Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Absolute charge calibration of scintillating screens for relativistic electron detection

We report on new charge calibrations and linearity tests with high-dynamic range for eight different scintillating screens typically used for the detection of relativistic electrons from laser-plasma based acceleration schemes. The absolute charge calibration was done with picosecond electron bunches at the ELBE linear accelerator in Dresden. The lower detection limit in our setup for the most sensitive scintillating screen (KODAK Biomax MS) was 10 fC/mm{sup 2}. The screens showed a linear photon-to-charge dependency over several orders of magnitude. An onset of saturation effects starting around 10-100 pC/mm{sup 2} was found for some of the screens. Additionally, a constant light source was employed as a luminosity reference to simplify the transfer of a one-time absolute calibration to different experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray nanobeam characterization by coherent diffraction microscopy

We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a digital multiradian phase detector and its application in fusion plasma interferometry

We discuss the circuit design of a digital multiradian phase detector that measures the phase difference between two 10 kHz square wave TTL signals and provides the result as a binary number. The phase resolution of the circuit is 1/64 period and its dynamic range is 256 periods. This circuit has been developed for fusion plasma interferometry with submillimeter waves on the ASDEX Upgrade tokamak. The results from interferometric density measurement are discussed and compared to those obtained with the previously used phase detectors, especially with respect to the occurrence of phase jumps. It is illustrated that the new phase measurement provides a powerful tool for automatic real-time validation of the measured density, which is important for feedback algorithms that are sensitive to spurious density signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inertial measurement with trapped particles: A microdynamical system

We describe an inertial measurement device based on an electrodynamically trapped proof mass. Mechanical constraints are replaced by guiding fields, permitting the trap stiffness to be tuned dynamically. Optical readout of the proof mass motion provides a measurement of acceleration and rotation, resulting in an integrated six degree of freedom inertial measurement device. We demonstrate such a device - constructed without microfabrication - with sensitivity comparable to that of commercial microelectromechanical systems technology and show how trapping parameters may be adjusted to increase dynamic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanopositioning techniques development for synchrotron radiation instrumentation applications at the Advanced Photon Source

At modern synchrotron radiation sources and beamlines, high-precision positioning techniques present a significant opportunity to support state-of-the-art synchrotron radiation research. Meanwhile, the required instrument positioning performance and capabilities, such as resolution, dynamic range, repeatability, speed, and multiple axes synchronization are exceeding the limit of commercial availability. This paper presents the current nanopositioning techniques developed for the Argonne Center for Nanoscale Materials (CNM)/Advanced Photon Source (APS) hard x-ray nanoprobe and high-resolution x-ray monochromators and analyzers for the APS X-ray Operations and Research (XOR) beamlines. Future nanopositioning techniques to be developed for the APS renewal project will also be discussed.

43 PARTICLE ACCELERATORS↗

Scaling the energy conversion rate from magnetic field reconnection to different bodies

Magnetic field reconnection is often invoked to explain electromagnetic energy conversion in planetary magnetospheres, stellar coronae, and other astrophysical objects. Because of the huge dynamic range of magnetic fields in these bodies, it is important to understand energy conversion as a function of magnetic field strength and related parameters. It is conjectured theoretically and shown experimentally that the energy conversion rate per unit area in reconnection scales as the cube of an appropriately weighted magnetic field strength divided by the square root of an appropriately weighted density. With this functional dependence, the energy release in flares on the Sun, the large and rapid variation of the magnetic flux in the tail of Mercury, and the apparent absence of reconnection on Jupiter and Saturn, may be understood. Electric fields at the perihelion of the Solar Probe Plus mission may be tens of V/m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An accurate continuous calibration system for high voltage current transformer

A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

42 ENGINEERING↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled Serial and Parallel Non-uniform SQUIDs

In this work we numerical model series and parallel non-uniform superconducting quantum interference device (SQUID) array. Previous work has shown that series SQUID array constructed with a random distribution of loop sizes, (i.e. different areas for each SQUID loop) there exists a unique 'anti-peak' at the zero magnetic field for the voltage versus applied magnetic field (V-B). Similar results extend to a parallel SQUID array where the difference lies in the arrangement of the Josephson junctions. Other system parameter such as bias current, the number of loops, and mutual inductances are varied to demonstrate the change in dynamic range and linearity of the V-B response. Application of the SQUID array as a low noise amplifier (LNA) would increase link margins and affect the entire communication system. For unmanned aerial vehicles (UAVs), size, weight and power are limited, the SQUID array would allow use of practical 'electrically small' antennas that provide acceptable gain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary characterization of a low-powered microwave induced flame plasma for direct organic solvent nebulization

A low powered (<90 W) microwave-induced plasma has been generated at atmospheric pressure by using a Beenakker cavity, a laboratory constructed torch, and a gas mixture of argon (400 ml/min), hydrogen (100 ml/min), and air (130 ml/min). This plasma has an excitation temperature of 3300-3500 K, electron number density of 7 x 10{sup 14} cm{sup -3}, and easily accepts direct methanol and ethanol introduction with a 1 ml/min solution nebulization rate. Detection limits (3{sigma}) obtained from the atomic emission signals of Li, Sr, and Cr in water are 15, 120, and 290 ng/ml, respectively. Similarly, detection limits for the metals in methanol are 15, 120, and 260 ng/ml, respectively, and in ethanol they are 25, 360, and 330 ng/ml, respectively. The linear dynamic range is greater than three orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of nanoscale patterns in lithium fluoride crystal using a 13.5 nm Schwarzschild objective and a laser produced plasma source

Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 {mu}m diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher order parametric excitation modes for spaceborne quadrupole mass spectrometers

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupole mass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system. When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

An accurate system for onsite calibration of electronic transformers with digital output

Calibration systems with digital output are used to replace conventional calibration systems because of principle diversity and characteristics of digital output of electronic transformers. But precision and unpredictable stability limit their onsite application even development. So fully considering the factors influencing accuracy of calibration system and employing simple but reliable structure, an all-digital calibration system with digital output is proposed in this paper. In complicated calibration environments, precision and dynamic range are guaranteed by A/D converter with 24-bit resolution, synchronization error limit is nanosecond by using the novelty synchronization method. In addition, an error correction algorithm based on the differential method by using two-order Hanning convolution window has good inhibition of frequency fluctuation and inter-harmonics interference. To verify the effectiveness, error calibration was carried out in the State Grid Electric Power Research Institute of China and results show that the proposed system can reach the precision class up to 0.05. Actual onsite calibration shows that the system has high accuracy, and is easy to operate with satisfactory stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPHERES, Juelich's high-flux neutron backscattering spectrometer at FRM II

SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Juelich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 {mu}eV, a dynamic range of {+-} 31 {mu}eV, and a signal-to-noise ratio of up to 1750:1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution and site-specific scanning spreading resistance microscopy and its applications to silicon devices

Due to the continuous reduction of the critical dimensions of semiconductor devices, it becomes very important to know the two dimensional (2D) doping profile for improving device performance. Scanning spreading resistance microscopy (SSRM) performed in high vacuum is a powerful technique for quantitative 2D-doping profiling, with high spatial resolution and wide dynamic range of carrier concentration, as well as capability of site-specific analysis for accurate position. In this paper, we review SSRM applications to source/drain engineering in Si devices and their correlation with device characteristics by demonstrating several case studies. Direct observation of (110)/(100) CMOSFETs clarified significant differences between both pFETs and nFETs on (110) and (100) silicon substrates, revealing 2D channeling effect of boron ion implantation in pFETs; as well as silicidation impact on junction leakage-current characteristics in nFETs. Furthermore, our sample-preparation breakthrough enables site-specific SSRM characterization within 60 nm ultra thin samples and therefore failure analysis of real SRAM devices, demonstrating the high potential of SSRM technology for further device scaling and for failure analysis.

36 MATERIALS SCIENCE↗