At least 955 records · Page 53

Development of the International Space Station Fine Water Mist Portable Fire Extinguisher

The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.

Rodriquez, Branelle↗

K-1435 Wastewater Treatment System for the Toxic Substances Control Act Incinerator Wastewater at the East Tennessee Technology Park, Oak Ridge, TN

This paper will discuss the design and performance of a wastewater treatment system installed to support the operation of a hazardous waste incinerator. The Oak Ridge Toxic Substances Control Act Incinerator (TSCAI), located at the East Tennessee Technology Park (ETTP), is designed and permitted to treat Resource Conservation and Recovery Act (RCRA) wastes including characteristic and listed wastes and polychlorinated biphenyl (PCB)-contaminated mixed waste. The incinerator process generates acidic gases and particulates which consist of salts, metals, and radionuclides. These off-gases from the incinerator are treated with a wet off-gas scrubber system. The recirculated water is continuously purged (blow down), resulting in a wastewater to be treated. Additional water sources are also collected on the site for treatment, including storm water that infiltrates into diked areas and fire water from the incinerator's suppression system. To meet regulatory requirements for discharge, a wastewater treatment system (WWTS) was designed, constructed, and operated to treat these water sources. The WWTS was designed to provide for periodic fluctuation of contaminant concentrations due to various feed streams to the incinerator. Blow down consists of total suspended solids (TSS) and total dissolved solids (TDS), encompassing metals, radionuclide contamination and trace organics. The system design flow rate range is 7.95 to 17 cubic meters per hour (m3/hr) (35 to 75 gallons per minute; gpm). The system is designed with redundancy to minimize time off-line and to reduce impacts to the TSCAI operations. A novel treatment system uses several unit operations, including chemical feed systems, two-stage chemical reaction treatment, micro-filtration, sludge storage and dewatering, neutralization, granular activated carbon, effluent neutralization, and a complete programmable logic controller (PLC) and human-machine interface (HMI) control system. To meet the space requirements and to provide portability of the WWTS to other applications, the system was installed in three, over-the-road semi trailers, and interconnected with piping and power. Trailers were oriented on a small site footprint to facilitate ease of installation. A remote sump pump skid was provided to convey water from two holding sumps adjacent to the treatment process. An accumulation tank and pump were also provided to receive miscellaneous wastewaters for treatment if they meet the waste acceptance criteria. The paper will include details of the technology used in the design, the requirements for compliance, and the initial performance demonstration and jar testing results. The WWTS successfully allowed for highly efficient, high-volume treatment with compliant discharge to off-site surface water. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Species of Fire Discovered: Fingering Flamelets Form a Dynamic Population

Poets and artists have long used fire as a metaphor for life. At the NASA Glenn Research Center, recent experiments in a subcritical Rayleigh number flow channel demonstrated that this analogy holds up surprisingly well when tools developed to characterize a biological population are applied to a class of fire that occurs in near-extinction, weakly convective environments (such as microgravity) or in vertically confined spaces (such as our apparatus). Under these conditions, the flame breaks into numerous 'flamelets" that form a Turing-type reaction-diffusion fingering pattern as they spread across the fuel. It is standard practice on U.S. spacecraft for the astronaut crew to turn off the ventilation to help extinguish a fire, both to eliminate the fresh oxygen supply and to reduce the distribution of the smoke. When crew members think that the fire is fully extinguished, they reactivate the ventilation system to clear the smoke. However, some flamelets can survive, and our experiments have demonstrated that flamelets quickly grow into a large fire when ventilation increases.

Olson, Sandra L.↗

Application of OpenFOAM to Plume Impingement in Space Environments

After 30 years of continuous human presence in low-earth orbit, NASA is returning to the moon and eventually will go to Mars. Travelling beyond low earth orbit requires NASA to learn how humans can live in Deep Space environments – beyond the protection of Earth’s magnetosphere and at distances from Earth that prevent a quick return in case of trouble. To this end, NASA is constructing the Lunar Gateway, an ISS-like space station to be put in orbit around the moon to act as a home base for Lunar exploration for NASA astronauts. The Gateway Lunar outpost will be built incrementally, via modules which will arrive at separate times and dock to the existing structure. The incremental addition of Gateway modules, and the docking of visiting vehicles, is achieved via a sequence of firings from the approaching body’s onboard reaction control system (RCS) thrusters to achieve the required approach trajectory. The typical hypergolic chemical RCS thrusters work by firing hot gases to produce adverse thrust and the needed change in velocity to safely finish the docking process. The exhaust gas from the RCS thrusters form plumes that expand into the vacuum of space and can impinge onto the outer surfaces of the Lunar Gateway, causing unwanted forces and moments, heat loads, sediment deposition, and in extreme cases, even surface erosion - all mechanisms that can damage the Lunar Gateway and must be minimized. Both permanent and visiting modules will have this RCS thruster exhaust impingement problem. This research aims to establish existing OpenFOAM solvers as a methodology for improving simulation techniques of rocket exhaust plume impingement in space environments. The flow structure of a plume in a space environment is complex; a plume that originates from a hypergolic chemical RCS thruster and expands into a vacuum will experience several regimes of rarefication. This range includes the continuum flow in the rocket nozzle through the fully rarefied free molecular flow further from the nozzle. The flow physics is different at these two extremes, and as such, the simulation approach for plumes is generally divided into a traditional computational fluid dynamics (CFD) simulation in and near the nozzle which is coupled to a subsequent direct simulation Monte Carlo (DSMC) simulation. At this time, the scope of this research is developing, verifying, and validating a method using existing solvers in the OpenFOAM framework for performing coupled CFD/DSMC calculations to determine the extent of plume impingement loading on generic space structures. This presentation will detail code-to-code comparisons between the hyStrath dsmcFoam+ solver, developed using OpenFOAM and available as open-source, and NASA’s in-house DSMC Analysis Code (DAC). Comparisons to several open-source publication findings using DAC [3,4] are presented, and advantages of using an OpenFOAM based solver are also discussed. The presentation concludes with a discussion of future work, and a plan for coupling the dsmcFoam+ solver with CFD simulations of chemical rocket engines for unified coupled plume simulation.

DSMC↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater Part 1: Southern and South Central Climate Zones

Commercial hot water heating accounts for approximately 0.78 Quads of primary energy use with 0.44 Quads of this amount from natural gas fired heaters. An ammonia-water based commercial absorption system, if fully deployed, could achieve a high level of savings, much higher than would be possible by conversion to the high efficiency nonheat-pump gas fired alternatives. In comparison with air source electric heat pumps, the absorption system is able to maintain higher coefficients of performance in colder climates. The ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. A thermodynamic model of a single effect ammonia-water absorption system for commercial space and water heating was developed, and its performance was investigated for a range of ambient and return water temperatures. This allowed for the development of a performance map which was then used in a building energy modeling software. Modeling of two commercial water heating systems was performed; one using an absorption heat pump and another using a condensing gas storage system. The energy and financial savings were investigated for a range of locations and climate zones in the southern and south central United States. A follow up paper will analyze northern and north/central regions. Results showed that the system using an absorption heat pump offers significant savings.

Geoghegan, Patrick J↗

Microalgae Commodities from Coal-Fired Power Plant Flue Gas CO 2 (Draft Final Report, October 1, 2015 to June 30, 2018)

The Orlando Utilities Commission (OUC) operates an approximately 900-MWe coal fired-power plant at Stanton Energy Center (SEC), which was the site for this project to develop an integrated process for microalgae utilization of flue gas CO 2 for the production of biofuels and animal feeds. Microalgae have both potentially high yields (tons biomass/acre-year) and can be used for biofuels or high value animal feeds. The high biomass yields of microalgae cultures allows efficient use of land and water resources. They can also use wastewaters, recycle fertilizers, and have lower overall greenhouse gas emissions than conventional biofuels or animal feeds. However, many technical issues and technology gaps related to large-scale algae biomass production still must be resolved before such a process can be scaled-up. In this project, techno-economic analyses (TEAs) and life cycle assessments (LCAs) were carried out, projecting the costs and impacts of large-scale algae biomass cultivation for production of biofuels and animal feeds using OUC-SEC flue gas CO 2 . In addition, 3.5-m 2 (~ 40-ft 2 ) experimental raceway ponds were used for the cultivation of microalgae at OUC-SEC and also at the University of Florida. A large-scale algae farm was designed for a 1,300-acre site (~500-ha) located near the OUC-SEC plant, consisting of 400 hectares (1,000 acres) of paddle wheel mixed raceway ponds (each 4 ha), receiving flue gas piped approximately 3 km (2 miles) from the SEC plant. In the first year of this project (Budget Period 1, BP1), the TEA and LCA studies focused on the production of biogas produced from algae biomass and its use to replace coal at the power plant. However, due to the resulting very high cost of CO 2 mitigation, the process was modified to produce compressed natural gas (‘renewable natural gas’, RNG) for transportation fuel from the biogas, in conjunction with wastewater treatment by the algae cultures. During Budget Period 2 (BP2), the TEA and LCA studies focused on the production of animal feeds by the algae farm, using fresh water and agricultural fertilizers. In this case, CO 2 mitigation costs would be entirely covered if the algal biomass could be sold at between a two to three-fold premium above soybean feed, based on a higher nutritional value for the algal biomass. In support of the above analyses, microalgae cultivation experiments were carried out for over two years during this project in small 3.5-m 2 ponds at both SEC and the University of Florida. The most important results were the demonstration at SEC of the cultivation, on flue gas CO 2 , of filamentous algae biomass, which can be harvested at much lower cost than processes required for the colloidal algae species, as currently used by almost all algal mass culture biofuels and animal feeds projects. The yield of biogas production from the algal biomass was investigated by the University of Florida, and the value of the algal biomass as animal feed was projected based on biochemical analysis of the SEC ad UF biomasses. The conclusion from TEA/LCA carried out for the biogas case in BP1 was that a 400-ha algae system producing biomethane for co-firing at OUC-SEC could generate 27,500 MWh/yr of renewable power, offsetting 28,400 Mg CO 2eq /yr, which amounted to less than 1% of the CO 2 emitted by the SEC plant. (Mg = metric ton = 1.10 short tons). The overall cost was projected at $820/Mg of CO 2eq reduction, making this process unfeasible under any possible scenario. More favorable economics were projected when the biogas was converted to higher value transportation fuel, RNG, which also would benefit from renewable fuel (RINs) and possibly other credits. However, only by combining RNG production with municipal wastewater treatment in the algal ponds would CO 2 utilization result in no net cost or even be economically beneficial (i.e., generate income to the power plant). However, in that case the amount of CO 2 utilization would be even lower than that in the biogas case, because a large fraction of the carbon required would be supplied from the wastewater and CO 2 recovered during biogas upgrading to RNG. In brief, use of power plant CO 2 emissions for algal biofuels production was not favorable, even with optimistic assumptions about biomass productivity and biogas yields. For the animal feed case, developed during BP2, algal biomass would replace soybean feeds. The same scale 400-ha algal production plant was projected to produce 26,280 Mg per year of animal feed with a utilization of 45,300 Mg flue gas CO 2 taken up by the algal biomass. However, the process would result in a projected reduction of 112,500 Mg CO 2eq emissions per year, or roughly 1.9% of OUC-SEC emissions, mainly due to the large CO 2eq emissions from conventional soybean production. A major factor in this analysis were greenhouse gas emissions from land use changes. The cost of CO 2 utilization was projected at $116/Mg if the biomass sold for the same price as soybean meal, but if sold as a premium feed (e.g., based on high omega-3 fatty acid and carotenoid content), the power plant could actually charge for the CO 2 utilized. These economic projections are sensitive to assumptions underlying the TEA and LCA models, including biomass composition and the financial models used to project CAPEX and OPEX. Further development of an algal animal feed production using coal-fired power plant flue gas CO 2 is recommended based on the TEA and LCA, as well as experimental results. The required research and development is detailed in a technology gap analysis (Section 11), which focuses on the demonstrations of the cultivation of higher value filamentous algal biomass at OUC-SEC.

01 COAL, LIGNITE, AND PEAT↗

Experiment D003: Mass determination

The accuracy of a direct contact method with a spacecraft to determine the mass of an orbiting object was studied. The precedure involved acceleration of the Gemini Agena target vehicle by the use of the Gemini 9 spacecraft propulsion system. The target vehicle mass was calculated from the resultant acceleration, updated Gemini spacecraft mass, and calibrated thrust levels of the air-firing thrusters of the orbital attitude and maneuver system of the Gemini spacecraft.

Hamborsky, R. J.↗

Techno Economic Analysis of an LGFCS MWE Class SOFCT System (Final Scientific/Technical Report)

The objective of this project is to perform a range of technical, cost and economic analyses of a MWscale natural gas fired Solid Oxide Fuel Cell (SOFC) distributed power generation system design. The information generated will provide evidence of the tracking of technology and manufacturing readiness supportive of Technology Readiness Level 7 (TRL7) system testing in the 2022 timeframe that meets the Department of Energy’s (DOE) targets for cost (<$6000/kW) and durability (<0.5% power degradation/1000 hours).

20 FOSSIL-FUELED POWER PLANTS↗

Radiative Forcing Due to Enhancements in Tropospheric Ozone and Carbonaceous Aerosols Caused by Asian Fires During Spring 2008

Simulations of tropospheric ozone and carbonaceous aerosol distributions, conducted with the Real-time Air Quality Modeling System (RAQMS), are used to study the effects of major outbreaks of fires that occurred in three regions of Asia, namely Thailand, Kazakhstan, and Siberia, during spring 2008. RAQMS is a global scale meteorological and chemical modeling system. Results from these simulations, averaged over April 2008, indicate that tropospheric ozone column increases by more than 10 Dobson units (DU) near the Thailand region, and by lesser amounts in the other regions due to the fires. Widespread increases in the optical depths of organic and black carbon aerosols are also noted. We have used an off-line radiative transfer model to evaluate the direct radiative forcing due to the fire-induced changes in atmospheric composition. For clear sky, the monthly averaged radiative forcing at the top of the atmosphere (TOA) is mostly negative with peak values less than -12 W/sq m occurring near the fire regions. The negative forcing represents the increased outgoing shortwave radiation caused by scattering due to carbonaceous aerosols. At high latitudes, the radiative forcing is positive due to the presence of absorbing aerosols over regions of high surface albedo. Regions of positive forcing at TOA are more pronounced under total sky conditions. The monthly averaged radiative forcing at the surface is mostly negative, and peak values of less than -30 W/sq m occur near the fire regions. Persistently large negative forcing at the surface could alter the surface energy budget and potentially weaken the hydrological cycle.

Natarajan, Murali↗

LANL Investigation Report: Magnet Fire Event at TA-53, Line D South

On May 21, 2014, at approximately 2350, an electric magnet fire occurred in the Line D South area of Technical Area 53. Smoke detectors in the supply and return ventilation system ducts activated, sending alarms to the Emergency Operations Support Center (EOSC). Approximately 7 minutes later, a single fire suppression sprinkler actuated. Upon receipt of multiple flow alarms, the Los Alamos Fire Department (LAFD) was dispatched. These first responders concluded this was a false alarm and left the scene prior to the arrival of LANL, or TA-53 personnel. Because of the continued flow of the fire suppression water through the actuated sprinkler, local Radioactive Liquid Waste (RLW) tanks later alarmed on high-level. Further response by the Utilities and Infrastructure (UI) Facility Supervisor and TA-53 facility personnel was focused on stopping the flow of water. These personnel believed the sprinkler actuation and subsequent RLW high level alarms were due to a failed sprinkler head (not an actual fire event).

99 GENERAL AND MISCELLANEOUS↗

Firefighting Module

NASA and the U.S. Coast Guard are working jointly to develop a helicopter transportable firefighting module that can shave precious minutes in combating shipboard or harbor fires. The program was undertaken in 1975, after a series of disastrous fires on oil tankers indicated a need for a lightweight, self-contained system that could be moved quickly to the scene of a fire. A prototype module was delivered to the Coast Guard last year and service testing is under way. The compact module weighs little more than a ton but it contains everything needed to fight a fire. The key component is a high output pump, which delivers up to 2,000 gallons of sea water a minute; the pump can be brought up to maximum output in only one minute after turning on the power source, a small Allison gas turbine engine. The module also contains hose, a foam nozzle and a spray nozzle, three sets of protective clothing for firefighters, and fuel for three hours operation. Designed to be assembled without special tools, the module can be set up for operation in less than 20 minutes.

Source record↗

International Space Station United States Laboratory Module Water Recovery Management Subsystem Verification from Flight 5A to Stage ULF2

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system comprises of seven subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), Vacuum System (VS), Water Recovery and Management (WRM), and Waste Management (WM). This paper provides a summary of the nominal operation of the United States (U.S.) Laboratory Module WRM design and detailed element methodologies utilized during the Qualification phase of the U.S. Laboratory Module prior to launch and the Qualification of all of the modification kits added to it from Flight 5A up and including Stage ULF2.

Williams, David E.↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture

GE Global Research is developing technology to remove carbon dioxide (CO 2) from the flue gas of coal-fired powerplants. A mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) and triethylene glycol (TEG) is the preferred CO2-capture solvent. GE Global Research was contracted by the Department of Energy to test a pilot-scale continuous CO2 absorption/desorption system using a GAP-1m/TEG mixture as the solvent. As part of that effort, an Environmental, Health, and Safety (EH&S) assessment for a CO2-capture system for a 550 MW coal-fired powerplant was conducted. Five components of the solvent, CAS#2469-55-8 (GAP-0), CAS#106214-84-0 (GAP-1-4), TEG, and methanol and xylene (minor contaminants from the aminosilicone) are included in this assessment. One by-product, GAP- 1m/SOX salt, and dodecylbenzenesulfonicacid (DDBSA) were also identified foranalysis. An EH&S assessment was also completed for the manufacturing process for the GAP-1m solvent. The chemicals associated with the manufacturing process include methanol, xylene, allyl chloride, potassium cyanate, sodium hydroxide (NaOH), tetramethyldisiloxane (TMDSO), tetramethyl ammonium hydroxide, Karstedt catalyst, octamethylcyclotetrasiloxane (D4), Aliquat 336, methyl carbamate, potassium chloride, trimethylamine, and (3-aminopropyl) dimethyl silanol. The toxicological effects of each component of both the CO2 capture system and the manufacturing process were defined, and control mechanisms necessary to comply with U.S. EH&S regulations are summarized. Engineering and control systems, including environmental abatement, are described for minimizing exposure and release of the chemical components. Proper handling and storage recommendations are made for each chemical to minimize risk to workers and the surrounding community.

01 COAL, LIGNITE, AND PEAT↗

Uranium Attenuated by a Wetland 50 Years after Release into a Stream

: Wetlands have several important roles in the hydrological cycle, including maintaining water quality by removing surface and groundwater contaminants. Over time, the wetlands themselves can become contaminated, posing a secondary environmental threat. The objective of this study was to calculate the inventory of uranium (U) remaining in a wetland 50 years after the Fuel Fabrication Facility on the Savannah River Site located in South Carolina released 43.5 Mg of U into the nearby environment. Over 232 700 gamma spectra and their associated global positioning system (GPS) coordinates were collected and collated into a map of the contaminated land area. Five core samples were also collected that contained U concentrations as high as 14 099 mg/kg (background levels are about 2.7 mg/kg U). The contaminated area was 278 000 m2 , and it contained 36.2 Mg U, about 83% of the U released. About 80% of the U in the wetland was concentrated in a former beaver pond, a 73 000 m2 area (26% of the contaminated area). This contaminated wetland area was almost 2 km from the source, indicating that it comprised unique hydro-biogeochemical properties for immobilizing the released U. To the best of our knowledge, this is the first data-rich study to quantify the long-term effectiveness of a wetland to immobilize inorganic contaminants. Significant environmental changes to the system, such as those associated with hydrology, forest fires, or anthropogenic land use, may alter the complex hydro-biogeochemical interactions necessary for the long-term immobilization of the U.

Contaminant inventory↗

Enabling The Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

Ohio University (OHIO), West Virginia University (WVU), and American Electric Power (AEP) proposed to study and report on the benefits of 5G wireless cellular technologies for coal-fired power plants. The significant advantages, cost savings, and potential of 5G wireless data communications based sensors promised to usher in a new era of reliable, inexpensive, and powerful embedded systems that had not previously been available for coal-fired power plants. The team built upon existing experience with cellular-based systems, power plant water quality sensing, and high temperature sensors developed during past projects. Principal Investigator Wilhelm had been developing cellular-based sensor data systems with a commercial partner for 10 years, pioneering innovative solar-powered devices that began with 2G technology. The lessons and knowledge gained served as a foundation to demonstrate innovations and potential impacts specific to coal fired power plants enabled by 5G technology, along with integration with existing sensors and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Allometric relationships for Quercus gambelii and Robinia neomexicana for biomass estimation following disturbance

Abstract In the southwestern USA, increases in size, frequency, and severity of wildfire are driving the conversion of forests to shrub‐dominated ecosystems. Increases in drought extent and severity, coupled with the way that shrub‐dominated systems are perpetuated by high‐severity fire, predisposes these post‐disturbance landscapes to remain in a non‐forest condition. Consequently, understanding the distribution of aboveground biomass in post‐disturbance, shrub‐dominated ecosystems is central to constraining the uncertainty surrounding how these ecosystems interact with light and water to sequester carbon. Here we present allometric regressions for Quercus gambelii (Gambel oak) and Robinia neomexicana (New Mexico locust), two species that dominate post‐fire landscapes in the southwestern USA. Our allometric regressions are designed to be driven by either field plot or high‐resolution remote sensing data, using either shrub area or shrub volume to estimate biomass.

Krofcheck, Dan J.↗