Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Ultra-Structural Imaging Provides 3D Organization of 46 Chromosomes of a Human Lymphocyte Prophase Nucleus

Three dimensional (3D) ultra-structural imaging is an important tool for unraveling the organizational structure of individual chromosomes at various stages of the cell cycle. Performing hitherto uninvestigated ultra-structural analysis of the human genome at prophase, we used serial block-face scanning electron microscopy (SBFSEM) to understand chromosomal architectural organization within 3D nuclear space. Acquired images allowed us to segment, reconstruct, and extract quantitative 3D structural information about the prophase nucleus and the preserved, intact individual chromosomes within it. Our data demonstrate that each chromosome can be identified with its homolog and classified into respective cytogenetic groups. Thereby, we present the first 3D karyotype built from the compact axial structure seen on the core of all prophase chromosomes. The chromosomes display parallel-aligned sister chromatids with familiar chromosome morphologies with no crossovers. Furthermore, the spatial positions of all 46 chromosomes revealed a pattern showing a gene density-based correlation and a neighborhood map of individual chromosomes based on their relative spatial positioning. A comprehensive picture of 3D chromosomal organization at the nanometer level in a single human lymphocyte cell is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Heavy/Medium-Duty Fuel Consumption Based on Drive Cycle Properties

This paper presents multiple methods for predicting heavy/medium-duty vehicle fuel consumption based on driving cycle information. A polynomial model, a black box artificial neural net model, a polynomial neural network model, and a multivariate adaptive regression splines (MARS) model were developed and verified using data collected from chassis testing performed on a parcel delivery diesel truck operating over the Heavy Heavy-Duty Diesel Truck (HHDDT), City Suburban Heavy Vehicle Cycle (CSHVC), New York Composite Cycle (NYCC), and hydraulic hybrid vehicle (HHV) drive cycles. Each model was trained using one of four drive cycles as a training cycle and the other three as testing cycles. By comparing the training and testing results, a representative training cycle was chosen and used to further tune each method. HHDDT as the training cycle gave the best predictive results, because HHDDT contains a variety of drive characteristics, such as high speed, acceleration, idling, and deceleration. Among the four model approaches, MARS gave the best predictive performance, with an average absolute percent error of -1.84% over the four chassis dynamometer drive cycles. To further evaluate the accuracy of the predictive models, the approaches were first applied to real-world data. MARS outperformed the other three approaches, providing an average absolute percent error of -2.2% of four real-world road segments. The MARS model performance was then compared to HHDDT, CSHVC, NYCC, and HHV drive cycles with the performance from Future Automotive System Technology Simulator (FASTSim). The results indicated that the MARS method achieved a comparative predictive performance with FASTSim.

33 ADVANCED PROPULSION SYSTEMS↗

DPP-PMRF: Rethinking Optimization for a Probabilistic Graphical Model Using Data-Parallel Primitives

We present a new parallel algorithm for probabilistic graphical model optimization. The algorithm relies on data-parallel primitives (DPPs), which provide portable performance over hardware architecture. We evaluate results on CPUs and GPUs for an image segmentation problem. Compared to a serial baseline, we observe runtime speedups of up to 13X (CPU) and 44X (GPU). We also compare our performance to a reference, OpenMP-based algorithm, and find speedups of up to 7X (CPU).

97 MATHEMATICS AND COMPUTING↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GD-1 Stellar Stream and Cocoon in the DESI Early Data Release

We present ∼115 new spectroscopically identified members of the GD-1 tidal stream observed with the 5000-fiber Dark Energy Spectroscopic Instrument (DESI). We confirm the existence of a “cocoon,” which is a broad (FWHM ∼ 2:932 ∼ 460 pc) and kinematically hot (velocity dispersion, σ ∼ 5–8 km s −1 ) component that surrounds a narrower (FWHM ∼ 0:353 ∼ 55 pc) and colder [(σ = 3.09 ± 0.76 km s −1 )] thin stream component (based on a median per star velocity precision of 2.7 km s −1 ). The cocoon extends over at least a 30 ∘ segment of the stream observed by DESI. The thin and cocoon components have similar mean values of [Fe/H]: −2.54 ± 0.04 dex and −2.47 ± 0.06 dex, suggestive of a common origin. The data are consistent with the following scenarios for the origin of the cocoon. The progenitor of the GD-1 stream was an accreted globular cluster (GC) and: (a) the cocoon was produced by pre-accretion tidal stripping of the GC while it was still inside its parent dwarf galaxy; (b) the cocoon comprises debris from the parent dwarf galaxy; (c) an initially thin GC tidal stream was heated by impacts from dark subhalos in the Milky Way; (d) an initially thin GC stream was heated by a massive Sagittarius dwarf galaxy; or a combination of some of these. Future DESI spectroscopy and detailed modeling may enable us to distinguish between these possible origins.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing system dynamics with a weighted and directed network constructed from time series data

In this work, we propose a novel method to transform a time series into a weighted and directed network. For a given time series, we first generate a set of segments via a sliding window, and then use a doubly symbolic scheme to characterize every windowed segment by combining absolute amplitude information with an ordinal pattern characterization. Based on this construction, a network can be directly constructed from the given time series: segments corresponding to different symbol-pairs are mapped to network nodes and the temporal succession between nodes is represented by directed links. With this conversion, dynamics underlying the time series has been encoded into the network structure. We illustrate the potential of our networks with a well-studied dynamical model as a benchmark example. Results show that network measures for characterizing global properties can detect the dynamical transitions in the underlying system. Moreover, we employ a random walk algorithm to sample loops in our networks, and find that time series with different dynamics exhibits distinct cycle structure. That is, the relative prevalence of loops with different lengths can be used to identify the underlying dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2D-to-3D image translation of complex nanoporous volumes using generative networks

Image-based characterization offers a powerful approach to studying geological porous media at the nanoscale and images are critical to understanding reactive transport mechanisms in reservoirs relevant to energy and sustainability technologies such as carbon sequestration, subsurface hydrogen storage, and natural gas recovery. Nanoimaging presents a trade off, however, between higher-contrast sample-destructive and lower-contrast sample-preserving imaging modalities. Furthermore, high-contrast imaging modalities often acquire only 2D images, while 3D volumes are needed to characterize fully a source rock sample. In this work, we present deep learning image translation models to predict high-contrast focused ion beam-scanning electron microscopy (FIB-SEM) image volumes from transmission X-ray microscopy (TXM) images when only 2D paired training data is available. We introduce a regularization method for improving 3D volume generation from 2D-to-2D deep learning image models and apply this approach to translate 3D TXM volumes to FIB-SEM fidelity. We then segment a predicted FIB-SEM volume into a flow simulation domain and calculate the sample apparent permeability using a lattice Boltzmann method (LBM) technique. Results show that our image translation approach produces simulation domains suitable for flow visualization and allows for accurate characterization of petrophysical properties from non-destructive imaging data.

58 GEOSCIENCES↗

Investigation of the Relationship Between Gross Tumor Volume Location and Pneumonitis Rates Using a Large Clinical Database of Non-Small-Cell Lung Cancer Patients

Purpose: Studies have suggested that function may vary throughout the lung, and that patients who have tumors located in the base of the lung are more susceptible to radiation pneumonitis. The purpose of our study was to investigate the relationship between gross tumor volume (GTV) location and pneumonitis rates using a large clinical database of 547 patients with non-small-cell lung cancer. Methods and Materials: The GTV centroids of all patients were mapped onto one common coordinate system, in which the boundaries of the coordinate system were defined by the extreme points of each individual patient lung. The data were qualitatively analyzed by graphing all centroids and displaying the data according to the presence of severe pneumonitis, tumor stage, and smoking status. The centroids were grouped according to superior-inferior segments, and the pneumonitis rates were analyzed. In addition, we incorporated the GTV centroid information into a Lyman-Kutcher-Burman normal tissue complication probability model and tested whether adding spatial information significantly improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. The pneumonitis incidence rates were 16%, 23%, and 21% for the superior, middle, and inferior thirds of the lung, respectively. Qualitatively, the GTV centroids of nonsmokers were notably absent from the superior portion of the lung. In addition, the GTV centroids of patients who had Stage III and IV clinical staging were concentrated toward the medial edge of the lung. The comparison between the GTV centroid model and the conventional dose-volume model did not yield a statistically significant difference in model fit. Conclusions: Lower pneumonitis rates were noted for the superior portion of the lung; however the differences were not statistically significant. For our patient cohort, incorporating GTV centroid information did not lead to a statistically significant improvement in the fit of the pneumonitis model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcription inactivation through local refolding of the RNA polymerase structure

Structural studies of antibiotics not only provide a shortcut to medicine allowing for rational structure-based drug design, but may also capture snapshots of dynamic intermediates that become 'frozen' after inhibitor binding. Myxopyronin inhibits bacterial RNA polymerase (RNAP) by an unknown mechanism. Here we report the structure of dMyx - a desmethyl derivative of myxopyronin B - complexed with a Thermus thermophilus RNAP holoenzyme. The antibiotic binds to a pocket deep inside the RNAP clamp head domain, which interacts with the DNA template in the transcription bubble. Notably, binding of dMyx stabilizes refolding of the {beta}'-subunit switch-2 segment, resulting in a configuration that might indirectly compromise binding to, or directly clash with, the melted template DNA strand. Consistently, footprinting data show that the antibiotic binding does not prevent nucleation of the promoter DNA melting but instead blocks its propagation towards the active site. Myxopyronins are thus, to our knowledge, a first structurally characterized class of antibiotics that target formation of the pre-catalytic transcription initiation complex - the decisive step in gene expression control. Notably, mutations designed in switch-2 mimic the dMyx effects on promoter complexes in the absence of antibiotic. Overall, our results indicate a plausible mechanism of the dMyx action and a stepwise pathway of open complex formation in which core enzyme mediates the final stage of DNA melting near the transcription start site, and that switch-2 might act as a molecular checkpoint for DNA loading in response to regulatory signals or antibiotics. The universally conserved switch-2 may have the same role in all multisubunit RNAPs.

59 BASIC BIOLOGICAL SCIENCES↗

Longitudinal Double-spin Asymmetries for {pi}{sup 0} Production at Forward Rapidity in pp Collisions at {radical}(s) = 200 GeV at STAR

Measurements of the double-spin asymmetry A{sub LL} for inclusive {pi}{sup 0} production in hard pp collisions can provide important constraints on gluonic spin contributions to the proton. The STAR Endcap Electromagnetic Calorimeter is well-suited for these studies, with full azimuthal coverage for pseudorapidities 1.086<{eta}<2, good depth segmentation, and excellent transverse granularity. Details of the {pi}{sup 0} reconstruction algorithms we employed are described. Preliminary results from the 2006 data set for A{sub LL} for {pi}{sup 0,}s at forward rapidities are presented and compared to several NLO pQCD calculations that assume different values for the integral {delta}G.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New velocimetry and revised cartography of the spiral arms in the Milky Way—a consistent symbiosis

Recent advances in the determinations of the positions (pitch angle, shape, numbers, interarm separation) and velocities (rotation curve) of the spiral arms are evaluated and compared to previous determinations. Based on these results, an average cartographic model is developed that fits the means of basic input data and provides predictions for the locations of the arms in the Milky Way, for each galactic quadrant. For each spiral arm segment in each galactic quadrant, the LSR radial velocities are calculated for the radial distance as well as for its galactic longitude. From our velocimetric model, arm intercepts (between line of sights and spiral arms) are indicated in velocity space and may be used to find the distance and velocity to any arm, in a given longitude range. Velocity comparisons between model predictions and published CO velocity distribution are done for each galactic quadrant, with good results. Our velocimetric model is not hydromagnetic in character, nor is it a particle-simulation scheme, yet it is simple to use for comparisons with the observations and it is in symbiosis and consistent with our cartographic model (itself simple to use for comparisons with observations). A blending in velocity of the Perseus and Cygnus arms is further demonstrated, as well as an apparent longitude-velocity blending of the starting points of the four spiral arms near 4 kpc (not a physical ring). An integrated (distance, velocity) model for the mass in the disk is employed, to yield the total mass of 3.0 × 10{sup 11} M{sub ☉} within a galactic radius of 28 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant to Part-per-Million Precision

We report a measurement of the positive muon lifetime to a precision of 1.0 ppm; it is the most precise particle lifetime ever measured. The experiment used a time-structured, low-energy muon beam and a segmented plastic scintillator array to record more than 2x10{sup 12} decays. Two different stopping target configurations were employed in independent data-taking periods. The combined results give {tau}{sub {mu}}{sup +}(MuLan)=2 196 980.3(2.2) ps, more than 15 times as precise as any previous experiment. The muon lifetime gives the most precise value for the Fermi constant: G{sub F}(MuLan)=1.166 378 8(7)x10{sup -5} GeV{sup -2} (0.6 ppm). It is also used to extract the {mu}{sup -}p singlet capture rate, which determines the proton's weak induced pseudoscalar coupling g{sub P}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate registration of random radiographic projections based on three spherical references for the purpose of few-view 3D reconstruction

Precise registration of radiographic projection images acquired in almost arbitrary geometries for the purpose of three-dimensional (3D) reconstruction is beset with difficulties. We modify and enhance a registration method [R. Schulze, D. D. Bruellmann, F. Roeder, and B. d'Hoedt, Med. Phys. 31, 2849-2854 (2004)] based on coupling a minimum amount of three reference spheres in arbitrary positions to a rigid object under study for precise a posteriori pose estimation. Two consecutive optimization procedures (a, initial guess; b, iterative coordinate refinement) are applied to completely exploit the reference's shadow information for precise registration of the projections. The modification has been extensive, i.e., only the idea of using the sphere shadows to locate each sphere in three dimensions from each projection was retained whereas the approach to extract the shadow information has been changed completely and extended. The registration information is used for subsequent algebraic reconstruction of the 3D information inherent in the projections. We present a detailed mathematical theory of the registration process as well as simulated data investigating its performance in the presence of error. Simulation of the initial guess revealed a mean relative error in the critical depth coordinate ranging between 2.1% and 4.4%, and an evident error reduction by the subsequent iterative coordinate refinement. To prove the applicability of the method for real-world data, algebraic 3D reconstructions from few ({<=}9) projection radiographs of a human skull, a human mandible and a teeth-containing mandible segment are presented. The method facilitates extraction of 3D information from only few projections obtained from off-the-shelf radiographic projection units without the need for costly hardware. Technical requirements as well as radiation dose are low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods

Purpose: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). Methods: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. Results: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V{sub 95%} increased from 90% to 96% and V{sub 107%} decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. Conclusions: MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

60 APPLIED LIFE SCIENCES↗

SU-G-206-15: Effects of Dose Reduction On Emphysema Score

Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Oregon Cascades Play Fairway Analysis: Faults and Heat Flow Maps

This submission includes a fault map of the Oregon Cascades and backarc, a probability map of heat flow, and a fault density probability layer. More extensive metadata can be found within each zip file. For information about "Oregon Faults," contact John David Trimble, Oregon State University. trimbljo@onid.oregonstate.edu

15 GEOTHERMAL ENERGY↗

Final Report for the project titled "Enabling Supernova Computations by Integrated Transport and Provisioning Methods Optimized for Dedicated Channels"

A high-speed optical circuit network is one that offers users rate-guaranteed connectivity between two endpoints, unlike today’s IP-routed Internet in which the rate available to a pair of users fluctuates based on the volume of competing traffic. This particular research project advanced our understanding of circuit networks in two ways. First, transport protocols were developed for circuit networks. In a circuit network, since bandwidth resources are reserved for each circuit on an end-to-end basis (much like how a person reserves a seat on every leg of a multi-segment flight), and the sender is limited to send at the rate of the circuit, there is no possibility of congestion during data transfer. Therefore, no congestion control functions are necessary in a transport protocol designed for circuits. However, error control and flow control are still required because bits can become errored due to noise and interference even on highly reliable optical links, and receivers can, due to multitasking or other reasons, not deplete the receive buffer fast enough to keep up with the sending rate (e.g., if the receiving host is multitasking between receiving a file transfer and some other computation). In this work, we developed two transport protocols for circuits, both of which are described below. Second, this project developed techniques for internetworking different types of connection-oriented networks, which are of two types: circuit-switched or packet-switched. In circuit-switched networks, multiplexing on links is “position based,” where “position” refers to the frequency, time slot, and port (fiber), while connection-oriented packet-switched networks use packet header information to demultiplex packets and switch them from node to node. The latter are commonly referred to as virtual circuit networks. Examples of circuit networks are time-division multiplexed Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) and Wavelength Division Multiplexing (WDM) networks, while examples of virtual-circuit networks are MultiProtocol Label Switched (MPLS) networks and Ethernet Virtual Local Area Network (VLAN) networks. A series of new technologies have been developed to carry Ethernet VLAN tagged frames on SONET/SDH and WDM networks, such as Generic Framing Procedure (GFP) and ITU G.709, respectively. These technologies form the basis of our solution for connection-oriented internetworking. The benefit of developing such an architecture is that it allows different providers to choose different connection-oriented networking technologies for their networks, and yet be able to allow their customers to connect to those of other providers. As Metcalfe, the inventor of Ethernet, noted, the value of a network service grows exponentially with the number of endpoints to which any single endpoint can connect. Therefore internetworking solutions are key to commercial success. The technical effectiveness of our solutions was measured with proof-of-concept prototypes and experiments. These solutions were shown to be highly effective. Economic feasibility requires business case analyses that were beyond the scope of this project. The project results are beneficial to the public as they demonstrate the viability of simultaneously supporting different types of networks and data communication services much like the variety of services available for the transportation of people and goods. For example, Fedex service offers a deadline based delivery while the USPS offers basic package delivery service. Similarly, a circuit network can offer a deadline based delivery of a data file while the IP-routed network offers only basic delivery service with no guarantees. Two project Web sites, 13 publications, 7 software programs, 21 presentations resulted from this work. This report provides the complete list of publications, software programs and presentations. As for student education and training (human resources), this DOE project, along with an NSF project, jointly supported two postdoctoral fellowships, three PhDs, three Masters, and two undergraduate students. Specifically, two of the Masters students were directly funded on this DOE project.

99 GENERAL AND MISCELLANEOUS↗