Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 955 records · Page 53

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

TEM Study of Fracturing in Spherical and Plate-like LiFePO4Particles

An investigation of fracturing in LiFePO{sub 4} particles as a function of the particle morphology and history is presented. Two types of samples, one subjected to electrochemical cycling and another to chemical delithiation are compared. We observe the formation of micro fractures parallel to low indexed lattice planes in both samples. The fracture surfaces are predominantly parallel to (100) planes in the chemically delithiated powder and (100) and (010) planes in the electrochemically cycled powder. A consideration of the threshold stresses for dislocation glide shows that particle geometry plays an important role in the observed behavior.

25 ENERGY STORAGE↗

Mechanics of nanoscale metallic multilayers: from atomic-scale to micro-scale

Layered composites of Cu/Nb with incoherent interfaces achieve very high strength levels. Interfaces play a crucial role in materials strength by acting as barriers to slip. Atomistic models of Cu/Nb bilayers are used to explore the origins of this resistance. The models clearly show that dislocations near an interface experience an attraction toward the interface. This attraction is caused by shear of the interface induced by the stress field of the dislocation. More importantly, atomistic simulations also reveal that interfacial dislocations easily move in interfaces by both glide and climb. Integrating these findings into a micro-scale model, we develop a three-dimensional crystal elastic-plastic model to describe the mechanical behavior of nanoscale metallic multi layers.

36 MATERIALS SCIENCE↗

Complete genome sequence of Isosphaera pallida type strain (IS1B T )

Isosphaera pallida (ex Woronichin 1927) Giovannoni et al. 1995 is the type species of the genus Isosphaera. The species is of interest because it was the first heterotrophic bacterium known to be phototactic, and it occupies an isolated phylogenetic position within the Planctomycetaceae. Here we describe the features of this organism, together with the complete genome sequence and annotation. This is the first complete genome sequence of a member of the genus Isosphaera and the third of a member of the family Planctomycetaceae. The 5,472,964 bp long chromosome and the 56,340 bp long plasmid with a total of 3,763 protein-coding and 60 RNA genes are part of the Genomic Encyclopedia of Bacteria and Archaea project.

59 BASIC BIOLOGICAL SCIENCES↗

Complete genome sequence of Cellulophaga algicola type strain (IC166 T )

Cellulophaga algicola Bowman 2000 belongs to the family Flavobacteriaceae within the phylum 'Bacteroidetes' and was isolated from Melosira collected from the Eastern Antarctic coastal zone. The species is of interest because its members produce a wide range of extracellular enzymes capable of degrading proteins and polysaccharides with temperature optima of 20-30°C. This is the first completed genome sequence of a member of the genus Cellulophaga. The 4,888,353 bp long genome with its 4,285 protein-coding and 62 RNA genes consists of one circular chromosome and is a part of the Genomic Encyclopedia of Bacteria and Archaea project.

59 BASIC BIOLOGICAL SCIENCES↗

Near-isothermal-isobaric compressed gas energy storage

In this paper, the effectiveness of storing energy by compressing and expanding a condensable gas is evaluated. A high efficiency energy storage system, which stores energy by compressing/expanding gas (air) using a liquid (water) piston has been recently introduced and extensively studied. With the use of the liquid piston, the inefficient gas turbomachines used in conventional gas compression/expansion systems are replaced with high efficiency hydraulic machines. Utilizing heat transfer techniques and replacing the non-condensable air with a condensable gas (i.e. CO 2 , synthetic refrigerants, hydrocarbon refrigerants, etc.) have been proposed as methods to improve energy density and roundtrip efficiency of such systems, leading to near isothermal and near isobaric charge/discharge processes. In order to investigate the effectiveness of the proposed concept, a miniature lab-scale experimental setup was designed and built to investigate the compression/expansion characteristics and energy storage efficiency of a system utilizing R134a as the energy storage (primary) working fluid, and mineral refrigerant oil as the liquid piston (secondary) working fluid. Several tests are carried out to quantify energy storage efficiency and energy density. It is found that improving heat transfer rates from/into the storage fluid results in increased efficiency and energy density. A heat-transfer enhancement strategy to achieve near isothermal, isobaric expansion and compression is proposed and investigated experimentally. Some results are generalized and presented in non-dimensional form which can be applied to describe and/or design scaled-up systems. Lastly, a potential working fluid for a scaled-up system is discussed.

25 ENERGY STORAGE↗

Anatomic and Pathologic Variability During Radiotherapy for a Hybrid Active Breath-Hold Gating Technique

Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroid position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% {+-} 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course

Purpose: To investigate the impact of primary tumor and involved lymph node (LN) geometry (centroid, shape, volume) on internal target volume (ITV) throughout treatment for locally advanced non-small cell lung cancer using weekly four-dimensional computed tomography (4DCT). Methods and Materials: Eleven patients with advanced non-small cell lung cancer were treated using image-guided radiotherapy with acquisition of weekly 10-Phase 4DCTs (n = 51). Initial ITV was based on planning 4DCT. Master-ITV incorporated target geometry across the entire treatment (all 4DCTs). Geographic miss was defined as the % Master-ITV positioned outside of the initial planning ITV after registration is complete. Registration strategies considered were bony (B), primary tumor soft tissue alone (T), and registration based on primary tumor and involved LNs (T{sub L}N). Results: The % geographic miss for the primary tumor, mediastinal, and hilar lymph nodes based on each registration strategy were (1) B: 30%, 30%, 30%; (2) T: 21%, 40%, 36%; and (3) T{sub L}N: 26%, 26%, 27%. Mean geographic expansions to encompass 100% of the primary tumor and involved LNs were 1.2 {+-} 0.7 cm and 0.8 {+-} 0.3 cm, respectively, for B and T{sub L}N. Primary and involved LN expansions were 0.7 {+-} 0.5 cm and 1.1 {+-} 0.5 cm for T. Conclusion: T is best for solitary targets. When treatments include primary tumor and LNs, B and T{sub L}N provide more comprehensive geographic coverage. We have identified high % geographic miss when considering multiple registration strategies. The dosimetric implications are the subject of future study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of a Novel Algorithm For Generating Synthetic CT Images From Magnetic Resonance Imaging Data Sets for Prostate Cancer Radiation Therapy

Purpose: To describe and evaluate a method for generating synthetic computed tomography (synCT) images from magnetic resonance simulation (MR-SIM) data for accurate digitally reconstructed radiograph (DRR) generation and dose calculations in prostate cancer radiation therapy. Methods and Materials: A retrospective evaluation was performed in 9 prostate cancer patients who had undergone MR-SIM in addition to CT simulation (CT-SIM). MR-SIM data were used to generate synCT images by using a novel, voxel-based weighted summation approach. A subset of patients was used for weight optimization, and the number of patients to use during optimization was determined. Hounsfield unit (HU) differences between CT-SIM and synCT images were analyzed via mean absolute error (MAE). Original, CT-based treatment plans were mapped onto synCTs. DRRs were generated, and agreement between CT and synCT-generated DRRs was evaluated via Dice similarity coefficient (DSC). Dose was recalculated, and dose-volume metrics and gamma analysis were used to evaluate resulting treatment plans. Results: Full field-of-view synCT MAE across all patients was 74.3 ± 10.9 HU with differences from CTs of 2.0 ± 8.1 HU and 11.9 ± 46.7 HU for soft tissue structures (prostate, bladder, and rectum) and femoral bones, respectively. Calculated DSCs for anterior-posterior and lateral DRRs were 0.90 ± 0.04 and 0.92 ± 0.05, respectively. Differences in D99%, mean dose, and maximum dose to the clinical target volume from CT-SIM dose calculations were 0.75% ± 0.35%, 0.63% ± 0.34%, and 0.54% ± 0.33%, respectively, for synCT-generated plans. Gamma analysis (2%/2 mm dose difference/distance to agreement) revealed pass rates of 99.9% ± 0.1% (range, 99.7%-100%). Conclusion: Generated synCTs enabled accurate DRR generation and dose computation for prostate MR-only simulation. Dose recalculated on synCTs agreed well with original planning distributions. Further validation using a larger patient cohort is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 × 1.5 × 3.0 mm{sup 3} could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer

Purpose: The development of synthetic computed tomography (CT) (synCT) derived from magnetic resonance (MR) images supports MR-only treatment planning. We evaluated the accuracy of synCT and synCT-generated digitally reconstructed radiographs (DRRs) relative to CT and determined their performance for image guided radiation therapy (IGRT). Methods and Materials: Magnetic resonance simulation (MR-SIM) and CT simulation (CT-SIM) images were acquired of an anthropomorphic skull phantom and 12 patient brain cancer cases. SynCTs were generated using fluid attenuation inversion recovery, ultrashort echo time, and Dixon data sets through a voxel-based weighted summation of 5 tissue classifications. The DRRs were generated from the phantom synCT, and geometric fidelity was assessed relative to CT-generated DRRs through bounding box and landmark analysis. An offline retrospective analysis was conducted to register cone beam CTs (n=34) to synCTs and CTs using automated rigid registration in the treatment planning system. Planar MV and KV images (n=37) were rigidly registered to synCT and CT DRRs using an in-house script. Planar and volumetric registration reproducibility was assessed and margin differences were characterized by the van Herk formalism. Results: Bounding box and landmark analysis of phantom synCT DRRs were within 1 mm of CT DRRs. Absolute planar registration shift differences ranged from 0.0 to 0.7 mm for phantom DRRs on all treatment platforms and from 0.0 to 0.4 mm for volumetric registrations. For patient planar registrations, the mean shift differences were 0.4 ± 0.5 mm (range, −0.6 to 1.6 mm), 0.0 ± 0.5 mm (range, −0.9 to 1.2 mm), and 0.1 ± 0.3 mm (range, −0.7 to 0.6 mm) for the superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) axes, respectively. The mean shift differences in volumetric registrations were 0.6 ± 0.4 mm (range, −0.2 to 1.6 mm), 0.2 ± 0.4 mm (range, −0.3 to 1.2 mm), and 0.2 ± 0.3 mm (range, −0.2 to 1.2 mm) for the S-I, L-R, and A-P axes, respectively. The CT-SIM and synCT derived margins were <0.3 mm different. Conclusion: DRRs generated by synCT were in close agreement with CT-SIM. Planar and volumetric image registrations to synCT-derived targets were comparable with CT for phantom and patients. This validation is the next step toward MR-only planning for the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Strain-rate Dependent Dislocation-Defect Interactions by Atomistic Simulations

Probing the mechanisms of defect-defect interactions at strain rates lower than 106 s-1 is an unresolved challenge to date to molecular dynamics (MD) techniques. Here we propose a novel atomistic approach based on transition state theory and the concept of a strain-dependent effective activation barrier that is capable of simulating the kinetics of dislocation-defect interactions at virtually any strain rate, exemplified within 10-7 to 107 s-1. We apply this approach to the problem of an edge dislocation colliding with a cluster of self-interstitial atoms (SIA) under shear deformation. Using an activation-relaxation algorithm (1), we uncover a unique strain-rate dependent trigger mechanism that allows the SIA cluster to be absorbed during the process leading to dislocation climb. Guided by this finding, we determine the activation barrier of the trigger mechanism as a function of shear strain, and use that in a coarse-graining rate equation formulation for constructing a mechanism map in the phase space of strain-rate and temperature. Our predictions of a crossover from a defect recovery at the low strain rate regime to defect absorption behavior in the high strain-rate regime are validated against our own independent, direct MD simulations at 105 to 107 s-1. Implications of the present approach for probing molecular-level mechanisms in strain-rate regimes previously considered inaccessible to atomistic simulations are discussed.

activation mecanism↗

Volumetric breast density evaluation from ultrasound tomography images

Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work was to explore a metric to quantify breast density using our ultrasound tomography sound speed images in a manner analogous to computer-assisted mammogram segmentation for breast density analysis. Therefore, volumetric ultrasound percent density (USPD) is determined by segmenting high sound speed areas from each tomogram using a k-means clustering routine, integrating these results over the entire volume of the breast, and dividing by whole-breast volume. First, a breast phantom comprised of fat inclusions embedded in fibroglandular tissue was scanned four times with both our ultrasound tomography clinical prototype (with 4 mm spatial resolution) and CT. The coronal transmission tomograms and CT images were analyzed using semiautomatic segmentation routines, and the integrated areas of the phantom's fat inclusions were compared between the four repeated scans. The average variability for inclusion segmentation was {approx}7% and {approx}2%, respectively, and a close correlation was observed in the integrated areas between the two modalities. Next, a cohort of 93 patients was imaged, yielding volumetric coverage of the breast (45-75 sound speed tomograms/patient). The association of USPD with mammographic percent density (MPD) was evaluated using two measures: (1) qualitative, as determined by a radiologist's visual assessment using BI-RADS Criteria and (2) quantitative, via digitization and semiautomatic segmentation of craniocaudal and mediolateral oblique mammograms. A strong positive association between BI-RADS category and USPD was demonstrated [Spearman {rho}=0.69 (p<0.001)], with significant differences between all BI-RADS categories as assessed by one-way ANOVA and Scheffe posthoc analysis. Furthermore, comparing USPD to calculated mammographic density yielded moderate to strong positive associations for CC and MLO views (r{sup 2}=0.75 and 0.59, respectively). These results support the hypothesis that utilizing USPD as an analogue to mammographic breast density is feasible, providing a nonionizing, whole-breast analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simplified method of four-dimensional dose accumulation using the mean patient density representation

The purpose of this work was to demonstrate, both in phantom and patient, the feasibility of using an average 4DCT image set (AVG-CT) for 4D cumulative dose estimation. A series of 4DCT numerical phantoms and corresponding AVG-CTs were generated. For full 4D dose summation, static dose was calculated on each phase and cumulative dose was determined by combining each phase's static dose distribution with known tumor displacement. The AVG-CT cumulative dose was calculated similarly, although the same AVG-CT static dose distribution was used for all phases (i.e., tumor displacements). Four lung cancer cases were also evaluated for stereotactic body radiotherapy and conformal treatments; however, deformable image registration of the 4DCTs was used to generate the displacement vector fields (DVFs) describing patient-specific motion. Dose discrepancy between full 4D summation and AVG-CT approach was calculated and compared. For all phantoms, AVG-CT approximation yielded slightly higher cumulative doses compared to full 4D summation, with dose discrepancy increasing with increased tumor excursion. In vivo, using the AVG-CT coupled with deformable registration yielded clinically insignificant differences for all GTV parameters including the minimum, mean, maximum, dose to 99% of target, and dose to 1% of target. Furthermore, analysis of the spinal cord, esophagus, and heart revealed negligible differences in major dosimetric indices and dose coverage between the two dose calculation techniques. Simplifying 4D dose accumulation via the AVG-CT, while fully accounting for tumor deformation due to respiratory motion, has been validated, thereby, introducing the potential to streamline the use of 4D dose calculations in clinical practice, particularly for adaptive planning purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of the Varian TrueBeam linear accelerator: A multi-institutional study

Purpose: Latest generation linear accelerators (linacs), i.e., TrueBeam (Varian Medical Systems, Palo Alto, CA) and its stereotactic counterpart, TrueBeam STx, have several unique features, including high-dose-rate flattening-filter-free (FFF) photon modes, reengineered electron modes with new scattering foil geometries, updated imaging hardware/software, and a novel control system. An evaluation of five TrueBeam linacs at three different institutions has been performed and this work reports on the commissioning experience. Methods: Acceptance and commissioning data were analyzed for five TrueBeam linacs equipped with 120 leaf (5 mm width) MLCs at three different institutions. Dosimetric data and mechanical parameters were compared. These included measurements of photon beam profiles (6X, 6XFFF, 10X, 10XFFF, 15X), photon and electron percent depth dose (PDD) curves (6, 9, 12 MeV), relative photon output factors (Scp), electron cone factors, mechanical isocenter accuracy, MLC transmission, and dosimetric leaf gap (DLG). End-to-end testing and IMRT commissioning were also conducted. Results: Gantry/collimator isocentricity measurements were similar (0.27-0.28 mm), with overall couch/gantry/collimator values of 0.46-0.68 mm across the three institutions. Dosimetric data showed good agreement between machines. The average MLC DLGs for 6, 10, and 15 MV photons were 1.33 {+-} 0.23, 1.57 {+-} 0.24, and 1.61 {+-} 0.26 mm, respectively. 6XFFF and 10XFFF modes had average DLGs of 1.16 {+-} 0.22 and 1.44 {+-} 0.30 mm, respectively. MLC transmission showed minimal variation across the three institutions, with the standard deviation <0.2% for all linacs. Photon and electron PDDs were comparable for all energies. 6, 10, and 15 MV photon beam quality, %dd(10){sub x} varied less than 0.3% for all linacs. Output factors (Scp) and electron cone factors agreed within 0.27%, on average; largest variations were observed for small field sizes (1.2% coefficient of variation, 10 MV, 2 Multiplication-Sign 2 cm{sup 2}) and small cone sizes (<1% coefficient of variation, 6 Multiplication-Sign 6 cm{sup 2} cone), respectively. Conclusions: Overall, excellent agreement was observed in TrueBeam commissioning data. This set of multi-institutional data can provide comparison data to others embarking on TrueBeam commissioning, ultimately improving the safety and quality of beam commissioning.

43 PARTICLE ACCELERATORS↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗