Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Strain controlled systematic variation of metal-insulator transition in epitaxial NdNiO{sub 3} thin films

We report here the strain dependent structural and electrical transport properties of epitaxial NdNiO{sub 3} thin films. Pulsed laser deposition technique was used to grow the NdNiO{sub 3} thin films on c-axis oriented SrTiO{sub 3} single crystals. Deposited films were irradiated using 200 MeV Ag{sup 15+} ion beam at the varying fluence (1 Multiplication-Sign 10{sup 11}, 5 Multiplication-Sign 10{sup 11}, and 1 Multiplication-Sign 10{sup 12} ions/cm{sup 2}). X-ray diffraction studies confirm the epitaxial growth of the deposited films, which is maintained even up to the highest fluence. Rise in the in-plane compressive strain has been observed after the irradiation. All the films exhibit metal-insulator transition, however, a systematic decrease in the transition temperature (T{sub MI}) has been observed after irradiation, which may be attributed to the increase in the in-plane compression. Raman spectroscopy data reveal that this reduction in T{sub MI}, with the irradiation, is related to the decrease in band gap due to the stress generated by the in-plane compressive strain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Examining the radiation drive asymmetries present in the high foot series of implosion experiments at the National Ignition Facility

This paper details and examines the origins of radiation drive asymmetries present during the initial High Foot implosion experiments. Such asymmetries are expected to reduce the stagnation pressure and the resulting yield of these experiments by several times. Analysis of reemission and dual axis shock timing experiments indicates that a flux asymmetry, with a P2/P0 amplitude that varies from -10 to -5 %, is present during the first shock of the implosion. This first shock asymmetry can be corrected through adjustments to the laser cone fraction. A thin shell model and more detailed radiation hydrodynamic calculations indicate that an additional negative P2/P0 asymmetry during the second or portions of the third shock is required to reach the observed amount of asymmetry in the shape of the ablator at peak implosion velocity. In conjunction with symmetry data from the x-ray self emission produced at stagnation, these models also indicate that after the initially negative P2/P0 flux asymmetry, the capsule experiences a positive P2/P0 flux asymmetry that develops at or before ~2 ns into the peak of the laser power. Here, direct evidence for this inference, using measurements of the x-ray emission produced by the lasers irradiating the hohlraum, is presented. This data indicates that the reduction in the transmitted inner laser cone energy results from impeded propagation through the plasma associated with the ablation of the capsule target. This paper also correlates measurements of the outer cone laser deposition location with variations in the observed x-ray self emission shape from experiments conducted with nominally the same input conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions Between Fe(III)-Oxides and Fe(III)-Phyllosilicates During Microbial Reduction 1: Synthetic Sediments

Fe(III)-oxides and Fe(III)-bearing phyllosilicates are the two major iron sources utilized as electron acceptors by dissimilatory iron-reducing bacteria (DIRB) in anoxic soils and sediments. Although there have been many studies of microbial Fe(III)-oxide and Fe(III)-phyllosilicate reduction with both natural and specimen materials, no controlled experimental information is available on the interaction between these two phases when both are available for microbial reduction. In this study, the model DIRB Geobacter sulfurreducens was used to examine the pathways of Fe(III) reduction in Fe(III)-oxide stripped subsurface sediment that was coated with different amounts of synthetic high surface area goethite. Cryogenic (12K) 57Fe Mössbauer spectroscopy was used to determine changes in the relative abundances of Fe(III)-oxide, Fe(III)-phyllosilicate, and phyllosilicate-associated Fe(II) (Fe(II)-phyllosilicate) in bioreduced samples. Analogous Mössbauer analyses were performed on samples from abiotic Fe(II) sorption experiments in which sediments were exposed to a quantity of exogenous soluble Fe(II) (FeCl22H2O) comparable to the amount of Fe(II) produced during microbial reduction. A Fe partitioning model was developed to analyze the fate of Fe(II) and assess the potential for abiotic Fe(II)-catalyzed reduction of Fe(III)-phyllosilicatesilicates. The microbial reduction experiments indicated that although reduction of Fe(III)-oxide accounted for virtually all of the observed bulk Fe(III) reduction activity, there was no significant abiotic electron transfer between oxide-derived Fe(II) and Fe(III)-phyllosilicatesilicates, with 26-87% of biogenic Fe(II) appearing as sorbed Fe(II) in the Fe(II)-phyllosilicate pool. In contrast, the abiotic Fe(II) sorption experiments showed that 41 and 24% of the added Fe(II) engaged in electron transfer to Fe(III)-phyllosilicate surfaces in synthetic goethite-coated and uncoated sediment. Differences in the rate of Fe(II) addition and system redox potential may account for the microbial and abiotic reaction systems. Our experiments provide new insight into pathways for Fe(III) reduction in mixed Fe(III)-oxide/Fe(III)-phyllosilicate assemblages, and provide key mechanistic insight for interpreting microbial reduction experiments and field data from complex natural soils and sediments.

Wu, Tao↗

A SURVEY OF ALKALI LINE ABSORPTION IN EXOPLANETARY ATMOSPHERES

We obtained over 90 hr of spectroscopic observations of four exoplanetary systems with the Hobby-Eberly Telescope. Observations were taken in transit and out of transit, and we analyzed the differenced spectra-i.e., the transmission spectra-to inspect it for absorption at the wavelengths of the neutral sodium (Na I) doublet at {lambda}{lambda}5889, 5895 and neutral potassium (K I) at {lambda}7698. We used the transmission spectrum at Ca I {lambda}6122-which shows strong stellar absorption but is not an alkali metal resonance line that we expect to show significant absorption in these atmospheres-as a control line to examine our measurements for systematic errors. We use an empirical Monte Carlo method to quantify these systematic errors. In a reanalysis of the same data set using a reduction and analysis pipeline that was derived independently, we confirm the previously seen Na I absorption in HD 189733b at a level of (- 5.26 {+-} 1.69) Multiplication-Sign 10{sup -4} (the average value over a 12 A integration band to be consistent with previous authors). Additionally, we tentatively confirm the Na I absorption seen in HD 209458b (independently by multiple authors) at a level of (- 2.63 {+-} 0.81) Multiplication-Sign 10{sup -4}, though the interpretation is less clear. Furthermore, we find Na I absorption of (- 3.16 {+-} 2.06) Multiplication-Sign 10{sup -4} at <3{sigma} in HD 149026b; features apparent in the transmission spectrum are consistent with real absorption and indicate this may be a good target for future observations to confirm. No other results (Na I in HD 147506b and Ca I and K I in all four targets) are significant to {>=}3{sigma}, although we observe some features that we argue are primarily artifacts.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INNER DISK STRUCTURE, DISK-PLANET INTERACTIONS, AND TEMPORAL EVOLUTION IN THE β PICTORIS SYSTEM: A TWO-EPOCH HST/STIS CORONAGRAPHIC STUDY

We present deep Hubble Space Telescope/Space Telescope Imaging Spectrograph coronagraphic images of the β Pic debris disk obtained at two epochs separated by 15 yr. The new images and the re-reduction of the 1997 data provide the most sensitive and detailed views of the disk at optical wavelengths as well as the yet smallest inner working angle optical coronagraphic image of the disk. Our observations characterize the large-scale and inner-disk asymmetries and we identify multiple breaks in the disk radial surface brightness profile. We study in detail the radial and vertical disk structure and show that the disk is warped. We explore the disk at the location of the β Pic b super-Jupiter and find that the disk surface brightness slope is continuous between 0.''5 and 2.''0, arguing for no change at the separations where β Pic b orbits. The two epoch images constrain the disk's surface brightness evolution on orbital and radiation pressure blow-out timescales. We place an upper limit of 3% on the disk surface brightness change between 3'' and 5'', including the locations of the disk warp, and the CO and dust clumps. We discuss the new observations in the context of high-resolution multi-wavelength images and divide the disk asymmetries in two groups: axisymmetric and non-axisymmetric. The axisymmetric structures (warp, large-scale butterfly, etc.) are consistent with disk structure models that include interactions of a planetesimal belt and a non-coplanar giant planet. The non-axisymmetric features, however, require a different explanation.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-INFRARED THERMAL EMISSION DETECTIONS OF A NUMBER OF HOT JUPITERS AND THE SYSTEMATICS OF GROUND-BASED NEAR-INFRARED PHOTOMETRY

We present detections of the near-infrared thermal emission of three hot Jupiters and one brown dwarf using the Wide-field Infrared Camera (WIRCam) on the Canada-France-Hawaii Telescope (CFHT). These include Ks-band secondary eclipse detections of the hot Jupiters WASP-3b and Qatar-1b and the brown dwarf KELT-1b. We also report Y-band, K {sub CONT}-band, and two new and one reanalyzed Ks-band detections of the thermal emission of the hot Jupiter WASP-12b. We present a new reduction pipeline for CFHT/WIRCam data, which is optimized for high precision photometry. We also describe novel techniques for constraining systematic errors in ground-based near-infrared photometry, so as to return reliable secondary eclipse depths and uncertainties. We discuss the noise properties of our ground-based photometry for wavelengths spanning the near-infrared (the YJHK bands), for faint and bright stars, and for the same object on several occasions. For the hot Jupiters WASP-3b and WASP-12b we demonstrate the repeatability of our eclipse depth measurements in the Ks band; we therefore place stringent limits on the systematics of ground-based, near-infrared photometry, and also rule out violent weather changes in the deep, high pressure atmospheres of these two hot Jupiters at the epochs of our observations.

79 ASTRONOMY AND ASTROPHYSICS↗

THE LICK AGN MONITORING PROJECT 2011: SPECTROSCOPIC CAMPAIGN AND EMISSION-LINE LIGHT CURVES

In the Spring of 2011 we carried out a 2.5 month reverberation mapping campaign using the 3 m Shane telescope at Lick Observatory, monitoring 15 low-redshift Seyfert 1 galaxies. This paper describes the observations, reductions and measurements, and data products from the spectroscopic campaign. The reduced spectra were fitted with a multicomponent model in order to isolate the contributions of various continuum and emission-line components. We present light curves of broad emission lines and the active galactic nucleus (AGN) continuum, and measurements of the broad Hβ line widths in mean and rms spectra. For the most highly variable AGNs we also measured broad Hβ line widths and velocity centroids from the nightly spectra. In four AGNs exhibiting the highest variability amplitudes, we detect anticorrelations between broad Hβ width and luminosity, demonstrating that the broad-line region “breathes” on short timescales of days to weeks in response to continuum variations. We also find that broad Hβ velocity centroids can undergo substantial changes in response to continuum variations; in NGC 4593, the broad Hβ velocity shifted by ∼250 km s{sup −1} over a 1 month period. This reverberation-induced velocity shift effect is likely to contribute a significant source of confusion noise to binary black hole searches that use multi-epoch quasar spectroscopy to detect binary orbital motion. We also present results from simulations that examine biases that can occur in measurement of broad-line widths from rms spectra due to the contributions of continuum variations and photon-counting noise.

79 ASTRONOMY AND ASTROPHYSICS↗

A spectroscopic survey of the fields of 28 strong gravitational lenses

We present the spectroscopic redshift catalog from a wide-field survey of the fields of 28 galaxy-mass strong gravitational lenses. We discuss the acquisition and reduction of the survey data, collected over 40 nights of 6.5 m MMT and Magellan time, employing four different multiobject spectrographs. We determine that no biases are introduced by combining data sets obtained with different telescope and spectrograph combinations. Special care is taken to determine redshift uncertainties using repeat observations. The redshift catalog consists of 9,768 new and unique galaxy redshifts. 82.4% of the catalog redshifts are between z = 0.1 and z = 0.7, and the catalog median redshift is z{sub med}=0.36. The data from this survey will be used to study the lens environments and line-of-sight structures to gain a better understanding of the effects of large-scale structure on lens statistics and lens-derived parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-driven precision determination of the material budget in ALICE

The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biogeochemical Characteristics of Earth's Volcanic Permafrost: An Analog of Extraterrestrial Environments

This article describes a study of frozen volcanic deposits collected from volcanoes Tolbachik and Bezymianny on the Kamchatka Peninsula, Russia, and Deception Island volcano, Antarctica. In addition, we studied suprasnow ash layers deposited after the 2007 eruptions of volcanoes Shiveluch and Bezymianny on Kamchatka. The main objectives were to characterize the presence and survivability of thermophilic microorganisms in perennially frozen volcanic deposits. As opposed to permafrost from the polar regions, viable thermophiles were detected in volcanic permafrost by cultivation, microscopy, and sequencing. In the permafrost of Tolbachik volcano, we observed methane formation by both psychrophilic and thermophilic methanogenic archaea, while at 37°C, methane production was noticeably lower. Thermophilic bacteria isolated from volcanic permafrost from the Deception Island were 99.93% related to Geobacillus stearothermophilus. Furthermore, our data showed biological sulfur reduction to sulfide at 85°C and even at 130°C, where hyperthermophilic archaea of the genus Thermoproteus were registered. Sequences of hyperthermophilic bacteria of the genus Caldicellulosiruptor were discovered in clone libraries from fresh volcanic ash deposited on snow. Microorganisms found in volcanic terrestrial permafrost may serve as a model for the alien inhabitants of Mars, a cryogenic planet with numerous volcanoes. Thermophiles and hyperthermophiles and their metabolic processes represent a guideline for the future exploration missions on Mars.

54 ENVIRONMENTAL SCIENCES↗

Gamma-ray burst data strongly favour the three-parameter fundamental plane (Dainotti) correlation over the two-parameter one

ABSTRACT Gamma-ray bursts (GRBs), observed to redshift z = 9.4, are potential probes of the largely unexplored z ∼ 2.7–9.4 part of the early Universe. Thus, finding relevant relations among GRB physical properties is crucial. We find that the Platinum GRB data compilation, with 50 long GRBs (with relatively flat plateaus and no flares) in the redshift range 0.553 ≤ z ≤ 5.0, and the LGRB95 data compilation, with 95 long GRBs in 0.297 ≤ z ≤ 9.4, as well as the 145 GRB combination of the two, strongly favour the 3D Fundamental Plane (Dainotti) correlation (between the peak prompt luminosity, the luminosity at the end of the plateau emission, and its rest-frame duration) over the 2D one (between the luminosity at the end of the plateau emission and its duration). The 3D Dainotti correlations in the three data sets are standardizable. We find that while LGRB95 data have ∼50 per cent larger intrinsic scatter parameter values than the better-quality Platinum data, they provide somewhat tighter constraints on cosmological-model and GRB-correlation parameters, perhaps solely due to the larger number of data points, 95 versus 50. This suggests that when compiling GRB data for the purpose of constraining cosmological parameters, given the quality of current GRB data, intrinsic scatter parameter reduction must be balanced against reduced sample size.

79 ASTRONOMY AND ASTROPHYSICS↗

Design of a Do-It-Yourself Geiger-Muller Counter With Smartphone Mapping Application

Legacy Geiger-Muller (GM) survey meters recovered from fallout shelters have been used by several nuclear scientific societies as part of high school outreach programs. A donated antique instrument helps teachers demonstrate radiological principles, but fails to develop student's electronics skills, generate excitement for nuclear careers, or provide individuals with their own devices to explore the radioactive planet. A simple, affordable GM survey meter built by each student would increase direct engagement while providing hands-on experience with circuit-building, soldering, and computer programming. The inclusion of an affordable single-board computer as a component in the survey meter would enable students to tackle more various computer science and electronics projects, thereby potentially recruiting more students into technology and engineering. This paper details the challenges faced by an interdisciplinary undergraduate team designing an easy-to-assemble smart GM survey meter. Their iterative research, design, and testing process included modification to a basic circuit to enable use of different tube types, component cost reduction, application development, and data communication. The ultimate product of the team's efforts, a survey meter with affordable components and a smartphone application capable of creating radiation maps, is detailed in full.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractionalized excitations probed by ultrasound

In this work, we study magnetoelastic interactions by means of ultrasound experiments in 𝛼−RuCl 3 —a prototypical material for the Kitaev spin model on the honeycomb lattice, with a possible spin-liquid state featuring Majorana fermions and ℤ 2 -flux excitations. We present results of the temperature and in-plane magnetic-field dependence of the sound velocity and sound attenuation for several longitudinal and transverse phonon modes propagating along high-symmetry crystallographic directions. A comprehensive data analysis above the magnetically ordered state provides strong evidence of phonon scattering by Majorana fermions. This scattering depends sensitively on the value of the phonon velocities relative to the characteristic velocity of the low-energy fermionic excitations describing the spin dynamics of the underlying Kitaev magnet. Moreover, our data displays a distinct reduction of anisotropy of the sound attenuation, consistent with the presence of thermally excited ℤ 2 visons. Here, we demonstrate the potential of phonon dynamics as a promising probe for uncovering fractionalized excitations in 𝛼−RuCl 3 and provide new insights into the 𝐻−𝑇 phase diagram of this material.

Kitaev magnet↗

Doping dependence of the magnitude of fluctuating spin moments in the normal state of the pnictide superconductor Sr ( F e 1 - x C o x ) 2 A s 2 inferred from photoemission spectroscopy

We report systematic temperature- and doping-dependent measurements of the Fe3s core-level photoemission spectra in the normal state of superconducting Sr(Fe 1- x Co x ) 2 As 2 . The analysis of the Fe3s spectrum provides an element-specific determination of the mean value of the magnitude of the Fe spin moment measured on the fast (10 -16 -10 -15 s) timescale of the photoemission process. The data reveal the ubiquitous presence in the normal state of Fe spin moments with magnitude fluctuating on short timescales. The data reveal a significant reduction of the magnitude of the effective Fe spin moment on going from the parent to the optimal doped compound. The doping dependence of the magnitude of the spin moment at higher doping level is less clear, being either constant, or even nonmonotonic, depending on temperature. This phenomenology indicates the importance of the interaction between spin and itinerant degrees of freedom in shaping the properties of the normal state. These findings reaffirm the complexity of the normal state of 122 Fe-pnictides, which are typically viewed as the least correlated of the high-temperature unconventional superconductors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Iterative Monte Carlo analysis of spin-dependent parton distributions

We present a comprehensive new global QCD analysis of polarized inclusive deep-inelastic scattering, including the latest high-precision data on longitudinal and transverse polarization asymmetries from Jefferson Lab and elsewhere. The analysis is performed using a new iterative Monte Carlo fitting technique which generates stable fits to polarized parton distribution functions (PDFs) with statistically rigorous uncertainties. Inclusion of the Jefferson Lab data leads to a reduction in the PDF errors for the valence and sea quarks, as well as in the gluon polarization uncertainty at x ≳ 0.1. Furthermore, the study also provides the first determination of the flavor-separated twist-3 PDFs and the d 2 moment of the nucleon within a global PDF analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1{sub 1}-norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1{sub 1}-norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that currently achieved with clinical OSEM reconstructions.

60 APPLIED LIFE SCIENCES↗

Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation

Purpose: Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior–inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). Methods: Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. Results: Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior–inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. Conclusions: The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗