Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

SU-D-303-03: Impact of Uncertainty in T1 Measurements On Quantification of Dynamic Contrast Enhanced MRI

Purpose: Quantification of dynamic contrast enhanced (DCE) MRI requires native longitudinal relaxation time (T1) measurement. This study aimed to assess uncertainty in T1 measurements using two different methods. Methods and Materials: Brain MRI scans were performed on a 3T scanner in 9 patients who had low grade/benign tumors and partial brain radiotherapy without chemotherapy at pre-RT, week-3 during RT (wk-3), end-RT, and 1, 6 and 18 months after RT. T1-weighted images were acquired using gradient echo sequences with 1) 2 different flip angles (50 and 150), and 2) 5 variable TRs (100–2000ms). After creating quantitative T1 maps, average T1 was calculated in regions of interest (ROI), which were distant from tumors and received a total of accumulated radiation doses < 5 Gy at wk-3. ROIs included left and right normal Putamen and Thalamus (gray matter: GM), and frontal and parietal white matter (WM). Since there were no significant or even a trend of T1 changes from pre-RT to wk-3 in these ROIs, a relative repeatability coefficient (RC) of T1 as a measure of uncertainty was estimated in each ROI using the data pre-RT and at wk-3. The individual T1 changes at later time points were evaluated compared to the estimated RCs. Results: The 2-flip angle method produced small RCs in GM (9.7–11.7%) but large RCs in WM (12.2–13.6%) compared to the saturation-recovery (SR) method (11.0–17.7% for GM and 7.5–11.2% for WM). More than 81% of individual T1 changes were within T1 uncertainty ranges defined by RCs. Conclusion: Our study suggests that the impact of T1 uncertainty on physiological parameters derived from DCE MRI is not negligible. A short scan with 2 flip angles is able to achieve repeatability of T1 estimates similar to a long scan with 5 different TRs, and is desirable to be integrated in the DCE protocol. Present study was supported by National Institute of Health (NIH) under grant numbers; UO1 CA183848 and RO1 NS064973.

60 APPLIED LIFE SCIENCES↗

Characterization of wood fiber insulation for the development of wood fiber-insulated panels (WIPs) for use in building envelope

Wood fiber insulation (WFI) was studied as an eco-friendly alternative for fossil-based building insulation, focusing on its use in new wood fiber-insulated panels (WIPs). Rigid WFI boards with densities of 110, 140, and 180 kg/m³, including a 140 kg/m³ variant without paraffin wax, were evaluated. Key properties investigated included porosity, water vapor transmission, liquid water adsorption, and thermal conductivity. The porosity ranged between 85 and 92%, primarily influenced by density. Water vapor permeability ranged from 65 to 90 ng·s-1m-1Pa-1, while liquid water absorption was between 2.5 and 20% by volume, influenced by both wax and density. The thermal conductivity coefficient ranged from 0.038 to 0.055 W/(m·K). Bond strength tests with WFI (140 kg/m³ with wax) laminated to various materials using structural adhesives showed tensile perpendicular-to-grain strengths of 10 to 16 kPa and shear strengths of 60 to 90 kPa, with failure only occurring within the WFI. It was concluded that WFI is a promising material for novel WIPs, offering competitive hygrothermal properties and compatibility with structural adhesives. However, its bio-based nature suggests variability and complexity, necessitating further rigorous testing in various climates and in more complex assemblies.

Materials Science↗

SU-E-J-67: Evaluation of Breathing Patterns for Respiratory-Gated Radiation Therapy Using Respiration Regularity Index

Purpose: Despite the importance of accurately estimating the respiration regularity of a patient in motion compensation treatment, an effective and simply applicable method has rarely been reported. The authors propose a simple respiration regularity index based on parameters derived from a correspondingly simplified respiration model. Methods: In order to simplify a patient's breathing pattern while preserving the data's intrinsic properties, we defined a respiration model as a power of cosine form with a baseline drift. According to this respiration formula, breathing-pattern fluctuation could be explained using four factors: sample standard deviation of respiration period, sample standard deviation of amplitude and the results of simple regression of the baseline drift (slope and standard deviation of residuals of a respiration signal. Overall irregularity (δ) was defined as a Euclidean norm of newly derived variable using principal component analysis (PCA) for the four fluctuation parameters. Finally, the proposed respiration regularity index was defined as ρ=ln(1+(1/ δ))/2, a higher ρ indicating a more regular breathing pattern. Subsequently, we applied it to simulated and clinical respiration signals from real-time position management (RPM; Varian Medical Systems, Palo Alto, CA) and investigated respiration regularity. Moreover, correlations between the regularity of the first session and the remaining fractions were investigated using Pearson's correlation coefficient. Results: The respiration regularity was determined based on ρ; patients with ρ<0.3 showed worse regularity than the others, whereas ρ>0.7 was suitable for respiratory-gated radiation therapy (RGRT). Fluctuations in breathing cycle and amplitude were especially determinative of ρ. If the respiration regularity of a patient's first session was known, it could be estimated through subsequent sessions. Conclusions: Respiration regularity could be objectively determined using a respiration regularity index, ρ. Such single-index testing of respiration regularity can facilitate determination of RGRT availability in clinical settings, especially for free-breathing cases. This work was supported by a Korea Science and Engineering Foundation (KOSEF) grant funded by the Korean Ministry of Science, ICT and Future Planning (No. 2013043498)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic methods for uncertainty quantification in radiation transport

The use of generalized polynomial chaos (gPC) expansions is investigated for uncertainty quantification in radiation transport. The gPC represents second-order random processes in terms of an expansion of orthogonal polynomials of random variables and is used to represent the uncertain input(s) and unknown(s). We assume a single uncertain input-the total macroscopic cross section-although this does not represent a limitation of the approaches considered here. Two solution methods are examined: The Stochastic Finite Element Method (SFEM) and the Stochastic Collocation Method (SCM). The SFEM entails taking Galerkin projections onto the orthogonal basis, which, for fixed source problems, yields a linear system of fully -coupled equations for the PC coefficients of the unknown. For k-eigenvalue calculations, the SFEM system is non-linear and a Newton-Krylov method is employed to solve it. The SCM utilizes a suitable quadrature rule to compute the moments or PC coefficients of the unknown(s), thus the SCM solution involves a series of independent deterministic transport solutions. The accuracy and efficiency of the two methods are compared and contrasted. The PC coefficients are used to compute the moments and probability density functions of the unknown(s), which are shown to be accurate by comparing with Monte Carlo results. Our work demonstrates that stochastic spectral expansions are a viable alternative to sampling-based uncertainty quantification techniques since both provide a complete characterization of the distribution of the flux and the k-eigenvalue. Furthermore, it is demonstrated that, unlike perturbation methods, SFEM and SCM can handle large parameter uncertainty.

97 MATHEMATICS AND COMPUTING↗

Empirical Estimation of Shortest Route Length along U.S. Interstate Highways Based on Great Circle Distance

In this study, 98 regression models were specified for easily estimating shortest distances based on great circle distances along the U.S. interstate highways nationwide and for each of the continental 48 states. This allows transportation professionals to quickly generate distance, or even distance matrix, without expending significant efforts on complicated shortest path calculations. For simple usage by all professionals, all models are present in the simple linear regression form. Only one explanatory variable, the great circle distance, is considered to calculate the route distance. For each geographic scope (i.e., the national or one of the states), two different models were considered, with and without the intercept. Based on the adjusted R-squared, it was observed that models without intercepts generally have better fitness. Additionally, all these models generally have good fitness with the linear regression relationship between the great circle distance and route distance. At the state level, significant variations in the slope coefficients between the state-level models were also observed. Furthermore, a preliminary analysis of the effect of highway density on this variation was conducted.

33 ADVANCED PROPULSION SYSTEMS↗

Reliability, stability during long-term storage, and intra-individual variation of circulating levels of osteopontin, osteoprotegerin, vascular endothelial growth factor-A, and interleukin-17A

Background: Studies in many populations have reported associations between circulating cytokine levels and various physiological or pathological conditions. However, the reliability of cytokine measurements in population studies, which measure cytokines in multiple assays over a prolonged period, has not been adequately examined; nor has stability during sample storage or intra-individual variation been assessed. Methods: We assessed (1) analytical reliability in short- and long-term repeated measurements; (2) stability and analytical reliability during long-term sample storage, and (3) variability within individuals over seasons, of four cytokines—osteopontin (OPN), osteoprotegerin (OPG), vascular endothelial growth factor-A (VEGF-A), and interleukin-17A (IL-17A). Measurements in plasma or serum samples were made with commercial kits according to standard procedures. Estimation was performed by fitting a random or mixed effects linear model on the log scale. Results: In repeated assays over a short period, OPN, OPG, and VEGF-A had acceptable reliability, with intra- and inter-assay coefficients of variation (CV) less than 0.11. Reliability of IL-17A was poor, with inter- and intra-assay CV 0.85 and 0.43, respectively. During long-term storage, OPG significantly decayed (-33% per year; 95% confidence interval [-54, -3.7]), but not OPN or VEGF-A (-0.3% or -6.3% per year, respectively). Intra- and inter-assay CV over a long period were comparable to that in a short period except for a slight increase in inter-assay CV of VEGF-A. Within-individual variation was small for OPN and VEGF-A, with intra-class correlations (ICC) 0.68 and 0.83, respectively, but large for OPG (ICC 0.11). Conclusions: We conclude that OPN and VEGF-A can be reliably measured in a large population, that IL-17A is suitable only for small experiments, and that OPG should be assessed with caution due to degradation during storage and intra-individual variation. The overall results of our study illustrate the need for validation under relevant conditions when measuring circulating cytokines in population studies.

60 APPLIED LIFE SCIENCES↗

Explosive Yield Estimation Using Regional Seismic Moment Tensors

Here, we use the Pasyanos and Chiang (2022) data set to calculate the seismic moment M 0 for each explosion and use the measured explosive yield W to validate the W~M 0 relationship in Denny and Johnson (1991; hereafter, DJ91). The M 0 is corrected by transforming to a potency tensor and applying more appropriate near-source geophysical parameter values in the moment estimate. The mean residual between observed and predicted yield is near zero; however, the standard deviation of the residuals results in an F-value (a 95% confidence factor) of about 5. We re-estimate the coefficients in the DJ91 model and find similar values and only a slight improvement in the F-value. Next, we embark on a similar model selection process as DJ91, allowing for non-cube-root yield scaling and other plausible near-source elastic moduli. As was found by DJ91, the yield dependence is not significantly different from unity, and a cube root assumption is valid. Therefore, we yield scale the seismic moment and test the significance of all plausible explanatory variables. Isotropic moment performs better in the response variable than total moment. The preference for isotropic moment could be due to its relationship to volume change, which would be more directly affected by explosive yield. Surprisingly, we find that the overburden pressure, which is a function of depth, is not a significant parameter in the model. We hypothesize that this is due to the competing depth effects on source asymmetry and the incorporation of depth in the Green’s functions used to calculate the seismic moment tensors. Importantly, this emphasizes that only seismic moment tensor-derived moments should be used in these models. After removing insignificant model parameters, we are left with a simple model to predict explosive yield $\widehat{W}$ in kt from isotropic moment M I in N·m, $\widehat{W}$=κ –1.4132 10 0.035626GP M I , in which κ and GP are the near-source bulk modulus and gas porosity in Pa and %, respectively. The F-value for this model is approximately 3.

58 GEOSCIENCES↗

Peculiarities of dislocation motion in aluminum with allowance for the Peierls relief in the presence of ultrasound

The effect of ultrasound on motion of the Frenkel–Kontorova dislocations in aluminum has been studied with inclusion of the Peierls relief. A dislocation moves at a variable rate when overcoming the Peierls barrier. The dislocation mean free path is changed under action of ultrasound at various frequencies comparable to the dislocation transition time to a neighboring valley. The stress–strain dependences have been obtained for high and low strain rates. In both the cases, a disordering takes place; however, the disordering rates and characters are different. At the resonance frequency, the strain resistance decreases, the hardening stage is shortened and the disordering stage is elongated. The dependence of the coefficient of hardening on coordinate has three segments different in characters. The coefficient of hardening decreases at the resonance frequency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transverse-energy-energy correlations in deep inelastic scattering

Event shape observables have been widely used for precision QCD studies at various lepton and hadron colliders. We present the most accurate calculation of the transverse-energy-energy correlation event shape variable in deep-inelastic scattering. In the framework of soft-collinear effective theory the cross section is factorized as the convolution of the hard function, beam function, jet function and soft function in the back-to-back limit. A close connection to TMD factorization is established, as the beam function when combined with part of the soft function is identical to the conventional TMD parton distribution function, and the jet function is the second moment of the TMD fragmentation function matching coefficient. We validate our framework by comparing the obtained LO and NLO leading singular distributions to the full QCD calculations in the back-to-back limit. We report the resummed transverse-energy-energy correlation distributions up to N 3 LL accuracy matched with the NLO cross section for the production of a lepton and two jets. Our work provides a new way to precisely study TMD physics at the future Electron-Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A quadratic programming flux correction method for high-order DG discretizations of S transport

In this work, we present a new flux-fixup approach for arbitrarily high-order discontinuous Galerkin (DG) discretizations of the S N transport equation, and we demonstrate the compatibility of this approach with the Variable Eddington Factor (VEF) method. The new fixup approach is sweep-compatible: during a transport sweep (block Gauss-Seidel iteration in which the scattering source is lagged), a local quadratic programming (QP) problem is solved in each spatial element to ensure that the solution satisfies certain physical constraints, including local particle balance. In this paper, we describe two choices of physical constraints, resulting in two variants of the method: QP Zero (QPZ) and QP Maximum Principle (QPMP). In QPZ, the finite element coefficients of the solution are constrained to be nonnegative. In QPMP, they are constrained to adhere to an approximate discrete maximum principle. There are two primary takeaways in this paper. First, when the positive Bernstein basis is used for DG discretization, the QPMP method eliminates negativities, preserves high-order accuracy for smooth problems, and significantly dampens unphysical oscillations in the solution. The latter feature – the dampening of unphysical oscillations – is an improvement upon standard, simpler fixup approaches such as the approach described in (denoted as the “zero and rescale” (ZR) method in this paper). This improvement comes at a moderate computational cost, but it is not prohibitive. Our results show that, even in an unrealistic worst-case scenario where 83% of the spatial elements require a fixup, the computational cost of performing a transport sweep with fixup is only ~31% greater than performing one without fixup. The second takeaway is that the VEF method can be used to accelerate the convergence of transport sweeps even when a fixup is applied. When optically thick regions are present, transport sweeps converge slowly, regardless of whether a fixup is applied, and acceleration is needed. However, attempting to apply standard diffusion synthetic acceleration (DSA) to fixed-up transport sweeps results in divergence for optically thick problems. Our results show that the same is not true for VEF. When VEF is combined with fixed-up transport sweeps, the result is a scheme that produces a nonnegative solution, converges independently of the mean free path, and, in the case of the QPMP fixup, adheres to an approximate discrete maximum principle.

97 MATHEMATICS AND COMPUTING↗

Automatic Step Size Selection in Random Walk Metropolis Algorithms

Practitioners of Markov chain Monte Carlo (MCMC) may hesitate to use random walk Metropolis- Hastings algorithms, especially variable-at-a-time algorithms with many parameters, because these algorithms require users to select values of tuning parameters (step sizes). These algorithms perform poorly if the step sizes are set to be too low or too high. We show in this paper that it is not difficult for an algorithm to tune these step sizes automatically to obtain a desired acceptance probability, since the logit of the acceptance probability is very nearly linear in the log of the step size, with known slope coefficient. These ideas work in most applications, including single parameter or block moves on the linear, log, or logit scales. We discuss the implementation of this algorithm in the software package YADAS.

97 MATHEMATICS AND COMPUTING↗

Transarterial Radioembolization Following Chemoembolization for Unresectable Hepatocellular Carcinoma: Response Based on Apparent Diffusion Coefficient Change is an Independent Predictor for Survival

PurposeTo evaluate whether response based on contrast-enhanced magnetic resonance imaging (MRI) and apparent diffusion coefficient (ADC) change at diffusion-weighted MRI after transarterial radioembolization (TARE) can predict survival, in patients with prior transarterial chemoembolization with drug-eluting beads (DEB-TACE) for hepatocellular carcinoma (HCC).MethodsWe identified all patients who received DEB-TACE prior to TARE for HCC between 2007 and 2016. Response on MRI was determined by modified RECIST (mRECIST) and ADC change relative to pre-TARE imaging (ADCratio). Kaplan–Meier and log-rank tests were used to correlate the response/disease and treatment variables to overall survival. Multivariable Cox regression models were used to correct for confounders.ResultsA total of 29 consecutive patients were included. Univariable analysis showed that response determined by mRECIST was a nonsignificant predictor of survival (p = 0.057), and response determined by ADCratio was a significant predictor of survival (p = 0.011). Number of prior DEB-TACE procedures (p = 0.037), female gender (p < 0.001) and BCLC C (p = 0.03) were related to worse survival. The number of prior DEB-TACE procedure was significantly higher in non-responders determined by ADCratio (p = 0.028). Multivariable analyses showed that response based on ADCratio was an independent predictor of survival (p = 0.041).ConclusionADCratio following TARE is an independent predictor for survival in patients who previously underwent DEB-TACE for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Why does the effective field theory of inflation work?

The effective field theory (EFT) of inflation has become the preferred method for computing cosmological correlation functions of the curvature fluctuation, ζ. It makes explicit use of the soft breaking of time diffeomorphisms by the inflationary background to organize the operators expansion in the action of the Goldstone mode π associated with this breaking. Despite its ascendancy, there is another method for calculating ζ correlators, involving the direct calculation of the so-called Horndeski action order by order in powers of ζ and its derivatives. The question we address in this work is whether or not the ζ correlators calculated in these seemingly different ways are in fact the same. The answer is that the actions to cubic order in either set of variables do indeed give rise to the same ζ bispectra, but that to make this equivalence manifest requires a careful understanding of the non-linear transformations relating π to ζ and how boundary terms in the actions are affected by imposing this relation. As a by product of our study we find that the calculations in the π language can be simplified considerably in a way that allows us to use only the linear part of the π−ζ relation simply by changing the coefficients of some of the operators in the EFT. We also note that a proper accounting of the boundary terms will be of the greatest importance when computing the bispectrum for more general initial states than the Bunch-Davies one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES↗

HIGH TEMPERATURE ANNEALING OF IRRADIATED NUCLEAR GRADE GRAPHITE

Previous work has shown that the properties of nuclear grade graphite are substantially affected by neutron irradiation. Understanding the details of how these changes occur and exactly what the damage consists of will enable prediction of the property changes as a function variables like dose, temperature, composition, micro and macrostructure. Other work has shown these atomic level changes or damage can be healed or annealed out by raising the irradiated graphite above its irradiation temperature. Experiments were carried out at the Idaho National Laboratory to investigate how the properties of irradiated graphite recover. By showing property recovery as a function of annealing temperature or energy, insight is provided into the type of damage that occurred during neutron irradiation. The data presented here shows recovery of thermal diffusivity, coefficient of thermal expansion, Young’s modulus and electrical resistivity between annealing temperatures of 500°C and 2380°C. Graphite grades NBG-18, IG-110 and PCEA are considered in both stressed and unstressed irradiation conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗