Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 937 records · Page 52

Forward velocity effects on fan noise and the suppression characteristics of advanced inlets as measured in the NASA Ames 40 by 80 foot wind tunnel: Acoustic data report

Forward velocity effects on the forward radiated fan noise and on the suppression characteristics of three advanced inlets relative to a baseline cylindrical inlet were measured in a wind tunnel. A modified JT15D turbofan engine in a quiet nacelle was the source of fan noise; the advanced inlets were a CTOL hybrid inlet, an STOL hybrid inlet, and a treated deflector inlet. Also measured were the static to flight effects on the baseline inlet noise and the effects on the fan noise of canting the baseline inlet 4 deg downward to simulate typical wing mounted turbofan engines. The 1/3 octave band noise data from these tests are given along with selected plots of 1/3 octave band spectra and directivity and full scale PNL directivities. The test facilities and data reduction techniques used are also described.

Moore, M. T.↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence R - Raw Data

Sequence R: Step AOA, No Probes (P) This sequence was designed to quantify the effect of the five-hole probes on the 3-D blade static angle-of-attack response in the presence of rotational influences by repeating Sequence K without five-hole probes. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read –99999.99. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°; the flow was allowed to stabilize; and the pitch angle was held for 5 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to ascertain the functionality of the instrumentation and repeatability over time. The file name convention used the initial letter R, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle of attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to Sequences K and L.

17 WIND ENERGY↗

High fidelity actuator line data from 9 turbine wind farm simulations using ExaWind

This data was generated with the ExaWind code suite (https://github.com/Exawind) to investigate the performance of different Active Wake Mixing turbine control in a wind farm situated in a stable atmospheric boundary layer. All cases correspond to a 3x3 wind farm in a 10km x 10km domain using a total mesh size that varied between 1.6 X 10^9 to 1.85 X 10^9 grid cells. The simulations were run across 1800-2000 GPUs on Frontier. The case description and data generation process is fully documented in Yalla, G. R., Brown, K., Cheung, L., Houck, D., deVelder, N., and Balaji, J. (2025). "Estimating annual energy production of wake mixing control strategies including comparisons to wake steering." Wind Energy Sciences (https://doi.org/10.5194/wes-2025-250).

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence S - Raw Data

Sequences S, T, and U: Upwind, No Probes (F); Upwind 2° Pitch (F); Upwind 4° Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 180° were achieved for Sequence S, but the yaw angle remained at 0° for Sequences T and U. The blade tip pitch was 3° for Sequence S, 2° for Sequence T, and 4° for Sequence U. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s for the Sequence S configuration. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YSU, followed by 00.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence T - Raw Data

Sequences S, T, and U: Upwind, No Probes (F); Upwind 2° Pitch (F); Upwind 4° Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 180° were achieved for Sequence S, but the yaw angle remained at 0° for Sequences T and U. The blade tip pitch was 3° for Sequence S, 2° for Sequence T, and 4° for Sequence U. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s for the Sequence S configuration. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YSU, followed by 00.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence U - Raw Data

Sequences S, T, and U: Upwind, No Probes (F); Upwind 2° Pitch (F); Upwind 4° Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 180° were achieved for Sequence S, but the yaw angle remained at 0° for Sequences T and U. The blade tip pitch was 3° for Sequence S, 2° for Sequence T, and 4° for Sequence U. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s for the Sequence S configuration. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YSU, followed by 00.

17 WIND ENERGY↗

Comparison of conventionally measured sea surface temperature and wind speed with data retrieved from satellite-borne microwave radiometry

The Scanning Multichannel Microwave Radiometer aboard both the Seasat and Nimbus-7 satellites was designed to estimate sea surface temperature (SST) and wind speed (WS) over an extended range of atmospheric conditions. The retrieval technique is described briefly, and it is demonstrated in a case study that the instrument design goals (SST:1.5 C; WS:2 m/s) appear to be feasible.

Hofer, R.↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence B - Raw Data

Sequences B, C, and D: Downwind Baseline (F), Downwind Low Pitch (F), Downwind High Pitch (F) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of ±180° were achieved at low wind speeds, and yaw angles of -20° to 10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence B, 0° for sequence C, and 6° for sequence D. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence C - Raw Data

Sequences B, C, and D: Downwind Baseline (F), Downwind Low Pitch (F), Downwind High Pitch (F) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of ±180° were achieved at low wind speeds, and yaw angles of -20° to 10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence B, 0° for sequence C, and 6° for sequence D. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence D - Raw Data

Sequences B, C, and D: Downwind Baseline (F), Downwind Low Pitch (F), Downwind High Pitch (F) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of ±180° were achieved at low wind speeds, and yaw angles of -20° to 10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence B, 0° for sequence C, and 6° for sequence D. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

Sodar - NREL Scintex SFAS Wind Profiler, Condon - Raw Data

The dataset includes 15-minute average wind speed and direction records from 10 m to 250 m above ground level (AGL) in 5-m range gates. Data were collected by a Scintec SFAS wind profiler installed at the Condon State Airport in Oregon, about 1.8 km northeast of the center of Condon, Ore., and are intended for validating WFIP2 model improvements.

17 WIND ENERGY↗

Sodar - NREL Scintex SFAS Wind Profiler, Condon - Reviewed Data

The dataset includes 15-minute average wind speed and direction records from 10 m to 250 m above ground level (AGL) in 5-m range gates. Data were collected by a Scintec SFAS wind profiler installed at the Condon State Airport in Oregon, about 1.8 km northeast of the center of Condon, Ore., and are intended for validating WFIP2 model improvements.

17 WIND ENERGY↗

OGCM Simulations of Equatorial Pacific Current and Temperature to ERS-1, FSU and NMC Surface Winds and to Assimilation of Subsurface Temperature Data

The relative accuracies of three surface wind data products for the tropical Pacific Ocean during April 1992 to March 1994 were examined by analyzing temperature and current fields along the equator, which were simulated with an ocean general circulation model. Simulations were made with and without assimilation of surface and subsurface temperature data. Simulated currents were compared with observations at three sites (170oW, 140oW, 110oW) at the equator. Model-generated currents and temperatures indicated that the ERS-1 westward wind speeds were low compared to the FSU and NMC winds. With data assimilation, the agreement between simulated and observed currents was highest at 170oW and lowest at 110oW.

ERS-1 FSU↗

Determination of tropical cyclone surface pressure and winds from satellite microwave data

An approach to the problem of deducing wind speed and pressure around tropical cyclones is presented. The technique, called the Surface Wind Inference from Microwave data (SWIM technique, uses satellites microwave sounder data to measure upper tropospheric temperature anomalies which may then be related to surface pressure anomalies through the hydrostatic and radiative transfer equations. Surface pressure gradients outside of the radius of maximum wind are estimated for the first time. Future instruments may be able to estimate central pressure with + or - 0/1 kPa accuracy.

Kidder, S. Q.↗

Parallelization and Visual Analysis of Multidimensional Fields: Application to Ozone Production, Destruction, and Transport in Three Dimensions

The three-dimensional, spectral transport model used in the current project was first successfully integrated over climatological time scales by Dr. Guang Ping Lou for the simulation of atmospheric N2O using the United Kingdom Meteorological Office (UKMO) 4-dimensional, assimilated wind and temperature data set. A non-parallel, FORTRAN version of this integration using a fairly simple N2O chemistry package containing only photo-chemical reactions was used to verify our initial parallel model results. The integrations reproduced the gross features of the observed stratospheric climatological N2O distributions but also simulated the structure of the stratospheric Antarctic vortex and its evolution. Subsequently, Dr. Thomas Kindler, who produced much of the parallel version of our model, enlarged the N2O model chemistry package to include N2O reactions involving O(D-1) and also introduced assimilated wind data from NASA as well as UKMO. Initially, transport calculations without chemistry were run using Carbon-14 as a non-reactive tracer gas with the result that large differences in the transport properties of the two assimilated wind data sets were apparent from the resultant Carbon-14 distributions. Subsequent calculations for N2O, including its chemistry, with the two input winds data sets with verification from UARS satellite observations have refined the transport differences between the two such that the model's steering capabilities could be used to infer the correct climatological vertical velocity fields required to support the N2O observations. During this process, it was also discovered that both the NASA and the UKMO data contained spurious values in some of the higher frequency wave components, leading to incorrect local transport calculations and ultimately affecting the large scale properties of the model's N2O distributions, particularly at tropical latitudes. Subsequent model runs with wind data that had been filtered to remove some of the high frequency components produced much more realistic N2O distributions. During the past few months, the UKMO wind data base for a complete two-year period was processed into spectral form for model use. This new version of the input transport data base now includes complete temperature fields as well as the necessary wind data. This was done to facilitate advanced chemical calculations in the parallel model which often depend upon temperature. Additional UKMO data is being added as it becomes available.

Schwan, Karsten↗