Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPENSATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Towards a beyond 1 GHz solid-state nuclear magnetic resonance: External lock operation in an external current mode for a 500 MHz nuclear magnetic resonance

Achieving a higher magnetic field is important for solid-state nuclear magnetic resonance (NMR). But a conventional low temperature superconducting (LTS) magnet cannot exceed 1 GHz (23.5 T) due to the critical magnetic field. Thus, we started a project to replace the Nb{sub 3}Sn innermost coil of an existing 920 MHz NMR (21.6 T) with a Bi-2223 high temperature superconducting (HTS) innermost coil. Unfortunately, the HTS magnet cannot be operated in persistent current mode; an external dc power supply is required to operate the NMR magnet, causing magnetic field fluctuations. These fluctuations can be stabilized by a field-frequency lock system based on an external NMR detection coil. We demonstrate here such a field-frequency lock system in a 500 MHz LTS NMR magnet operated in an external current mode. The system uses a {sup 7}Li sample in a microcoil as external NMR detection system. The required field compensation is calculated from the frequency of the FID as measured with a frequency counter. The system detects the FID signal, determining the FID frequency, and calculates the required compensation coil current to stabilize the sample magnetic field. The magnetic field was stabilized at 0.05 ppm/3 h for magnetic field fluctuations of around 10 ppm. This method is especially effective for a magnet with large magnetic field fluctuations. The magnetic field of the compensation coil is relatively inhomogeneous in these cases and the inhomogeneity of the compensation coil can be taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transfer in Fe-doped GaN: The role of the donor

Several nitride-based device structures would benefit from the availability of high quality, large-area, freestanding semi-insulating GaN substrates. Due to the intrinsic n-type nature of GaN, however, the incorporation of compensating centers such as Fe is necessary to achieve the high resistivity required. We are using electron paramagnetic resonance (EPR) to explore charge transfer in 450 um thick GaN:Fe plates to understand the basic mechanisms related to compensation so that the material may be optimized for device applications. The results suggest that the simple model based on one shallow donor and a single Fe level is insufficient to describe compensation. Rather, the observation of the neutral donor and Fe3+ indicates that either the two species are spatially segregated or additional compensating and donor defects must be present.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intermixing at the absorber-buffer layer interface in thin-film solar cells: The electronic effects of point defects in Cu(In,Ga)(Se,S){sub 2} and Cu{sub 2}ZnSn(Se,S){sub 4} devices

We investigate point defects in the buffer layers CdS and ZnS that may arise from intermixing with Cu(In,Ga)(S,Se){sub 2} (CIGS) or Cu{sub 2}ZnSn(S,Se){sub 4} (CZTS) absorber layers in thin-film photovoltaics. Using hybrid functional calculations, we characterize the electrical and optical behavior of Cu, In, Ga, Se, Sn, Zn, Na, and K impurities in the buffer. We find that In and Ga substituted on the cation site act as shallow donors in CdS and tend to enhance the prevailing n-type conductivity at the interface facilitated by Cd incorporation in CIGS, whereas they are deep donors in ZnS and will be less effective dopants. Substitutional In and Ga can favorably form complexes with cation vacancies (A-centers) which may contribute to the “red kink” effect observed in some CIGS-based devices. For CZTS absorbers, we find that Zn and Sn defects substituting on the buffer cation site are electrically inactive in n-type buffers and will not supplement the donor doping at the interface as in CIGS/CdS or ZnS devices. Sn may also preferentially incorporate on the S site as a deep acceptor in n-type ZnS, which suggests possible concerns with absorber-related interfacial compensation in CZTS devices with ZnS-derived buffers. Cu, Na, and K impurities are found to all have the same qualitative behavior, most favorably acting as compensating acceptors when substituting on the cation site. Our results suggest one beneficial role of K and Na incorporation in CIGS or CZTS devices is the partial passivation of vacancy-related centers in CdS and ZnS buffers, rendering them less effective interfacial hole traps and recombination centers.

36 MATERIALS SCIENCE↗

Effect of crystal quality on performance of spin-polarized photocathode

GaAs/GaAsP strain-compensated superlattices (SLs) with thickness up to 90-pair were fabricated. Transmission electron microscopy revealed the SLs are of high crystal quality and the introduced strain in SLs layers are fixed in the whole SL layers. With increasing SL pair number, the strain-compensated SLs show a less depolarization than the conventional strained SLs. In spite of the high crystal quality, the strain-compensated SLs also remain slightly depolarized with increasing SL pairs and the decrease in spin-polarization contributes to the spin relaxation time. 24-pair of GaAs/GaAsP strain-compensated SL demonstrates a maximum spin-polarization of 92% with a high quantum efficiency of 1.6%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The coupled nonlinear dynamics of a lift system

Coupled lateral and longitudinal vibrations of suspension and compensating ropes in a high-rise lift system are often induced by the building motions due to wind or seismic excitations. When the frequencies of the building become near the natural frequencies of the ropes, large resonance motions of the system may result. This leads to adverse coupled dynamic phenomena involving nonplanar motions of the ropes, impact loads between the ropes and the shaft walls, as well as vertical vibrations of the car, counterweight and compensating sheave. Such an adverse dynamic behaviour of the system endangers the safety of the installation. This paper presents two mathematical models describing the nonlinear responses of a suspension/ compensating rope system coupled with the elevator car / compensating sheave motions. The models accommodate the nonlinear couplings between the lateral and longitudinal modes, with and without longitudinal inertia of the ropes. The partial differential nonlinear equations of motion are derived using Hamilton Principle. Then, the Galerkin method is used to discretise the equations of motion and to develop a nonlinear ordinary differential equation model. Approximate numerical solutions are determined and the behaviour of the system is analysed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Roughness effects in uncompensated antiferromagnets

Monte Carlo simulations show that roughness in uncompensated antiferromagnets decreases not just the surface magnetization but also the net magnetization and particularly strongly affects the temperature dependence. In films with step-type roughness, each step creates a new compensation front that decreases the global net magnetization. The saturation magnetization decreases non-monotonically with increasing roughness and does not scale with the surface area. Roughness in the form of surface vacancies changes the temperature-dependence of the magnetization; when only one surface has vacancies, the saturation magnetization will decrease linearly with surface occupancy, whereas when both surfaces have vacancies, the magnetization is negative and exhibits a compensation point at finite temperature, which can be tuned by controlling the occupancy. Roughness also affects the spin-texture of the surfaces due to long-range dipolar interactions and generates non-collinear spin configurations that could be used in devices to produce locally modified exchange bias. These results explain the strongly reduced magnetization found in magnetometry experiments and furthers our understanding of the temperature-dependence of exchange bias.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First-principles study of defects and doping limits in CaO

Calcium oxide (CaO) is a promising host for quantum defects because of its ultrawide bandgap and potential for long spin coherence times. Using hybrid functional calculations, we investigate the intrinsic point defects and how they limit Fermi-level positions and doping in CaO. We find calcium and oxygen vacancies to be the most common intrinsic defects, acting as compensating acceptors and donors, respectively. Oxygen interstitials are also prevailing under O-rich conditions and act as compensating donors. Due to compensation by these defects, O-poor conditions are required to dope CaO n-type, while O-rich conditions are required for p-type doping. We find that, at room temperature, intrinsic CaO can only achieve Fermi-level positions between 1.76 eV above the valence-band maximum (VBM) and 1.73 eV below the conduction-band minimum (CBM). If suitable shallow dopants are found, the allowed range of Fermi levels would increase to between VBM + 0.53 eV and CBM − 0.27 eV and is set by the compensating intrinsic defects. Additionally, we study hydrogen impurities, and show that hydrogen will not only limit p-type doping but can also act as shallow donor when substituting oxygen (HO defects).

Physics↗

Infrared optical absorption in low-spin Fe 2+ -doped SrTiO 3

Band gap engineering in SrTiO3 and related titanate perovskites has long been explored due to the intriguing properties of the materials for photocatalysis and photovoltaic applications. A popular approach in the materials chemistry community is to substitutionally dope aliovalent transition metal ions onto the B site in the lattice to alter the valence band. However, in such a scheme there is limited control over the dopant valence, and compensating defects often form. Here we demonstrate a novel technique to controllably synthesize Fe2+- and Fe3+-doped SrTiO3 thin films without formation of compensating defects by co-doping with La3+ ions on the A site. We stabilize Fe2+-doped films by doping with two La ions for every Fe dopant, and find that the Fe ions exhibit a low-spin electronic configuration, producing optical transitions in the near infrared regime and degenerate doping. The novel electronic states observed here offer a new avenue for band gap engineering in perovskites for photocatalytic and photovoltaic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable competing magnetic anisotropies and spin reconfigurations in ferrimagnetic Fe 100– x Gd x alloy films

Here, we report a comprehensive study of the temperature evolution of in-plane (IP) and out-of-plane (OOP) effective magnetic anisotropies in compensated ferrimagnetic Fe 100– x Gd x alloy films by employing direct current magnetometry and radiofrequency (RF) transverse susceptibility (TS) measurements. We suggest that our Fe 100– x Gd x system is chemically inhomogeneous and phase segregates into Fe- and Gd-enriched regions. Our IP and OOP magnetometry results indicate that the system undergoes a temperature-driven transformation from an IP-spin-configuration-dominated state to an OOP-spin-configuration-dominated state below a certain temperature (spin reorientation temperature). A two-step reversal behavior emerges in the OOP $\textit{M(H)}$ loop near compensation, which we attribute to the sequential magnetization reversals of Fe- and Gd-enriched domains. Field-induced spin-flop transitions were also observed near the compensation. Our RF TS measurements indicate that the effective magnetic anisotropy for the OOP configuration dominates over that for the IP configuration below a certain spin reorientation temperature. Both IP and OOP anisotropy fields determined from our TS measurement exhibit a minimum around the compensation temperature, which has been explained in the framework of the Stoner-Wohlfarth model.

36 MATERIALS SCIENCE↗

Enhanced Rotary Transformer-Based Field Excitation System for Wound Rotor Synchronous Motor

Wound rotor synchronous motors are being increasingly considered for electric vehicle traction applications. In this regard, the rotary transformer-based field excitation system is considered one of the most viable option for the rotor winding excitation. For such applications, key performance indicators for the rotary transformer-based field excitation system include: maximum speed, power transfer capability, size and weight, manufacturing cost and ease of control. These indicators on the other hand are affected by design choices such as mechanical and magnetic air-gap lengths, use of ferrites in the rotor of the rotary transformer and reactive power compensation. This paper evaluates the performance of the field excitation system based on two different designs of the rotary transformer: a conventional design and a proposed design. Particularly, the effect of various compensation types on the power transfer capability of the two design types is evaluated. It is shown that unlike the conventional design, the proposed design can take advantage of resonant compensation circuits both to enhance its power transfer capability and to ease the control. Taking the same space constraints, winding window areas, and number of turns for the two types of design, the condition necessary for compensation to enhance the performance of the field excitation system is established.

Haruna, Josiah↗

Stabilization mechanisms of LaFeO3 (010) surfaces determined with first principles calculations

Density functional theory is used to determine the stabilization mechanisms of LaFeO3 (010) surfaces over a range of surface oxygen stoichiometries. For the stoichiometric LaO surface, and for reduced surface terminations, charge redistribution is needed for stabilization that results in an electron-rich surface. In contrast, in the case of the stoichiometric FeO2 surface and oxidized surface terminations with low-coordinated oxygen atoms, a hole-rich surface is needed for stabilization. The calculations further predict that low coordinated oxygen atoms are more stable on LaO-type surface terminations than on FeO2-type surface terminations due to relatively strong electron transfer. In addition to these electronic effects, atomic relaxation is found to be an important contributor to charge compensation, with LaO-type surface terminations exhibiting larger atomic relaxations than FeO2-type surface terminations. As a result, there is a significant contribution from the sub-layers to charge compensation in LaO-type surface terminations.

density functional theory↗

On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom

For routine pretreatment verification of innovative treatment techniques such as (intensity modulated) dynamic arc therapy and helical TomoTherapy, an on-line and reliable method would be highly desirable. The present solution proposed by TomoTherapy, Inc. (Madison, WI) relies on film dosimetry in combination with up to two simultaneous ion chamber point dose measurements. A new method is proposed using a 2D ion chamber array (Seven29, PTW, Freiburg, Germany) inserted in a dedicated octagonal phantom, called Octavius. The octagonal shape allows easy positioning for measurements in multiple planes. The directional dependence of the response of the detector was primarily investigated on a dual energy (6 and 18 MV) Clinac 21EX (Varian Medical Systems, Palo Alto, CA) as no fixed angle incidences can be calculated in the Hi-Art TPS of TomoTherapy. The array was irradiated from different gantry angles and with different arc deliveries, and the dose distributions at the level of the detector were calculated with the AAA (Analytical Anisotropic Algorithm) photon dose calculation algorithm implemented in Eclipse (Varian). For validation on the 6 MV TomoTherapy unit, rotational treatments were generated, and dose distributions were calculated with the Hi-Art TPS. Multiple cylindrical ion chamber measurements were used to cross-check the dose calculation and dose delivery in Octavius in the absence of the 2D array. To compensate for the directional dependence of the 2D array, additional prototypes of Octavius were manufactured with built-in cylindrically symmetric compensation cavities. When using the Octavius phantom with a 2 cm compensation cavity, measurements with an accuracy comparable to that of single ion chambers can be achieved. The complete Octavius solution for quality assurance of rotational treatments consists of: The 2D array, two octagonal phantoms (with and without compensation layer), an insert for nine cylindrical ion chambers, and a set of inserts of various tissue equivalent materials of different densities. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments. Quality control of TomoTherapy patients was reduced to a total of {approx}25 min per patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams

Purpose: Neutron exposure is of concern in proton therapy, and varies with beam delivery technique, nozzle design, and treatment conditions. Uniform scanning is an emerging treatment technique in proton therapy, but neutron exposure for this technique has not been fully studied. The purpose of this study is to investigate the neutron dose equivalent per therapeutic dose, H/D, under various treatment conditions for uniform scanning beams employed at our proton therapy center. Methods: Using a wide energy neutron dose equivalent detector (SWENDI-II, ThermoScientific, MA), the authors measured H/D at 50 cm lateral to the isocenter as a function of proton range, modulation width, beam scanning area, collimated field size, and snout position. They also studied the influence of other factors on neutron dose equivalent, such as aperture material, the presence of a compensator, and measurement locations. They measured H/D for various treatment sites using patient-specific treatment parameters. Finally, they compared H/D values for various beam delivery techniques at various facilities under similar conditions. Results: H/D increased rapidly with proton range and modulation width, varying from about 0.2 mSv/Gy for a 5 cm range and 2 cm modulation width beam to 2.7 mSv/Gy for a 30 cm range and 30 cm modulation width beam when 18 Multiplication-Sign 18 cm{sup 2} uniform scanning beams were used. H/D increased linearly with the beam scanning area, and decreased slowly with aperture size and snout retraction. The presence of a compensator reduced the H/D slightly compared with that without a compensator present. Aperture material and compensator material also have an influence on neutron dose equivalent, but the influence is relatively small. H/D varied from about 0.5 mSv/Gy for a brain tumor treatment to about 3.5 mSv/Gy for a pelvic case. Conclusions: This study presents H/D as a function of various treatment parameters for uniform scanning proton beams. For similar treatment conditions, the H/D value per uncollimated beam size for uniform scanning beams was slightly lower than that from a passive scattering beam and higher than that from a pencil beam scanning beam, within a factor of 2. Minimizing beam scanning area could effectively reduce neutron dose equivalent for uniform scanning beams, down to the level close to pencil beam scanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of lateral penumbra for uniform scanning proton beams under various beam delivery conditions and comparison to the XiO treatment planning system

Purpose: The main purposes of this study were to (1) investigate the dependency of lateral penumbra (80%–20% distance) of uniform scanning proton beams on various factors such as air gap, proton range, modulation width, compensator thickness, and depth, and (2) compare the lateral penumbra calculated by a treatment planning system (TPS) with measurements.Methods: First, lateral penumbra was measured using solid–water phantom and radiographic films for (a) air gap, ranged from 0 to 35 cm, (b) proton range, ranged from 8 to 30 cm, (c) modulation, ranged from 2 to 10 cm, (d) compensator thickness, ranged from 0 to 20 cm, and (e) depth, ranged from 7 to 15 cm. Second, dose calculations were computed in a virtual water phantom using the XiO TPS with pencil beam algorithm for identical beam conditions and geometrical configurations that were used for the measurements. The calculated lateral penumbra was then compared with the measured one for both the horizontal and vertical scanning magnets of our uniform scanning proton beam delivery system.Results: The results in the current study showed that the lateral penumbra of horizontal scanning magnet was larger (up to 1.4 mm for measurement and up to 1.0 mm for TPS) compared to that of vertical scanning magnet. Both the TPS and measurements showed an almost linear increase in lateral penumbra with increasing air gap as it produced the greatest effect on lateral penumbra. Lateral penumbra was dependent on the depth and proton range. Specifically, the width of lateral penumbra was found to be always lower at shallower depth than at deeper depth within the spread out Bragg peak (SOBP) region. The lateral penumbra results were less sensitive to the variation in the thickness of compensator, whereas lateral penumbra was independent of modulation. Overall, the comparison between the results of TPS with that of measurements indicates a good agreement for lateral penumbra, with TPS predicting higher values compared to measurements.Conclusions: Lateral penumbra of uniform scanning proton beams depends on air gap, proton range, compensator thickness, and depth, whereas lateral penumbra is not dependent on modulation. The XiO TPS typically overpredicted lateral penumbra compared to measurements, within 1 mm for most cases, but the difference could be up to 2.5 mm at a deep depth and large air gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-590: An Activation Study of Materials and Devices Present in a Proton Treatment Room

Purpose: The use of protons for radiation therapy is growing rapidly. One consequence of protons interacting with different media is activation. These nuclear reactions induced by the protons, scattered neutrons, and gamma rays, activate different materials encountered, particularly by the therapists. The purpose of this study was to examine the derived nuclides from the activation, and also the decay rate. Methods: The study was conducted in our proton therapy facility. Protons are derived from a synchrocyclotron and pass through field shipping systems, apertures, and range compensators to define the beam within the patient.Included materials of concerns measured; the patient support couch, sheet rock in the wall, solid plastics used for quality assurance and dosimetry, and the passive scattering system itself, which includes brass apertures, and Lucite or blue wax compensators. All devices were studied post irradiation using gamma spectroscopy to determine the nuclides, and a sodium iodine scintillation detector to measure decay, particularly when the dose rate fell to background levels. Results: We have also determined from the measurements we will maintain brass apertures for three months before sending them for scrap. Some of the radionuclides arrived from these measurements included Na-22 for the blue wax compensator, C1-34m for the sheetrock, and Sc-44 and Co-60 for the brass apertures. We found compensators made out of Lucite or wax decayed to background in 2 hours. The patient support couch decayed to background in approximately 40 minutes, and sheet rock decayed in 80 minutes. In terms of the aperture layers, the most proximal aperture slab had much higher activity than the distal slab. Also the proximal sides of the slabs were much more activate than the distal. Conclusion: We have given proper instruction to therapists performing quality assurance in terms of the handled plastics, and to handle apertures rapidly as possible.

07 ISOTOPE AND RADIATION SOURCES↗

Development and evaluation of a method of calibrating medical displays based on fixed adaptation

Purpose: The purpose of this work was to develop and evaluate a new method for calibration of medical displays that includes the effect of fixed adaptation and by using equipment and luminance levels typical for a modern radiology department. Methods: Low contrast sinusoidal test patterns were derived at nine luminance levels from 2 to 600 cd/m{sup 2} and used in a two alternative forced choice observer study, where the adaptation level was fixed at the logarithmic average of 35 cd/m{sup 2}. The contrast sensitivity at each luminance level was derived by establishing a linear relationship between the ten pattern contrast levels used at every luminance level and a detectability index (d′) calculated from the fraction of correct responses. A Gaussian function was fitted to the data and normalized to the adaptation level. The corresponding equation was used in a display calibration method that included the grayscale standard display function (GSDF) but compensated for fixed adaptation. In the evaluation study, the contrast of circular objects with a fixed pixel contrast was displayed using both calibration methods and was rated on a five-grade scale. Results were calculated using a visual grading characteristics method. Error estimations in both observer studies were derived using a bootstrap method. Results: The contrast sensitivities for the darkest and brightest patterns compared to the contrast sensitivity at the adaptation luminance were 37% and 56%, respectively. The obtained Gaussian fit corresponded well with similar studies. The evaluation study showed a higher degree of equally distributed contrast throughout the luminance range with the calibration method compensated for fixed adaptation than for the GSDF. The two lowest scores for the GSDF were obtained for the darkest and brightest patterns. These scores were significantly lower than the lowest score obtained for the compensated GSDF. For the GSDF, the scores for all luminance levels were statistically separated from the average value; three were lower and two were higher. For the compensated GSDF, three of the scores could not be separated from the average value. Conclusions: An observer study using clinically relevant displays and luminance settings has demonstrated that the calibration of displays according to the GSDF causes the perceived contrast to be unevenly distributed when using displays with a high luminance range. As the luminance range increases, the perceived contrast in the dark and bright regions will be significantly lower than the perceived contrast in the middle of the luminance range. A new calibration method that includes the effect of fixed adaptation was developed and evaluated in an observer study and was found to distribute the contrast of the display more evenly throughout the grayscale than the GSDF.

60 APPLIED LIFE SCIENCES↗