, high-resolution models using comprehensive multi-sensor observations. Our research group developed statistical summaries from numerous sensors and developed retrievals of vertical air motion in deep convection.

54 ENVIRONMENTAL SCIENCES↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

Accuracy, criteria, and clinical significance of visual assessment on diffusion-weighted imaging and apparent diffusion coefficient quantification for diagnosing acute appendicitis

Purpose: To assess the accuracy, criteria, and clinical significance of diffusion-weighted imaging (DWI) signal intensity and apparent diffusion coefficient (ADC) quantification for diagnosing acute appendicitis. Methods: Fifty-one patients with right lower abdominal pain [uncomplicated appendicitis (n = 25), complicated appendicitis (n = 10), and non-appendicitis (n = 16)] who underwent MR examination were enrolled in this retrospective study. Two radiologists independently measured appendiceal diameter and wall thickness. They assessed whether a wall defect, an abscess, extraluminal air, or an appendicolith was present on axial T2WI; evaluated intensity on DWI using a 5-point scale; and determined the ADC values of the appendix and peri-appendiceal tissue. Statistical analysis was performed to assess imaging findings for the diagnosis of appendicitis and complicated appendicitis. Cut-off values were determined using receiver operating characteristic analysis. Results: For diagnosing acute appendicitis, the accuracy improved from 78.4% using only T2WI to 86.3% using combined T2WI and DWI for reader 1 and from 82.4 to 86.3% for reader 2. For the appendix, the cut-off ADC values that diagnosed appendicitis were 1.41 × 10{sup −3} and 1.26 × 10{sup −3} mm{sup 2}/s with accuracies of 78.4% and 76.5%, respectively. For the peri-appendiceal tissue, these values of 1.03 × 10{sup −3} and 0.91 × 10{sup −3} mm{sup 2}/s differentiated between uncomplicated and complicated appendicitis with an accuracy of 97.1%. Conclusions: Combined DWI and T2WI provided high accuracy for diagnosing appendicitis. The inflamed appendix had lower ADC value than the normal appendix. The peri-appendiceal tissue presenting low ADC value was a notable finding of complicated appendicitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Measurement of neutrino oscillations using neutrino and antineutrino beams in the NOvA experiment

NOvA is a long-baseline accelerator neutrino oscillation experiment using the NuMIneutrino beam from Fermilab. Its main physics goals are to probe the 3-flavour oscillationparameters: neutrino mass hierarchy, CP-violating phase dcp and octant of .23 mixingangle by observing electron neutrino appearance and muon neutrino disappearance. Twofunctionally identical detectors are placed off-axis from the centre of the NuMI beam.The near detector at Fermilab is 100 m underground, and the far detector is locatedon the surface at Ash River, 810 km away from the beam source. The initial neutrinobeam spectra are measured using the near detector data and the oscillation parametersare extracted by fitting the observed data to the predicted neutrino spectrum in the fardetector.This thesis is centered around how to improve the sensitivity of |.m232| and .23 measurementsin the muon neutrino disappearance analysis. NOvA will take data for about12 years. The operation of the NOvA experiment for each year costs tens of millions ofdollars, thus it is valuable to maximise the sensitivity of the analysis. Three samples ofmuon neutrino events are studied in this thesis to improve the analysis sensitivities. First,higher energy muon neutrinos are investigated by extending the energy range in NOvA’scurrent standard analysis. Second, for the sample of events used in NOvA’s existing analysis,a new energy estimator which has been developed to improve the neutrino energy resolution is considered. Furthermore, in addition to binning the events as function ofenergy and hadronic energy fraction, three particle identifiers are introduced to separateneutrino events by signal purity to reduce the effects from backgrounds. Third, an additionallower purity sample of muon neutrino charged current (CC) events that look similarto neutral current events and have not been included in NOvA’s existing analyses havebeen studied.This thesis reanalyses NOvA’s data used in the 2020 analysis, corresponding to anexposure of 13.60×1020 protons on target (POT) in the neutrino beam mode recordedfrom February 6, 2014 to March 20, 2020, and 12.50×1020 protons on target in theantineutrino beam mode recorded between June 29, 2016 to February 26, 2019. Thisthesis has implemented a fit to Asimov fake data, generated where sin2 .23 = 0.59 and.m232 = 2.5 × 10-3 eV2. These sensitivity studies show that the uncertainty range of|.m232| at 1 s in the new analysis is reduced by 5.5% and the significance of maximaldisappearance rejection improves by 7.7%, compared to the standard analysis. This isequivalent to adding 11-16% more data. The best fit values of the oscillation parametersfrom fitting to the far detector (FD) data with the new analysis are found to besin2 .23 = 0.568+0.025-0.043 (sin2 .23 = 0.454+0.046-0.026) and .m232 = 2.399+0.055-0.070 × 10-3 eV2 (.m232= -2.427+0.055-0.067 × 10-3 eV2) for the normal (inverted) hierarchy. The difference in thebest fit for sin2 .23 (.m232) between the new analysis and NOvA’s 2020 analysis is around2% (1.4%). The uncertainty range at 1 s for .m232 decrease by 8% (4%) for the normalhierarchy (inverted hierarchy) compared to the standard analysis. The uncertainty rangefor sin2 .23 is close to the standard analysis. This thesis also implements the fit from combiningelectron neutrino appearance and muon neutrino disappearance. The combinedanalysis shows that the best fit values are very close to the standard analysis. However,the uncertainty range of .m232 at 1 s is reduced by 3.7% using the new analysis. The maximaldisappearance significance is not improved in the new analysis, but the new analysisslightly improves the rejection of the disfavoured octant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗