Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

CCD imaging of Neptune at methane-band wavelengths

Ground-based CCD imaging of Neptune in the near-IR clearly shows discrete cloud features. The brightest cloud features on Neptune are confined to latitudes from about 30 to 50 deg (in both hemispheres). Fainter enhanced regions are sometimes seen at even higher latitudes. Imaging obtained prior to 1986 showed bright clouds in both northern and southern midlatitudes, giving Neptune the appearance of having a dark equatorial belt. But since 1986, only the southern hemisphere has shown clouds; no bright features have been seen in the northern hemisphere. The equatorial region is not significantly darker than the northern midlatitudes. Discrete features are most obvious in the strongest methane band (8900 A), but brightness asymmetry is seen in weaker methane bands (7270 and 6190 A). Disk-integrated photometry obtained from the 1986 and 1987 imaging was calibrated absolutely with the same flux standard. In both years, variability at 8900 A was dominated by scattered light from a single bright cloud feature. The amplitude of the variability was a factor of two higher in 1987. The brightness of the less active hemisphere appears relatively constant between the two years, although some variability is seen on this hemisphere in 1987.

Hammel, H. B.↗

A one-equation turbulence transport model for high Reynolds number wall-bounded flows

A one-equation turbulence model that avoids the need for an algebraic length scale is derived from a simplified form of the standard-k-epsilon model equations. After calibration based on well established properties of the flow over a flat plate, predictions of several other flows are compared with experiment. The preliminary results presented indicate that the model has predictive and numerical properties of sufficient interest to merit further investigation and refinement. The one-equation model is also analyzed numerically and robust solution methods are presented.

Baldwin, Barrett S.↗

Differences between recalculated and original Dobson total ozone data from Hradec Kralove, Czechoslovakia, 1962-1990

Backward reevaluation of long-term total ozone measurements from the Solar and Ozone Observatory of Czech Hydrometeorological Institute at Hradec Kralove, Czechoslovakia, was performed for the period 1962-1990. The homogenization was carried out with respect to the calibration level of the World Primary Standard Spectrophotometer No. 83 - WPSS by means of day-by-day recalculations of more than 25,000 individual measurements using the R-N tables reconstructed after international comparisons and regular standard lamp tests of the Dobson spectrophotometer No. 74. The results showed significant differences among the recalculated data and those original ones published in the bulletins Ozone Data for the World. In the period 1962-1979 they reached 10-19 D.U. (3.0-5.5%) for annual averages and even 26 D.U. (7.0%) for monthly averages of total ozone. Such differences exceed several times accuracy of measuring and can significantly influence character of trends of total ozone in Central Europe. Therefore the results from Hradec Kralove support the calls for reevaluation of all historical Dobson total ozone data sets at individual stations of Global Ozone Observing System.

Vanicek, Karel↗

Thermal Emission Spectroscopy of 1 Ceres: Evidence for Olivine

Thermal emission spectra of the largest asteroid 1 Ceres obtained from the Kuiper Airborne Observatory display features that may provide information on its surface mineralogy. A plot of the Ceres spectrum (calibrated using alpha Boo as a standard) divided by a standard thermal model (STM) is shown. Also shown is the emissivity spectrum deduced from reflectivity measurements for olivine grains <5 microns in diameter. The general shape of the Ceres and the olivine curves agree in essential details, such as the maxima from 8 to 12 microns, the minimum between 12 and 14 microns, the broad peak near 17.5 micron, and the slope beyond 22 micron. (Use of the 10 to 15-micron grain reflectivities provides a better match to the 12- to 14-micron dip. We used a value of unity for beta, the beaming factor associated with small-scale surface roughness in our STM. Adjustment of beta to a lower value raises the long-wavelength side of the Ceres spectrum, providing an even better match to the olivine curve.) The emissivity behavior roughly matches the emission coefficients which were calculated for olivine particles with a particle radius of 3 microns. Their calculations show not only the negative slope from 23 to 25 pm, but a continued decrease past 30 micron. The Ceres emissivity is thus similar to that of small olivine grains from 8 to 30 micron, but olivine's emissivity is lower from 5 to 8 pm.

Witteborn, F. C.↗

In-flight Geometric Calibration Plan

This MISR in-flight Geometric Calibration (IGC) Plan describes the concept, development strategy and operational design to be used for geometric calibration of the instrument and for producing the Geometric Calibration Dataset (GCD) which is required as an input to the L1B2 standard processing.

geometric in-flight calibration plan↗

CLARREO Cornerstone of the Earth Observing System: Measuring Decadal Change Through Accurate Emitted Infrared and Reflected Solar Spectra and Radio Occultation

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is one of four Tier 1 missions recommended by the recent NRC Decadal Survey report on Earth Science and Applications from Space (NRC, 2007). The CLARREO mission addresses the need to provide accurate, broadly acknowledged climate records that are used to enable validated long-term climate projections that become the foundation for informed decisions on mitigation and adaptation policies that address the effects of climate change on society. The CLARREO mission accomplishes this critical objective through rigorous SI traceable decadal change observations that are sensitive to many of the key uncertainties in climate radiative forcings, responses, and feedbacks that in turn drive uncertainty in current climate model projections. These same uncertainties also lead to uncertainty in attribution of climate change to anthropogenic forcing. For the first time CLARREO will make highly accurate, global, SI-traceable decadal change observations sensitive to the most critical, but least understood, climate forcings, responses, and feedbacks. The CLARREO breakthrough is to achieve the required levels of accuracy and traceability to SI standards for a set of observations sensitive to a wide range of key decadal change variables. The required accuracy levels are determined so that climate trend signals can be detected against a background of naturally occurring variability. Climate system natural variability therefore determines what level of accuracy is overkill, and what level is critical to obtain. In this sense, the CLARREO mission requirements are considered optimal from a science value perspective. The accuracy for decadal change traceability to SI standards includes uncertainties associated with instrument calibration, satellite orbit sampling, and analysis methods. Unlike most space missions, the CLARREO requirements are driven not by the instantaneous accuracy of the measurements, but by accuracy in the large time/space scale averages that are key to understanding decadal changes.

Sandford, Stephen P.↗

Checking AIRS nonlinearity in flight

Radiances from the Atmospheric Infrared Sounder (AIRS) show excellent stability and are traceable to SI standards through the On-Board Calibrator (OBC) blackbody. The OBC can be used to check the nonlinearity by turning off the heater and letting the target float from 308K to roughly 261K while acquiring data. The OBC Float test was performed once prior to launch, and again shortly after launch. Until now, the OBC Float test did not produce accurate nonlinearity results.

Aumann, Hartmut↗

A New Framework for Quantifying Lidar Uncertainty

As wind turbine sizes increase and wind energy expands to more complex and remote sites, remote sensing devices such as lidars are expected to play a key role in wind resource assessment and power performance testing. The switch to remote sensing devices represents a paradigm shift in the way the wind industry typically obtains and interprets measurement data for wind energy. For example, the measurement techniques and sources of uncertainty for a remote sensing device are vastly different from those associated with a cup anemometer on a meteorological tower. Current IEC standards discuss uncertainty due to mounting, calibration, and classification of the remote sensing device, among other parameters. Values of the uncertainty are typically given as a function of the mean wind speed measured by a reference device. However, real-world experience has shown that lidar performance is highly dependent on atmospheric conditions, such as wind shear, turbulence, and aerosol content. At present, these conditions are not directly incorporated into the estimated uncertainty of a lidar device. In this presentation, we propose the development of a new lidar uncertainty framework that adapts to current flow conditions and more accurately represents the actual uncertainty inherent in lidar measurements under different conditions. In this new framework, sources of uncertainty are identified for estimation of the line-of-sight wind speed and reconstruction of the three-dimensional wind field. These sources are then related to physical processes caused by the atmosphere and lidar operating conditions. The framework is applied to lidar data from an operational wind farm to assess the ability of the framework to predict errors in lidar-measured wind speed.

17 WIND ENERGY↗

Standard Candles for Supernova Neutrino Detection at DUNE

The Deep Underground Neutrino Experiment (DUNE) far detector is sensitive to $\mathcal{O}(10)$ MeV electron neutrinos through $ν_e$ charged-current reaction with argon. This capability is a unique window into the $ν_e$ component of a Galactic core-collapse supernova flux. Extracting the properties of the supernova spectrum is, however, limited by the poorly-known $ν_e$-Ar cross section. We propose a data-driven strategy that leverages $^8$B solar neutrinos and muon-decay-at-rest neutrinos as standard candles for this process. These calibration samples constrain both the low-energy and high-energy components of the cross section relevant for supernova detection. Our method reduces the reliance on nuclear models, which can bias the extraction of the spectral parameters by as much as 300$\%$.

Cheng, Ting [Fermilab]↗

Far ultraviolet spectral radiance calibrations at NBS.

The range of NBS radiometric calibration services has been extended into the far ultraviolet region of the spectrum where a dc high-power hydrogen wall-stabilized arc is used as a primary standard of spectral radiance. A capability in the range from 130 to 360 nm (overlapping conventional tungsten strip lamp radiometry) is presently available with estimated uncertainties between 5 and 10%, depending upon wavelength. The status of radiometric source standards in the far ultraviolet is briefly reviewed, and the hydrogen arc and NBS calibration facility are described in detail. The use of commercially available mercury Krefft-Rossler lamps and deuterium arc lamps as transfer or secondary standards is discussed, and the spectra of these lamps calibrated with the hydrogen arc standard are presented.

Ott, W. R.↗

Quantitative Analysis of Ca, Mg, and K in the Roots of Angelica pubescens f. biserrata by Laser-Induced Breakdown Spectroscopy Combined with Artificial Neural Networks

Laser-induced breakdown spectroscopy has been applied for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens Maxim. f. biserrata Shan et Yuan used in traditional Chinese medicine. Ca II 317.993 nm, Mg I 517.268 nm, and K I 769.896 nm spectral lines have been chosen to set up calibration models for the analysis using the external standard and artificial neural network methods. The linear correlation coefficients of the predicted concentrations versus the standard concentrations of six samples determined by the artificial neural network method are 0.9896, 0.9945, and 0.9911 for Ca, Mg, and K, respectively, which are better than for the external standard method. The artificial neural network method also gives better performance comparing with the external standard method for the average and maximum relative errors, average relative standard deviations, and most maximum relative standard deviations of the predicted concentrations of Ca, Mg, and K in the six samples. Finally, it is proved that the artificial neural network method gives better performance compared to the external standard method for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NREL Pyrheliometer Comparisons: September 22-26, 2014 (NPC-2014)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. As with all measurement systems, absolute cavity radiometers and other types of pyrheliometers are subject to performance changes over time. NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the World Radiometric Reference (WRR), and uses these reference instruments to calibrate pyrheliometers and pyranometers using the ISO 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process. National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2014 was held September 22-26, 2014. Participants operated 36 absolute cavity radiometers and 22 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal solar irradiance during this period, and this report documents the findings.

14 SOLAR ENERGY↗

Clusters of Monoisotopic Elements for Calibration in (TOF) Mass Spectrometry

Precise calibration in TOF MS requires suitable and reliable standards, which are not always available for high masses. We evaluated inorganic clusters of the monoisotopic elements gold and phosphorus (Au{sub n}{sup +}/Au{sub n}{sup -} and P{sub n}{sup +}/P{sub n}{sup -}) as an alternative to peptides or proteins for the external and internal calibration of mass spectra in various experimental and instrumental scenarios. Monoisotopic gold or phosphorus clusters can be easily generated in situ from suitable precursors by laser desorption/ionization (LDI) or matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Their use offers numerous advantages, including simplicity of preparation, biological inertness, and exact mass determination even at lower mass resolution. We used citrate-stabilized gold nanoparticles to generate gold calibration clusters, and red phosphorus powder to generate phosphorus clusters. Both elements can be added to samples to perform internal calibration up to mass-to-charge (m/z) 10–15,000 without significantly interfering with the analyte. We demonstrated the use of the gold and phosphorous clusters in the MS analysis of complex biological samples, including microbial standards and total extracts of mouse embryonic fibroblasts. We believe that clusters of monoisotopic elements could be used as generally applicable calibrants for complex biological samples. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable zero-delay assembly

Instrument is calibrated using back-to-back method. In comparison standard, S-X isolators are opposite from device being tested to permit signal flow in reverse direction. After calibration portable zero-delay assembly (PZDA) is used to set time delays of deep-space network ground-station ranging systems. Approach is also used to calibrate microwave links in other communications systems.

Franco, M. M.↗

Photometric calibration of the International Ultraviolet Explorer (IUE) at low resolution - The LWP camera

We present and discuss the low resolution absolute calibration for the LWP camera of the International Ultraviolet Explorer (IUE). The calibration, implemented in routine processing of LWP low resolution images on December 22, 1987 at both GSFC and VILSPA IUE ground stations, is based on the last set of Intensity Transfer Function (ITF 2) obtained in September 1984 and on a substantially larger amount of IUE observations of standard stars than used for the preliminary calibration by Cassatella & Harris (1983) based on the earlier ITF (ITF 1). The new ITF and the associated calibration provide upgraded performances in flux accuracy, signal-to-noise ratio and linearity with respect to the earlier LWP ITF1 which was implemented in processing LWP data obtained in the period from October 16, 1983 until December 21, 1987.

Cassatella, A.↗

APASS Landolt-Sloan BVgri photometry of Rave stars. I. Data, effective temperatures, and reddenings

We provide AAVSO Photometric All-Sky Survey (APASS) photometry in the Landolt BV and Sloan g'r'i' bands for all 425,743 stars included in the fourth RAVE Data Release. The internal accuracy of the APASS photometry of RAVE stars, expressed as the error of the mean of data obtained and separately calibrated over a median of four distinct observing epochs and distributed between 2009 and 2013, is 0.013, 0.012, 0.012, 0.014, and 0.021 mag for the B, V, g', r', and i' bands, respectively. The equally high external accuracy of APASS photometry has been verified on secondary Landolt and Sloan photometric standard stars not involved in the APASS calibration process and on a large body of literature data on field and cluster stars, confirming the absence of offsets and trends. Compared with the Carlsberg Meridian Catalog (CMC-15), APASS astrometry of RAVE stars is accurate to a median value of 0.098 arcsec. Brightness distribution functions for the RAVE stars have been derived in all bands. APASS photometry of RAVE stars, augmented by 2MASS JHK infrared data, has been χ{sup 2} fitted to a densely populated synthetic photometric library designed to widely explore temperature, surface gravity, metallicity, and reddening. Resulting T {sub eff} and E {sub B–V}, computed over a range of options, are provided and discussed, and will be kept updated in response to future APASS and RAVE data releases. In the process, we find that the reddening caused by a homogeneous slab of dust, extending for 140 pc on either side of the Galactic plane and responsible for E{sub B−V}{sup poles} = 0.036 ± 0.002 at the Galactic poles, is a suitable approximation of the actual reddening encountered at Galactic latitudes |b| ≥ 25°.

79 ASTRONOMY AND ASTROPHYSICS↗

Flux Sensor Measurement and Calibration Requirements for High-Intensity Heat Flux Applications: A Trade Study

Stakeholders of CSP and non-CSP high-intensity broadband flux measurements were surveyed and interviewed to obtain flux sensor design and calibration requirements. Existing sensor technologies and existing calibration facilities were then compared against this standard. Stakeholders require a flux sensor designed for >5,000 kW/m2 flux measurements, >1,000 life cycles, <500 ms response time, >60-minute exposure at maximum flux, and <5% measurement uncertainty. Stakeholders also require a sensor with minimal cost, short procurement lead time, and a high-intensity broadband flux calibration. Commercial CSP stakeholders primarily rely on infrared (IR) temperature measurements of receiver equipment to control CSP plant process operation, whereas CSP research and development (R&D) and non-CSP stakeholders rely on accurate flux gauge measurements for a variety of applications. It was determined that existing flux sensor technologies and calibration facilities do not comprehensively meet stakeholder needs. This study suggests a more robust circular foil gauge with a high-intensity solar flux calibration comprehensively meets stakeholder flux measurement needs. Improved circular foil gauge designs and an improved flux sensor calibration facility are discussed.

McLaughlin, Luke (ORCID:0000000303711310)↗

EUNIS Underflight Calibrations of CDS, EIT, TRACE, EIS, and EUVI

The Extreme-Ultraviolet Normal-Incidence Spectrograph (EUNIS) is a sounding rocket instrument that obtains imaged high-resolution solar spectra. It has now had two successful flights, on 2006 April 12 and 2007 November 16, providing data to support underflight calibrations for a number of orbiting solar experiments on both occasions. A regular part of each campaign is the end-to-end radiometric calibration of the rocket payload carried out at RAL in the UK, using the same facility that provided pre-flight CDS and EIS calibrations. The measurements, traceable to primary radiometric standards, can establish the absolute EUNIS response within a total uncertainty of 10% over its full longwave bandpass of 300-370A. During each EUNIS flight, coordinated observations are made of overlapping solar locations by all participating space experiments, and identified by subsequent image co-registrations, allowing the EUNIS calibrations to be applied to these other instruments as well. The calibration transfer is straightforward for wavelengths within the EUNIS LW bandpass, and is extended to other wavelengths by means of a series of temperature- and density-insensitive line-ratios, with one line of each pair in the calibrated band and the other in the transfer band. In this way, the EUNIS-06 flight is able to update the radiometric calibrations of CDS NISl (and 2nd-order NIS2 near 2x304A), all four channels of EIT, and the three EUV channels of TRACE. The EUNIS-07 flight will further update those missions, as well as both channels of Hinode/EIS and all four channels of STEREO/SECCHI/EUVI. Future EUNIS flights have been proposed that will continue this underflight calibration service. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

Thomas, Roger J.↗