Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Density based topology optimization of turbulent flow heat transfer systems

The focus of this article is on topology optimization of heat sinks with turbulent forced convection. The goal is to demonstrate the extendibility, and the scalability of a previously developed fluid solver to coupled multi-physics and large 3D problems. The gradients of the objective and the constraints are obtained with the help of automatic differentiation applied on the discrete system without any simplifying assumptions. Thus, as demonstrated in earlier works of the authors, the sensitivities are exact to machine precision. The framework is applied to the optimization of 2D and 3D problems. Comparison between the simplified 2D setup and the full 3D optimized results is provided. A comparative study is also provided between designs optimized for laminar and turbulent flows. Overall, the comparisons highlight the importance and the benefits of full 3D optimization and including turbulence modeling in the optimization process, while also demonstrating extension of the methodology to include coupling of heat transfer with turbulent flows.

42 ENGINEERING↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 07: A mould room in a box – 3D scanning and printing technology in the radiotherapy clinic

Purpose: We describe the process by which our centre is currently implementing 3D printing and scanning technology for treatment accessory fabrication. This technology can increase efficiency and accuracy of accessory design, production and placement during daily use. Methods: A low-cost 3D printer and 3D optical scanner have been purchased and are being commissioned for clinical use. Commissioning includes assessing: the accuracy of the 3D scanner through comparison with high resolution CT images; the dosimetric characteristics of polylactic acid (PLA) for electron beams; the clinical utility of the technology, and; methods for quality assurance. Results: The agreement between meshes generated using the 3D scanner and CT data was within 2 millimeters for an anthropomorphic head phantom. In terms of electron beam attenuation, 1 centimetre of printed PLA was found equivalent to 1.17 cm of water. In proof-of-concept tests, several types of treatment accessories have been prototyped to date that will benefit from this technology. These include electron and photon bolus for areas with complex surface contours including the ear for electron treatments, the extremities for photon treatments and lead shielding for orthovoltage treatments. Imaging with CT and x-ray showed minimal defects, which will have no significant clinical impact. Geometric fidelity and fit to volunteers and patients was found to be excellent. Conclusions: 3D Printing and scanning can increase efficiency in the clinic for treatments requiring custom accessories. Customized boluses and shielding had excellent fit and reduced uncertainty in positioning.

60 APPLIED LIFE SCIENCES↗

Using Simulation to Analyze Acoustic Environments

One of the main projects that was worked on this semester was creating an acoustic model for the Advanced Space Suit in Comsol Multiphysics. The geometry tools built into the software were used to create an accurate model of the helmet and upper torso of the suit. After running the simulation, plots of the sound pressure level within the suit were produced, as seen below in Figure 1. These plots show significant nulls which should be avoided when placing microphones inside the suit. In the future, this model can be easily adapted to changes in the suit design to determine optimal microphone placements and other acoustic properties. Another major project was creating an acoustic diverter that will potentially be used to route audio into the Space Station's Node 1. The concept of the project was to create geometry to divert sound from a neighboring module, the US Lab, into Node 1. By doing this, no new audio equipment would need to be installed in Node 1. After creating an initial design for the diverter, analysis was performed in Comsol in order to determine how changes in geometry would affect acoustic performance, as shown in Figure 2. These results were used to produce a physical prototype diverter on a 3D printer. With the physical prototype, testing was conducted in an anechoic chamber to determine the true effectiveness of the design, as seen in Figure 3. The results from this testing have been compared to the Comsol simulation results to analyze how closely the Comsol results are to real-world performance. While the Comsol results do not seem to closely resemble the real world performance, this testing has provided valuable insight into how much trust can be placed in the results of Comsol simulations. A final project that was worked on during this tour was the Audio Interface Unit (AIU) design for the Orion program. The AIU is a small device that will be used for as an audio communication device both during launch and on-orbit. The unit will have functions including push-to-talk buttons and volume control. With this project, an existing design was modified based on prior feedback that had been received. With the modified design, I created a 3D printed prototype, shown in Figure 4, which was then used in suited evaluations performed by crew members. The feedback received from those evaluations will be utilized to help create the best possible Orion AIU. As a whole, a number of different interesting engineering projects were worked on over the course of this semester. For many of these projects, acoustic simulations provided valuable insight into how different environments would respond to sound. While work is still underway to verify the results of these simulations, the results are fascinating because of the interesting ways that sound waves interact with the environment. Going forward, it will be interesting to see how closely these results can be matched by real-world test data.

Wood, Eric J.↗

The aerodynamic characteristics of vortex ingestion for the F/A-18 inlet duct

A Reduced Navier-Stokes (RNS) solution technique was successfully combined with the concept of partitioned geometry and mesh generation to form a very efficient 3D RNS code aimed at the analysis-design engineering environment. Partitioned geometry and mesh generation is a pre-processor to augment existing geometry and grid generation programs which allows the solver to (1) recluster an existing gridlife mesh lattice, and (2) perturb an existing gridfile definition to alter the cross-sectional shape and inlet duct centerline distribution without returning to the external geometry and grid generator. The present results provide a quantitative validation of the initial value space marching 3D RNS procedure and demonstrates accurate predictions of the engine face flow field, with a separation present in the inlet duct as well as when vortex generators are installed to supress flow separation. The present results also demonstrate the ability of the 3D RNS procedure to analyze the flow physics associated with vortex ingestion in general geometry ducts such as the F/A-18 inlet. At the conditions investigated, these interactions are basically inviscid like, i.e., the dominant aerodynamic characteristics have their origin in inviscid flow theory.

Anderson, Bernhard H.↗

Self-balancing, long reach robotic arm

Vital accelerator components are difficult to inspect and troubleshoot when they fail. Theuse of a self-balancing, long articulating robot simplifies the identification and troubleshootingof broken components in the narrow places of the beamline by pinpointing the location of theseerrors due to its ability to maneuver through these limited spaces. The design of the long reachrobot is the second iteration of a previous model accomplished by interns Amanda Hoeksemaand Brenda Sanchez. This new robot was redesigned with a greater focus on safety and structural integrity by removing 3D-printed parts in load-bearing positions and switching to off-the-shelf components with manufacturer-specified capabilities. These changes ensure that the new robotic arm and counterbalance designs conform closer to safety regulations by not depending on the vague durability of 3D-printed parts. This design change necessitated new calculations for the arm and counterweight to ensure the robot will function as intended.

Hoeksema, Amanda↗

MAC: Memory Access Coalescer for 3D-Stacked Memory

Emerging data-intensive applications, such as graph analytics and data mining, exhibit irregular memory access patterns. Research has shown that with these memory-bound applications, traditional cache-based processor architectures, which exploit locality and regular patterns to mitigate the memory-wall issue, are inefficient. Meantime, novel 3D-stacked memory devices, such as Hybrid Mem- ory Cube (HMC) and High Bandwidth Memory (HBM), promise significant increases in bandwidth that appear extremely appealing for memory-bound applications. However, conventional memory interfaces designed for cache-based architectures and JEDEC DDR devices fit poorly with the 3D-stacked memory, which leads to significant under-utilization of the promised high bandwidth. As a response to these issues, in this paper we propose MAC (Memory Access Coalescer), a coalescing unit for the 3D-stacked memory. We discuss the design and implementation of MAC, in the context of a custom designed cache-less architecture targeted at data-intensive, irregular applications. Through a custom simulation infrastructure based on the RISC-V toolchain, we show that MAC achieves a coalescing efficiency of 52.85% on average. It improves the performance of the memory system by 60.73% on average for a large set of irregular workloads.

Wang, Xi↗

LArPix: demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers

In this work, we report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs) . Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K . Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (0<50 e - RMS equivalent noise charge) and very low-power (<100 μW/channel) ionization signal detection and readout . The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE) .

47 OTHER INSTRUMENTATION↗

Analysis of NSTX Upgrade OH Magnet and Center Stack

The new ohmic heating (OH) coil and center stack for the National Spherical Torus Experiment (NSTX) upgrade are required to meet cooling and structural requirements for operation at the enhanced 1 Tesla toroidal field and 2 MA plasma current. The OH coil is designed to be cooled in the time between discharges by water flowing in the center of the coil conductor. We performed resistive heating and thermal hydraulic analyses to optimize coolant channel size to keep the coil temperature below 100 C and meet the required 20 minute cooling time. Coupled electromagnetic, thermal and structural FEA analyses were performed to determine if the OH coil meets the requirements of the structural design criteria. Structural response of the OH coil to its self-field and the field from other coils was analyzed. A model was developed to analyze the thermal and electromagnetic interaction of centerstack components such as the OH coil, TF inner legs and the Bellville washer preload mechanism. Torsional loads from the TF interaction with the OH and poloidal fields are transferred through the TF flag extensions via a torque transfer coupling to the rest of the tokamak structure. A 3D FEA analysis was performed to qualify this design. The results of these analyses, which will be presented in this paper, have led to the design of OH coil and centerstack components that meet the requirements of the NSTX-upgrade structural design criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-330: To Analyze the Calculation Error of Live Dose-Volume Indices Applying 4D-CT in Radiotherapy for PTVs Within the Liver Completely

Purpose: To study the variation rule of normal liver dose-volume indices calculation for the liver malignancy patients whose plan target volumes were in the liver completely in all breath phases. Methods: Ten patients who accepted radiotherapy for malignant tumor were selected in our study. All patients underwent 4D-CT simulation and 3D-CT simulation in free breathing(FB). 4D-CT was sorted into 10 series CT images according to breath phase, named CT0, CT10 to CT90, respectively. And GTVs were contoured on different CT series, and the individual target volume(ITV) was obtained by merging 10 GTVs from 4D-CT. The PTVs were obtained from ITV applying margins. The PTVs were not beyond the boundary of liver in all breath phase observed by dynamic 4D-CT. The radiotherapy plans were designed and irradiation dose was calculated on 3D-CT images, and the livers were contoured on different series CT images and mapped to 3D-CT images applying rigid registration. To compare the dose-volume difference of livers based on distinct CT images. Results: (1)The liver volumes were similar on 4D-CT and 3D-CT images(CTFB 1485±500cm{sup 3}, CT0 1413±377cm{sup 3}, CT10 1409±396cm{sup 3}, CT20 1419±418cm{sup 3},CT30 1485±500cm{sup 3}, CT40 1438±392cm{sup 3}, CT50 1437±404cm{sup 3}, CT60 1439±409cm{sup 3}, CT70 1408±393cm{sup 3}, CT80 1384±397cm{sup 3}, CT90 1398±397cm{sup 3}; F=0.064,p=1.00) (2) The PTVs volume were 30.17±14.62cm{sup 3};(3) The mean dose and V5 to V10 of liver were similar among 4D-CT different series CT images(p>0.05), and the indices varied less than ±4% refer to liver on CT50. Conclusion: The calculation affection of liver dose-volume indices induced by breath motion were not significant for the PTV within liver completely as estimation before. And more objective prediction indices for radiation induced l.

60 APPLIED LIFE SCIENCES↗

SU-E-T-605: A New Design for a Rotating Gamma Knife. Monte Carlo Simulation

Purpose: to determine the characteristics of the 60Co beam emerging from a new design of a rotating Gamma Knife system and to calculate 3D dose distributions at the isocenter for different source configurations and collimator openings. Methods: We employed the BEAM-Monte Carlo code to realistically model the geometry design, including 30 60Co source capsules, two circular primary collimators (diameter of 6.6mm and 6.1mm) and four different changeable collimators. The shielding of the head design was also simulated. The sources (2.8mm diameter) are distributed in six groups in the spherical geometry. Each source is individually collimated to obtained four different circular fields at the isocenter (3mm, 3.5mm, 6mm and 8mm).The phase-space particles reaching the scoring plane below the primary collimation assembly were recorded and the BEAMDP code was used to determine the fluence and energy spectra of the particles emerging from each source-collimator configuration. The dose distributions at the isocenter plane (397.6mm from the source) were calculated in a spherical component module for the circular field sizes studied. Results: The energy spectra below the head assembly and primary collimators have been obtained, which exhibited the typical 60Co peaks and a small low-energy tail due to scattered photons (from about 200keV to 1MeV). The scattered component of the spectra represents about 8 % of the total number of photons reaching the scoring plane. The radial photon fluence does not vary significantly inside the collimator openings. The spectra of particles from different source groups are compared. Conclusion: The 60Co beam emerging from each source configuration was characterized, which can be used to establish a generic source model for all the sources for fast MC dose calculation. Further investigations are needed to determine the dose variations as a result of partial switching on/off different groups of sources for advanced Gamma Knife SRS/SBRT planning.

07 ISOTOPE AND RADIATION SOURCES↗

High Thermopower in a Zn-Based 3D Semiconductive Metal–Organic Framework

Conductive metal–organic frameworks (c-MOFs) have drawn increasing attention for their outstanding performance in energy-related applications. However, the majority of reported c-MOFs are based on 2D structures. Synthetic strategies for 3D c-MOFs are under-explored, leaving unrealized functionality in both their structures and properties. Here in this paper we report a 3D c-MOF, namely Zn-HAB, designed through topological analysis. Comprising a nitrogen donor linker, hexaaminobenzene, and Zn(II) node, Zn-HAB was found to have microporosity with a band-gap of approximately 1.68 eV. The relatively large band-gap results in a modest conduc-tivity of 0.86 mS cm -1 and a high Seebeck coefficient of 200 μV K -1 at 300 K. The power factor of 3.44 nW m -1 K -2 constitutes the first report of the thermoelectric properties of an intrinsically conductive 3D MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning system (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.

60 APPLIED LIFE SCIENCES↗

3D Printed “Earable” Smart Devices for Real-Time Detection of Core Body Temperature

Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable "earable" smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.

47 OTHER INSTRUMENTATION↗

Conceptual design of a superconducting quadrupole with elliptical acceptance and tunable higher order multipoles.

For charged particle beams that are wider in the dispersive plane compared to the transverse plane it is cost efficient to utilize magnets that accept beams with elliptic cross section. In this paper we presents the conceptual design of a quadrupole magnet with elliptic cross section and with tunable higher order multipoles. The design consists of 18 superconducting race-track coils placed on two hollow concentric rhombic prism support structures. To compute the magnetic field for the proposed design a new method of calculating 2D and 3D fields for the air core magnets based on differential algebra (DA) techniques is developed. We will present the new method and discuss its implementation of new numerical tools based on this method in the code COSY Infinity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D-Printed Graded Electrode with Ultrahigh MnO 2 Loading for Non-Aqueous Electrochemical Energy Storage

Electrolytic manganese dioxide is one of the promising cathode candidates for electrochemical energy storage devices due to its high redox capacity and ease of synthesis. Yet, high-loading MnO 2 often suffers from sluggish reaction kinetics, especially in non-aqueous electrolytes. The non-uniform deposition of MnO 2 on a porous current collectors also makes it difficult to fully utilize the active materials at high mass loading. Here, a 3D printed graded graphene aerogel (3D GA) that contains sparsely separated exterior ligaments is developed to create large open channels for mass transport as well as densely arranged interior ligaments providing large ion-accessible active surface. The unique structural design homogenizes the thickness of electro deposited MnO 2 even at an ultrahigh mass loading of ≈70 mg cm -2 . The electrode achieves a remarkable volumetric capacity of 29.1 mA h cm -3 in the non-aqueous electrolyte. A Li-ion hybrid capacitor device assembled with a graded 3D GA/MnO2 cathode and graded 3D GA/VO x anode exhibits a wide voltage window of 0–4 V and a superior volumetric energy density of 20.2 W h L -1 . The findings offer guidance on 3D printed electrode design for supporting ultrahigh loading of active materials and developments of high energy density energy storage devices.

electrochemical energy storage↗

Direct 3D Printing of Catalytically Active Structures

3D printing of materials with active functional groups can provide custom-designed structures that promote chemical conversions. Catalytically active architectures were produced by photopolymerizing bifunctional molecules using a commercial stereolithographic 3D printer. Functionalities in the monomers included a polymerizable vinyl group to assemble the 3D structures and a secondary group to provide them with active sites. The 3D-printed architectures containing accessible carboxylic acid, amine, and copper carboxylate functionalities were catalytically active for the Mannich, aldol, and Huisgen cycloaddition reactions, respectively. The functional groups in the 3D-printed structures were also amenable to post-printing chemical modification. And as proof of principle, chemically active cuvette adaptors were 3D printed and used to measure in situ the kinetics of a heterogeneously catalyzed Mannich reaction in a conventional solution spectrophotometer. In addition, 3D-printed millifluidic devices with catalytically active copper carboxylate complexes were used to promote azide-alkyne cycloaddition under flow conditions. The importance of controlling the 3D architecture of the millifluidic devices was evidenced by enhancing reaction conversion upon increasing the complexity of the 3D prints.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-stiffened continuous fiber structures

Under NASA's Novel Composites for Wing and Fuselage Applications (NCWFA) program, Contract NAS1-18784, Grumman is evaluating the structural efficiency of graphite/epoxy cross-stiffened panel elements fabricated using innovative textile preforms and cost effective Resin Transfer Molding (RTM) and Resin Film Infusion (RFI) processes. Two three-dimensional woven preform assembly concepts have been defined for application to a representative window belt design typically found in a commercial transport airframe. The 3D woven architecture for each of these concepts is different; one is vertically woven in the plane of the window belt geometry and the other is loom woven in a compressed state similar to an unfolded eggcrate. The feasibility of both designs has been demonstrated in the fabrication of small test element assemblies. These elements and the final window belt assemblies will be structurally tested, and results compared.

Ewen, John R.↗

A Brief Description of My Projects

My internship was in the IDC which consist of a machine shop and an array of design space. During my tour I worked on a wide variety of projects some of which included design, research, machining and fabrication. I gained further knowledge on some machines that I have had prior experience on such as the lathe and Hurco CNC machines. The first thing we did was complete our checkout in the machine shop which went pretty well, since I was already familiar with most of the machines. I also did a couple of practice parts on some of the machines, I made a name block on the CNC machine and I also used the vertical milling machine to complete this project. One of the other projects that I did was machine a hammer with my initials with the use of the lathe and CNC machine, this project took much longer since I had to set up a cylindrical piece on the CNC machine. The first project that I began work on was the Systems Engineering & Management Advancement Program (SEPMAP) Hexacopter project and helped them to assemble and modify one of their particle capture doors on their boxes. After a while we ended up helping them make a hinge and holes to reduce the weight of their design. We helped the NASA Extreme Environment Mission Operations (NEEMO) team a bit with some of their name tags and assembly of some of their underwater parts. One of the more challenging projects was a rail that came in with a rather weirdly drawn part. The biggest project that I worked on was the solar array project. Which consisted of a variety of machining and 3D printing and it took me about 3 different times of re-designing to come up with a final prototype. Along with this project I also had to complete a project in which I had to modify a thermos. This was rather simple since I just had to draw up a part and print it out on the 3D printer. I also learned how to use Pro E/Creo parametric to design a square block and print it on the 3D Printer. All of these projects increased my experience on all of the machines and equipment that I used. I also got to tweak my design skills and better understand how to modify my designs and how to improve those specific designs.

Barnes, Tobin↗