Search NASA⌕ Search

SEARCH · Search NASA

Results for “Damage characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Multi Resolution In-Situ Testing and Multiscale Simulation for Creep Fatigue Damage Analysis of Alloy 617

This report outlines the research activities that were carried out for the integrated experimental and simulation investigation of creep-fatigue damage mechanism and life prediction of Nickel-based alloy, Inconel 617 at high temperatures (950° and 850°). First, a novel experimental design using a hybrid control technique is proposed. The newly developed experimental technique can generate different combinations of creep and fatigue damage by changing the experimental design parameters. Next, detailed imaging analysis and statistical data analysis are performed to quantify the failure mechanisms of the creep fatigue of alloy 617 at high temperatures. It is observed that the creep damage is directly associated with the internal voids at the grain boundaries and the fatigue damage is directly related to the surface cracking. It is also observed that the classical time fraction approach does not has a good correlation with the experimental observed damage features. An effective time fraction parameter is seen to have an excellent correlation with the material microstructural damage. Thus, a new empirical damage interaction diagram is proposed based on the experimental observations. Following this, a macro level viscoplastic model coupled with damage is developed to simulate the stress/strain response under creep fatigue loadings. A damage rate function based on the hysteresis energy and creep energy is proposed to capture the softening behavior of the material and a good correlation with life prediction and material hysteresis behavior is observed. The simulation work is extended to include the microstructural heterogeneity. A crystal plasticity finite element model considering isothermal and large deformation conditions at the microstructural scale has been developed for fatigue, creep-fatigue as well as creep deformation and rupture at high temperature. The model considers collective dislocation glide and climb of the grains and progressive damage accumulation of the grain boundaries. The glide model incorporates a slip resistance evolution model that characterizes the solute-drag creep effects and can capture well the stress-strain and stress time response of fatigue and creep-fatigue tests at various strain ranges and hold times. In order to accurately capture the creep strains that accumulate particularly at relatively low stress levels, a dislocation climb model has been incorporated into the crystal plasticity modeling framework. The dislocation climb model parameters are calibrated and verified through experimental creep tests performed at 950°. In addition, a cohesive zone model has been fully implemented in the context of the crystal plasticity finite element model to capture the intergranular creep damage. The parameters of the cohesive zone model have been calibrated using available experimental data. The numerical simulations illustrate the capability of the proposed model in capturing damage initiation and growth under creep loads as compared to the experimental observations. The microscale analysis sheds light on the crack initiation sites and propagation patterns within the microstructure. The model is also utilized to investigate the hybrid-controlled creep-fatigue tests and has been found to capture reasonably well the stress-strain response with different hold times and hold stress magnitudes.

36 MATERIALS SCIENCE↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Density determination of nano-layers depending to the thickness by non-destructive method

Non-destructive tests used to characterize and observe the state of the solids near the surface or at depth, without damaging them or damaging them. Density is frequently used to follow the variations of the physical structure of the samples, as well as in the calculation of quantity of material required to fill a given volume, and it is also used to determine the homogeneity of a sample. However, the measurement of the acoustic properties (density, elastic constants,…) of a thin film whose thickness is smaller than several atomic layers is not easy to perform. For that reason, we expose in this work the effects of the thicknesses of thin films on the evolution of the density, where several samples are analyzed. The samples selected structures are thin films deposited on substrates, these coatings have thicknesses varying from a few atomic layers to ten or so micrometers and can change the properties of the substrate on which they are deposited. To do so, we considered a great number of layers (Cr, Al, SiO{sub 2}, ZnO, Cu, AlN, Si{sub 3}N{sub 4}, SiC) deposited on different substrates (Al{sub 2}O{sub 3}, Cu and Quartz). It is first shown that the density exhibits a dispersive behaviour. Such a behaviour is characterized by an initial increase (or decrease) followed by a saturated region. Further investigations of these dependences led to the determination of a semi-empirical universal relations, ρ=f(h/λ{sub T}), for all the investigated layer/substrate combination. Such expression could be of great importance in the density prediction of even layers thicknesses.

36 MATERIALS SCIENCE↗

A constitutive framework for rocks undergoing solid dissolution

Here, we formulate a time-dependent damage theory for rocks subjected to mechanical deformation and solid dissolution. The constitutive description is inspired by the transition state theory, which states that the rate of dissolution is a function of the reactive surface area measured through the crack density in the volume. We use a gradient-enhanced damage framework in which damage depends on the deformation of the material as well as on the amount of solid mass dissolved over time. The gradient-enhanced formulation is characterized by a three-field variational formulation with the solid displacement, nonlocal equivalent strain, and nonlocal rate of solid dissolution as the basic state variables. Traditionally, time-independent damage theories have only allowed damage to increase with increasing external load. In the proposed framework, the degree of damage may increase due to solid dissolution even when the external load is held fixed. In this way, solid dissolution is viewed as a process that is responsible for bringing about rate-dependent effects such as creep and stress-relaxation, which are two common features of geomaterial behavior.

42 ENGINEERING↗

Cationic Dependence of X-ray Induced Damage in Strontium and Barium Nitrate

The response of solids to x-ray irradiation is not well understood, in part, because the interactions between x-rays and molecules in solids depend on the intra- and/or inter-molecular electronic properties of the material. Our previous work demonstrated that x-ray induced damage of certain ionic salts depends on the irradiating photon energy, especially when irradiated with photons of energy near the cation’s K-edge. To advance understanding of the cationic dependence of x-ray photochemistry, we present studies of x-ray induced damage of barium nitrate and strontium nitrate. Polycrystalline samples of barium and strontium nitrate were irradiated with high flux monochromatic synchrotron x-rays at selected energies near the K-edge of the respective cations. The damage processes were studied with powder x-ray diffraction, and irradiation products, NO 2 and O 2 , were characterized via Raman spectroscopy. Our results demonstrate that irradiating barium and strontium nitrate with photons of energy greater than the K-edge of the cation promotes high rate of decomposition compared to that observed when irradiating with photons of energy below the K-edge. Additionally, differences in x-ray induced damage between the two compounds are examined and discussed, and evidence of the diffusion of irradiation products is presented.

36 MATERIALS SCIENCE↗

Vulnerability of the Superficial Zone of Immature Articular Cartilage to Compressive Injury

The zonal composition and functioning of adult articular cartilage causes depth-dependent responses to compressive injury. In immature cartilage, shear and compressive moduli as well as collagen and sulfated glycosaminoglycan (sGAG) content also vary with depth. However, there is little understanding of the depth-dependent damage caused by injury. Since injury to immature knee joints most often causes articular cartilage lesions, this study was undertaken to characterize the zonal dependence of biomechanical, biochemical, and matrix-associated changes caused by compressive injury. Disks from the superficial and deeper zones of bovine calves were biomechanically characterized. Injury to the disks was achieved by applying a final strain of 50% compression at 100%/second, followed by biomechanical recharacterization. Tissue compaction upon injury as well as sGAG density, sGAG loss, and biosynthesis were measured. Collagen fiber orientation and matrix damage were assessed using histology, diffraction-enhanced x-ray imaging, and texture analysis. Injured superficial zone disks showed surface disruption, tissue compaction by 20.3 {+-} 4.3% (mean {+-} SEM), and immediate biomechanical impairment that was revealed by a mean {+-} SEM decrease in dynamic stiffness to 7.1 {+-} 3.3% of the value before injury and equilibrium moduli that were below the level of detection. Tissue areas that appeared intact on histology showed clear textural alterations. Injured deeper zone disks showed collagen crimping but remained undamaged and biomechanically intact. Superficial zone disks did not lose sGAG immediately after injury, but lost 17.8 {+-} 1.4% of sGAG after 48 hours; deeper zone disks lost only 2.8 {+-} 0.3% of sGAG content. Biomechanical impairment was associated primarily with structural damage. The soft superficial zone of immature cartilage is vulnerable to compressive injury, causing superficial matrix disruption, extensive compaction, and textural alteration, which results in immediate loss of biomechanical function. In conjunction with delayed superficial sGAG loss, these changes may predispose the articular surface to further softening and tissue damage, thus increasing the risk of development of secondary osteoarthritis.

59 BASIC BIOLOGICAL SCIENCES↗

The Ductility of 49Fe-49Co-2V Soft Magnetic Alloy Bar: Surface Effects and Test Methods

The tensile ductility of 49Fe-49Co-2V (Hiperco® 50A) bar was investigated in both as-received and heat-treated conditions. The as-received/machined specimens exhibit very low ductility compared to samples where heat treatment was the final step prior to testing. Microstructural characterization showed that internal residual strain from bar processing and, most importantly, surface machining damage, cause lower elongation in the as-received material. Because fracture of this intermetallic alloy initiates at the surface, it is particularly susceptible to surface machining damage, i.e., the near-surface region has already exhausted most of its ability to accumulate tensile strain. During heat treatment, the internal residual strain and near-surface machining damage are eliminated and ductility is improved, despite a higher degree of crystallographic ordering in the heat-treated condition (which typically lowers ductility). Furthermore, if machining is again performed after heat treatment, the material again exhibits brittle behavior, even with only light touch-up machining passes. Here, in this work, methods of tensile strain measurement were investigated, namely conventional knife-edge extensometry and noncontact digital image correlation (DIC) on heat-treated material. For clip-on knife-edge extensometry, the range of failure strain was 2.5-5.5% for heat-treated Hiperco. For noncontact methods, ductility up to 7% was observed. The results highlight the tendency for the alloy to fail at surface imperfections, even those produced by application of the extensometer itself. Noncontact laser extensometry is recommended for determining the intrinsic ductility of the alloy. A method of laser surface modification was developed which increased ductility by ~ 100% compared to unmodified samples. The high cooling rates achieved during laser surface processing can bypass the ordering reaction and produce a ductile disordered structure at the surface that exhibits ductile fracture characteristics.

EBSD↗

Spectroscopic studies of the mechanism of reversible photodegradation of 1-substituted aminoanthraquinone-doped polymers

The mechanism of reversible photodegradation of 1-substituted aminoanthraquinones doped into poly(methyl methacrylate) and polystyrene is investigated. Time-dependent density functional theory is employed to predict the transition energies and corresponding oscillator strengths of the proposed reversibly and irreversibly damaged dye species. Ultraviolet–visible and Fourier transform infrared (FTIR) spectroscopy are used to characterize which species are present. FTIR spectroscopy indicates that both dye and polymer undergo reversible photodegradation when irradiated with a visible laser. These findings suggest that photodegradation of 1-substituted aminoanthraquinones doped in polymers originates from interactions between dyes and photoinduced thermally degraded polymers, and the metastable product may recover or further degrade irreversibly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incorporation of erbium ions into thin-film lithium niobate integrated photonics

As an active material with favorable linear and nonlinear optical properties, thin-film lithium niobate has demonstrated its potential in integrated photonics. Integration with rare-earth ions, which are promising candidates for quantum memories and transducers, will enrich the system with new applications in quantum information processing. In this work, we investigate the optical properties at 1.5 μm wavelengths of rare-earth ions (Er 3+ ) implanted in thin-film lithium niobate waveguides and micro-ring resonators. Optical quality factors near a million after post-annealing show that ion implantation damage can be repaired. The transition linewidth and fluorescence lifetime of erbium ions are characterized. The ion-cavity coupling is observed through a Purcell enhanced fluorescence from which a Purcell factor of 3.8 ± 0.5, compared with waveguide lifetime, is extracted. This platform is compatible with top-down lithography processes and leads to a scalable path for controlling spin-photon interfaces in photonic circuits.

36 MATERIALS SCIENCE↗

Ensembles of novelty detection classifiers for structural health monitoring using guided waves

Guided wave structural health monitoring uses sparse sensor networks embedded in sophisticated structures for defect detection and characterization. The biggest challenge of those sensor networks is developing robust techniques for reliable damage detection under changing environmental and operating conditions. To address this challenge, we develop a novelty classifier for damage detection based on one class support vector machines. We identify appropriate features for damage detection and introduce a feature aggregation method which quadratically increases the number of available training observations.We adopt a two-level voting scheme by using an ensemble of classifiers and predictions. Each classifier is trained on a different segment of the guided wave signal, and each classifier makes an ensemble of predictions based on a single observation. Using this approach, the classifier can be trained using a small number of baseline signals. We study the performance using monte-carlo simulations of an analytical model and data from impact damage experiments on a glass fiber composite plate.We also demonstrate the classifier performance using two types of baseline signals: fixed and rolling baseline training set. The former requires prior knowledge of baseline signals from all environmental and operating conditions, while the latter does not and leverages the fact that environmental and operating conditions vary slowly over time and can be modeled as a Gaussian process.

Dib, Gerges (ORCID:0000000255004047)↗

Microdosimetry of proton and carbon ions

Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u{sup 12}C ion beams in small volumes of diameters 10–100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10–100 nm, dose distributionsyd(y) in lineal energy y, and dose-mean lineal energies y{sup ¯}{sub D}. For monoenergetic ions, the y{sup ¯}{sub D} was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the y{sup ¯}{sub D} depth profile for the 160 MeV proton beam was located at ∼0.5 cm behind the Bragg peak maximum, while the y{sup ¯}{sub D} peak of the 290 MeV/u {sup 12}C beam coincided well with the peak of the absorbed dose profile. Differences between the y{sup ¯}{sub D} and dose-averaged linear energy transfer (LET{sub D}) were large in the proton beam for both target volumes studied, and in the {sup 12}C beam for the 10 nm diameter cylindrical volumes. The y{sup ¯}{sub D} determined for 100 nm diameter cylindrical volumes in the {sup 12}C beam was approximately equal to the LET{sub D}. The contributions from secondary particles to the y{sup ¯}{sub D} of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1–6 in the {sup 12}C beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Fundamental Understanding of Ambient and High-Temperature Plasticity Phenomena in Structural Materials in Advanced Reactors

The goal of this research project is to develop the methods and tools necessary to link unit processes analyzed using atomistic simulations involving interaction of vacancies and interstitials with dislocations, as well as dislocation mediation at sessile junctions and interfaces as affected by radiation, with cooperative influence on higher-length scale behavior of polycrystals. These tools and methods are necessary to design and enhance radiation-induced damage-tolerant alloys. The project will achieve this goal by applying atomistic simulations to characterize unit processes of: 1. Dislocation nucleation, absorption, and desorption at interfaces 2. Vacancy production, radiation-induced segregation of substitutional Cr at defect clusters (point defect sinks) in BCC Fe-Cr ferritic/martensitic steels 3. Investigation of interaction of interstitials and vacancies with impurities (V, Nb, Ta, Mo, W, Al, Si, P, S) 4. Time evolution of swelling (cluster growth) phenomena of irradiated materials 5. Energetics and kinetics of dislocation bypass of defects formed by interstitial clustering and formation of prismatic loops, informing statistical models of continuum character with regard to processes of dislocation glide, vacancy agglomeration and swelling, climb and cross slip This project will consider the Fe, Fe-C, and Fe-Cr ferritic/martensitic material system, accounting for magnetism by choosing appropriate interatomic potentials and validating with first principles calculations. For these alloys, the rate of swelling and creep enhancement is considerably lower than that of face-centered cubic (FCC) alloys and of austenitic Fe-Cr-Mo alloys. The team will confirm mechanisms, validate simulations at various time and length scales, and improve the veracity of computational models. The proposed research's feasibility is supported by recent modeling of radiation effects in metals and alloys, interfacial dislocation transfer reactions in nano-twinned copper, and dislocation reactions at general boundaries, along with extensive modeling cooperative effects of dislocation interactions and migration in crystals and polycrystals using continuum models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mid-term progress report: CRP F11016

SNL is tasked with performing electrical characterization, irradiation, and IBIC, DLTS, CV measurements on devices used in the CRP, calculating damage and ionization profiles for modeling.

36 MATERIALS SCIENCE↗

High-Reliability Systems and the Control of National Security Data and Information

High-reliability systems are characterized by catastrophic implications in the event of failure. These implications can include substantive damage to the environment, social order, and loss of life. Examples of high-reliability systems include nuclear submarines, nuclear reactors, the electric grid, and nuclear weapons. Due to the catastrophic implications of failure, there are heightened awareness and control mechanisms surrounding related data and information. However, defining the difference between data and information is often ambiguous across scholarly disciplines and in United States policy and legislation. For high-reliability systems, the implications of ambiguity between data and information may affect the security of United States interests and even cost lives. For security, data are raw facts or figures without context, while information is the compilation or articulation of data that forms context. Security depends on clarity in the differences between data and information and how to control them. Control is necessary to ensure that data and information are not unintentionally released to foreign governments, the public, or those without need-to-know. A primary concern in the practice of security is the control of data to avoid the unintended conversion to information. Intra-institutionally, this control is highly complex given the amalgam of legacy data systems and the numerous and constantly evolving nature of modern data systems that were not necessarily designed to be integrated. The complexity of this concern is augmented when institutions are part of interinstitutional collaborations or networks of public-private partnerships that share data and information. Additionally, institutions that share data as a function of policy and legislative action— particularly formally integrated data and information system infrastructures—may be at higher security risk. This paper will present an intra-institutional paradigm that utilizes and integrates concepts from numerous disciplines to frame a critical and underspecified practical issue in security—controlling for the unintended conversion of data to information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

High-Reliability Systems and the Control of National Security Data and Information

High-reliability systems are characterized by catastrophic implications in the event of failure. These implications can include substantive damage to the environment, social order, and loss of life. Examples of high-reliability systems include nuclear submarines, nuclear reactors, the electric grid, and nuclear weapons. Due to the catastrophic implications of failure, there are heightened awareness and control mechanisms surrounding related data and information. However, defining the difference between data and information is often ambiguous across scholarly disciplines and in United States policy and legislation. For high-reliability systems, the implications of ambiguity between data and information may affect the security of United States interests and even cost lives. For security, data are raw facts or figures without context, while information is the compilation or articulation of data that forms context. Security depends on clarity in the differences between data and information and how to control them. Control is necessary to ensure that data and information are not unintentionally released to foreign governments, the public, or those without need-to-know. A primary concern in the practice of security is the control of data to avoid the unintended conversion to information. Intra-institutionally, this control is highly complex given the amalgam of legacy data systems and the numerous and constantly evolving nature of modern data systems that were not necessarily designed to be integrated. The complexity of this concern is augmented when institutions are part of inter-institutional collaborations or networks of public-private partnerships that share data and information. Additionally, institutions that share data as a function of policy and legislative action—particularly formally integrated data and information system infrastructures—may be at higher security risk. This paper will present an intra-institutional paradigm that utilizes and integrates concepts from numerous disciplines to frame a critical and underspecified practical issue in security—controlling for the unintended conversion of data to information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

Use of High-Throughput Automated Microbioreactor System for Production of Model IgG1 in CHO Cells

Automated microscale bioreactors (15 mL) can be a useful tool for cell culture engineers. They facilitate the simultaneous execution of a wide variety of experimental conditions while minimizing potential process variability. Applications of this approach include: clone screening, temperature and pH shifts, media and supplement optimization. Furthermore, the small reactor volumes are conducive to large Design of Experiments that investigate a wide range of conditions. This allows upstream processes to be significantly optimized before scale-up where experimentation is more limited in scope due to time and economic constraints. Automated microscale bioreactor systems offer various advantages over traditional small scale cell culture units, such as shake flasks or spinner flasks. However, during pilot scale process development significant care must be taken to ensure that these advantages are realized. When run with care, the system can enable high level automation, can be programmed to run DOE's with a higher number of variables and can reduce sampling time when integrated with a nutrient analyzer or cell counter. Integration of the expert-derived heuristics presented here, with current automated microscale bioreactor experiments can minimize common pitfalls that hinder meaningful results. In the extreme, failure to adhere to the principles laid out here can lead to equipment damage that requires expensive repairs. Furthermore, the microbioreactor systems have small culture volumes making characterization of cell culture conditions difficult. The number and amount of samples taken in-process in batch mode culture is limited as operating volumes cannot fall below 10 mL. This method will discuss the benefits and drawbacks of microscale bioreactor systems.

59 BASIC BIOLOGICAL SCIENCES↗