Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Exploring the Accuracy of RANS Simulations for Mars Entry Vehicles

Accurate yet inexpensive predictions of aerodynamic coefficients for Mars entry vehicles have remained a consistent challenge over the past five decades. Below Mach 6, drag on the backshell becomes significant and must be accurately predicted. Steady Reynolds-averaged Navier-Stokes (RANS) models are commonly used, despite their poor predictions of backshell pressure. While scale-resolving simulations have shown promise in the past decade, there is still a need for cheap, accurate RANS predictions for large aerodynamic databases. The Mars Science Laboratory (MSL) is used as a case study to examine predictive accuracy and known shortcomings for RANS predictions of Mars entry vehicles. Several different grid generation techniques are compared, including a comparison between prismatic boundary layer grids and fully unstructured, tetrahedral grids. Comparisons are made to experimental data for Mach 2.5, 3.5, and 4.5. The accuracy of predicted aerodynamic coefficients is examined. Overpredictions in axial force and drag are explained by a closer examination of the surface pressure. These findings document sensitivities and best practices for future RANS database development of Mars entry vehicles.

RANS↗

Exploring the Accuracy of RANS Simulations for Mars Entry Vehicles

Accurate yet inexpensive predictions of aerodynamic coefficients for Mars entry vehicles have remained a consistent challenge over the past five decades. Below Mach 6, drag on the backshell becomes significant and must be accurately predicted. Steady Reynolds-averaged Navier-Stokes (RANS) models are commonly used, despite their poor predictions of backshell pressure. While scale-resolving simulations have shown promise in the past decade, there is still a need for cheap, accurate RANS predictions for large aerodynamic databases. The Mars Science Laboratory (MSL) is used as a case study to examine predictive accuracy and known shortcomings for RANS predictions of Mars entry vehicles. Several different grid generation techniques are compared, including a comparison between prismatic boundary layer grids and fully unstructured, tetrahedral grids. Comparisons are made to experimental data for Mach 2.5, 3.5, and 4.5. The accuracy of predicted aerodynamic coefficients is examined. Overpredictions in axial force and drag are explained by a closer examination of the surface pressure. These findings document sensitivities and best practices for future RANS database development of Mars entry vehicles.

CFD↗

Assessment of M2020 Terrain Relative Landing Accuracy: Flight Performance vs Predicts

Terrain Relative Navigation (TRN) was a critical enabling Entry, Descent, and Landing (EDL) technology that enabled Mars 2020 mission Perseverance rover to land at Jezero crater. TRN pro-vides real-time, autonomous, map-relative position determination and generates a landing target based on a priori knowledge of hazards. The required performance for TRN was to land within 60m of the selected target. The required 60m was sub-allocated to various error sources in three major categories: targeting error, knowledge error, and control error. The targeting error is the error in selecting an appropriate landing target and the knowledge of the target on the surface. It includes the Lander Vision System (LVS) position localization with respect the ground, the synchronization between the Lander Vision System measurement and the main Navigation filter, and errors associated with the LVS Reference Map and Safe Target Selec-tion (STS). The knowledge error is the contribution of knowledge growth from the synchronization with LVS to touchdown. The control error encompasses how accurately the system could stay on the desired reference trajectory. The TRN error budget uses a combination of analysis, simulation, and hardware test-ing results to bound the various error contributions obtained during the verification and validation process. This paper first presents a description the TRN system, focusing on the architecture of LVS and STS. The paper then gives detailed overview of the TRN error budget, with a description of the major error contribu-tions in each of the three categories. Next, the paper gives the results for three versions of the error budget, pre-launch, in-flight pre-landing, and post-landing. The paper compares the pre-flight analysis, the pre-landing analysis using in-flight data during cruise, to the post-landing analysis of the TRN performance. Pre-landing analysis best estimate of the landing performance was 33m, compared to the 60m require-ment. Post-landing analysis estimated a landing accuracy of 8.53m or better, much better than the 33m pre-landing estimate. The actual post-landing imagery calculated the distance of the rover to the targeted location to be 5m. The post-landing analysis closely bounds the image-based assessment of landing accu-racy, indicating the success of the error budget architecture in bounding the landing accuracy, as well as the fidelity of the simulations used to model and predict performance.

Chen, Allen↗

Analysis of the Tropospheric Doppler Radar Wind Profiler Measurement Accuracy

Space launch vehicle trajectory design uses atmospheric winds to determine vehicle performance and structural margin assessments prior to flight. For launches at the United States Space Force’s Eastern Range (ER) at the Cape Canaveral Space Force Station (CCSFS), tropospheric wind measurements come from either in-situ or remote sensing instrumentation. The use of the National Aeronautics and Space Administration’s (NASA) Kennedy Space Center (KSC) 48-MHz Tropospheric Doppler Radar Wind Profiler (TDRWP) has become the primary wind measurement source for several launch vehicles. Extensive evaluations of TDRWP data have occurred to quantify the system performance. This includes quantifying the accuracy of wind estimates over the entire sampling altitude as well as at discrete altitudes. This paper will describe methodology and analyses used to quantify the measurement accuracy of TDRWP data when operating in an alternative mission support mode over a 2-year period from March 2020 to March 2022.

Meghan E Carrico↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low-load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the bridge sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

Enhancements to Overset Methods for Achieving Higher Accuracy and Solution Convergence: Preprint

Overset methods, when utilized within a multi-solver framework, provide a very flexible and powerful toolset for analyzing moving body problem. However, many overset framework suffer from several deficiencies such as (1) convergence degradation of the non-linear iterative schemes (2) difficulty in achieving higher-order accuracy and (3) high computational costs over long simulation times. In this work, we explore approaches that mitigate these deficiencies and provide a pathway for improved accuracy and fidelity of overset methods. A high-order, discontinuous Galerkin solver is integrated into an existing overset framework and applied to an unsteady ROBIN fuselage case. For convergence acceleration, an Overset-GMRES linear solver with a timestep controller is applied to a DLR-F6 aircraft steady simulation and an unsteady, notional rotor-fuselage. Finally the same rotor-fuselage case as well as the JVX rotor/wing case is simulated using a reduced-order aerodynamic model.

aerospace↗

Methods in Use for Sensitivity Analysis, Uncertainty Evaluation, and Target Accuracy Assessment

Sensitivity coefficients can be used for different objectives like uncertainty estimates, design optimization, determination of target accuracy requirements, adjustment of input parameters, and evaluations of the representativity of an experiment with respect to a reference design configuration. In this paper the theory, based on the adjoint approach, that is implemented in the ERANOS fast reactor code system is presented along with some unique tools and features related to specific types of problems as is the case for nuclide transmutation, reactivity loss during the cycle, decay heat, neutron source associated to fuel fabrication, and experiment representativity.

99 GENERAL AND MISCELLANEOUS↗

A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Centerline of Flow Measurement for Sizing of the Zenith AAA Endovascular Graft and Predictive Factor for Risk of Inadequate Sizing

The purpose of this study was to evaluate the accuracy of centerline of flow (CLF) measurement for precise sizing of the Zenith AAA endovascular graft (Zenith) and to identify predictive factors of risk of inadequate endograft sizing. We analyzed 42 consecutive patients treated using the Zenith with pre- and postoperative multidetector CT between 2001 and 2007. Endograft sizing was retrospectively performed using CLF on a three-dimensional workstation. The following parameters were investigated: (a) change in distance from lowest renal artery to hypogastric artery between CLF on preoperative CT (CLFp) and CLF of graft path on postoperative CT (CLFg); (b) supposed success rate of adequate endograft length selection; and (c) predictive factors for significant alteration (>10 mm) between CLFp and CLFg. Median change in distance from lowest renal artery to hypogastric artery was 4 mm. CLFg was >10 mm shorter than CLFp in 10 of 84 limbs (12%). Multivariate analysis demonstrated tortuosity index (TI) of infrarenal abdominal aorta (p = 0.019), aneurysm diameter (p = 0.035), and ipsilateral side of the main body insertion (p = 0.042) as predictive factors of significant alteration between CLFp and CLFg. Adequate endograft length selection was achieved in 39 of 42 cases (93%). All three inadequate endograft length selections were associated with tortuous aorta (TI > 20 mm). In conclusion, distance calculations based on CLF measurement provided accurate length selection of the Zenith in the majority of cases. TI, aneurysm diameter, and ipsilateral side were predictive factors for significant alteration. The CLF and aortic measurements including the TI may allow for improved sizing for Zenith placements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Spatial Accuracy of a Fusion Imaging Technique Combining Previously Acquired Computed Tomography and Real-Time Ultrasound for Imaging of Liver Metastases

Purpose: This study was designed to evaluate the spatial accuracy of matching volumetric computed tomography (CT) data of hepatic metastases with real-time ultrasound (US) using a fusion imaging system (VNav) according to different clinical settings. Methods: Twenty-four patients with one hepatic tumor identified on enhanced CT and US were prospectively enrolled. A set of three landmarks markers was chosen on CT and US for image registration. US and CT images were then superimposed using the fusion imaging display mode. The difference in spatial location between the tumor visible on the CT and the US on the overlay images (reviewer no. 1, comment no. 2) was measured in the lateral, anterior-posterior, and vertical axis. The maximum difference (Dmax) was evaluated for different predictive factors.CT performed 1-30 days before registration versus immediately before. Use of general anesthesia for CT and US versus no anesthesia.Anatomic landmarks versus landmarks that include at least one nonanatomic structure, such as a cyst or a calcificationResultsOverall, Dmax was 11.53 {+-} 8.38 mm. Dmax was 6.55 {+-} 7.31 mm with CT performed immediately before VNav versus 17.4 {+-} 5.18 with CT performed 1-30 days before (p < 0.0001). Dmax was 7.05 {+-} 6.95 under general anesthesia and 16.81 {+-} 6.77 without anesthesia (p < 0.0015). Landmarks including at least one nonanatomic structure increase Dmax of 5.2 mm (p < 0.0001). The lowest Dmax (1.9 {+-} 1.4 mm) was obtained when CT and VNav were performed under general anesthesia, one immediately after the other. Conclusions: VNav is accurate when adequate clinical setup is carefully selected. Only under these conditions (reviewer no. 2), liver tumors not identified on US can be accurately targeted for biopsy or radiofrequency ablation using fusion imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of Distance Determination by Range–Intensity Correlation Methods for Nonrectangular Illuminating Pulse Shape

We have analyzed the accuracy of distance determination by range–intensity correlation methods in the case of an arbitrary pulse shape. We show that the absolute error is proportional to the pulse duration τ{sub L}. For a trapezoidal pulse shape, which is a reasonable approximation of the real pulse shape, we obtain an analytical estimate of the extremal error and the distance at which is it realized. The maximum error in the distance obtained in calculations with trapezoidal pulses corresponds to an extremely asymmetric pulse and is a little over 10% of the spatial pulse length τ{sub L}c, where c is the speed of light. Symmetric pulses give an error due to nonrectangularity of the pulse that is smaller by a factor of ~2. Since a trapezoidal shape can qualitatively reproduce the shape of practically any real pulse, probably the trapezoidal pulse model gives an estimate of the highest possible error.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new method for increasing accuracy of distance measurement based on single visual camera

Camera has been widely used in computer vision and mobile robotics applications because the sensor provides complementary information. However, the chief drawback of camera is that it only can provide 2D image information without depth information. There are lots of people studying the distance measurement with single visual camera, however it is difficult to achieve high precision. Usually we use two cameras to form stereo image and measure distance. Obviously it is complex. In this paper, we study the reason why distance measurement with single camera can hardly achieve high precision and propose a new method for improving the accuracy. We evaluate the proposed method and compare with existing methods to demonstrate the efficiency and high precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-accuracy multi-configuration Dirac–Hartree–Fock calculations of the energy levels and transition properties of Ga-like to Br-like gadolinium ions

Highlights: • A complete and accurate data set of excitation energies, lifetimes, wavelengths and E1, M1, E2, M2 and E3 line strengths, transition rates, and oscillator strengths for Ga-like to Br-like Gd ions is reported. • The Multi-configuration Dirac–Hartree–Fock method is employed. • The effects of core–valence electron correlation from the deep subshells 3d and 3p have been investigated. • The computed excitation energies from the present MCDHF calculations of the VV+CV{sub 3d}+CV{sub 3p} model agree well with the experimental values. The differences are less than ±0.1% for most of the levels. - Abstract: Theoretical calculations of Ga-like to Br-like gadolinium ions were performed by using the fully relativistic multi-configuration Dirac–Hartree–Fock (MCDHF) method. Extensive lists of excitation energies, wavelengths, line and oscillator strengths, and E1, M1, E2, M2, and E3 transition rates are presented. The effects of core–valence electron correlation from the deep subshells 3d and 3p are investigated and the accuracy of the results is confirmed by comparing with available theoretical and experimental data sets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

Purpose: To quantify the clinical accuracy of the respiratory motion tracking system of the CyberKnife treatment device. Methods and Materials: Data in log files of 44 lung cancer patients treated with tumor tracking were analyzed. Errors in the correlation model, which relates the internal target motion with the external breathing motion, were quantified. The correlation model error was compared with the geometric error obtained when no respiratory tracking was used. Errors in the prediction method were calculated by subtracting the predicted position from the actual measured position after 192.5 ms (the time lag to prediction in our current system). The prediction error was also measured for a time lag of 115 ms and a new prediction method. Results: The mean correlation model errors were less than 0.3 mm. Standard deviations describing intrafraction variations around the whole-fraction mean error were 0.2 to 1.9 mm for cranio-caudal, 0.1 to 1.9 mm for left-right, and 0.2 to 2.5 mm for anterior-posterior directions. Without the use of respiratory tracking, these variations would have been 0.2 to 8.1 mm, 0.2 to 5.5 mm, and 0.2 to 4.4 mm. The overall mean prediction error was small (0.0 {+-} 0.0 mm) for all directions. The intrafraction standard deviation ranged from 0.0 to 2.9 mm for a time delay of 192.5 ms but was halved by using the new prediction method. Conclusions: Analyses of the log files of real clinical cases have shown that the geometric error caused by respiratory motion is substantially reduced by the application of respiratory motion tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of Photon Beams of a Flattening Filter-Free Linear Accelerator and the Accuracy of Beam Modeling Using an Anisotropic Analytical Algorithm;TrueBeam; Flattening filter free; Commissioning; Anisotropic analytical algorithm

Purpose: To investigate dosimetric characteristics of a new linear accelerator designed to deliver flattened, as well as flattening filter-free (FFF), beams. To evaluate the accuracy of beam modeling under physical conditions using an anisotropic analytical algorithm. Methods and Materials: Dosimetric data including depth dose curves, profiles, surface dose, penumbra, out-of-field dose, output, total and scatter factors were examined for four beams (X6, X6FFF, X10, and X10FFF) of Varian's TrueBeam machine. Beams modeled by anisotropic analytical algorithm were compared with measured dataset. Results: FFF beams have lower mean energy (tissue-phantom ratio at the depths of 20 and 10 cm (TPR 20/10): X6, 0.667; X6FFF, 0.631; X10, 0.738; X10FFF, 0.692); maximum dose is located closer to the surface; and surface dose increases by 10%. FFF profiles have sharper but faster diverging penumbra. For small fields and shallow depths, dose outside a field is lower for FFF beams; however, the advantage fades with increasing phantom scatter. Output increases 2.26 times for X6FFF and 4.03 times for X10FFF and is less variable with field size; collimator exchange effect is reduced. A good agreement between modeled and measured data is observed. Criteria of 2% depth-dose and 2-mm distance-to-agreement are always met. Conclusion: Reference dosimetric characteristics of TrueBeam photon bundles were obtained, and successful modeling of the beams was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-based Preplanning Using CT and MRI Data Fusion in Patients With Cervical Cancer Treated With 3D-based Brachytherapy: Feasibility and Accuracy Study

Purpose: Magnetic resonance imaging (MRI)-assisted radiation treatment planning enables enhanced target contouring. The purpose of this study is to analyze the feasibility and accuracy of computed tomography (CT) and MRI data fusion for MRI-based treatment planning in an institution where an MRI scanner is not available in the radiotherapy department. Methods and Materials: The registration inaccuracy of applicators and soft tissue was assessed in 42 applications with CT/MRI data fusion. The absolute positional difference of the center of the applicators was measured in four different planes from the top of the tandem to the cervix. Any inaccuracy of registration of soft tissue in relation to the position of applicators was determined and dose-volume parameters for MRI preplans and for CT/MRI fusion plans with or without target and organs at risk (OAR) adaptation were evaluated. Results: We performed 6,132 measurements in 42 CT/MRI image fusions. Median absolute difference of the center of tandem on CT and MRI was 1.1 mm. Median distance between the center of the right ovoid on CT and MRI was 1.7 and 1.9 mm in the laterolateral and anteroposterior direction, respectively. Corresponding values for the left ovoid were 1.6 and 1.8 mm. Rotation of applicators was 3.1 Degree-Sign . Median absolute difference in position of applicators in relation to soft tissue was 1.93, 1.50, 1.05, and 0.84 mm in the respective transverse planes, and 1.17, 1.28, 1.27, and 1.17 mm in selected angular directions. The dosimetric parameters for organs at risk on CT/MRI fusion plans without OAR adaptation were significantly impaired whereas the target coverage was not influenced. Planning without target adaptation led to overdosing of the target volume, especially high-risk clinical target volume - D{sub 90} 88.2 vs. 83.1 (p < 0.05). Conclusions: MRI-based preplanning with consecutive CT/MRI data fusion can be safe and feasible, with an acceptable inaccuracy of soft tissue registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

62 RADIOLOGY AND NUCLEAR MEDICINE↗