Search NASA⌕ Search

SEARCH · Search NASA

Results for “CABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

CMOS-compatible tristate cable driver

Device provides noise immunity, draws zero standby power, and improves performance where same bus connects several pieces of CMOS equipment.

Pryor, R. L.↗

Testing flat-conductor cable

Report describes characteristics of type of FCC which consists of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with self-extinguishing polyester adhesive.

Loggins, R. W.↗

Surface mounted flat-conductor cable

Report presents drawbacks and advantages of FCC for home wiring. Two types of surface-wiring schemes are considered: snap-on baseboard and extendable baseboard. Both types lower installation cost and time.

Hankins, J. D.↗

Flat-conductor cable baseboard

Report presents procedures and results of test of FCC baseboard system developed for use in commerical and residential applications. Mechanical, electrical, chemical, environmental, thermal, and analytical tests subjected system to conditions of greater severity than would be encountered in normal service; system withstood tests favorably.

Hankins, J. D.↗

Connector with cable-to-chassis strain relief

Electronic connector adapted from readily available components simplifies electronic packaging and interconnection wiring in assemblies that consist of several identical printed-wiring boards.

Tuskind, K. W.↗

Simpler cabling and power link for remote readouts

Display power and segment data are multiplexed over same coaxial line. Thus, only one wire and return lead are needed, and single power supply at central location can service all remote displays.

Perry, J. C.↗

Some heat transfer and hydrodynamic problems associated with superconducting cables (SPTL)

To study some effects of thermogravitation on (CIIK-SPTL) systems, a heated tube experiment was set up at Krzhizhanovsky Power Engineering Institute Moscow, U.S.S.R. Heat transfer data were taken with fluid helium flowing through a 2.85 m, 19 mm diameter uniformly heated horizontal tube. Temperatures were measured on the top and bottom of the tube at six axial locations with three other circumferential measurements made at (X/L) =57. Typical temperature profiles show significant variations both axially and circumferentially. The data are grouped using reduced Nusselt number (NuR) and the bulk expansion parameter for each axial location. The average data for 0.26 less than or equal to X/L less than or equal to 0.76 follow a power law relation with the average expansion parameter. System instabilities are noted and discussed. Future work including heat transfer in coaxial cylinders is discussed.

Hendricks, R. C.↗

Stripping the Sheath From Stranded Cables

Device similar to tubing cutter removes tough plastic cover. Insulation stripper is 3 in. (7.6 cm) long and 1.5 (3.8 cm) in diameter. Two rollers are small-diameter bearings. Cutter blade journaled for rotation between pair of similar bearings. Bearings either pin or ball types of suitable dimensions.

Prisk, A. L.↗

Tension waves in tethered satellite cables

A one-degree-of-freedom simulation of the Tethered Satellite System (TSS) was programmed using a distributed system model of the tether based on the one-dimensional wave equation. This model represents the time varying tension profile along the tether as the sum of two traveling waves of tension moving in opposite directions. A control loop was devised which combines a deployment rate command with the measured tension at the deployer to produce a smooth, stable rate of deployment of the subsatellite. Simulation results show a buildup of periodic bursts of high frequency oscillation in tension. This report covers the mathematical modelling and simulation results and explains the reason for the observed oscillations. The design of a possible vibration damping device is discussed.

Lallman, F. J.↗

PCACE-Personal-Computer-Aided Cabling Engineering

PCACE computer program developed to provide inexpensive, interactive system for learning and using engineering approach to interconnection systems. Basically database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. Directly emulates typical manual engineering methods of handling data, thus making interface between user and program very natural. Apple version written in P-Code Pascal and IBM PC version of PCACE written in TURBO Pascal 3.0

Billitti, Joseph W.↗

Radiation and temperature effects on LDEF fiber optic cable samples

This paper will concentrate on results obtained from the Jet Propulsion Lab (JPL) Fiber Optics Long Duration Exposure Facility (LDEF) Experiment since the June 1991 Experimenters Workshop. Radiation darkening of the laboratory control samples will be compared with the LDEF flight samples. The results of laboratory temperature tests on the flight samples extending over a period of about nine years including the preflight and postflight analysis periods will be described.

Johnston, Alan R.↗

A cable detection lidar system for helicopters

Helicopters in low-level flight are endangered by power lines or telephone wires, especially when flying at night and under poor visibility conditions. In order to prevent 'wire strike', Thomson has developed a lidar system consisting of a pulsed diode laser emitting in the near infrared region (lambda = 0.9 microns). The HOWARD (Helicopter Obstacle Warning and Detection) System utilizes a high repetition rate diode laser (PRE = 20 KHz) along with counter-rotating prisms for laser beam deflection with a total field of view of 30 degrees. This system was successfully field tested in 1991. HOWARD can detect one inch wires at ranges up to 200 meters. We are presently in the process of developing a flyable compact lidar system capable of detection ranges in the order of 400 meters.

Grossmann, Benoist↗

Fiber Optic Cable Feedthrough and Sealing

A novel fiberoptic hermetic bulkhead feedthrough has been developed which will offer cryogenic sealing at leak rates of 10(exp -11) cc/sec helium. This feedthrough was developed for NASA in response to needs for a hermetically sealed feedthrough which could withstand a range of temperatures from low cryogenic (-196 C), due to liquid fuels and oxidizers, to high temperatures (+200 C) encountered in the proximity of combustion gasses. The development effort will be reported from conceptual design of single and multi-channel feedthrough units with single interconnection interfaces to units with double-ended interconnection interfaces. Various combinations of fiber/buffers are reported with recommendations based on test results. A comprehensive series of environmental and mechanical tests were performed to evaluate the feedthroughs in adverse conditions. Test results are reported including insertion loss, salt spray, sinusoidal vibration, random vibration, mechanical shock, thermal shock and humidity. A second set of feedthrough units was exposed to 3 different types of radiation. Optical transmittance changes during the tests were monitored and leak rate testing was done after each test. State-of-the-art technology in optical fiber feedthroughs constructed with polycrystalline ceramic is presented.

Fan, Robert J.↗