Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

MO-C-17A-05: A Three-Dimensional Head-And-Neck Phantom for Validation of Kilovoltage- and Megavoltage-Based Deformable Image Registration

Purpose: To develop a three-dimensional (3D) deformable head-and-neck (H and N) phantom with realistic tissue contrast for both kilovoltage and megavoltage computed tomography and use it to objectively evaluate deformable image registration (DIR) algorithms. Methods: The phantom represents H and N patient anatomy. It is constructed from thermoplastic, which becomes pliable in boiling water, and hardened epoxy resin. Using a system of additives, the Hounsfield unit (HU) values of these materials were tuned to mimic anatomy for both kilovoltage (kV) and megavoltage (MV) imaging. The phantom opened along a sagittal midsection to reveal nonradiopaque markers, which were used to characterize the phantom deformation. The deformed and undeformed phantom was scanned with kV and MV computed tomography. Additionally, a calibration curve was created to change the HUs of the MV scans to be similar to kV HUs, (MC). The extracted ground-truth deformation was then compared to the results of two commercially available DIR algorithms, from Velocity Medical Solutions and MIM Software. Results: The phantom produced a 3D deformation, representing neck flexion, with a magnitude of up to 8 mm and was able represent tissue HUs for both kV and MV imaging modalities. The two tested deformation algorithms yielded vastly different results. For kV-kV registration, MIM made the lowest mean error, and Velocity made the lowest maximum error. For MV-MV, kV-MV, and kV-MC Velocity produced both the lowest mean and lowest maximum errors. Conclusion: The application of DIR across different imaging modalities is particularly difficult, due to differences in tissue HUs and the presence of imaging artifacts. For this reason, DIR algorithms must be validated specifically for this purpose. The developed H and N phantom is an effective tool for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Numerical Simulation of Pore-Scale Flow in a Bead Pack: Comparison with Magnetic Resonance Imaging Observations

A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental error in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods.

computational fluid dynamics↗

Fully quantum algorithm for mesoscale fluid simulations with application to partial differential equations

Fluid flow simulations marshal our most powerful computational resources. In many cases, even this is not enough. Quantum computers provide an opportunity to speed up traditional algorithms for flow simulations. We show that lattice-based mesoscale numerical methods can be executed as efficient quantum algorithms due to their statistical features. This approach revises a quantum algorithm for lattice gas automata to reduce classical computations and state preparation at every time step. For this, the algorithm approximates the qubit relative phases and subtracts them at the end of each time step. Phases are evaluated using the iterative phase estimation algorithm and subtracted using single-qubit rotation phase gates. Further, this method optimizes the quantum resource required and makes it more appropriate for near-term quantum hardware. We also demonstrate how the checkerboard deficiency that the D1Q2 scheme presents can be resolved using the D1Q3 scheme. The algorithm is validated by simulating two canonical partial differential equations: the diffusion and Burgers' equations on different quantum simulators. We find good agreement between quantum simulations and classical solutions for the presented algorithm.

97 MATHEMATICS AND COMPUTING↗

Measurement of regional compliance using 4DCT images for assessment of radiation treatment

Purpose: Radiation-induced damage, such as inflammation and fibrosis, can compromise ventilation capability of local functional units (alveoli) of the lung. Ventilation function as measured with ventilation images, however, is often complicated by the underlying mechanical variations. The purpose of this study is to present a 4DCT-based method to measure the regional ventilation capability, namely, regional compliance, for the evaluation of radiation-induced lung damage. Methods: Six 4DCT images were investigated in this study: One previously used in the generation of a POPI model and the other five acquired at Henry Ford Health System. A tetrahedral geometrical model was created and scaled to encompass each of the 4DCT image domains. Image registrations were performed on each of the 4DCT images using a multiresolution Demons algorithm. The images at the end of exhalation were selected as a reference. Images at other exhalation phases were registered to the reference phase. For the POPI-modeled patient, each of these registration instances was validated using 40 landmarks. The displacement vector fields (DVFs) were used first to calculate the volumetric variation of each tetrahedron, which represents the change in the air volume. The calculated results were interpolated to generate 3D ventilation images. With the computed DVF, a finite element method (FEM) framework was developed to compute the stress images of the lung tissue. The regional compliance was then defined as the ratio of the ventilation and stress values and was calculated for each phase. Based on iterative FEM simulations, the potential range of the mechanical parameters for the lung was determined by comparing the model-computed average stress to the clinical reference value of airway pressure. The effect of the parameter variations on the computed stress distributions was estimated using Pearson correlation coefficients. Results: For the POPI-modeled patient, five exhalation phases from the start to the end of exhalation were denoted by P{sub i}, i=1,...,5, respectively. The average lung volume variation relative to the reference phase (P{sub 5}) was reduced from 18% at P{sub 1} to 4.8% at P{sub 4}. The average stress at phase P{sub i} was 1.42, 1.34, 0.74, and 0.28 kPa, and the average regional compliance was 0.19, 0.20, 0.20, and 0.24 for i=1,...,4, respectively. For the other five patients, their average R{sub v} value at the end-inhalation phase was 21.1%, 19.6%, 22.4%, 22.5%, and 18.8%, respectively, and the regional compliance averaged over all six patients is 0.2. For elasticity parameters chosen from the potential parameter range, the resultant stress distributions were found to be similar to each other with Pearson correlation coefficients greater than 0.81. Conclusions: A 4DCT-based mechanical model has been developed to calculate the ventilation and stress images of the lung. The resultant regional compliance represents the lung's elasticity property and is potentially useful in correlating regions of lung damage with radiation dose following a course of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Validation of the U.S. NRC NGNP evaluation model with the HTTR

The High Temperature Test Reactor (HTTR) was modeled with TRITON/PARCS. Traditional light water reactor (LWR) homogenization methods rely on the short mean free paths of neutrons in LWR. In gas-cooled, graphite-moderated reactors like the HTTR neutrons have much longer mean free paths and penetrate further into neighboring assemblies than in LWRs. Because of this, conventional lattice calculations with a single assembly may not be valid. In addition to difficulties caused by the longer mean free paths, the HTTR presents unique axial and radial heterogeneities that require additional modifications to the single assembly homogenization method. To handle these challenges, the homogenization domain is decreased while the computational domain is increased. Instead of homogenizing a single hexagonal fuel assembly, the assembly is split into six triangles on the radial plane and five blocks axially in order to account for the placement of burnable poisons. Furthermore, the radial domain is increased beyond a single fuel assembly to account for spectrum effects from neighboring fuel, reflector, and control rod assemblies. A series of five two-dimensional cases, each closer to the full core, were calculated to evaluate the effectiveness of the homogenization method and cross-sections. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gate-based quantum computing for protein design

Protein design is a technique to engineer proteins by permuting amino acids in the sequence to obtain novel functionalities. However, exploring all possible combinations of amino acids is generally impossible due to the exponential growth of possibilities with the number of designable sites. The present work introduces circuits implementing a pure quantum approach, Grover’s algorithm, to solve protein design problems. Our algorithms can adjust to implement any custom pair-wise energy tables and protein structure models. Moreover, the algorithm’s oracle is designed to consist of only adder functions. Quantum computer simulators validate the practicality of our circuits, containing up to 234 qubits. However, a smaller circuit is implemented on real quantum devices. Our results show that using iterations, the circuits find the correct results among all N possibilities, providing the expected quadratic speed up of Grover’s algorithm over classical methods (i.e.,).

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-557: Monte Carlo Modeling of Philips RT-250 Orthovoltage Unit for Beam Spectrum Modulation

Purpose: To develop and validate a Monte Carlo (MC) model of a Phillips RT-250 orthovoltage unit to test various beam spectrum modulation strategies for in vitro/vivo studies. A model of this type would enable the production of unconventional beams from a typical orthovoltage unit for novel therapeutic applications such as gold nanoparticle-aided radiotherapy. Methods: The MCNP5 code system was used to create a MC model of the head of RT-250 and a 30 × 30 × 30 cm{sup 3} water phantom. For the x-ray machine head, the current model includes the vacuum region, beryllium window, collimators, inherent filters and exterior steel housing. For increased computational efficiency, the primary x-ray spectrum from the target was calculated from a well-validated analytical software package. Calculated percentage-depth-dose (PDD) values and photon spectra were validated against experimental data from film and Compton-scatter spectrum measurements. Results: The model was validated for three common settings of the machine namely, 250 kVp (0.25 mm Cu), 125 kVp (2 mm Al), and 75 kVp (2 mm Al). The MC results for the PDD curves were compared with film measurements and showed good agreement for all depths with a maximum difference of 4 % around dmax and under 2.5 % for all other depths. The primary photon spectra were also measured and compared with the MC results showing reasonable agreement between the two, validating the input spectra and the final spectra as predicted by the current MC model. Conclusion: The current MC model accurately predicted the dosimetric and spectral characteristics of each beam from the RT-250 orthovoltage unit, demonstrating its applicability and reliability for beam spectrum modulation tasks. It accomplished this without the need to model the bremsstrahlung xray production from the target, while significantly improved on computational efficiency by at least two orders of magnitude. Supported by DOD/PCRP grant W81XWH-12-1-0198.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully discrete schemes for monotone optimal control problems

In this article, we study an infinite horizon optimal control problem with monotone controls. We analyze the associated Hamilton–Jacobi–Bellman (HJB) variational inequality which characterizes the value function and consider the totally discretized problem using Lagrange elements to approximate the state space Ω. The convergence orders of these approximations are proved, which are in general (h+(k/(√h))){sup γ} where γ is the Hölder constant of the value function u, h and k are the time and space discretization parameters, respectively. A special election of the relations between h and k allows to obtain a convergence of order k{sup (2/3)γ}, which is valid without semiconcavity hypotheses over the problem’s data.

97 MATHEMATICS AND COMPUTING↗

Theoretical analysis on the measurement errors of local 2D DIC: Part I temporal and spatial uncertainty quantification of displacement measurements

This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.

2D-DIC↗

EMPHASIS™/Nevada Unstructured FEM Implementaiton Version 2.1.3. Description, verification, and validation

EMPHASIS™/NEVADA is the SIERRA/NEVADA toolkit implementation of portions of the EMPHASIS TM code suite. The purpose of the toolkit implementation is to facilitate coupling to other physics drivers such as radiation transport as well as to better manage code design, implementation, complexity, and important verification and validation processes. This document describes the theory and implementation of the unstructured finite- element method solver, associated algorithms, and selected verification and validation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Viewfactor and Raytracing for AgriPV Modeling

View factor models are used in due diligence software to calculate rear irradiance for bifacial modules. An intermediate step in this calculation is the irradiance at the ground level, which can be leveraged for evaluating the Photo Active Radiation available for crops in Agrivoltaic setups. This paper presents the metrics and modifications to the model for ground irradiance study with the view factor approach, compares it to the raytracing method, and validates it with field measurements of ground irradiance. It is found that for the clearances, row-to-row setups, and tilts studied, the view factor method matches with raytracing results within 2% MBD. The comparison is performed for the nine most common agriPV configurations using high-performance computing and the NSRDB database for the whole US, with results and data made available open-source on the InSPIRE AgriPV website.

AgriPV↗

Statistically Rigorous Uncertainty Quantification for Physical Parameter Model Calibration with Functional Output

In experiments conducted on the Z-machine at Sandia National Laboratories, dynamic material properties cannot be analyzed using traditional analytic methods, necessitating solving an inverse problem. Bayesian model calibration is a statistical framework for solving an inverse problem to estimate parameters input into a computational model in the presence of multiple uncertainties. Disentangling input parameter uncertainty and model misspecification is often poorly identified problem. When using computational models for physical parameter estimation, the issue of parameter identifiability must be carefully considered to obtain accurate and precise estimates of physical parameters. Additionally, in dynamic material properties applications, the experimental output is a function, velocity over time. While we can sample an arbitrarily large number of points from the measured velocity, these curves only contain a finite amount of information about the calibration parameters. In this report, we propose modifications to the Bayesian model calibration framework to simplify and improve the estimation of physical parameters with functional outputs. Specifically, we propose scaling the likelihood function by an effective sample size rather than modeling the discrepancy function; and modularizing input nuisance parameters with weakly identified parameters. We evaluate the performance of these proposed methods using a statistical simulation study and then apply these methods to estimate parameters of the tantalum equation of state. We conclude that these proposed methods can provide simple, fast, and statistically valid alternatives to the full Bayesian model calibration procedure; and that these methods can be used to estimate parameters of the equation of state for tantalum.

97 MATHEMATICS AND COMPUTING↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Online Convex Optimization of Programmable Quantum Computers to Simulate Time-Varying Quantum Channels

Simulating quantum channels is a fundamental primitive in quantum computing, since quantum channels define general (trace-preserving) quantum operations. An arbitrary quantum channel cannot be exactly simulated using a finite-dimensional programmable quantum processor, making it important to develop optimal approximate simulation techniques. In this paper, we study the challenging setting in which the channel to be simulated varies adversarially with time. We propose the use of matrix exponentiated gradient descent (MEGD), an online convex optimization method, and analytically show that it achieves a sublinear regret in time. Through experiments, we validate the main results for time-varying dephasing channels using a programmable generalized teleportation processor.

97 MATHEMATICS AND COMPUTING↗

An efficient hybrid technique in RCS predictions of complex targets at high frequencies

Most computer codes in Radar Cross Section (RCS) prediction use Physical Optics (PO) and Physical theory of Diffraction (PTD) combined with Geometrical Optics (GO) and Geometrical Theory of Diffraction (GTD). The latter approaches are computationally cheaper and much more accurate for curved surfaces, but not applicable for the computation of the RCS of all surfaces of a complex object due to the presence of caustic problems in the analysis of concave surfaces or flat surfaces in the far field. The main contribution of this paper is the development of a hybrid method based on a new combination of two asymptotic techniques: GTD and PO, considering the advantages and avoiding the disadvantages of each of them. A very efficient and accurate method to analyze the RCS of complex structures at high frequencies is obtained with the new combination. The proposed new method has been validated comparing RCS results obtained for some simple cases using the proposed approach and RCS using the rigorous technique of Method of Moments (MoM). Some complex cases have been examined at high frequencies contrasting the results with PO. This study shows the accuracy and the efficiency of the hybrid method and its suitability for the computation of the RCS at really large and complex targets at high frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systems biology and biomarker discovery

Medical practitioners have always relied on surrogate markers of inaccessible biological processes to make their diagnosis, whether it was the pallor of shock, the flush of inflammation, or the jaundice of liver failure. Obviously, the current implementation of biomarkers for disease is far more sophisticated, relying on highly reproducible, quantitative measurements of molecules that are often mechanistically associated with the disease in question, as in glycated hemoglobin for the diagnosis of diabetes [1] or the presence of cardiac troponins in the blood for confirmation of myocardial infarcts [2]. In cancer, where the initial symptoms are often subtle and the consequences of delayed diagnosis often drastic for disease management, the impetus to discover readily accessible, reliable, and accurate biomarkers for early detection is compelling. Yet despite years of intense activity, the stable of clinically validated, cost-effective biomarkers for early detection of cancer is pathetically small and still dominated by a handful of markers (CA-125, CEA, PSA) first discovered decades ago. It is time, one could argue, for a fresh approach to the discovery and validation of disease biomarkers, one that takes full advantage of the revolution in genomic technologies and in the development of computational tools for the analysis of large complex datasets. This issue of Disease Markers is dedicated to one such new approach, loosely termed the 'Systems Biology of Biomarkers'. What sets the Systems Biology approach apart from other, more traditional approaches, is both the types of data used, and the tools used for data analysis - and both reflect the revolution in high throughput analytical methods and high throughput computing that has characterized the start of the twenty first century.

59 BASIC BIOLOGICAL SCIENCES↗

Activation Calculation for the Dismantling and Decommissioning of a Light Water Reactor Using MCNP{sup TM} with ADVANTG and ORIGEN-S

The boiling water reactor (BWR) Philippsburg 1 (KKP1) and the pressurized water reactor (PWR) Neckarwestheim 1 (GKN I), with a thermal power of 2575 MW{sub th} resp. 2497 MW{sub th}, were shut down and entered directly the post-operational phase which is covered by the operating license held by the nuclear power plant owner. The decommissioning of a nuclear power plant (NPP) which is licensed under chap. 7 of the German Atomic Energy Act, following the post-operational phase requires a comprehensive licensing procedure including in particular radiation protection aspects and possible impacts to the environment. Decommissioning requires a decommissioning license. This will include essential changes in requirements for the systems and components and will mainly lead to the immediate dismantling of the nuclear power plant which is now the only permitted decommissioning strategy in Germany. In this context, neutron activation calculations for the structural components of KKP1 and GKN I have to be carried out to predict occurring activities and to estimate future costs for conditioning and packaging. To avoid an overestimation of the radioactive inventory and to calculate the expenses for decommissioning as accurate as possible, modern state-of-the-art Monte-Carlo-Techniques (MCNP6) combined with automated variance reduction tools (ADAVANTG) are used and are coupled with the activation and decay module ORIGEN-S. This paper presents the calculation procedure and the obtained results with a validation by measured activations and gamma dose rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗