At least 955 records · Page 53

The influence of a Si cap on self-organized SiGe islands and the underlying wetting layer

For the prototypical SiGe/Si(001) Stranski-Krastanow (SK) growth system, the influence of intermixing caused by the deposition of a Si cap layer at temperatures T{sub cap} between 300 deg. C and 700 deg. C is studied both for the SiGe wetting layer (WL) and the SiGe islands. Systematic growth experiments were carried out with an ultrahigh resolution of down to 0.005 monolayers (ML) of deposited Ge. The properties of the samples were investigated via photoluminescence (PL) spectroscopy, atomic force microscopy (AFM), and transmission electron microscopy. We studied in detail the influence of T{sub cap} in the three main coverage regions of SiGe SK growth, which are (i) the WL build-up regime, (ii) the island nucleation regime, where most of the Ge is supplied via material transfer from the WL, and (iii) the saturation regime, where the WL thickness remains initially stable. At T{sub cap} = 300 deg. C, we found that both the WL and the island are essentially preserved in composition and shape, whereas at 500 deg. C the WL becomes heavily alloyed during capping, and at 700 deg. C the islands also become alloyed. At T{sub cap} = 500 deg. C we found enhanced WL intermixing in the presence of dome-shaped islands, whereas at T{sub cap} 700 deg. C the WL properties become dominated by the dissolution of pyramid-shaped islands upon capping. At Ge coverages above {approx_equal}6 ML, we found an unexpected thickening of the WL, almost independently of T{sub cap}. This finding suggests that the density and the volume of the dome-shaped islands have an upper limit, beyond which excess Ge from the external source again becomes incorporated into the WL. Finally, we compared PL spectra with AFM-based evaluations of the integral island volumes in order to determine in a straightforward manner the average composition of the SiGe islands.

36 MATERIALS SCIENCE↗

Surface Morphology and Dielectric Studies of Zr{sup 4+}-Rich Barium Titanate

In the current work, we have characterized a compound with general formula Ba(Zr{sub 0.52}Ti{sub 0.48})O{sub 3}(BZT). Surface morphology including grain distribution, histogram of area, volume, length and perimeter was examined through atomic force microscope (AFM). The AFM data revealed the non-uniform distribution of grains in the BZT ceramics. The temperature dependent relative permittivity of the sample was studied and found to exhibit diffuse phase transition phenomenon.

36 MATERIALS SCIENCE↗

Application of transmission electron microscopy for microstructural characterization of perfluoropentacene thin films

The crystalline structure and orientation of perfluoropentacene (C{sub 22}F{sub 14}, PFP) fibers formed upon thin-film deposition onto SiO{sub 2} substrates have been studied by means of transmission electron microscopy (TEM), atomic force microscopy (AFM), and x-ray diffraction. The synopsis of TEM micrographs and diffraction patterns enhances the understanding of local crystal orientation on small length scales. The relationship of the PFP fiber morphology with the crystalline arrangement of PFP molecules within single fibers was established using this technique. Radiation damage, which is a critical problem for TEM investigations of organic materials, is described and the sample morphology after TEM investigations is correlated with AFM measurements of samples previously examined by TEM.

36 MATERIALS SCIENCE↗

Rotational positioning system adapted to atomic force microscope for measuring anisotropic surface properties

The diverse atomic configurations induce the anisotropic surface properties. For investigating anisotropic phenomena, we developed a rotational positioning system adapted to atomic force microscope (AFM). This rotational positioning system is applied to revolve the measured sample to defined angular direction, and it composed of an inertial rotational stepper and a visual angular measurement. The inertial rotational stepper with diameter 30 mm and height 7.6 mm can be easily attached to the AFM-system built in any general optical microscope. Based on a clearance less bearing and the inertial driving method, its bidirectional angular resolution reaches 0.005 deg. per step. For realizing a close-loop controlled angular positioning function, the visual measurement method is utilized. Through the feedback control, the angular positioning error is less than 0.01 deg. For verifying the system performance, we used it to investigate the anisotropic surface properties of graphite. Through a modified cantilever tip, the atomic-scale stick-slip, and the anisotropic friction phenomena can be distinctly detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope

Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5% or less, but with precision limited to about 15%, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an {approx_equal} 4 % systematic error per {mu}N of applied load for loads {<=} 1 {mu}N. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nano structuring of GaAs(100) surface using low energy ion irradiation

Nanostructuring of semi insulating GaAs (100) has been observed after irradiation of 50 keV Ar{sup +} ion beam in a wide angular range of 0 deg. to 60 deg. with respect to surface normal. Atomic Force Microscopy (AFM) analysis shows the formation of nano dots at smaller angle of irradiation. At higher angle of irradiation, self organized ripples were developed on the surface. The rms roughness estimated from the AFM analysis shows exponential growth with angle of irradiation. In the high frequency regime, PSD analysis suggests that surface morphology of the irradiated samples is governed by the surface diffusion and mass transport dominated processes.

36 MATERIALS SCIENCE↗

Crystalline to amorphous phase transition of tin oxide nanocrystals induced by SHI at low temperature

Tin oxide (SnO{sub 2}) thin films were deposited using pulsed laser deposition (PLD) technique on Si substrates. The as-deposited films were irradiated using 100 MeV Ag ions at different fluences ranging from 3x10{sup 13} to 3x10{sup 14} ions/cm{sup 2} at an incidence angle of 75 deg. with respect to surface normal at liquid nitrogen (LN2) temperature. The as-deposited and irradiated films have been characterized using X-ray diffraction (XRD) and atomic force microscopy (AFM) techniques to study the modifications in structural and surface morphological properties. Nanocrystalline film become completely amorphous and nanograins of tin oxide disappeared from the surface as indicated by XRD spectra and AFM micrographs respectively.

36 MATERIALS SCIENCE↗

Dual growth modes in ion bombarded Si surfaces

Morphological studies were done on Si (001) surfaces after rastering them with a 1 keV O{sub 2}{sup +} ion beam at an angle. The resulting mounded morphology was studied using atomic force microscopy (AFM) measurements. The roughness at different length scales were further extracted and quantified from AFM measurements using scaling analysis. Results indicate two growth regimes of the evolving surface which were evident from the power spectral density (PSD) and interface width analysis of the eroded surfaces. Initially the growth is unstable followed by a stable regime of the nanostructures evolved after about 35 minutes of erosion. Temporal studies done on these surfaces show the onset of shadowing at higher sputtering times thus indicating the breakdown of the growth model at these times.

36 MATERIALS SCIENCE↗

A pressure gauge based on gas density measurement from analysis of the thermal noise of an atomic force microscope cantilever

We describe a gas-density gauge based on the analysis of the thermally-driven fluctuations of an atomic force microscope (AFM) cantilever. The fluctuations are modeled as a ring-down of a simple harmonic oscillator, which allows fitting of the resonance frequency and damping of the cantilever, which in turn yields the gas density. The pressure is obtained from the density using the known equation of state. In the range 10-220 kPa, the pressure readings from the cantilever gauge deviate by an average of only about 5% from pressure readings on a commercial gauge. The theoretical description we use to determine the pressure from the cantilever motion is based upon the continuum hypothesis, which sets a minimum pressure for our analysis. It is anticipated that the cantilever gauge could be extended to measure lower pressures given a molecular theoretical description. Alternatively, the gauge could be calibrated for use in the non-continuum range. Our measurement technique is similar to previous AFM cantilever measurements, but the analysis produces improved accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Traceable nanoscale measurement at NML-SIRIM

The role of national metrology institute (NMI) has always been very crucial in national technology development. One of the key activities of the NMI is to provide traceable measurement in all parameters under the International System of Units (SI). Dimensional measurement where size and shape are two important features investigated, is one of the important area covered by NMIs. To support the national technology development, particularly in manufacturing sectors and emerging technology such nanotechnology, the National Metrology Laboratory, SIRIM Berhad (NML-SIRIM), has embarked on a project to equip Malaysia with state-of-the-art nanoscale measurement facility with the aims of providing traceability of measurement at nanoscale. This paper will look into some of the results from current activities at NML-SIRIM related to measurement at nanoscale particularly on application of atomic force microscope (AFM) and laser based sensor in dimensional measurement. Step height standards of different sizes were measured using AFM and laser-based sensors. These probes are integrated into a long-range nanoscale measuring machine traceable to the international definition of the meter thus ensuring their traceability. Consistency of results obtained by these two methods will be discussed and presented. Factors affecting their measurements as well as their related uncertainty of measurements will also be presented.

47 OTHER INSTRUMENTATION↗

Exchange bias properties of [Co/CoO]{sub n} multilayers

In this study, the exchange bias properties of four polycrystalline multilayer stack samples of antiferromagnetic (AF) CoO and ferromagnetic (FM) Co in the form of [CoO/Co]{sub n} with n = 1, 2, 3, and 5 are reported. The samples were grown on top of Si (001) substrates by using magnetron sputtering method. X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) were used to determine the structural properties of the samples. XPS measurements of cobalt oxide layer revealed the coexistence of different phases in cobalt oxide as CoO and Co{sub 3}O{sub 4}, the latter of which lowers the blocking temperature. The blocking temperature is also affected by the finite size scaling effects observed in AF layers. In-plane ferromagnetic resonance (FMR) measurements revealed uniaxial in-plane magnetic anisotropy for the samples. Low temperature vibrating sample magnetometer measurements provided exchange bias with a stepwise character. Observed steps are believed to be due to magnetization reversals of individual FM layers with varying thicknesses, each of which is pinned through two interfaces from above and below with two AFM layers, except the uppermost FM Co layer with a single AFM neighbor.

36 MATERIALS SCIENCE↗

Processing optimization and sintering time dependent magnetic and optical behaviors of Aurivillius Bi{sub 5}Ti{sub 3}FeO{sub 15} ceramics

Aurivillius Bi{sub 5}Ti{sub 3}FeO{sub 15} (BTF) ceramics were synthesized using the conventional solid state reaction method by optimizing excess of Bi{sub 2}O{sub 3} and sintering time. Their structures, magnetic, and optical properties were investigated in detail. The optimum process to sinter pure Aurivillius BTF ceramics was confirmed to be 3 wt. % excess Bi{sub 2}O{sub 3} to compensate the Bi volatilization at 1050 Degree-Sign C for 240 min (BTF-240M). The microstructure and crystalline structure of the BTF ceramics had little dependence on the sintering time from the x-ray diffraction (XRD) and scanning electron microscopic data. Nevertheless, the magnetic and optical properties were closely related with the sintering time. The overall magnetic behavior of these BTF ceramics was superparamagnetic (SPM), whereas there were unambiguous clues for the existence of antiferromagnetic (AFM) interactions. However, whether the SPM behavior was intrinsic or arised from a tiny amount of spinel Fe{sub 3}O{sub 4} impurity phase cannot be thoroughly ruled out in the XRD detection limit in the present stage. The AFM interactions were weakened upon extending the sintering time. The effective magnetic moment ({mu}{sub eff}), however, demonstrated different dependency on the sintering time. It increased with the sintering time from 80 min to 240 min, and then dropped with further extending the sintering time. Compared with other BTF ceramics, the BTF-240M ceramic showed the highest values of the refractive index n and real part {epsilon}{sub 1}, as well as the lowest ones of the extinction coefficient k and imagine part {epsilon}{sub 2} in whole photon energy range. Finally, a direct inter-band transition was confirmed for these BTF ceramics and optical energy band gaps were determined to be about 3.08, 3.18, and 3.39 eV for 80 min, 150 min, and 240 min sintered BTF ceramics, respectively, yet abnormal optical behavior was observed in BTF-360M ceramic.

36 MATERIALS SCIENCE↗

Electrical and chemical characteristics of probe-induced two-dimensional SiO{sub x} protrusion layers

Three two-dimensional SiO{sub x} (x {identical_to} O/Si content ratio and x > 2) protrusion layers of {approx}0.5, {approx}4, and {approx}6 nm high were induced on a native SiO{sub 2} layer by atomic force microscopy (AFM) probes. X-ray photoemission spectroscopy (XPS) was used to reveal the elemental quantity of the photoelectrons, Si 2p core-levels, and Si oxidation states in the three SiO{sub x} protrusion layers and native SiO{sub 2} layer. Pt-coated conductive AFM probes were also exploited to acquire the rectifying current-voltage (IV) characteristics of the three SiO{sub x} protrusion layers and the native SiO{sub 2} layer, indicating all the three SiO{sub x} protrusion layers to be good Schottky diodes.

36 MATERIALS SCIENCE↗

Synthesis of nanocrystalline thin films of gold on the surface of GaSb by swift heavy ion

Thin films of gold ({approx}100 nm thick) were deposited on p-type GaSb substrates. These samples were irradiated with 100 MeV Fe{sup 7+}ions for the fluence of 1 Multiplication-Sign 10{sup 13} and 1 Multiplication-Sign 10{sup 14} ions cm{sup -2}. After irradiation, samples were characterized using AFM, UV-VIS -NIR, X-Ray Diffraction techniques. AFM studies showed the presence of clusters on the surface of GaSb. R.M.S. roughness of the sample was found to increase w.r.t ion fluence. Absorption coefficient obtained from the Ultra violet - Visible NIR (UV-VIS -NIR) spectra of the samples irradiated with various fluences compared with non irradiated GaSb. The annealing experiment showed a significant improvement in the absorption coefficient after rapid thermal annealing at temperature of 400 Degree-Sign C. X-Ray Diffraction study reveals different orientations of Au film.

36 MATERIALS SCIENCE↗

Formation of a ZnO{sub 2} layer on the surface of single crystal ZnO substrates with oxygen atoms by hydrogen peroxide treatment

Formation of a ZnO{sub 2} layer by H{sub 2}O{sub 2} treatment for single crystal ZnO (0001) substrates was studied. X-ray diffraction (XRD) peaks of ZnO{sub 2} with a pyrite structure were observed in XRD 2{theta}-{omega} scan patterns of the O-face of single crystal ZnO (0001) substrates with H{sub 2}O{sub 2} treatment, but these peaks were not observed in patterns of the Zn-face of ZnO (0001) substrates with H{sub 2}O{sub 2} treatment. XRD {omega} scan patterns of the ZnO (0002) plane of the O-face of single crystal ZnO (0001) substrates were broadened at the tail of the pattern by H{sub 2}O{sub 2} treatment, but such broadening was not observed in that plane of the Zn-face. Grain structure of ZnO{sub 2} layers was clearly observed in atomic force microscopy (AFM) images for the O-face of ZnO (0001) substrates with H{sub 2}O{sub 2} treatment. Spectra of X-ray photoelectron spectroscopy (XPS) of the O-face of ZnO (0001) substrates with H{sub 2}O{sub 2} treatment showed a definite peak shift of the O 1s peak. It is thought that a pyrite structure of ZnO{sub 2} is easily formed around an O atom of the O-face of ZnO (0001) substrates. Results of XRD measurements, the AFM image, and XPS measurement of the H{sub 2}O{sub 2}-treated single crystal ZnO (1010) substrate that has oxygen atoms on the surface appeared to be the same as those of the O-face of ZnO (0001) substrates.

36 MATERIALS SCIENCE↗

Formation of double ring patterns on Co{sub 2}MnSi Heusler alloy thin film by anodic oxidation under scanning probe microscope

Double ring formation on Co{sub 2}MnSi (CMS) films is observed at electrical breakdown voltage during local anodic oxidation (LAO) using atomic force microscope (AFM). Corona effect and segregation of cobalt in the vicinity of the rings is studied using magnetic force microscopy and energy dispersive spectroscopy. Double ring formation is attributed to the interaction of ablated material with the induced magnetic field during LAO. Steepness of forward bias transport characteristics from the unperturbed region of the CMS film suggest a non equilibrium spin contribution. Such mesoscopic textures in magnetic films by AFM tip can be potentially used for memory storage applications.

36 MATERIALS SCIENCE↗