Search NASA⌕ Search

SEARCH · Search NASA

Results for “Configuration Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Advanced human-machine interface for collaborative building control

A system for collaborative energy management and control in a building, including an energy management controller, one or more occupant HMIs that supports two-way communication between building occupants and a facility manager, and between building occupants and the energy management controller, and a facility manager HMI that supports two-way communication between the facility manager and the building occupants, and between the facility manager and the energy management controller, in which the occupant HMI allows building occupants to provide temperature preferences to the facility manager and the energy management controller, and the facility manager HMI allows the facility manager to configure an energy policy for the building as a set of rules and to view occupants' aggregated temperature preferences, and the energy management controller determines an optimum temperature range that resolves conflicting occupant temperature preferences and occupant temperature preferences that conflict with the facility manager's energy policy for the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based data center cooling controls comparative co-design

This article presents a comparative simulation-based control logic design process. It uses the Control Description Language (CDL) and the ASHRAE Guideline 36 high-performing building control sequences with the Modelica Buildings Library (MBL) to demonstrate a comparative analysis of two control designs for a data center chilled water plant. Details include a description of the closed-loop plant and control design methodology, including sizing and parameterization, base and alternative (Guideline 36) control logic with software implementation structure, and outline of the simulation experimentation process. The selected control designs are paired with comparable chilled water plant configurations. The models include a chiller, a water-side economizer, and an evaporative cooling tower. The plant provides cooling at 27ºC zone supply air temperature to a data center in Sacramento, CA. The comparative simulation results examined the impacts of a selected control logic detail, and present an example model-based design application. Overall, the simulation results showed a 25% annual and a 18% summer energy use reduction for alternative controls. This shows that simulation-based control logic design performance evaluation can improve energy efficiency and resilience aspects of system controls at large.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method and apparatus for controlling a powertrain system including a multi-mode transmission

A powertrain including an engine and torque machines is configured to transfer torque through a multi-mode transmission to an output member. A method for controlling the powertrain includes employing a closed-loop speed control system to control torque commands for the torque machines in response to a desired input speed. Upon approaching a power limit of a power storage device transferring power to the torque machines, power limited torque commands are determined for the torque machines in response to the power limit and the closed-loop speed control system is employed to determine an engine torque command in response to the desired input speed and the power limited torque commands for the torque machines.

33 ADVANCED PROPULSION SYSTEMS↗

Realization of a single and closed {lambda}-system in a room-temperature three-level coherently prepared resonant medium with narrow D{sub 1} hyperfine splittings

A single, closed three-state {lambda}-system in room-temperature rubidium is investigated experimentally using a copropagating beam parallel-polarization configuration under weakly driven electromagnetically induced transparency (EIT) condition. Compare with the widely used orthogonal-polarization beam EIT configuration where multiple nonclosed {lambda}-schemes coexist, the parallel-polarizations configuration can completely eliminate the leakage light from the control field. Our state preparation and laser polarization lead to a single and closed {lambda}-scheme that eliminates the detrimental absorption due to nearby states in atomic species with hyperfine separations smaller than Doppler-broadened line widths, a case where the conventional EIT configuration fails completely.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magneto-hydrodynamically stable axisymmetric mirrors

Making axisymmetric mirrors magnetohydrodynamically (MHD) stable opens up exciting opportunities for using mirror devices as neutron sources, fusion-fission hybrids, and pure-fusion reactors. This is also of interest from a general physics standpoint (as it seemingly contradicts well-established criteria of curvature-driven instabilities). The axial symmetry allows for much simpler and more reliable designs of mirror-based fusion facilities than the well-known quadrupole mirror configurations. In this tutorial, after a summary of classical results, several techniques for achieving MHD stabilization of the axisymmetric mirrors are considered, in particular: (1) employing the favorable field-line curvature in the end tanks; (2) using the line-tying effect; (3) controlling the radial potential distribution; (4) imposing a divertor configuration on the solenoidal magnetic field; and (5) affecting the plasma dynamics by the ponderomotive force. Some illuminative theoretical approaches for understanding axisymmetric mirror stability are described. The applicability of the various stabilization techniques to axisymmetric mirrors as neutron sources, hybrids, and pure-fusion reactors are discussed; and the constraints on the plasma parameters are formulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices

The Advanced Energy Harvesting Control Schemes for Marine Renewable Energy Devices (Project) investigated, analyzed and modeled advanced turbine control schemes with the objective of increasing the energy harvested by hydrokinetic turbines in turbulent flow. Ocean Renewable Power Company (ORPC) implemented and validated a feedforward controller to increase power capture; and applied and tested the controls on ORPC’s RivGen® Power Systems in Igiugig, Alaska. Assessments of performance improvements were made for the RivGen® in the Igiugig environment and for ORPC’s TidGen® Power System in a reference tidal environment. Annualized Energy Production (AEP) and Levelized Cost of Energy (LCOE) improvements associated with implementation of the recommended control methodology were made for the TidGen® Power System in the DOE reference tidal environment. System Performance Advancement (SPA) goals were selected for the project. SPA targets were to improve Power to Weight Ratio (PWR) and system Availability, with the intention of reducing Levelized Cost of Electricity (LCOE). This project focused primarily reducing in PWR. Reductions in PWR of 25.5% were achieved. Reductions of 20.3% in LCOE were achieved. This project evaluated four types of controllers which were tested in simulation, emulation, a laboratory flume, and the field. The adaptive Kω2 controller performs similarly to the non-adaptive version of the same controller and may be useful in tidal channels where the mean velocity is continually evolving. Trends in simulation were largely verified through experiments, which also provided the opportunity to test assumptions about turbine responsiveness and control resilience to varying scales of turbulence. Laboratory experiments provided an essential stepping stone between simulation and implementation on a field-scale turbine. Experiments also demonstrated that using “energy loss” as a metric to differentiate between well-designed controllers operating at an optimal tip-speed ratio set-point is difficult, which anticipated the outcome from field experiments. The clear message is that the feedforward Kω2 controller out-performs the feedback controllers in almost all aspects and modes of evaluation. The controllers proved a substantial improvement over the baseline performance of the TidGen® turbine, in terms of energy capture. The effects of noise-contaminated angular velocity signals were investigated and validated by simulation as an explanation for the performance limitations observed for TidGen® turbine operations in Eastport, Maine. Measurements of loads performed as part of the laboratory testing indicate that there are limited differences in average axial thrust force between control architectures. This suggests that none of the control strategies are likely to substantially affect loads on the turbine support structure. Velocity measurements during the ORPC RivGen® turbine deployment at Igiugig, Alaska, in 2014 were used to assess the variability of the river flow. Results suggest that the river flow is approximately steady, in the mean sense, at any particular location in the river, with random turbulent fluctuations that are around 10% of the mean flow. The mean flow in the center channel of the river is 2.5 m/s, with reductions near the riverbanks and in the shallows. Spectral analysis and lagged correlation results indicate that temporal fluctuations at a given point are dominated by large scale fluctuations, such that measurements at the turbine location are just as useful for inflow control implementation as upstream measurements. At this site, and likely at many other river sites, flow is generally steady at a given location, but flow varies dramatically between locations, particularly laterally across the river. The primary result is that a lateral change in position of a few meters results in changes to flow speed that far exceed the turbulence fluctuations at any given location. The turbulence is dominated by long time scales. Following final system tests, the RivGen® device was submerged and each evaluated controller was tested across a range of gain/set point values and filter configurations for a minimum of 5 minutes, with longer runs attempted for well-performing cases. In addition to testing controllers during the 2015 deployment season, LGL Alaska Research Associates Inc. (LGL) performed a fish monitoring study in compliance with Alaska Department of Fish and Game fisheries habitat permit for the project. During the season, LGL reviewed 10% of 179 one-hour blocks of footage (6 minutes on the hour) and documented a total of over 1200 fish in the vicinity of the RivGen® device, including over 800 salmon smolt and over 350 adult salmon. No evidence of adverse effects including passage delay by upstream migrating salmon was noted. This is an important result for future deployments and has a direct impact on commercial system designs.

16 TIDAL AND WAVE POWER↗

Secure true random number generation using 1.5-T transistor flash memory

This disclosure relates generally to physically unclonable function (PUF) circuitry along with methods of generating numbers. In one embodiment, the PUF circuitry includes a memory, a memory control circuitry, and whitening circuitry. To reduce or eliminate the systematic bias from the array, whitening circuitry is configured to generate a random number comprising random number bits in response to the memory control circuit implementing at least one sequence of memory cycles on the array of the memory cells in the memory. The whitening circuitry is configured to provide the random number bits of the random number based on the variable bit states stored by the array of the memory cells. On average the whitening circuitry is configured to provide approximately half of the random number bits in the first bit state and half of random number bits in a second bit state.

97 MATHEMATICS AND COMPUTING↗

Efficient Simulation of Welding Distortion in Large Structures and Its Reduction by Jig Constraints

Two large construction machinery structures were welded separately with and without jig constraints. The welding distortion of the entire structure was measured by a 3D coordinate measuring system and simulated by elastic FEM using the inherent deformation method. To obtain an accurate inherent deformation, a thermal elastoplastic FE analysis of simple one-side fillet joints with and without jig constraints was performed. Efficient simulation of welding distortion in large structures was accomplished by applying inherent deformation in a localized region, and the effect of jig constraint on the reduction of welding distortion was clarified. The computation of inherent deformation, the weld zone definition and the conversion of inherent deformation into inherent strain were automated. Measured and computed welding distortions in large structures had a good correspondence with respect to both tendency and magnitude. Further investigation of jig configuration was performed for enhanced reduction of welding distortion. Alternative controlling techniques for common welded structures were also addressed.

36 MATERIALS SCIENCE↗

Multireference symmetry-projected variational approximation for the ground state of the doped one-dimensional Hubbard model

The few determinant (FED) approximation introduced in our previous work [Phys. Rev. B 87, 235129 (2013)] is used to describe the ground state, characterized by well-defined spin and space group symmetry quantum numbers as well as doping fractions $N_e/N_{\text{sites}}$, of one-dimensional Hubbard lattices with nearest-neighbor hopping and periodic boundary conditions. Within this multireference scheme, each ground state is expanded in a given number of nonorthogonal and variationally determined symmetry-projected configurations. The results obtained for the ground-state and correlation energies of half-filled and doped lattices with 30, 34, and 50 sites compare well with the exact Lieb-Wu solutions as well as with those obtained with other state-of-the-art approximations. The structure of the intrinsic symmetry-broken determinants resulting from the variational procedure is interpreted in terms of solitons whose translational and breathing motions can be regarded as basic units of quantum fluctuations. It is also shown that in the case of doped one-dimensional lattices, a part of such fluctuations can also be interpreted in terms of polarons. In addition to momentum distributions, both spin-spin and density-density correlation functions are studied as functions of doping. Further, the spectral functions and density of states, computed with an ansatz whose quality can be well controlled by the number of symmetry-projected configurations used to approximate the $N_e$ ± 1 electron systems, display features beyond a simple quasiparticle distribution, as well as spin-charge separation trends.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System-Level Design Studies for Large Rotors

We examine the effect of rotor design choices on the power capture and structural loading of each major wind turbine component. A steady-state, harmonic model derived from simulations using the NREL aeroelastic code FAST is developed to reduce computational expense while evaluating design trade-offs for rotors with radii greater than 100 m. Design studies are performed, which focus on blade aerodynamic and structural parameters as well as different hub configurations and nacelle placements atop the tower. The effects of tower design and closed-loop control are also analyzed. Design loads are calculated according to the IEC design standards and used to calibrate the harmonic model and quantify uncertainty. Our design studies highlight both industry trends and innovative designs: we progress from a conventional, upwind, 3-bladed rotor, to a rotor with longer, more slender blades that is downwind and 2-bladed. For a 13 MW design, we show that increasing the blade length by 25 m while decreasing the induction factor of the rotor increases annual energy capture by 11% while constraining peak blade loads. A downwind, 2-bladed rotor design is analyzed, with a focus on its ability to reduce peak blade loads by 10% per 5 deg. of cone angle, and also reduce total blade mass. However, when compared to conventional, 3-bladed, upwind designs, the peak main bearing load of the up-scaled, downwind, 2-bladed rotor is increased by 280%. Optimized teeter configurations and individual pitch control can reduce non-rotating damage equivalent loads by 45% and 22%, respectively, compared with fixed-hub designs.

17 WIND ENERGY↗

NUCLEAR CHEMISTRY OF WATER-COOLED FUSION REACTORS: ISSUES AND SOLUTIONS

ITER is an experimental Tokamak fusion energy reactor that is being built in Cadarache, France, in collaboration with seven agencies representing China, the European Union, India, Japan, Republic of Korea, the Russian Federation, and the United States. The main objective of ITER is to demonstrate the scientific and technical feasibility of a controlled fusion reaction An important U.S. contribution is the design, fabrication, and delivery of the Tokamak Cooling Water System (TCWS). This paper describes the main sources of radioactivity in TCWS water, which are the nitrogen isotopes 16N and 17N, tritium, activated corrosion products, and the carbon isotope 14C; the relative contribution of each of these sources to the total radioactive contamination of water; issues related to excess accumulation of these species; and methods to control TCWS radioactivity within acceptable limits. Among these methods are: (1) water purification to minimize corrosion of materials in contact with TCWS water; (2) monitoring of vital chemistry parameters and control of water chemistry; (3) design of proper building structure and/or TCWS loop/geometry configuration; and (4) design of an ITER liquid radwaste facility tailored to TCWS operational requirements. Design of TCWS nuclear chemistry control is crucial to ensuring that the inventory of radioactive species is consistent with the principle of 'As Low as Reasonably Achievable.'

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System and method for minimizing transport related performance losses in a flow battery system

A flow battery system and method of operating the system minimizes performance losses. The flow battery system includes at least one cell, a first tank including a liquid electrolyte, a pump operably connected to the first tank and to the at least one cell, and a second electrolyte tank operably connected to the at least one cell. The flow battery system further includes a memory including program instructions stored therein, at least one sensor configured to a generate at least one signal associated with a sensed condition of the battery system, and a controller operably connected to the at least one sensor, the pump, and the memory and configured to execute the program instructions to determine a dead zone condition exists based upon the at least one signal, and control the pump to pulse flow of the liquid electrolyte to the at least one cell based upon the determination.

Knudsen, Edward↗

Test results of an ITER relevant FPGA when irradiated with neutrons

The data acquisition and control instrumentation cubicles room of the ITER tokamak will be irradiated with neutrons during the fusion reactor operation. A Virtex-6 FPGA from Xilinx (XC6VLX365T-1FFG1156C) is used on the ATCA-IO-PROCESSOR board, included in the ITER Catalog of I and C products - Fast Controllers. The Virtex-6 is a re-programmable logic device where the configuration is stored in Static RAM (SRAM), functional data stored in dedicated Block RAM (BRAM) and functional state logic in Flip-Flops. Single Event Upsets (SEU) due to the ionizing radiation of neutrons causes soft errors, unintended changes (bit-flips) to the values stored in state elements of the FPGA. The SEU monitoring and soft errors repairing, when possible, were explored in this work. An FPGA built-in Soft Error Mitigation (SEM) controller detects and corrects soft errors in the FPGA configuration memory. Novel SEU sensors with Error Correction Code (ECC) detect and repair the BRAM memories. Proper management of SEU can increase reliability and availability of control instrumentation hardware for nuclear applications. The results of the tests performed using the SEM controller and the BRAM SEU sensors are presented for a Virtex-6 FPGA (XC6VLX240T-1FFG1156C) when irradiated with neutrons from the Portuguese Research Reactor (RPI), a 1 MW nuclear fission reactor operated by IST in the neighborhood of Lisbon. Results show that the proposed SEU mitigation technique is able to repair the majority of the detected SEU errors in the configuration and BRAM memories. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grid Cyber-Security Strategy in an Attacker-Defender Model

The progression of cyber-attacks on the cyber-physical system is analyzed by the Probabilistic, Learning Attacker, and Dynamic Defender (PLADD) model. Although our research does apply to all cyber-physical systems, we focus on power grid infrastructure. The PLADD model evaluates the effectiveness of moving target defense (MTD) techniques. We consider the power grid attack scenarios in the AND configurations and OR configurations. In addition, we consider, for the first time ever, power grid attack scenarios involving both AND configurations and OR configurations simultaneously. Cyber-security managers can use the strategy introduced in this manuscript to optimize their defense strategies. Specifically, our research provides insight into when to reset access controls (such as passwords, internet protocol addresses, and session keys), to minimize the probability of a successful attack. Our mathematical proof for the OR configuration of multiple PLADD games shows that it is best if all access controls are reset simultaneously. For the AND configuration, our mathematical proof shows that it is best (in terms of minimizing the attacker's average probability of success) that the resets are equally spaced apart. We introduce a novel concept called hierarchical parallel PLADD system to cover additional attack scenarios that require combinations of AND and OR configurations.

97 MATHEMATICS AND COMPUTING↗

System-level design studies for large rotors

Abstract. We examine the effect of rotor design choices on the power capture and structural loading of each major wind turbine component. A harmonic model for structural loading is derived from simulations using the National Renewable Energy Laboratory (NREL) aeroelastic code FAST to reduce computational expense while evaluating design trade-offs for rotors with radii greater than 100 m. Design studies are performed, which focus on blade aerodynamic and structural parameters as well as different hub configurations and nacelle placements atop the tower. The effects of tower design and closed-loop control are also analyzed. Design loads are calculated according to the IEC design standards and used to create a mapping from the harmonic model of the loads and quantify the uncertainty of the transformation. Our design studies highlight both industry trends and innovative designs: we progress from a conventional, upwind, three-bladed rotor to a rotor with longer, more slender blades that is downwind and two-bladed. For a 13 MW design, we show that increasing the blade length by 25 m, while decreasing the induction factor of the rotor, increases annual energy capture by 11 % while constraining peak blade loads. A downwind, two-bladed rotor design is analyzed, with a focus on its ability to reduce peak blade loads by 10 % per 5° of cone angle and also reduce total blade mass. However, when compared to conventional, three-bladed, upwind designs, the peak main-bearing load of the upscaled, downwind, two-bladed rotor is increased by 280 %. Optimized teeter configurations and individual pitch control can reduce non-rotating damage equivalent loads by 45 % and 22 %, respectively, compared with fixed-hub designs.

17 WIND ENERGY↗

Framework for assessment of magnetic equilibrium controller performance on the MAST upgrade spherical tokamak

Here, in this work we present the assessment framework for magnetic equilibrium controllers on MAST Upgrade spherical tokamak (MAST-U) spherical tokamak. Such controllers are essential for the MAST-U since exhaust physics and core-edge integration studies require advanced divertor plasma configurations. The developed framework is based on the TokSys suite of plasma control codes, which was adapted and upgraded for MAST-U. However, extra capabilities were added on top of TokSys to support the development of new control algorithms, deployment of controllers to the plasma control system (PCS) and evaluation of their performance. The controller assessment was realized via closed-loop integrated control simulations with the actual MAST-U PCS and different physics-based plasma models. Since all components of the assessment chain were experimentally validated, these simulations provide qualified controllers applicable for direct use in the experiment. This resulted in the successful experimental demonstration of advanced plasma shape control on MAST-U with minimal on-machine development time. A similar methodology would be beneficial to other tokamaks, both existing and future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Management of Power Semiconductor Packages - Matching Cooling Technologies with Packaging Technologies (Presentation)

Heat removal for power semiconductor devices is critical for robust operation. Because there are different packaging options, different thermal management technologies, and a range of applications, there is a need for a methodology to match cooling technologies and package configurations to target applications. To meet this need, a methodology was developed to compare the sensitivity of coolingtechnologies on the overall package thermal performance over a range of power semiconductor packaging configurations. The results provide insight into the trade-offs associated with cooling technologies and package configurations. The approach provides a method for comparing new developments in power semiconductor packages and identifying potential thermal control technologies for the package.The results can help users select the appropriate combination of packaging configuration and cooling technology for the desired application.

30 DIRECT ENERGY CONVERSION↗