Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Considerations for Femtosecond Laser Electronic Excitation Tagging in High-Speed Flows

Femtosecond laser electronic excitation tagging (FLEET) is an unseeded method for molecular tagging which offers valuable opportunities for measurement of high-speed (transonic, supersonic or hypersonic) flows. The unique nature of high-speed testing demands certain performance from FLEET such as satisfactory signal-to-noise ratio (SNR) at depressed static conditions (i.e., low temperatures, pressures and densities), wide dynamic range for velocity determination (especially single-shot), and measurements with acceptable accuracy and precision. This dissertation strives to evaluate FLEET in those regards and provide strategies to maximize the method's capabilities. A zero-dimensional kinetics model in nitrogen explains FLEET signal changes with pressure/density and/or temperature in terms of plasma-chemical reactions. Poorly known rate coefficients are tuned by comparing model output to measurements, with temporal agreement up to several hundred nanoseconds. Modeling reveals that initial signal peaks at reduced density because of slowed temporal evolution (and decay) of excited populations. Low temperatures enhance signal by enlarging cluster ion populations which contribute to excited species via electron-ion dissociative recombination. A purpose-built free jet facility provides experimental validation of the kinetics model and assesses FLEET velocimetry in low temperature and pressure/density conditions. Signal, lifetime, accuracy and precision results are obtained from unheated subsonic through Mach 4.0 operation of the facility, with best results noted. FLEET measurements of a sweeping jet (SWJ) actuator in compressible operation showcase its advantages in a highly unsteady jet containing subsonic through supersonic velocities. FLEET velocimetry is performed in the device's internal and external flow fields, with the latter compared to hot-wire anemometry. Internal measurements reveal the absence of shockwaves theorized to occur at high pressure ratios. Simultaneous qualitative measurements of compressible jet mixing are shown as a proof-of-concept. Overall, the work demonstrates that previous understanding of SWJ incompressible operation readily extends into the compressible realm. Practical aspects of performing FLEET velocimetry are detailed, along with strategies for improving measurement quality. Determination of a fundamental precision in nitrogen and air is attempted. Experiments show that increasing time delay and/or SNR improves velocimetry precision. A comparison of five camera systems indicates sensors with larger pixels capture higher SNR data and produce more precise results.

FLEET↗

Terra and Aqua MODIS Intercomparison Using LEO-GEO Double Difference Method

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Terra and Aqua satellites havesuccessfully operated since their launch in 1999 and in 2002, providing more than 18 and 16 years ofcontinuous global observations, respectively. The inter-comparison between the two MODIS instruments can bevery supportive for the instrument calibration and uncertainty assessment. Aqua and Terra MODIS have almostidentical relative spectral response, spatial resolution, and dynamic range for each band. Therefore, a sitedependent correction for a sensor spectral band pair is not necessary for their comparison. However, Terra is inthe morning orbit with an equator crossing time of 10:30 am, and Aqua is in the afternoon orbit with equatorcrossing time of 1:30 pm. Consequently, there is a dearth of simultaneous nadir overpasses (SNOs)between the two satellites. Major challenges in cross-sensor comparison of instruments on different satellitesinclude differences in observation time, solar angle, and view angle over selected pseudo-invariant sites.In this work, the inter-comparisons of thermal emissive bands are performed over a pseudo-invariant target,using the observations from a sensor onboard a geostationary satellite as a bridge. Himawari8 was launched onOctober 7, 2014. The Advanced Himawari Imager (AHI) onboard Himawari8 can be used as a reference tobridge the comparison between Terra and Aqua MODIS. AHI has 16 channels; with spatial resolutions from 0.5km to 2 km at nadir and produces a full disk observations every 10 minutes. The band spectral coveragematchup, comparable spatial resolution and near-simultaneous observation between MODIS and AHI providefeasibility to implement a double difference method. This comparison method minimizes the impact of thedifference in observation time and solar angle. The comparison results will be used as an assessment for MODISinstrument calibration and will be helpful for future enhancement of the L1B product.

Himawari8↗

Calibration Plan for the Ocean Color Instrument (OCI) Engineering Test Unit

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission will launch no earlier than summer 2022. The primary payload is the Ocean Color Instrument (OCI). OCI is a hyperspectral imaging radiometer that will measure top-of-atmosphere radiances from 340nm to 2260nm at approximately 1km spatial resolution. The spectral resolution will be 5nm from 340nm to 890nm to enable the production of innovative ocean color products on a global scale (OCI will provide global coverage every 2 days). There are 7 different multispectral bands in the shortwave infrared to support atmospheric correction for ocean color and aerosol and cloud studies. Ocean color applications require state of the art radiometric accuracy (approximately 0.5%, excluding the absolute calibration uncertainty). Considerable effort has been invested in the planning of the prelaunch calibration campaign and the on-orbit calibration capabilities. This paper describes the current plans for the prelaunch calibration and characterization campaign of the OCI Engineering Test Unit (ETU), which is scheduled to begin towards the end of 2019, and expected to conclude April 2020. The prelaunch calibration campaign will characterize all sensor characteristics that are expected to influence radiometric sensitivity: absolute calibration (i.e. radiometric gains), signal to noise ratio, nonlinearity, response versus scan angle, dynamic range, straylight, crosstalk, and sensitivities to polarization and temperature. In addition to these characterization tests (which will only be performed once for the ETU), two types of tests have been developed that monitor the evolution of several OCI radiometric characteristics: a Limited Performance Test (LPT, expected duration about 8 hours), and a Comprehensive Performance Test (CPT, expected duration about 2 days).

Meister, Gerhard↗

Version 4 of the SMAP Level-4 Soil Moisture Algorithm and Data Product

The NASA Soil Moisture Active Passive (SMAP) mission Level-4 Soil Moisture (L4_SM) product provides global, 3-hourly, 9-km resolution estimates of surface (0-5 cm) and root-zone (0-100 cm) soil moisture with a mean latency of ~2.5 days. The underlying L4_SM algorithm assimilates SMAP radiometer brightness temperature (Tb) observations into the NASA Catchment land surface model using a spatially-distributed ensemble Kalman filter. Version 4 of the L4_SM modeling system includes a reduction in the upward recharge of surface soil moisture from below under non-equilibrium conditions, resulting in reduced bias and improved dynamic range of L4_SM surface soil moisture compared to earlier versions. This change and additional technical modifications to the system reduce the mean and standard deviation of the observation-minus-forecast Tb residuals and overall soil moisture analysis increments while maintaining the skill of the L4_SM soil moisture estimates versus independent in situ measurements; the average, bias-adjusted RMSE in Version 4 is 0.039 m(exp 3) m(exp -3) for surface and 0.026 m(exp 3) m(exp -3) for root-zone soil moisture. Moreover, the coverage of assimilated SMAP observations in Version 4 is near-global owing to the use of additional satellite Tb records for algorithm calibration. L4_SM soil moisture uncertainty estimates are biased low (by 0.01-0.02 m(exp 3) m(exp -3)) against actual errors (computed versus in situ measurements). L4_SM runoff estimates, an additional product of the L4_SM algorithm, are biased low (by 35 mm year (exp -1)) against streamflow measurements. Compared to Version 3, bias in Version 4 is reduced by 46% for surface soil moisture uncertainty estimates and by 33% for runoff estimates.

RMSE↗

A Global End-Member Approach to Derive aCDOM(440) from Near-Surface Optical Measurements

This study establishes an optical inversion scheme for deriving the absorption coefficient of colored (or chromophoric, depending on the literature) dissolved organic material (CDOM) at the 440 nm wavelength, which can be applied to global water masses with near-equal efficacy. The approach uses a ratio of diffuse attenuation coefficient spectral end members, i.e., a short and long wavelength pair. The global perspective is established by sampling "extremely" clear water plus a generalized extent in turbidity and optical properties that each span three decades of dynamic range. A unique data set was collected in oceanic, coastal, and inland waters (as shallow as 0.6 m) from the North Pacific Ocean, the Arctic Ocean, Hawaii, Japan, Puerto Rico, and the east and west coasts of the United States. The data were partitioned using subjective categorizations to define a validation quality subset of conservative water masses, i.e., the inflow and outflow of properties constrain the range in the gradient of a constituent, plus 15 subcategories of water masses that were not evolving conservatively. The dependence on subcategories was confirmed with an objective methodology based on cluster analysis techniques. The latter defined five distinct classes with validation quality data present in all classes, but which also decreased in percent composition as a function of increasing class number and optical complexity. Four different algorithms based on different validation quality end members were validated with accuracies of 1.–6.2 %, wherein pairs with the largest spectral span were most accurate. Although algorithm accuracy decreased with the inclusion of more subcategories containing non-conservative water masses, changes to the algorithm fit were small when a preponderance of subcategories were included. The high accuracy for all end-member algorithms was the result of data acquisition and data processing improvements, e.g., increased vertical sampling resolution to less than 1mm and a boundary constraint to mitigate wave focusing effects, respectively. An independent evaluation with a historical database confirmed the consistency of the algorithmic approach and its application to quality assurance, e.g., to flag data outside expected ranges, identify suspect spectra, and objectively determine the in-water extrapolation interval by converging agreement for all applicable end-member algorithms. The legacy data exhibit degraded performance (as 44 % uncertainty) due to a lack of high-quality near-surface observations, especially for clear waters wherein wave-focusing effects are problematic. The novel optical approach allows the in situ estimation of an in-water constituent in keeping with the accuracy obtained in the laboratory.

Stanford B Hooker↗

TPSAS-NF1676L-10737-DND

The Clouds and the Earth's Radiant Energy System (CERES) project provides the community a quality climate TOA and surface fluxes and cloud properties and are key elements in evaluating the ability of climate models to predict both past and future climate states. One important aspect of successful climate monitoring is satellite calibration. The CERES instantaneous broadband calibration radiance stability is 0.1% per year, whereas the accuracy of the longwave (LW) and shortwave (SW) is better than 0.5% and 1% respectively. CERES uses the 3-hourly GEO fluxes and clouds to provide diurnally averaged daily and monthly TOA flux means from the CERES measurements onboard the Terra (10:30 AM local equator crossing time) and Aqua (13:30 PM) sun-synchronous satellites. The GEO radiances are calibrated against MODIS as a reference to provide consistent GEO retrieved cloud properties and derived broadband fluxes. These fluxes are then carefully normalized against the well-calibrated CERES fluxes to ensure climate quality fluxes, free of GEO artifacts. With the upcoming release of Edition3 products, CERES has just recalibrated all the CERES instruments to ensure that both Terra and Aqua fluxes are on the same radiometric scale and the removal of all known instrument trends. CERES will also recalibrate all GEO satellites using the entire GEO time record. CERES employs collocated, coincident ray-matched GEO/MODIS radiances as its primary technique, calibrating GEO radiances beginning in the year 2000. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. CERES uses deep convective clouds and invariant desert sites to validate the primary technique. All three methods can assess the stability of the GEO visible instrument. Examples of the CERES GEO calibration techniques and validation efforts will be shown at the conference. Special emphasis will be given to the newly incorporated desert site methodology.

R. Bhatt↗

TPSAS-NF1676L-10863-DND

One important aspect of successful climate monitoring is satellite calibration. There is at least a 25-year of operational geostationary (GEO) record available for climate studies, if properly calibrated. The Global Space-based Inter-Calibration System (GSICS) project is another effort to provide the climate community consistent calibration across multiple platforms. Also, the Clouds and the Earth's Radiant Energy System (CERES) project, provides consistent GEO retrieved cloud properties and derived broadband fluxes across multiple platforms. This year GSICS is focusing on geostationary visible channel calibration. The GSICS strategy is to use multiple approaches, such as cross-calibrating the GEO radiances against MODIS as a reference, deep convective clouds as bright stable targets, deserts, sun-glint, stars, moon and other model based calibration methods. Each of these methods is independent of each other and can assess the stability of the GEO visible instrument with differing uncertainties. This study focuses on the inter-calibration of the GEO radiances against MODIS as a reference by using collocated, and coincident ray-matched radiances. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. This presentation will focus on the technique, some error analysis, comparisons with other methods, and an approach to inter-calibrate historical GEOs before MODIS.

D R Doelling↗

Three years of observations from the International Space Station (ISS) by the Stratospheric Aerosol and Gas Experiment III (SAGE III/ISS)

After completion of the robot installation on the International Space Station (ISS) in early March 2017 as an external hosted science payload, the Stratospheric Aerosol and Gas Experiment (SAGE) III became the newest member to the family of space-based solar occultation instruments operated by NASA to investigate the Earth’s upper atmosphere since the late 1970s. One of three identical instruments, the SAGE III/ISS mission was revived in the early 2010s with a primary objective to monitor the vertical distribution of aerosol, ozone and other trace gases to enhance understanding of ozone recovery and climate change processes in the upper atmosphere. Presented here is the mission architecture, its implementation, and data produced by SAGE III/ISS, including their precision and coverage. The 51.6-degree inclined orbit of the ISS is well-suited for solar occultation and provides near-global observations on a monthly basis with coverage of low and mid-latitudes similar to that of the SAGE II mission, which operated over two decades. The nominal science products, derived from sampling spectra covering 290nm to 1030nm and a photo-diode near 1550 nm, include high resolution vertical profiles of ozone, nitrogen dioxide and water vapor, along with multi-wavelength aerosol extinction. Although in the visible portion of the spectrum the brightness of the Sun is a million times that of the full Moon, the SAGE III instrument design covers this large dynamic range, performing lunar occultations on a routine basis to augment the solar products. The standard lunar products include ozone and nitrogen trioxide. Routine observations began June 2017 and continue to the present. This has enabled observations of significant perturbations of the stratosphere induced by three different wildfire events (two of which were record setting), four volcanic eruptions and two changes of the Quasi-Biennial Oscillation (QBO) phase, as represented in the standard data products.

ozone↗

Radiometric approach for the detection of picophytoplankton assemblages across oceanic fronts

Cell abundances of Prochlorococcus, Synechococcus, and autotrophic picoeukaryotes were estimated in surface waters using principal component analysis (PCA) of hyperspectral and multispectral remote-sensing reflectance data. This involved the development of models that employed multilinear correlations between cell abundances across the Atlantic Ocean and a combination of PCA scores and sea surface temperatures. The models retrieve high Prochlorococcus abundances in the Equatorial Convergence Zone and show their numerical dominance in oceanic gyres, with decreases in Prochlorococcus abundances towards temperate waters where Synechococcus flourishes, and an emergence of picoeukaryotes in temperate waters. Fine-scale in-situ sampling across ocean fronts provided a large dynamic range of measurements for the training dataset, which resulted in the successful detection of fine-scale Synechococcus patches. Satellite implementation of the models showed good performance (R(exp 2) > 0.50) when validated against in-situ data from six Atlantic Meridional Transect cruises. The improved relative performance of the hyperspectral models highlights the importance of future high spectral resolution satellite instruments, such as the NASA PACE mission’s Ocean Color Instrument, to extend our spatiotemporal knowledge about ecologically relevant phytoplankton assemblages.

Priscila Kienteca Lange↗

A compact 600 GHz electronically tunable vector measurement system for submillimeter wave imaging

A compact submillimeter wave transmission/reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 100 dB (60 dB typical), and typical phase noise is less than +/- 1°. By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near realtime imaging capability using only a single pixel

Siegel, Peter H.↗

Active Optics and Coronography with the Hubble Space Telescope

In the field of planet and proto-planetary disk detection, achieving high angular resolution and high dynamic range is a necessity. Ground images are blurred by atmospheric turbulence and therefore adaptive optics is necessary to achieve sub-arcsecond images.

atmospheric↗

CMOS Active Pixel Image Sensor

A new CMOS active pixel image sensor is reported. The sensor uses a 2.0mue double-poly, double-metal foundry CMOS process and is realized as a 28 x 28 array of 40 mue x 40 mue pixels. The Sensor features TTL compatible voltages, low noise and large dynamic range, and will be useful in machine vision and smart sensor applications.

CMOS↗

Characterization of the Teledyne CHROMA HgCdTe Detector for Imaging Spectrometers

Imaging spectroscopy places high demands upon detector performance. The dynamic range, linearity, and sensitivity must be maintained at high frame rates, and artifacts must be minimized across large focal plane array (FPA) formats. In this contribution, we discuss the Teledyne CHROMA HgCdTe FPA in the context of imaging spectrometer applications. The FPA was characterized in a laboratory thermal-vacuum chamber that allowed the read noise, dark current, well capacity, linearity, and crosstalk to be measured. Results are presented across a range of operating temperatures and pixel clock rates. Additionally, the outcomes of radiation testing to 100 krad TID are discussed. The results of these characterizations are critical to the designs and performance predictions of future imaging spectrometers utilizing the HgCdTe CHROMA FPA.

Green, Robert↗

Global navigation satellite system reflectometry (GNSS-R) algorithms for wetland observations

It is important to closely monitor the state of the world’s wetlands, as climate change and human encroachment in a rapid global urbanization trend threaten to cause large-scale wetland collapse. Because wetlands are often difficult to observe in situ, remote sensing is the only viable way to map wetland extent globally. However, current remote sensing methods suffer limitations in capturing wetland extent, and more importantly, wetland dynamics at appropriate spatial and temporal scales. GNSSReflectometry could help fill the current observation gap, as experimental data show that ground-reflected GNSS signals are very sensitive to changes in inundated areas. Furthermore, because this technique only requires a custom developed receiver and antenna system, a constellation of such instruments can potentially be launched at relatively low cost, providing global observations at sub-daily intervals. One challenge remains, however, which is quantitatively formulating the geophysical product of reflections over the land surface in various states of inundation. Here, we use a novel reflection dataset, derived from the SMAP radar receiver, to elucidate the sensitivity of reflections to small land surface features and their seasonal variations. Additionally, we quantify the dynamic range of reflections over both open and closed wetlands, and suggest an algorithm for wetland type classification.

UNKNOWN↗

A strongly changing accretion morphology during the outburst decay of the neutron star x-ray binary 4U 1608-52

It is commonly assumed that the properties and geometry of the accretion flow in transient low-mass X-ray binaries (LMXBs) significantly change when the X-ray luminosity decays below ∼10−2 of the Eddington limit (LEdd). However, there are few observational cases where the evolution of the accretion flow is tracked in a single X-ray binary over a wide dynamic range. In this work, we use NuSTAR and NICER observations obtained during the 2018 accretion outburst of the neutron star LMXB 4U 1608−52, to study changes in the reflection spectrum. We find that the broad Fe–Kα line and Compton hump, clearly seen during the peak of the outburst when the X-ray luminosity is ∼1037 erg s−1 (∼0.05 LEdd), disappear during the decay of the outburst when the source luminosity drops to ∼4.5 × 1035 erg s−1 (∼0.002 LEdd). We show that this non-detection of the reflection features cannot be explained by the lower signal-to-noise ratio at lower flux, but is instead caused by physical changes in the accretion flow. Simulating synthetic NuSTAR observations on a grid of inner disc radius, disc ionization, and reflection fraction, we find that the disappearance of the reflection features can be explained by either increased disc ionization (log ξ  4.1) or a much decreased reflection fraction. A changing disc truncation alone, however, cannot account for the lack of reprocessed Fe–Kα emission. The required increase in ionization parameter could occur if the inner accretion flow evaporates from a thin disc into a geometrically thicker flow, such as the commonly assumed formation of a radiatively inefficient accretion flow at lower mass accretion rates.

J. van den Eijnden↗

Sky-Scanning Sun-Tracking Airborne Radiometer (3STAR): Instrument Design, Flight Testing, and Tracking Performance

The Sky-Scanning, Sun-Tracking Airborne Radiometer (3STAR) adapts commercial radiometer technology developed for the ocean color research community to airborne measurement of spectrally resolved solar irradiance and sky radiance. These atmospheric observations are used to derive aerosol optical depth (AOD), supporting localized AOD inputs for atmospheric correction of satellite and airborne data over terrestrial and aquatic (including optically dark) targets. The ability to regionally “tune” atmospheric correction schemes with relevant spatial AOD supports constraining atmospheric correction of remote sensing reflectance. Very wide dynamic range has been achieved for multi-channel band-pass-filter-radiometers originally designed for deployment into the water column. By actively tracking and directly pointing to the Sun, the light attenuation by aerosol particles in the atmospheric column can be quantified. These measurements improve knowledge of atmospheric constituents and the atmospheric corrections required to improve remote sensing capabilities for interpreting reflectance measurements from the Earth surface. 3STAR incorporates a custom Sun-tracking/sky-scanning pointing head, a Sun-tracking camera, and a commercially available, cylindrical, 19-channel radiometer tube assembly. An accurate and responsive mount and tracking system has been developed and certified to NASA and Naval Air Systems Command (NAVAIR) airworthiness standards for deployment into the aircraft slipstream. Ground and flight testing indicate typical tracking errors of less than 0.1 degrees, well within the field of view of the radiometer as required to minimize measurement uncertainty from alignment error. Preliminary AOD measurements compare to within 0.013 with 15 measurements from an Aerosol Robotic Network (AERONET) Cimel instrument at 500 nm wavelength and low solar angle.

Atmosphere↗

Fe xvii 2p–3s Line Ratio Diagnostic of Shock Formation Radius in O Stars

The 2p–3s lines of Fe xvii in the X-ray spectrum of the O-type star ζ Puppis exhibit an anomalous (3G + M2)/(3F) line ratio of ∼1.4, in comparison with ∼2.4 for almost all other collisionally excited astrophysical spectra. Based on the work of Mauche et al., we conjectured that the strong UV field of ζ Puppis produces the observed ratio by depopulation of metastable 3s excited states, and that the ratio can potentially be used as an independent diagnostic of plasma formation radius. We used the Flexible Atomic Code collisional-radiative model to model the effect of UV photoexcitation from O stars on the Fe xvii lines. We compared our model calculations to archival spectra of coronal and hot stars from the Chandra HETGS and XMM-Newton RGS to benchmark our calculations for various electron densities and UV field intensities. Our calculations show that UV photoexcitation does not produce a sufficiently large dynamic range in the 3F / (3F + 3G + M2) fraction to explain the difference in the observed ratio between coronal stars and ζ Pup. Thus, this effect likely cannot explain the observed line ratio of ζ Pup, and its origin is still unexplained.

Gabriel J. Grell↗

Progressive TDI Measurements with the PACE OCI ETU

The Plankton Aerosol Cloud ocean Ecosystem (PACE) Ocean Color Instrument (OCI) has completed the ground test program for its engineering unit (ETU) and testing of the flight unit will begin in the near future. OCIis a grating spectrometer with hyperspectral coverage from about 340 nm to 885 nm with 9 additional filtered channels in the SWIR. Two CCDs are used as detectors for the hyperspectral channels. One important operating mode of the CCDs on OCI is progressive time delay integration (or PTDI). In this mode, the charge in the CCD can be held for multiples of the nominal integration times. A series of these measurements can be made with progressively increasing multiples of the nominal integration time as the instrument scans across a uniform source. Ground testing with this operating mode on OCI ETU has shown promising results. This work will present measurements taken with the PTDI mode and the analysis of OCI ETU linearity and dynamic range

PACE↗