Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

An upgraded G-band differential absorption radar system for future airborne studies

A proof-of-concept, 170 GHz frequency-modulated, continuous-wave (FMCW) radar has been developed for measuring water vapor profiles within the cloudy boundary layer from an airborne platform. The measurement concept exploits the differential absorption accrued by two or more transmitted frequencies in the vicinity of the 183 GHz water absorption line to retrieve range-resolved humidity profiles, so-called differential absorption radar (DAR). The upgraded system design includes important considerations for monostatic radar operation with an open fuselage viewport (i.e. no radome). The radar features an all-solid-state tansmitter with > 0:4 W continuous transmit power, a 60 cm primary aperture and corresponding 58 dB antenna gain, and more than 80 dB transmit/receive isolation, enabling near thermal-noise-limited sensitivity with a 8 dB noise figure receiver. Ice-cloud radar returns are detected beyond 8 km in height from the ground, demonstrating the high sensitivity of the system. In addition to in-cloud humidity profiling capabilities, deployment of a water vapor DAR from an airborne platform enables measurements of total column water vapor (TCWV) for all weather and surface scenarios. Precision estimates and potential biases for future TCWV measurements are discussed.

Monje, Raquel↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

A New Search for Low-mass Dark Matter and an Examination and Reduction of the Uncertainty due to the Photoelectric Absorption Cross Section using a Cryogenic Silicon Detector with Single-charge Sensitivity

Many astrophysical observations point to the abundant existence of dark matter (DM) in the universe composed of particles beyond the Standard Model. However despite numerous experiments using different techniques, DM particles have yet to be directly observed. The Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment will employ silicon and germanium crystal detectors operated at temperatures as low as 15~mK to probe DM interactions using phonon and ionization signals. Recently, R\&D; facilities have developed gram-sized high-voltage eV-scale (HVeV) silicon detectors that achieve single-electron-hole-pair resolution. By probing effective DM-electron interactions, these devices can be used for searches of low-mass DM candidates.This dissertation presents a DM search experiment known as HVeV Run~2 that employs a second-generation HVeV detector operated in an above-ground laboratory at Northwestern University (IL, USA). Energy spectra are obtained from a blind analysis with 0.39 and 1.2\,g-days of exposure with the detector biased at 60 and 100\,V, respectively. The 0.93~gram detector achieves a 3\,eV phonon energy resolution, corresponding to a world-leading charge resolution of 3\,\% of a single electron-hole pair for a detector bias of 100\,V. With charge carrier trapping and impact ionization effects incorporated into the DM signal models, the resulting exclusion limits are reported for inelastic DM-electron scattering for DM masses from 0.5--$10^{4}$\,MeV$/c^{2}$; in the mass range from 1.2--50\,eV$/c^{2}$ the limits for dark photon and axion-like particle absorption are reported.Several DM search experiments, including HVeV Run~2, are sensitive to low-mass DM candidates that rely on the temperature-dependent photoelectric absorption cross section of silicon. However discrepancies in the underlying literature data result in dominating systematic uncertainties on the DM exclusion limits. In order to reduce these systematic uncertainties, this dissertation presents a novel method of making a direct, low-temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap (1.2--2.8\,eV).

Wilson, Matthew James↗

ICRF wave propagation and absorption modelling via machine learning

A surrogate model of the wave absorption in the ion cyclotron range of frequencies is presented. The model is trained to capture the physics of 1D electron and ion power absorption profiles for both the high harmonic fast wave scheme in NSTX, and the minority heating scheme in WEST. The surrogate models, based on both the random forest regressor and the multilayer perceptron algorithms, reduce inference time of 1D power absorption profiles from 1-5 minutes required by TORIC to ∼50 µs with high accuracy (i.e. R2 = 0.71−0.96).

Sánchez-Villar↗

Laser absorptivity measurement device

A laser absorptivity measurement device uses a linearly polarized incident beam, an optical configuration comprising an internal polarizing beamsplitter that transmits the linearly polarized incident beam and a quarter-wave plate that converts linearly polarized incident beam into a circularly polarized incident beam that is reflected off a processing substrate. The quarter-wave plate and polarizing beamsplitter can then direct the reflected light back into an integrating volume, where the power of the reflected light can be measured by a photodetector. The laser absorptivity measurement device is capable of making real-time absorption efficiency measurements of a variety of laser-based processes, including laser welding and brazing, additive manufacturing, and laser marking.

Tung, Daniel↗

Comparison of liquid absorption-release of superabsorbent polymers in alkali-activated slag and Portland cement systems: An NMR study combined with additional methods

In this study, {sup 1}H low-field NMR was used to compare the liquid absorption-release behaviour of superabsorbent polymers (SAPs) in Portland cement (PC) paste, NaOH-activated slag (SH-AAS) paste, and water glass-activated slag (WG-AAS) paste. The liquid absorption of SAPs in the PC paste was lower than that in the SH-AAS paste and the WG-AAS paste. The liquid release was also faster, which was mainly due to the higher Ca{sup 2+} concentration in the pore fluid of the PC system. In the AAS system, although the Ca{sup 2+} concentration in the pore fluid was low, the Na{sup +} concentration was much higher than that in the PC system due to the activator. The Ca{sup 2+} in the PC system is an important factor affecting the swelling of SAPs, while in the AAS system, the swelling limitation of SAPs is the result of the combined effects of Ca{sup 2+} and Na{sup +}, with Na{sup +} being dominant.

36 MATERIALS SCIENCE↗

Carbon-supported Pt during aqueous phenol hydrogenation with and without applied electrical potential: X-ray absorption and theoretical studies of structure and adsorbates

Adsorbed hydrogen and phenol on Pt nanoparticles during (electro)catalytic hydrogenation are explored by combining x-ray absorption spectroscopy and ab initio simulations. Direct evidence for two types of Pt-C bonds at the surface of the metal particles detected by X-ray absorption spectroscopy suggest strong bonding between metal and the carbon support as well as adsorption of phenol nearly parallel to the surface. Hydrogen and phenol compete for accessible Pt sites. The surface concentrations are compatible with the proposal that atomic hydrogen and chemisorbed phenol are the species reacting in the rate-determining step of hydrogenation in the presence and absence of an external cathodic potential. During electrocatalytic hydrogenation the external electric potential controls the concentration of species on the surface, but doesnot impose structural or electronic property changes of the Pt compared to Pt particles in presence of hydrogen gas. Increasing reaction rates with increasing cathodic potential are attributed to the increase in chemical potential of adsorbed H.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficiency and mechanisms of Sb(III/V) removal by Fe-modified biochars using X-ray absorption spectroscopy

Fe-modified biochars (FeBC) are effective antimony (Sb) removal materials; however, the removal mechanisms require further investigation. In this study, aqueous Sb(III) and Sb(V) removal by FeBC (300, 600, and 900 °C) was evaluated, with the adsorption mechanisms investigated using X-ray absorption spectroscopy (XAS). Screening results (based on removal efficiencies) using different types of FeBC indicated the 900 °C FeCl3- modified biochar (FeCl3BC900) achieved the best Sb(III/V) removal performance. The kinetics of the Sb(III/V) removal process were best fitted by a pseudo-second-order model. Additionally, the isothermal results were described by Langmuir and Redlich-Peterson models. Aqueous analysis and X-ray absorption near-edge structure data fitting indicated Sb(III) was oxidized to Sb(V) in the Sb(III)-spiked system, and the oxidation extent increased with increasing pyrolysis temperature. The oxidation process rapidly occurred in both the solution and biochar. No Sb(V) was reduced to Sb(III) in the Sb(V)-spiked system. The XAS results of the isothermal experiment indicated the oxidation capacity of FeCl3BC900 was limited for high initial Sb(III) concentrations. The SbFe1 and Sb-Fe2 bonding distances were 3.05–3.10 and 3.47–3.54 Å, respectively, indicating inner-sphere complexes were formed during the Sb(III/V) removal processes. The Sb(III/V) removal mechanisms included electrostatic adsorption, inner-sphere complexes, and coprecipitation. Oxidation was also involved in Sb(III) removal.

Antimony↗

High-resolution spectroscopy of uranium laser-produced plasma using saturated absorption spectroscopy

High-resolution spectroscopy of laser ablation plumes or laser-produced plasmas (LPPs) is valuable for various applications, including measuring crowded spectral features, determining spectroscopic constants, characterizing plasmas, and performing isotopic analysis. However, various line broadening mechanisms in plasmas limit its use for several applications. Here, in this study, we present the use of saturated absorption spectroscopy (SAS) for Doppler-free linewidth analysis in a uranium LPP. We demonstrate that SAS is effective in obtaining Doppler-free Lamb dip profiles with linewidths on the order of ≤ 20 MHz. The effects of saturation on the Doppler-broadened absorption and Lamb dip profiles at different pressures and probe intensities are quantified, and their impact on measurements of plasma properties is discussed. Finally, we show that the linewidths of the Lamb dips can be used for quantitative estimates of pressure and natural broadening in the plasma.

Absorption spectroscopy↗

Absorption Correction for Reliable Pair Distribution Functions from Low Energy X-ray Sources

This paper explores the development and testing of a simple absorption correction model for processing powder X-ray diffraction data from Debye−Scherrer geometry laboratory X-ray experiments. This may be used as a preprocessing step before using PDFGETX3 to obtain reliable pair distribution functions (PDFs). Various experimental and theoretical methods for estimating μR were explored, and the most appropriate μR values for correction were identified for different capillary diameters and X-ray beam sizes. We identify operational ranges of μR where a reasonable signal-to-noise ratio is possible after correction. A user-friendly software package, DIFFPY.LABPDFPROC, is presented that can help estimate μR and perform absorption corrections with a rapid calculation for efficient processing.

Absorption↗

Modeling the Conformer-Dependent Electronic Absorption Spectra and Photolysis Rates of Methyl Vinyl Ketone Oxide and Methacrolein Oxide

Criegee intermediates are important atmospheric oxidants, formed via the reaction of ozone with volatile alkenes emitted into the troposphere. Small Criegee intermediates (e.g., CH 2 OO and CH 3 CHOO) are highly reactive, and their removal via unimolecular decay or bimolecular chemistry dominates their atmospheric lifetimes. As the molecular complexity of Criegee intermediates increases, their electronic absorption spectra show a bathochromic shift within the solar spectrum relevant to the troposphere. In such cases, solar photolysis may become a competitive contributor to their atmospheric removal. In this article, we report the conformer-dependent simulated electronic absorption spectra of two four-carbon-centered Criegee intermediates, methyl vinyl ketone oxide (MVK-oxide) and methacrolein oxide (MACR-oxide). Both MVK-oxide and MACR-oxide contain four low-energy conformers, which are convoluted in the experimentally measured spectra. Here, we deconvolute each conformer and estimate contributions from each of the four conformers to the experimentally measured spectra. We also estimate the photolysis rates and predict that solar photolysis should be a more competitive removal process for MVK-oxide and MACR-oxide (cf. CH 2 OO and CH 3 CHOO).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carrier and Phonon Dynamics in Multilayer WSe 2 Captured by Extreme Ultraviolet Transient Absorption Spectroscopy

Carrier and phonon dynamics in a multilayer WSe2 film are captured by extreme ultraviolet (XUV) transient absorption (TA) spectroscopy at the W N 6,7 , W O 2,3 , and Se M 4,5 edges (30–60 eV). After the broadband optical pump pulse, the XUV probe directly reports on occupations of optically excited holes and phonon-induced band renormalizations. Here, when compared with density functional theory calculations, XUV transient absorption due to holes is identified below the W O 3 edge whereas signals at the Se M 4,5 edges are dominated by phonon dynamics. Therein, 0.4 ps hole relaxation time, 1.5 ps carrier recombination time, and 1.7 ps phonon heating time are extracted. The acquisition of hole and phonon-induced signals in a single experiment can facilitate the investigation of the correlations between electron and phonon dynamics. Furthermore, the simultaneous observation of signals from different elements can be further extended to explore photochemical processes in multilayers and alloys, thereby providing key information for their applications in electronics, photocatalysts, and spintronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rates of Ammonia Absorption and Release in Calcium Chloride

After synthesis, ammonia can be selectively absorbed by calcium chloride; nitrogen and hydrogen are not absorbed. The kinetics of release seem to be diffusion controlled. The kinetics of absorption are consistent with a first-order reaction after an initial period of a higher-order reaction, which may indicate a nucleation event. At 225 °C, both absorption and release show half-lives of around 10 min if the ammonia partial pressure is swung from 2 to 1 bar, which allows design of an absorber for the periodic separation of ammonia. Furthermore, when this absorber replaces the ammonia condenser in a conventional ammonia synthesis, the ammonia production at low pressure can have the same rate as the conventional process operating at higher pressure.

09 BIOMASS FUELS↗

Computing x-ray absorption spectra from linear-response particles atop optimized holes

State specific orbital optimized density functional theory (OO-DFT) methods, such as restricted open-shell Kohn–Sham (ROKS), can attain semiquantitative accuracy for predicting x-ray absorption spectra of closed-shell molecules. OO-DFT methods, however, require that each state be individually optimized. In this Communication, we present an approach to generate an approximate core-excited state density for use with the ROKS energy ansatz, which is capable of giving reasonable accuracy without requiring state-specific optimization. Herein, this is achieved by fully optimizing the core-hole through the core-ionized state, followed by the use of electron-addition configuration interaction singles to obtain the particle level. This hybrid approach can be viewed as a DFT generalization of the static-exchange (STEX) method and can attain ~0.6 eV rms error for the K-edges of C–F through the use of local functionals, such as PBE and OLYP. This ROKS(STEX) approach can also be used to identify important transitions for full OO ROKS treatment and can thus help reduce the computational cost of obtaining OO-DFT quality spectra. ROKS(STEX), therefore, appears to be a useful technique for the efficient prediction of x-ray absorption spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray absorption spectroscopy and theoretical investigations of the effect of extended ligands in potassium organic matter interaction

Potassium (K) is an essential nutrient for plant growth, and despite its abundance in soil, most of the K is structurally bound in minerals, limiting its bioavailability and making this soil K reservoir largely inaccessible to plants. Microbial biochemical weathering has been shown to be a promising pathway to sustainably increase plant available K. However, the mechanisms underpinning microbial K uptake, transformation, storage, and sharing are poorly resolved. Here, to better understand the controls on microbial K transformations, we performed K K-edge x-ray absorption near-edge structure (XANES) spectroscopy on K-organic salts, including acetate, citrate, nitrate, oxalate, and tartrate, which are frequently observed as low molecular weight organic acids secreted by soil microbes, as well as humic acid, which acts as a proxy for higher molecular weight organic acids. The organic salts display feature-rich K XANES spectra, each demonstrating numerous unique features spanning ~13 eV range across the absorption edge. In contrast, the spectra for humic acid have one broad, wide feature across the same energy range. We used a combination of time-dependent density functional theory and the Bethe–Salpeter equation based approach within the OCEAN code to simulate the experimental spectra for K-nitrate (KNO 3 ) and K-citrate [K 3 (C 6 H 5 O 7 )·H 2 O] to identify the electronic transitions that give rise to some of the outlying and unique spectral features in the organic salts. KNO 3 has both the lowest and highest lying energy features, and K 3 (C 6 H 5 O 7 )·H 2 O is produced by several soil microbes and is effective at mineral weathering. Our results analyze the K-organic salt bonding in detail to elucidate why the spectral shapes differ and indicate that the K K-edge XANES spectra are associated with the entire ligand despite similar first-shell bonding environments around the K center. The improved understanding of K bonding environments with organic ligands and their use for interpretation of the K-XANES spectra provides an important toolkit to understand how K is transformed by microbial processes and made bioavailable for plant uptake.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Site-specific electronic structure of covalently linked bimetallic dyads from nitrogen K-edge x-ray absorption spectroscopy

A nitrogen K-edge x-ray absorption near-edge structure (XANES) survey is presented for tetrapyrido[3,2-a:',3'-c:3'',2''-h:2''',3'''-j]phenazine (tpphz)-bridged bimetallic assemblies that couple chromophore and catalyst transition metal complexes for light driven catalysis, as well as their individual molecular constituents. We demonstrate the high N site sensitivity of the N pre-edge XANES features, which are energetically well-separated for the phenazine bridge N atoms and for the individual metal-bound N atoms of the inner coordination sphere ligands. By comparison with the time-dependent density functional theory calculated spectra, we determine the origins of these distinguishable spectral features. We find that metal coordination generates large shifts toward higher energy for the metal-bound N atoms, with increasing shift for 3d < 4d < 5d metal bonding. This is attributed to increasing ligand-to-metal σ donation that increases the effective charge of the bound N atoms and stabilizes the N 1s core electrons. In contrast, the phenazine bridge N pre-edge peak is found at a lower energy due to stabilization of the low energy electron accepting orbital localized on the phenazine motif. While no sensitivity to ground state electronic coupling between the individual molecular subunits was observed, the spectra are sensitive to structural distortions of the tpphz bridge. Here these results demonstrate N K-edge XANES as a local probe of electronic structure in large bridging ligand motifs, able to distinctly investigate the ligand-centered orbitals involved in metal-to-ligand and ligand-to-ligand electron transfer following light absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature estimation in a spatially inhomogeneous flame by diode laser absorption spectroscopy

A two-temperature (2T) model is proposed for estimating the temperature of a spatially inhomogeneous hot zone using single-beam diode laser absorption spectrometry. The proposed algorithm is based on fitting experimental absorption spectra by a linear combination of two database-simulated single-temperature spectra with different temperatures. The model efficiency is experimentally demonstrated when determining the temperature in different flame zones of a Wolfgard – Parker slot burner. The proposed 2T algorithm is used to find the maximum and minimum temperatures in different flame sections, which are compared with local temperatures in the same flame zones measured by the method of coherent anti-Stokes Raman scattering (CARS). It is shown that the maximum temperatures determined by the proposed 2T algorithm are in good agreement with CARS data in flame zones where high-temperature regions prevail. A good agreement between the minimum temperatures obtained by these two methods is also observed for predominantly cold zones. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗