Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Radial Velocity Detection of Extra-Solar Planetary Systems

The McDonald Observatory Planetary Search (MOPS) was designed to search for Jovian-mass planets in orbit around solar-type stars by making high-precision measurements of the Radial Velocity (RV) of a star, to attempt to detect the reflex orbital motion of the star around the star-planet barycenter. In our solar system, the velocity of the Sun around the Sun-Jupiter barycenter averages 12.3 m/ s. The MOPS survey started operation in September 1987, and searches 36 bright, nearby, solar-type dwarfs to 10 m/s precision. The survey was started using telluric O2 absorption lines as the velocity reference metric. Observations use the McDonald Observatory 2.7-m Harlan Smith Telescope coude spectrograph with the six-foot camera. This spectrograph configuration isolates a single order of the echelle grating on a Texas Instruments 800 x 800 CCD. The telluric line method gave us a routine radial velocity precision of about 15 m/s for stars down to about 5-th magnitude. However, the data obtained with this technique suffered from some source of long-term systematic errors, which was probably the intrinsic velocity variability of the terrestrial atmosphere, i.e. winds. In order to eliminate this systematic error and to improve our overall measurement precision, we installed a stabilized I2 gas absorption cell as the velocity metric for the MOPS in October 1990. In use at the telescope, the cell is placed directly in front of the spectrograph entrance slit, with starlight passing through the cell. The use of this sealed stabilized I2 cell removes potential problems with possible long-term drifts in the velocity metric. The survey now includes a sample of 36 nearby F, G, and K type stars of luminosity class V or IV-V.

Cochran, William D.↗

The explosive transient camera (ETC) - An instrument for identification of gamma ray burst optical counterparts

The ETC is a wide-field (3-steradian) electronic camera array which can detect coincident optical flashes with durations of 0.1 to 100 sec. Each array element is a 20 x 30 deg FOV, cooled CCD detector. An optical transient (possibly associated with a gamma ray burst) as faint as B = +11 (1 sec duration) can be detected with an S/N of not less than 20, and its position determined to an accuracy of + or - 10 arcsec. Candidate events 1000 times fainter than the archived event (plate taken in 1928) reported for the November 19, 1978 gamma ray burst by Schaefer (1981) should be detectable in real time. A prototype camera was tested in April 1982 to establish sky background levels and spurious event rejection schemes; a 1/2-ster test version of the ETC was planned for operation in early 1984; expansion to the full 3-ster complement of 16 detectors at each of two sites was planned for the 1984-1985 period.

Ricker, G. R.↗

Initial Results of Transverse Beam Profile Measurements Using a LYSO:Ce Crystal

A prototype transverse beam profile monitor for eventual use at the Advanced Superconducting Test Accelerator (ASTA) has been tested at the Fermilab A0 Photoinjector. Results from low-charge (20 pC) studies indicate that a LYSO:Ce scintillator will be a viable alternative to a YAG:Ce scintillator when using intercepting radiation convertor screens for beam profiling. We will also describe the planned implementation of LYSO:Ce crystals to mitigate the coherent optical transition radiation due to the microbunching instability through the use of band-pass filters and specially timed cameras. Based upon tests conducted at the A0PI, we can conclude that the LYSO:Ce crystal will be a suitable alternative to the YAG:Ce crystal for beam imaging. The YAG:Ce and LYSO:Ce crystals both offer similar performance characteristics for low charge beam, but LYSO:Ce combined with a violet bandpass filter has the added benefit of mitigating the COTR due to themicrobunching instability in beam images. The OTR screen can also be used to avoid the scintillator saturation at high areal charge density and the thin foils generate less beam scattering. If the use of bandpass filters, CCD shutter timing and LYSO:Ce are not enough to reduce the COTR due to the microbunching instability, we could use a gated, intensified camera.

43 PARTICLE ACCELERATORS↗

Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results of the Athena Microscopic Imager Investigation

The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI). The MI is a fixed-focus camera mounted on an extendable arm, the Instrument Deployment Device (IDD). The MI acquires images at a spatial resolution of 30 microns/pixel over a broad spectral range (400 - 700 nm). The MI uses the same electronics design as the other MER cameras but its optics yield a field of view of 31 x 31 mm across a 1024 x 1024 pixel CCD image. The MI acquires images using only solar or skylight illumination of the target surface. A contact sensor is used to place the MI slightly closer to the target surface than its best focus distance (about 69 mm), allowing concave surfaces to be imaged in good focus. Coarse focusing (approx. 2 mm precision) is achieved by moving the IDD away from a rock target after contact is sensed. The MI optics are protected from the Martian environment by a retractable dust cover. This cover includes a Kapton window that is tinted orange to restrict the spectral bandpass to 500 - 700 nm, allowing crude color information to be obtained by acquiring images with the cover open and closed. The MI science objectives, instrument design and calibration, operation, and data processing were described by Herkenhoff et al. Initial results of the MI experiment on both MER rovers ('Spirit' and 'Opportunity') are described below.

Herkenhoff, K.↗

THE PROPER MOTION OF PALOMAR 5

Palomar 5 (Pal 5) is a faint halo globular cluster associated with narrow tidal tails. It is a useful system to understand the process of tidal dissolution, as well as to constrain the potential of the Milky Way. A well-determined orbit for Pal 5 would enable detailed study of these open questions. We present here the first CCD-based proper motion measurement of Pal 5 obtained using SDSS as a first epoch and new Large Binocular Telescope/Large Binocular Camera (LBC) images as a second, giving a baseline of 15 years. We perform relative astrometry, using SDSS as a distortion-free reference, and images of the cluster and also of the Pal 5 stream for the derivation of the distortion correction for LBC. The reference frame is made up of background galaxies. We correct for differential chromatic refraction using relations obtained from SDSS colors as well as from flux-calibrated spectra, finding that the correction relations for stars and for galaxies are different. We obtain μ{sub α} = −2.296 ± 0.186 mas yr{sup −1} and μ{sub δ} = −2.257 ± 0.181 mas yr{sup −1} for the proper motion of Pal 5. We use this motion, and the publicly available code galpy, to model the disruption of Pal 5 in different Milky Way models consisting of a bulge, a disk, and a spherical dark matter halo. Our fits to the observed stream properties (streak and radial velocity gradient) result in a preference for a relatively large Pal 5 distance of around 24 kpc. A slightly larger absolute proper motion than what we measure also results in better matches but the best solutions need a change in distance. We find that a spherical Milky Way model, with V{sub 0} = 220 km s{sup −1} and V{sub 20} {sub kpc}, i.e., approximately at the apocenter of Pal 5, of 218 km s{sup −1}, can match the data well, at least for our choice of disk and bulge parametrization.

79 ASTRONOMY AND ASTROPHYSICS↗

The Athena Microscopic Imager Investigation

The Athena science payload on the Mars Exploration Rovers (MER) includes the Microscopic Imager (MI) [1]. The MI is a fixed-focus camera mounted on the end of an extendable instrument arm, the Instrument Deployment Device (IDD; see Figure 1).The MI was designed to acquire images at a spatial resolution of 30 microns/pixel over a broad spectral range (400 - 700 nm; see Table 1). Technically, the microscopic imager is not a microscope: it has a fixed magnification of 0.4 and is intended to produce images that simulate a geologist s view through a common hand lens. In photographers parlance, the system makes use of a macro lens. The MI uses the same electronics design as the other MER cameras [2, 3] but has optics that yield a field of view of 31 31 mm across a 1024 1024 pixel CCD image (Figure 2). The MI acquires images using only solar or skylightillumination of the target surface. A contact sensor is used to place the MI slightly closer to the target surface than its best focus distance (about 66 mm), allowing concave surfaces to be imaged in good focus. Because the MI has a relatively small depth of field (3 mm), a single MI image of a rough surface will contain both focused and unfocused areas. Coarse focusing will be achieved by moving the IDD away from a rock target after the contact sensor is activated. Multiple images taken at various distances will be acquired to ensure good focus on all parts of rough surfaces. By combining a set of images acquired in this way, a completely focused image can be assembled. Stereoscopic observations can be obtained by moving the MI laterally relative to its boresight. Estimates of the position and orientation of the MI for each acquired image will be stored in the rover computer and returned to Earth with the image data. The MI optics will be protected from the Martian environment by a retractable dust cover. The dust cover includes a Kapton window that is tinted orange to restrict the spectral bandpass to 500-700 nm, allowing color information to be obtained by taking images with the dust cover open and closed. The MI will image the same materials measured by other Athena instruments (including surfaces prepared by the Rock Abrasion Tool), as well as rock and soil targets of opportunity. Subsets of the full image array can be selected and/or pixels can be binned to reduce data volume. Image compression will be used to maximize the information contained in the data returned to Earth. The resulting MI data will place other MER instrument data in context and aid in petrologic and geologic interpretations of rocks and soils on Mars.

K E Herkenhoff↗

Chromatic Modulator for a High-Resolution CCD or APS

A chromatic modulator has been proposed to enable the separate detection of the red, green, and blue (RGB) color components of the same scene by a single charge-coupled device (CCD), active-pixel sensor (APS), or similar electronic image detector. Traditionally, the RGB color-separation problem in an electronic camera has been solved by use of either (1) fixed color filters over three separate image detectors; (2) a filter wheel that repeatedly imposes a red, then a green, then a blue filter over a single image detector; or (3) different fixed color filters over adjacent pixels. The use of separate image detectors necessitates precise registration of the detectors and the use of complicated optics; filter wheels are expensive and add considerably to the bulk of the camera; and fixed pixelated color filters reduce spatial resolution and introduce color-aliasing effects. The proposed chromatic modulator would not exhibit any of these shortcomings. The proposed chromatic modulator would be an electromechanical device fabricated by micromachining. It would include a filter having a spatially periodic pattern of RGB strips at a pitch equal to that of the pixels of the image detector. The filter would be placed in front of the image detector, supported at its periphery by a spring suspension and electrostatic comb drive. The spring suspension would bias the filter toward a middle position in which each filter strip would be registered with a row of pixels of the image detector. Hard stops would limit the excursion of the spring suspension to precisely one pixel row above and one pixel row below the middle position. In operation, the electrostatic comb drive would be actuated to repeatedly snap the filter to the upper extreme, middle, and lower extreme positions. This action would repeatedly place a succession of the differently colored filter strips in front of each pixel of the image detector. To simplify the processing, it would be desirable to encode information on the color of the filter strip over each row (or at least over some representative rows) of pixels at a given instant of time in synchronism with the pixel output at that instant.

Hartley, Frank↗

Search for near-Earth asteroids with the spacewatch camera

The Spacewatch Program began as an engineering development of the discovery of near-earth asteroids and comets, with the firs observations starting in 1983, using an RCA charge coupled device (CCD) that has 320 x 512 pixels. Extensive software was written to scan the sky and learn how to do astrometry for precise orbits of newly discovered objects. The merit of the concept was proven, with many observations reported and comets recovered. The precision of astrometric observations for comets and asteroids was improved. For efficient scanning and discovery of new objects, a Tektronix 2048 x 2048 CCD was obtained and is now permanently on the Spacewatch Telescope. Other aspects of the Spacewatch Program are briefly discussed.

Gehrels, T.↗

Is flat fielding safe for precision CCD astronomy?

The ambitious goals of precision cosmology with wide-field optical surveys such as the Dark Energy Survey (DES) and the Large Synoptic Survey Telescope (LSST) demand precision CCD astronomy as their foundation. This in turn requires an understanding of previously uncharacterized sources of systematic error in CCD sensors, many of which manifest themselves as static effective variations in pixel area. Such variation renders a critical assumption behind the traditional procedure of flat fielding—that a sensor's pixels comprise a uniform grid—invalid. In this work, we present a method to infer a curl-free model of a sensor's underlying pixel grid from flat-field images, incorporating the superposition of all electrostatic sensor effects—both known and unknown—present in flat-field data. We use these pixel grid models to estimate the overall impact of sensor systematics on photometry, astrometry, and PSF shape measurements in a representative sensor from the Dark Energy Camera (DECam) and a prototype LSST sensor. Applying the method to DECam data recovers known significant sensor effects for which corrections are currently being developed within DES. For an LSST prototype CCD with pixel-response non-uniformity (PRNU) of 0.4%, we find the impact of "improper" flat fielding on these observables is negligible in nominal .7'' seeing conditions. Furthermore, these errors scale linearly with the PRNU, so for future LSST production sensors, which may have larger PRNU, our method provides a way to assess whether pixel-level calibration beyond flat fielding will be required.

79 ASTRONOMY AND ASTROPHYSICS↗

A new approach for performing contamination control bakeouts in JPL thermal vacuum test chambers

Contamination control requirements for the Wide Field/Planetary Camera II (WF/PC II) are necessarily stringent to protect against post-launch contamination of the sensitive optical surfaces, particularly the cold charge coupled device (CCD) imaging surfaces. Typically, thermal vacuum test chambers have employed a liquid nitrogen (LN2) cold trap to collect outgassed contaminants. This approach has the disadvantage of risking recontamination of the test article from shroud offgassing during post-test warmup of the chamber or from any shroud warming of even a few degrees during the bakeout process. By using an enclave, essentially a chamber within a chamber, configured concentrically and internally within an LN2 shroud, a method was developed, based on a design concept by Taylor, for preventing recontamination of test articles during bakeouts and subsequent post-test warmup of the vacuum chamber. Enclaves for testing WF/PC II components were designed and fabricated, then installed in three of JPL's Environmental Test Lab chambers. The design concepts, operating procedures, and test results of this development are discussed.

Johnson, Kenneth R.↗

Observations of the Jovian System with the Chandra X-Ray Observatory

The {\sl Chandra X-ray Observatory) observed the Jovian system on 25-26 Nov 1999 with the Advanced CCD Imaging Spectrometer (ACIS), in support of the Galileo flyby of Io, and on 18 Dec 2000 with the imaging array of the High Resolution Camera (HRC-I), in support of the Cassini flyby of Jupiter. These sensitive, very high spatial-resolution X-ray observations have revealed that Jupiter's northern x-ray aurora originates at a spot fixed in a coordinate system rotating with the planet at latitude (60--70 deg north) and longitude (160--180 deg System III). Contrary to previous expectations, this location is poleward of the main FUV auroral oval and the foot of the Io Flux Tube, and is apparently connected magnetically to a region of the outer magnetosphere beyond $\sim$30 Jupiter radii. The northern auroral x-ray emission varies with a period $\sim$45 minute and has a an average power of $\sim$1 GW. The earlier view that Jupiter's x-ray aurora resulted from the precipitation of heavy ions from the outer edge of the lo Plasma Torus is now in doubt. Jupiter's disk also emits x-rays with a power of $\sim$2 GW, perhaps resulting from reprocessing of solar x-rays in its atmosphere. These observations reveal for the first time x-ray emission from the Io Plasma Torus, with a power of $\sim$0.1 Gw. The origin of this emission is not currently understood, although bremmstrahlung from non-thermal electrons may play a significant role. Finally, we report the discovery of very faint ($\sim$1--2 MW) soft x-ray emission from the Galilean satellites Io, Europa, and probably Ganymede, most likely as a result of bombardment of their surfaces by energetic ($ greater than $10 keV) H, O, and S ions from the region of the Io Plasma Torus.

Elsner, R. F.↗

The Dark Energy Camera (DECam)

In this paper we describe the Dark Energy Camera (DECam), which will be the primary instrument used in the Dark Energy Survey. DECam will be a 3 sq. deg. mosaic camera mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). It consists of a large mosaic CCD focal plane, a five element optical corrector, five filters (g,r,i,z,Y), a modern data acquisition and control system and the associated infrastructure for operation in the prime focus cage. The focal plane includes of 62 2K x 4K CCD modules (0.27"/pixel) arranged in a hexagon inscribed within the roughly 2.2 degree diameter field of view and 12 smaller 2K x 2K CCDs for guiding, focus and alignment. The CCDs will be 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). Production of the CCDs and fabrication of the optics, mechanical structure, mechanisms, and control system for DECam are underway; delivery of the instrument to CTIO is scheduled for 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Poster — Thur Eve — 18: Cherenkov Emission By High-Energy Radiation Therapy Beams: A Characterization Study

We investigate Cherenkov emission (CE) by radiotherapy beams via radiation dose-versus-CE correlation analyses, CE detection optimization by means of a spectral shift towards the near-infrared (NIR) window of biological tissue, and comparison of CE to on-board MV imaging. Dose-CE correlation was investigated via simulation and experiment. A Monte Carlo (MC) CE simulator was designed using Geant4. Experimental phantoms include: water; tissue-simulating phantom composed of water, Intralipid®, and beef blood; plastic phantom with solid water insert. The detector system comprises an optical fiber and diffraction-grating spectrometer incorporating a front/back-illuminated CCD. The NIR shift was carried out with CdSe/ZnS quantum dots (QDs), emitting at (650±10) nm. CE and MV images were acquired with a CMOS camera and electronic portal imaging device. MC and experimental studies indicate a strong linear dose-CE correlation (Pearson coefficient > 0.99). CE by an 18-MeV beam was effectively NIR-shifted in water and a tissue-simulating phantom, exhibiting a significant increase at 650 nm for QD depths up to 10 mm. CE images exhibited relative contrast superior to MV images by a factor of 30. Our work supports the potential for application of CE in radiotherapy online imaging for patient setup and treatment verification, since CE is intrinsic to the beam and non-ionizing and QDs can be used to improve CE detectability, potentially yielding image quality superior to MV imaging for the case of low-density-variability, low-optical-attenuation materials (ex: breast/oropharynx). Ongoing work involves microenvironment functionalization of QDs and application of multi-channel spectrometry for simultaneous acquisition of dosimetric and tumor oxygenation signals.

07 ISOTOPE AND RADIATION SOURCES↗

Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis

We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISAR optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wideband comet camera lens design

A quarter-meter diameter, modified Ritchey-Chretien camera is described for spacecraft-based observation of Halley's Comet. The system will operate over an unusually broad spectral region, from 0.1216 micron (the hydrogen Lyman-alpha line) to 1.1 microns using reflective primary and secondary mirror optics and a thin UV-grade lithium fluoride refractive element as a field corrector near the image plane. The f/12, 3000 mm focal length camera has a 0.4 deg full field of view for operation with a 15 x 15 mm charge-coupled device detector array. The UV-enhanced silicon CCD detector is a 1000 x 1000 array of 15 micron pixels which establishes the system resolution requirement. The optical design and performance are discussed, with an emphasis on the image analysis with respect to pixel resolution elements used for viewing extended objects such as comets.

Huber, E. D.↗

The Hubble Space Telescope extragalactic distance scale key project. 2: Photometry of WFC images of M81

The Extragalactic Distance Scale (H(sub o)) Key Project for Hubble Space Telescope (HST) aims to employ the Cepheid period-luminosity (P-L) relation to measure galaxy distances out as far as the Virgo Cluster. The vital steps in this program are (1) to obtain precise photometry of stellar images from the Wide Field Camera (WFC) exposures of selected galaxies, and (2) to calibrate this photometry to obtain reliable distances to these galaxies from the Cepheid P-L relation. We have used the DAOPHOT II and ALLFRAME programs to determine 28 instrumental magnitudes -- 22 of F555W (of about V) and six of F785LP (of about I) -- of all stars brighter than V of about 25 in each of two 2.56 arcmin x 2.56 arcmin WFC fields of M81. The reductions use a varying point-spread function to account for the field effects in the WFC optics and yield instrumental magnitudes with single epoch precision ranging from 0.09 to 0.24 mag, at V of about 21.8 to 23.8 -- the magnitude range of the 30 Cepheids that we have now identified in M81. For brighter stars (V of about 22), single epoch magnitudes are precise to 0.09 mag. The photometric calibration onto the Johnson V and Kron-Cousins I systems was determined from independent ground-based CCD observing at the Canada-France-Hawaii Telescope (CFHT) 3.6 m (confirmed by the Kitt Peak National Observatory (KPNO) 4.0 m) and from the Palomar 5.0 m (using the wide-field COSMIC camera) and 1.5 m telescopes. Secondary standards, taken from the COSMIC and CFHT frames, were established in each of the WFC fields in V and I, allowing a direct transformation from ALLFRAME magnitudes to calibrated V and I magnitudes, giving mean V of about 23 magnitudes accurate to of about +/- 0.1 mag. The stellar populations in M81 have been analyzed in terms of the luminosity functions and color magnitude diagrams (CMD) derived from these data, from which we identify numerous supergiants, and a CMD morphology similar to M33.

Hughes, Shaun M. G.↗