Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPARTMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Precipitation of ACC in liposomes-a model for biomineralization in confined volumes

Biomineralizing organisms frequently precipitate minerals in small phospholipid bilayer-delineated compartments. We have established an in vitro model system to investigate the effect of confinement in attoliter to femtoliter volumes on the precipitation of calcium carbonate. In particular, we analyze the growth and stabilization of liposome-encapsulated amorphous calcium carbonate (ACC) nanoparticles using a combination of in situ techniques, cryo-transmission electron microscopy (Cryo-TEM), and small angle X-ray scattering (SAXS). Herein, we discuss ACC nanoparticle growth rate as a function of liposome size, carbon dioxide flux across the liposome membrane, pH, and osmotic pressure. Based on these experiments, we argue that the stabilization of ACC nanoparticles in liposomes is a consequence of a low nucleation rate (high activation barrier) of crystalline polymorphs of calcium carbonate.

Tester, Chantel C↗

Exploring the structural basis for selenium/mercury antagonism in Allium fistulosum

While continuing efforts are devoted to studying the mutually protective effect of mercury and selenium in mammals, few studies have investigated the mercury-selenium antagonism in plants. In this study, we report the metabolic fate of mercury and selenium in Allium fistulosum (green onion) after supplementation with sodium selenite and mercuric chloride. Analysis of homogenized root extracts via capillary reversed phase chromatography coupled with inductively coupled plasma mass spectrometry (capRPLC-ICP-MS) suggests the formation of a mercury-selenium containing compound. Micro-focused synchrotron X-ray fluorescence mapping of freshly excised roots show Hg sequestered on the root surface and outlining individual root cells, while Se is more evenly distributed throughout the root. There are also discrete Hg-only, Se-only regions and an overall strong correlation between Hg and Se throughout the root. Analysis of the X-ray absorption near edge structure (XANES) spectra show a 'background' of methylselenocysteine within the root with discrete spots of SeO{sub 3}{sup 2-}, Se{sup 0} and solid HgSe on the root surface. Mercury outlining individual root cells is possibly binding to sulfhydryl groups or plasma membrane or cell wall proteins, and in some places reacting with reduced selenium in the rhizosphere to form a mercury(II) selenide species. Together with the formation of the root-bound mercury(II) selenide species, we also report on the formation of cinnabar (HgS) and Hg{sup 0} in the rhizosphere. The results presented herein shed light on the intricate chemical and biological processes occurring within the rhizosphere that influence Hg and Se bioavailability and will be instrumental in predicting the fate and assisting in the remediation of these metals in the environment and informing whether or not fruit and vegetable food selection from aerial plant compartments or roots from plants grown in Hg contaminated soils, are safe for consumption.

54 ENVIRONMENTAL SCIENCES↗

Photoelectrochemistry of core–shell tandem junction n–p + -Si/n-WO 3 microwire array photoelectrodes

Tandem junction (n–p + -Si/ITO/WO 3 /liquid) core–shell microwire devices for solar-driven water splitting have been designed, fabricated and investigated photoelectrochemically. The tandem devices exhibited open-circuit potentials of E oc = –1.21 V versus E 0 '(O 2 /H 2 O), demonstrating additive voltages across the individual junctions (n–p + -Si E oc = –0.5 V versus solution; WO 3 /liquid E oc = –0.73 V versus E 0 '(O 2 /H 2 O)). Optical concentration (12×, AM1.5D) shifted the open-circuit potential to E oc = –1.27 V versus E 0 '(O 2 /H 2 O) and resulted in unassisted H 2 production during two-electrode measurements (anode: tandem device, cathode: Pt disc). Here, the solar energy-conversion efficiencies were very low, 0.0068% and 0.0019% when the cathode compartment was saturated with Ar or H 2 , respectively, due to the non-optimal photovoltage and band-gap of the WO 3 that was used in the demonstration system to obtain stability of all of the system components under common operating conditions while also insuring product separation for safety purposes.

Shaner, Matthew R.↗

A multi-scale approach to designing therapeutics for tuberculosis

Approximately one third of the world’s population is infected with Mycobacterium tuberculosis . Limited information about how the immune system fights M. tuberculosis and what constitutes protection from the bacteria impact our ability to develop effective therapies for tuberculosis. We present an in vivo systems biology approach that integrates data from multiple model systems and over multiple length and time scales into a comprehensive multi-scale and multi-compartment view of the in vivo immune response to M. tuberculosis . Lastly, we describe computational models that can be used to study (a) immunomodulation with the cytokines tumor necrosis factor and interleukin 10, (b) oral and inhaled antibiotics, and (c) the effect of vaccination.

59 BASIC BIOLOGICAL SCIENCES↗

IR-Live: fabrication of a low-cost plastic microfluidic device for infrared spectromicroscopy of living cells

Water is a strong mid-infrared absorber, which has hindered the full exploitation of label-free and non-invasive infrared (IR) spectromicroscopy techniques for the study of living biological samples. To overcome this barrier, many researchers have built sophisticated fluidic chambers or microfluidic chips wherein the depth of the liquid medium in the sample compartment is limited to 10 μm or less. We report an innovative and simple way to fabricate plastic devices with infrared transparent view-ports enabling infrared spectromicroscopy of living biological samples; therefore the device is named “IR-Live”. Advantages of this approach include lower production costs, a minimal need to access a micro-fabrication facility, and unlimited mass or waste exchange for the living samples surrounding the view-port area. We demonstrate that the low-cost IR-Live in combination with microfluidic perfusion techniques enables long term (>60 h) cell culture, which broadens the capability of IR spectromicroscopy for studying living biological samples. To illustrate this, we first applied the device to study protein and lipid polarity in migrating REF52 fibroblasts by collecting 2-dimensional spectral chemical maps at a micrometer spatial resolution. Then, we demonstrated the suitability of our approach to study dynamic cellular events by collecting a time series of spectral maps of U937 monocytes during the early stage of cell attachment to a bio-compatible surface.

47 OTHER INSTRUMENTATION↗

C 60 fullerene localization and membrane interactions in RAW 264.7 immortalized mouse macrophages

There continues to be a significant increase in the number and complexity of hydrophobic nanomaterials that are engineered for a variety of commercial purposes making human exposure a significant health concern. This study uses a combination of biophysical, biochemical and computational methods to probe potential mechanisms for uptake of C 60 nanoparticles into various compartments of living immune cells. Cultures of RAW 264.7 immortalized murine macrophage were used as a canonical model of immune-competent cells that are likely to provide the first line of defense following inhalation. Modes of entry studied were endocytosis/pinocytosis and passive permeation of cellular membranes. The evidence suggests marginal uptake of C 60 clusters is achieved through endocytosis/pinocytosis, and that passive diffusion into membranes provides a significant source of biologically-available nanomaterial. Compu-tational modeling of both a single molecule and a small cluster of fullerenes predicts that low concentrations of fullerenes enter the membrane individually and produce limited perturbation; however, at higher concentrations the clusters in the membrane causes deformation of the membrane. These findings are bolstered by nuclear magnetic resonance (NMR) of model membranes that reveal defor-mation of the cell membrane upon exposure to high concentrations of fullerenes. The atomistic and NMR models fail to explain escape of the particle out of biological membranes, but are limited to idealized systems that do not completely recapitulate the complexity of cell membranes. Lastly, the surprising contribution of passive modes of cellular entry provides new avenues for toxicological research that go beyond the pharmacological inhibition of bulk transport systems such as pinocytosis.

59 BASIC BIOLOGICAL SCIENCES↗

Critical role of structural order in bipolar redox-active molecules for organic redox flow batteries

Bipolar redox-active molecules (BRMs) have been suggested as a means to address crossover related issues in all-organic redox flow batteries (RFBs). In such species, electron donors (anolytes) and electron acceptors (catholytes) are linked by a chain, and the same chemical composition is used in both anode and cathode compartments to reduce chemical gradients and unbalanced ion transport. The resultant RFBs resemble the aqueous vanadium RFBs, but offer greater design flexibility and potentially more favorable electrochemical and physicochemical properties. Yet the complex trade-offs in these properties have been a complication. Here we developed a fundamental rubric to uncover the likely origins in the performance metrics of these BRMs that are salient for their use in RFBs. Methylene linked phenothiazine and phthalimide moieties were employed as model BRMs and variations in their properties and molecular conformations were evaluated by systematically varying the methylene linker. Our results revealed that even minimalistic changes in the linker length resulted in dramatic oscillations in the solubility and stability. Using crystallography, quantum chemistry, and molecular dynamics, we clarify that the seemingly fluctuating behavior is due to (1) the inter- and intra-molecular charge transfer between the donor and acceptor through bond or/and through space; (2) the formation of distinctive packing/clustering motifs. Both interactions are strongly dependent on the molecular conformation. As these structural factors modify the electronic structure of both electroactive functional groups and do not change monotonically, the structure–property response in BRMs is often complex. Finally, accordingly, these behaviors need to be taken into account in developing BRMs and knowledge of these structural factors will allow the more rational design of BRMs for grid-scale energy storage.

25 ENERGY STORAGE↗

Engineering endosomolytic nanocarriers of diverse morphologies using confined impingement jet mixing

The clinical translation of many biomolecular therapeutics has been hindered by undesirable pharmacokinetic (PK) properties, inadequate membrane permeability, poor endosomal escape and cytosolic delivery, and/or susceptibility to degradation. Overcoming these challenges merits the development of nanoscale drug carriers (nanocarriers) to improve the delivery of therapeutic cargo. Herein, we implement a flash nanoprecipitation (FNP) approach to produce nanocarriers of diverse vesicular morphologies by using various molecular weight PEG-bl-DEAEMA-co-BMA (PEG-DB) polymers. We demonstrated that FNP can produce uniform (PDI < 0.1) particles after 5 impingements, and that by varying the copolymer hydrophilic mass fraction, FNP enables access to a diverse variety of nanoarchitectures including micelles, unilamellar vesicles (polymersomes), and multi-compartment vesicles (MCVs). We synthesized a library of 2 kDa PEG block copolymers, with DEAEMA-co-BMA second block molecular weights of 3, 6, 12, 15, 20, and 30 kDa. All formulations were both pH responsive, endosomolytic, and capable of loading and cytosolically delivering small negatively charged molecules – albeit to different degrees. Using a B16.F10 melanoma model, we showcased the therapeutic potential of a lead FNP formulated PEG-DB nanocarrier, encapsulating the cyclic dinucleotide (CDN) cGAMP to activate the stimulator of interferon genes (STING) pathway in a therapeutically relevant context. Collectively, these data demonstrate that an FNP process can be used to formulate pH-responsive nanocarriers of diverse morphologies using a PEG-DB polymer system. As FNP is an industrially scalable process, these data address the critical translational challenge of producing PEG-DB nanoparticles at scale. Furthermore, the diverse morphologies produced may specialize in the delivery of distinct biomolecular cargos for other therapeutic applications, implicating the therapeutic potential of this platform in an array of disease applications.

36 MATERIALS SCIENCE↗

Enhanced reactivity at the oil–water interface accelerates the synthesis of zymonic acid in microemulsions

Chemical reactions in microscale compartments, such as aerosols and emulsions, can exhibit significantly faster reaction rates relative to macroscale containers. This enhancement in chemistry is often due to the elevated importance of surfaces as reaction vessels are reduced to picoliter volumes. While most studies have focused on the air-water interface of droplets, there are comparably fewer studies of reactions in micron-scale aqueous solutions encapsulated by oil. Here we investigate the condensation reaction of pyruvic acid (PA) to form zymonic acid (ZA) and water. Using microfluidics and optical trapping, chemical kinetics are measured in monodisperse micron-sized emulsion droplets in situ via Raman spectroscopy. Relative to a macroscopic bulk solution, which exhibits little to no reaction over many days, we find efficient production of ZA over the same time period. A kinetic model is developed to elucidate the role of the interface in accelerating the microdroplet reaction kinetics. After quantifying the surface partitioning of PA from interfacial tension measurements, the rate coefficient for the condensation reaction at the oil-water interface is determined to be 1.8 × 10-2 M-1 s-1. This rate coefficient is estimated to be 105 larger than the reaction rate in bulk aqueous solutions. Compared to previous studies of accelerated ZA formation at the air-water interface on nanodroplets, we find that the reaction at the oil-water interface is 20 times more efficient. Despite this difference, the overall ZA formation rate in emulsions is significantly slower than in the same-sized aerosols, which arises from the weaker partitioning of PA to the oil-aqueous relative to air-water interface. These results highlight the interplay between interfacial partitioning and reactivity in accelerating chemistry in microcompartments and provides new insights into how interfacial composition influences condensation reactions.

Wallace, Brandon J↗

Chemical Composition Study of the Rybinsk Reservoir Ecosystem Using NAA

Epithermal neutron activation analysis (ENAA) enabled identification of 31 elements (Na, Mg, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Ni, Zn, As, Se, Br, Sr, Rb, Sb, I, Cs, Ba, La, Ce, Nd, Sm, Eu, Tb, Dy, Tm, Hf, Ta, W) in bottom sediments and bivalve mollusks from different compartments of the man-made lake, the Rybinsk Reservoir (Northern Russia). High concentrations of some heavy metals were observed in both sediments and mollusks in the close vicinity of Cherepovets.

54 ENVIRONMENTAL SCIENCES↗

Nondestructive experimental determination of bimaterial rectangular cantilever spring constants in water

In order to address the issue of spring constant calibration in viscous fluids such as water, a new method is presented that allows for the experimental calibration of bimaterial cantilever spring constants. This method is based on modeling rectangular cantilever beam bending as a function of changing temperature. The temperature change is accomplished by heating water as it flows around the cantilever beams in an enclosed compartment. The optical static method of detection is used to measure the deflection of cantilever at the free end. Experimentally determined results are compared to Sader's method and to the Thermotune method most commonly used in cantilever calibrations. Results indicate that the new bimaterial thermal expansion method is accurate within 15%-20% of the actual cantilever spring constant, which is comparable to other nondestructive calibration techniques.

42 ENGINEERING↗

SPARCLE: Electrostatic Tool for Lunar Dust Control

Successful exploration of most planetary surfaces, with their impact-generated dusty regoliths, will depend on the capabilities to keep surfaces free of the dust which could compromise performance and to collect dust for characterization. Solving the dust problem is essential before we return to the Moon. During the Apollo missions, the discovery was made that regolith fines, or dust, behaved like abrasive velcro, coating surfaces, clogging mechanisms, and making movement progressively more difficult as it was mechanically stirred up during surface operations, and abrading surfaces, including spacesuits, when attempts were made to remove it manually. In addition, some of the astronauts experienced breathing difficulties when exposed to dust that got into the crew compartment. The successful strategy will deal with dust dynamics resulting from interaction between mechanical and electrostatic forces. Here we will describe the surface properties of dust particles, the basis for their behavior, and an electrostatically-based approach and methodology for addressing this issue confirmed by our preliminary results. Our device concept utilizes a focused electron beam to control the electrostatic potential of the surface. A plate of the opposite potential is then used to induce dust migration in the presence of an electrical field. Our goal is a compact device of <5 kg mass and using <5 watts of power to be operational in <5 years with heritage from ionic sweepers for active spacecraft potential control (e.g., on POLAR). Rovers could be fitted with devices that could harness the removal of dust for sampling as part of the extended exploration process on Mercury, Mars, asteroids or outer solar system satellites, as well as the Moon.

79 ASTRONOMY AND ASTROPHYSICS↗

A microcalorimeter for measuring heat effects of electrochemical reactions with submonolayer conversions

We present a microcalorimeter for measuring heat effects during electrochemical reactions with conversions down to a few percent of a monolayer, referenced to the electrode's surface atoms. The design uses a thin pyroelectric polymer foil for temperature measurement at the backside of a thin electrode, similar to the concepts pioneered by the groups of D. A. King and Ch. T. Campbell for UHV adsorption microcalorimetry. To establish intimate thermal contact between electrode and sensor and utmost sensitivity, the free standing sensor and electrode foils are pressed together by air pressure, acting on the electrochemical cell. Pyroelectric temperature sensing is combined with pulsed electrochemistry, where the electrochemical heat is released on a time scale of about 10 ms, which is long enough for thermal equalization of the electrode-sensor assembly but short enough to avoid significant heat loss into electrolyte and cell compartment. As examples heat effects upon Ag deposition and dissolution as well as the electron transfer reaction of [Fe(CN){sub 6}]{sup 4-}/[Fe(CN){sub 6}]{sup 3-} are presented. The latter reaction was also employed for the calibration of the calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface Modification of Material by Irradiation of Low Power Atmospheric Pressure Plasma Jet

Application of a low power atmospheric pressure plasma jet for surface modifications of acrylic, aluminum, and highly crystalline graphite has been carried out experimentally. The plasma jet was generated with batteries-driven high voltage modulator. The power consumed for the plasma generation was estimated to be 0.12 W. The plasma had hydroxyl radicals, which is known as a strong oxider from an observation of optical emission spectrum. After the irradiation of the plasma, the surfaces of acrylic and aluminum became to be hydrophilic from the compartment of contact angle of water on these surfaces. The surface of highly crystalline graphite irradiated by the plasma jet had oxygen-rich functional groups such as C-O, C = O, and O = C-O.

36 MATERIALS SCIENCE↗

A Comparative Study Using Numerical Methods for Surface X Ray Doses with Conventional and Digital Radiology Equipment in Pediatric Radiology

The place of the study is a pediatrics clinic which realizes a great variety of emergency, ambulatory ad hospital examinations. The radiology compartment respects work procedures and a system to ensure the quality of X ray examinations. The results show a constant for the programmator of the digital detector machine for the tension applied to the tube. For the screen-film detector machine the applied tension increases proportionally with the physical development of the child considering the trunk thickness.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fourier transform infrared absorption spectroscopy characterization of gaseous atmospheric pressure plasmas with 2 mm spatial resolution

This paper describes an optical setup built to record Fourier transform infrared (FTIR) absorption spectra in an atmospheric pressure plasma with a spatial resolution of 2 mm. The overall system consisted of three basic parts: (1) optical components located within the FTIR sample compartment, making it possible to define the size of the infrared beam (2 mm Multiplication-Sign 2 mm over a path length of 50 mm) imaged at the site of the plasma by (2) an optical interface positioned between the spectrometer and the plasma reactor. Once through the plasma region, (3) a retro-reflector module, located behind the plasma reactor, redirected the infrared beam coincident to the incident path up to a 45 Degree-Sign beamsplitter to reflect the beam toward a narrow-band mercury-cadmium-telluride detector. The antireflective plasma-coating experiments performed with ammonia and silane demonstrated that it was possible to quantify 42 and 2 ppm of these species in argon, respectively. In the case of ammonia, this was approximately three times less than this gas concentration typically used in plasma coating experiments while the silane limit of quantification was 35 times lower. Moreover, 70% of the incoming infrared radiation was focused within a 2 mm width at the site of the plasma, in reasonable agreement with the expected spatial resolution. The possibility of reaching this spatial resolution thus enabled us to measure the gaseous precursor consumption as a function of their residence time in the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, multichannel, and low noise arbitrary waveform generator

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗